Hydride Generation/Condensation System With an Inductively Coupled Argon Plasma Polychromator for Simultaneous Determination of Arsenic, Antimony, Selenium, Lead, Mercury and Tin in Honey

An efficient method for the determination of nanogram levels of heavy metals in honey is described. Honey samples obtained in the field from farms located along the coast of the province of Cap-Bon (North Tunisia) were analysed by hydride generation with an inductively coupled argon plasma polychrom...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of environmental analytical chemistry 1995-11, Vol.61 (3), p.249-256
Hauptverfasser: Jamoussi, B., Zafaouf, M., Hassine, B. Ben
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 256
container_issue 3
container_start_page 249
container_title International journal of environmental analytical chemistry
container_volume 61
creator Jamoussi, B.
Zafaouf, M.
Hassine, B. Ben
description An efficient method for the determination of nanogram levels of heavy metals in honey is described. Honey samples obtained in the field from farms located along the coast of the province of Cap-Bon (North Tunisia) were analysed by hydride generation with an inductively coupled argon plasma polychromator after a previous treatment in a microwave acid bomb. An apparatus for the generation of volatile hydrides, interfaced with an inductively coupled argon plasma polychromator for simultaneous determination of As, Pb, Sb, Hg and Sn, is used. The optimum conditions for generating and determining the compounds and the effect of different parameters are discussed. The parameters investigated include: the chemical nature, form and concentration of the reductant, acid concentration of the sample and the carrier gas flow rate. Detection limits range 0.05 ng/ml for Hg to 1.1 ng/ml for Sb and precision values at 10 ng/ml are less than 6% of the relative standard deviation. Analytical protocols concerning analytical stages are exposed and discussed.
doi_str_mv 10.1080/03067319508027239
format Article
fullrecord <record><control><sourceid>proquest_pasca</sourceid><recordid>TN_cdi_proquest_miscellaneous_17007486</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>17007486</sourcerecordid><originalsourceid>FETCH-LOGICAL-c356t-dfabaf342a2f11d6d1ebd128594712fcc1b3ffdbe5fd4e544f6687ac8416bd283</originalsourceid><addsrcrecordid>eNp1kU2LFDEQhhtRcNzdH-AtB_E07Sad_gQvw6zuLMyyC7PisUknFTeSjzFJK_lt_jkz9upFhBShKs_7FpUqitcEvyO4x5eY4rajZGhyUnUVHZ4VK4KrocR06J4Xq9N7eQJeFq9C-IoxoU1PV8XPXRJeCUDXYMGzqJy93DorwIbfCTqkEMGgzyo-ImbRjRUzj-o76IS2bj5qEGjjv2TwXrNgGLp3OvFH7wyLziOZ46DMrCOz4OaAriCCN8ou5k5mcQCr-BptbFTG2bRGB9C5NJs12gMTa3QLns8-5fYCPSiL8tk5C-m8eCGZDnDxdJ8Vnz5-eNjuyv3d9c12sy85bdpYCskmJmldsUoSIlpBYBKk6puh7kglOScTlVJM0EhRQ1PXsm37jvG-Ju0kqp6eFW8X36N332YIcTQqcNB6mWkkHcZd3bcZJAvIvQvBgxyPXhnm00jweFrT-M-asubNkzkLnGnpmeUq_BVSPAx1U2Xs_YIpm__UsB_OazFGlrTzfzT0_11-AcevqTQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>17007486</pqid></control><display><type>article</type><title>Hydride Generation/Condensation System With an Inductively Coupled Argon Plasma Polychromator for Simultaneous Determination of Arsenic, Antimony, Selenium, Lead, Mercury and Tin in Honey</title><source>Taylor &amp; Francis Journals Complete</source><creator>Jamoussi, B. ; Zafaouf, M. ; Hassine, B. Ben</creator><creatorcontrib>Jamoussi, B. ; Zafaouf, M. ; Hassine, B. Ben</creatorcontrib><description>An efficient method for the determination of nanogram levels of heavy metals in honey is described. Honey samples obtained in the field from farms located along the coast of the province of Cap-Bon (North Tunisia) were analysed by hydride generation with an inductively coupled argon plasma polychromator after a previous treatment in a microwave acid bomb. An apparatus for the generation of volatile hydrides, interfaced with an inductively coupled argon plasma polychromator for simultaneous determination of As, Pb, Sb, Hg and Sn, is used. The optimum conditions for generating and determining the compounds and the effect of different parameters are discussed. The parameters investigated include: the chemical nature, form and concentration of the reductant, acid concentration of the sample and the carrier gas flow rate. Detection limits range 0.05 ng/ml for Hg to 1.1 ng/ml for Sb and precision values at 10 ng/ml are less than 6% of the relative standard deviation. Analytical protocols concerning analytical stages are exposed and discussed.