Self-prevention of instability in a low-power microwave Ar plasma jet for biomedical applications

The behavior of a low-power microwave Ar plasma jet according to the target shape and distance is investigated. The plasma jet shows distinct behavior when it contacts a human finger or grounded metals. No plasma channel and no attraction of the jet to the human finger and metal plate are observed i...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of physics. D, Applied physics Applied physics, 2015-04, Vol.48 (15), p.155203-10
Hauptverfasser: Lee, H W, Kim, M S, Won, I H, Yun, G S, Lee, J K
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The behavior of a low-power microwave Ar plasma jet according to the target shape and distance is investigated. The plasma jet shows distinct behavior when it contacts a human finger or grounded metals. No plasma channel and no attraction of the jet to the human finger and metal plate are observed in contrast to low-frequency plasmas. Glow-to-arc transition does not occur even at a very small target distance (