Comment on “Characterization of the Exradin W1 scintillator for use in radiotherapy” [Med. Phys. 42, 297–304 (2015)]
Gespeichert in:
Veröffentlicht in: | Medical physics (Lancaster) 2015-07, Vol.42 (7), p.4414-4416 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 4416 |
---|---|
container_issue | 7 |
container_start_page | 4414 |
container_title | Medical physics (Lancaster) |
container_volume | 42 |
creator | Beierholm, A. R. Behrens, C. F. Andersen, C. E. |
description | |
doi_str_mv | 10.1118/1.4922656 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1693719178</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1693719178</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3236-8ce456f35c8897c67fcb49582ece06ec243c800d1a81bc5652751f14caeba5a33</originalsourceid><addsrcrecordid>eNp10MtKw0AUBuBBFFsvC19AZlnB1DlzS2YpxRtU7EJxIRKm0xMaaZI6k6J11Xdwqy_XJzHa6s7FcGDOxw_nJ-QAWBcAkhPoSsO5VnqDtLmMRSQ5M5ukzZiREZdMtchOCE-MMS0U2yYtrkEILUybvPWqosCyplVJl4uP3th662r0-Zut8-avymg9Rnr26u0oL-k90ODyss4nE1tXnmbNmwWkzeobVI31djpfLj7pwzWOunQwnoculfyYchMvF--CSdrhDNTR4x7Zyuwk4P567pK787Pb3mXUv7m46p32Iye40FHiUCqdCeWSxMROx5kbSqMSjg6ZRselcAljI7AJDJ3SiscKMpDO4tAqK8Qu6axyp756nmGo0yIPDpsLSqxmIQVtRAwG4qShRyvqfBWCxyyd-rywfp4CS7-rTiFdV93Yw3XsbFjg6E_-dtuAaAVe8gnO_09Krwc_gV-ovoXW</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1693719178</pqid></control><display><type>article</type><title>Comment on “Characterization of the Exradin W1 scintillator for use in radiotherapy” [Med. Phys. 42, 297–304 (2015)]</title><source>MEDLINE</source><source>Access via Wiley Online Library</source><source>Alma/SFX Local Collection</source><creator>Beierholm, A. R. ; Behrens, C. F. ; Andersen, C. E.</creator><creatorcontrib>Beierholm, A. R. ; Behrens, C. F. ; Andersen, C. E.</creatorcontrib><identifier>ISSN: 0094-2405</identifier><identifier>EISSN: 2473-4209</identifier><identifier>DOI: 10.1118/1.4922656</identifier><identifier>PMID: 26133639</identifier><language>eng</language><publisher>United States: American Association of Physicists in Medicine</publisher><subject>Calibrating of instruments or apparatus ; calibration ; dosimetry ; Dosimetry/exposure assessment ; Electromagnetic radiation detectors ; Error analysis ; Field size ; Measurement of nuclear or x‐radiation ; Optical fiber testing ; Particle beam detectors ; Photons ; Plates or blocks in which tracks of nuclear particles are made visible by after‐treatment, e.g. using photographic emulsion, using mica ; radiation therapy ; Radiotherapy - instrumentation ; Scintigraphy ; Scintillation detectors ; solid scintillation detectors ; Standards and calibration ; Testing or calibrating of apparatus or arrangements provided for in groups G01D1/00 to G01D15/00 ; the detector being a crystal ; the detector being a liquid ; the detector being made of plastics ; Therapeutic applications, including brachytherapy ; Tubes for determining the presence, intensity, density or energy of radiation or particles ; with semiconductor detectors</subject><ispartof>Medical physics (Lancaster), 2015-07, Vol.42 (7), p.4414-4416</ispartof><rights>2015 American Association of Physicists in Medicine</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3236-8ce456f35c8897c67fcb49582ece06ec243c800d1a81bc5652751f14caeba5a33</citedby><cites>FETCH-LOGICAL-c3236-8ce456f35c8897c67fcb49582ece06ec243c800d1a81bc5652751f14caeba5a33</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1118%2F1.4922656$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1118%2F1.4922656$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>315,781,785,1418,27926,27927,45576,45577</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26133639$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Beierholm, A. R.</creatorcontrib><creatorcontrib>Behrens, C. F.</creatorcontrib><creatorcontrib>Andersen, C. E.