</description><identifier>ISSN: 0306-7319</identifier><identifier>EISSN: 1029-0397</identifier><identifier>DOI: 10.1080/03067319508027239</identifier><identifier>CODEN: IJEAA3</identifier><language>eng</language><publisher>Amsterdam: Taylor &amp; Francis Group</publisher><subject>Analytical chemistry ; Chemistry ; Exact sciences and technology ; heavy metals ; Honey ; hydride generation ; ICP ; Miscellaneous</subject><ispartof>International journal of environmental analytical chemistry, 1995-11, Vol.61 (3), p.249-256</ispartof><rights>Copyright Taylor &amp; Francis Group, LLC 1995</rights><rights>1996 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c356t-dfabaf342a2f11d6d1ebd128594712fcc1b3ffdbe5fd4e544f6687ac8416bd283</citedby><cites>FETCH-LOGICAL-c356t-dfabaf342a2f11d6d1ebd128594712fcc1b3ffdbe5fd4e544f6687ac8416bd283</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.tandfonline.com/doi/pdf/10.1080/03067319508027239$$EPDF$$P50$$Ginformaworld$$H</linktopdf><linktohtml>$$Uhttps://www.tandfonline.com/doi/full/10.1080/03067319508027239$$EHTML$$P50$$Ginformaworld$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,59647,60436</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=3099452$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Jamoussi, B.</creatorcontrib><creatorcontrib>Zafaouf, M.</creatorcontrib><creatorcontrib>Hassine, B. Ben</creatorcontrib><title>Hydride Generation/Condensation System With an Inductively Coupled Argon Plasma Polychromator for Simultaneous Determination of Arsenic, Antimony, Selenium, Lead, Mercury and Tin in Honey</title><title>International journal of environmental analytical chemistry</title><description>An efficient method for the determination of nanogram levels of heavy metals in honey is described. Honey samples obtained in the field from farms located along the coast of the province of Cap-Bon (North Tunisia) were analysed by hydride generation with an inductively coupled argon plasma polychromator after a previous treatment in a microwave acid bomb. An apparatus for the generation of volatile hydrides, interfaced with an inductively coupled argon plasma polychromator for simultaneous determination of As, Pb, Sb, Hg and Sn, is used. The optimum conditions for generating and determining the compounds and the effect of different parameters are discussed. The parameters investigated include: the chemical nature, form and concentration of the reductant, acid concentration of the sample and the carrier gas flow rate. Detection limits range 0.05 ng/ml for Hg to 1.1 ng/ml for Sb and precision values at 10 ng/ml are less than 6% of the relative standard deviation. Analytical protocols concerning analytical stages are exposed and discussed.</description><subject>Analytical chemistry</subject><subject>Chemistry</subject><subject>Exact sciences and technology</subject><subject>heavy metals</subject><subject>Honey</subject><subject>hydride generation</subject><subject>ICP</subject><subject>Miscellaneous</subject><issn>0306-7319</issn><issn>1029-0397</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1995</creationdate><recordtype>article</recordtype><recordid>eNp1kU2LFDEQhhtRcNzdH-AtB_E07Sad_gQvw6zuLMyyC7PisUknFTeSjzFJK_lt_jkz9upFhBShKs_7FpUqitcEvyO4x5eY4rajZGhyUnUVHZ4VK4KrocR06J4Xq9N7eQJeFq9C-IoxoU1PV8XPXRJeCUDXYMGzqJy93DorwIbfCTqkEMGgzyo-ImbRjRUzj-o76IS2bj5qEGjjv2TwXrNgGLp3OvFH7wyLziOZ46DMrCOz4OaAriCCN8ou5k5mcQCr-BptbFTG2bRGB9C5NJs12gMTa3QLns8-5fYCPSiL8tk5C-m8eCGZDnDxdJ8Vnz5-eNjuyv3d9c12sy85bdpYCskmJmldsUoSIlpBYBKk6puh7kglOScTlVJM0EhRQ1PXsm37jvG-Ju0kqp6eFW8X36N332YIcTQqcNB6mWkkHcZd3bcZJAvIvQvBgxyPXhnm00jweFrT-M-asubNkzkLnGnpmeUq_BVSPAx1U2Xs_YIpm__UsB_OazFGlrTzfzT0_11-AcevqTQ</recordid><startdate>19951101</startdate><enddate>19951101</enddate><creator>Jamoussi, B.</creator><creator>Zafaouf, M.</creator><creator>Hassine, B. Ben</creator><general>Taylor &amp; Francis Group</general><general>Gordon and Breach Science</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7T2</scope><scope>7U2</scope><scope>7U7</scope><scope>C1K</scope></search><sort><creationdate>19951101</creationdate><title>Hydride Generation/Condensation System With an Inductively Coupled Argon Plasma Polychromator for Simultaneous Determination of Arsenic, Antimony, Selenium, Lead, Mercury and Tin in Honey</title><author>Jamoussi, B. ; Zafaouf, M. ; Hassine, B. Ben</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c356t-dfabaf342a2f11d6d1ebd128594712fcc1b3ffdbe5fd4e544f6687ac8416bd283</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1995</creationdate><topic>Analytical chemistry</topic><topic>Chemistry</topic><topic>Exact sciences and technology</topic><topic>heavy metals</topic><topic>Honey</topic><topic>hydride generation</topic><topic>ICP</topic><topic>Miscellaneous</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jamoussi, B.</creatorcontrib><creatorcontrib>Zafaouf, M.</creatorcontrib><creatorcontrib>Hassine, B. Ben</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Health and Safety Science Abstracts (Full archive)</collection><collection>Safety Science and Risk</collection><collection>Toxicology Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><jtitle>International journal of environmental analytical chemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jamoussi, B.</au><au>Zafaouf, M.</au><au>Hassine, B. Ben</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Hydride Generation/Condensation System With an Inductively Coupled Argon Plasma Polychromator for Simultaneous Determination of Arsenic, Antimony, Selenium, Lead, Mercury and Tin in Honey</atitle><jtitle>International journal of environmental analytical chemistry</jtitle><date>1995-11-01</date><risdate>1995</risdate><volume>61</volume><issue>3</issue><spage>249</spage><epage>256</epage><pages>249-256</pages><issn>0306-7319</issn><eissn>1029-0397</eissn><coden>IJEAA3</coden><abstract>An efficient method for the determination of nanogram levels of heavy metals in honey is described. Honey samples obtained in the field from farms located along the coast of the province of Cap-Bon (North Tunisia) were analysed by hydride generation with an inductively coupled argon plasma polychromator after a previous treatment in a microwave acid bomb. An apparatus for the generation of volatile hydrides, interfaced with an inductively coupled argon plasma polychromator for simultaneous determination of As, Pb, Sb, Hg and Sn, is used. The optimum conditions for generating and determining the compounds and the effect of different parameters are discussed. The parameters investigated include: the chemical nature, form and concentration of the reductant, acid concentration of the sample and the carrier gas flow rate. Detection limits range 0.05 ng/ml for Hg to 1.1 ng/ml for Sb and precision values at 10 ng/ml are less than 6% of the relative standard deviation. Analytical protocols concerning analytical stages are exposed and discussed.</abstract><cop>Amsterdam</cop><pub>Taylor &amp; Francis Group</pub><doi>10.1080/03067319508027239</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0306-7319
ispartof International journal of environmental analytical chemistry, 1995-11, Vol.61 (3), p.249-256
issn 0306-7319
1029-0397
language eng
recordid cdi_proquest_miscellaneous_17007486
source Taylor & Francis Journals Complete
subjects Analytical chemistry
Chemistry
Exact sciences and technology
heavy metals
Honey
hydride generation
ICP
Miscellaneous
title Hydride Generation/Condensation System With an Inductively Coupled Argon Plasma Polychromator for Simultaneous Determination of Arsenic, Antimony, Selenium, Lead, Mercury and Tin in Honey
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T09%3A42%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pasca&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Hydride%20Generation/Condensation%20System%20With%20an%20Inductively%20Coupled%20Argon%20Plasma%20Polychromator%20for%20Simultaneous%20Determination%20of%20Arsenic,%20Antimony,%20Selenium,%20Lead,%20Mercury%20and%20Tin%20in%20Honey&rft.jtitle=International%20journal%20of%20environmental%20analytical%20chemistry&rft.au=Jamoussi,%20B.&rft.date=1995-11-01&rft.volume=61&rft.issue=3&rft.spage=249&rft.epage=256&rft.pages=249-256&rft.issn=0306-7319&rft.eissn=1029-0397&rft.coden=IJEAA3&rft_id=info:doi/10.1080/03067319508027239&rft_dat=%3Cproquest_pasca%3E17007486%3C/proquest_pasca%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=17007486&rft_id=info:pmid/&rfr_iscdi=true