</creatorcontrib><title>Comment on “Characterization of the Exradin W1 scintillator for use in radiotherapy” [Med. Phys. 42, 297–304 (2015)]</title><title>Medical physics (Lancaster)</title><addtitle>Med Phys</addtitle><subject>Calibrating of instruments or apparatus</subject><subject>calibration</subject><subject>dosimetry</subject><subject>Dosimetry/exposure assessment</subject><subject>Electromagnetic radiation detectors</subject><subject>Error analysis</subject><subject>Field size</subject><subject>Measurement of nuclear or x‐radiation</subject><subject>Optical fiber testing</subject><subject>Particle beam detectors</subject><subject>Photons</subject><subject>Plates or blocks in which tracks of nuclear particles are made visible by after‐treatment, e.g. using photographic emulsion, using mica</subject><subject>radiation therapy</subject><subject>Radiotherapy - instrumentation</subject><subject>Scintigraphy</subject><subject>Scintillation detectors</subject><subject>solid scintillation detectors</subject><subject>Standards and calibration</subject><subject>Testing or calibrating of apparatus or arrangements provided for in groups G01D1/00 to G01D15/00</subject><subject>the detector being a crystal</subject><subject>the detector being a liquid</subject><subject>the detector being made of plastics</subject><subject>Therapeutic applications, including brachytherapy</subject><subject>Tubes for determining the presence, intensity, density or energy of radiation or particles</subject><subject>with semiconductor detectors</subject><issn>0094-2405</issn><issn>2473-4209</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp10MtKw0AUBuBBFFsvC19AZlnB1DlzS2YpxRtU7EJxIRKm0xMaaZI6k6J11Xdwqy_XJzHa6s7FcGDOxw_nJ-QAWBcAkhPoSsO5VnqDtLmMRSQ5M5ukzZiREZdMtchOCE-MMS0U2yYtrkEILUybvPWqosCyplVJl4uP3th662r0-Zut8-avymg9Rnr26u0oL-k90ODyss4nE1tXnmbNmwWkzeobVI31djpfLj7pwzWOunQwnoculfyYchMvF--CSdrhDNTR4x7Zyuwk4P567pK787Pb3mXUv7m46p32Iye40FHiUCqdCeWSxMROx5kbSqMSjg6ZRselcAljI7AJDJ3SiscKMpDO4tAqK8Qu6axyp756nmGo0yIPDpsLSqxmIQVtRAwG4qShRyvqfBWCxyyd-rywfp4CS7-rTiFdV93Yw3XsbFjg6E_-dtuAaAVe8gnO_09Krwc_gV-ovoXW</recordid><startdate>201507</startdate><enddate>201507</enddate><creator>Beierholm, A. R.</creator><creator>Behrens, C. F.</creator><creator>Andersen, C. E.</creator><general>American Association of Physicists in Medicine</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201507</creationdate><title>Comment on “Characterization of the Exradin W1 scintillator for use in radiotherapy” [Med. Phys. 42, 297–304 (2015)]</title><author>Beierholm, A. R. ; Behrens, C. F. ; Andersen, C. E.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3236-8ce456f35c8897c67fcb49582ece06ec243c800d1a81bc5652751f14caeba5a33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Calibrating of instruments or apparatus</topic><topic>calibration</topic><topic>dosimetry</topic><topic>Dosimetry/exposure assessment</topic><topic>Electromagnetic radiation detectors</topic><topic>Error analysis</topic><topic>Field size</topic><topic>Measurement of nuclear or x‐radiation</topic><topic>Optical fiber testing</topic><topic>Particle beam detectors</topic><topic>Photons</topic><topic>Plates or blocks in which tracks of nuclear particles are made visible by after‐treatment, e.g. using photographic emulsion, using mica</topic><topic>radiation therapy</topic><topic>Radiotherapy - instrumentation</topic><topic>Scintigraphy</topic><topic>Scintillation detectors</topic><topic>solid scintillation detectors</topic><topic>Standards and calibration</topic><topic>Testing or calibrating of apparatus or arrangements provided for in groups G01D1/00 to G01D15/00</topic><topic>the detector being a crystal</topic><topic>the detector being a liquid</topic><topic>the detector being made of plastics</topic><topic>Therapeutic applications, including brachytherapy</topic><topic>Tubes for determining the presence, intensity, density or energy of radiation or particles</topic><topic>with semiconductor detectors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Beierholm, A. R.</creatorcontrib><creatorcontrib>Behrens, C. F.</creatorcontrib><creatorcontrib>Andersen, C. E.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Medical physics (Lancaster)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Beierholm, A. R.</au><au>Behrens, C. F.</au><au>Andersen, C. E.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comment on “Characterization of the Exradin W1 scintillator for use in radiotherapy” [Med. Phys. 42, 297–304 (2015)]</atitle><jtitle>Medical physics (Lancaster)</jtitle><addtitle>Med Phys</addtitle><date>2015-07</date><risdate>2015</risdate><volume>42</volume><issue>7</issue><spage>4414</spage><epage>4416</epage><pages>4414-4416</pages><issn>0094-2405</issn><eissn>2473-4209</eissn><cop>United States</cop><pub>American Association of Physicists in Medicine</pub><pmid>26133639</pmid><doi>10.1118/1.4922656</doi><tpages>3</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0094-2405 |
ispartof | Medical physics (Lancaster), 2015-07, Vol.42 (7), p.4414-4416 |
issn | 0094-2405 2473-4209 |
language | eng |
recordid | cdi_proquest_miscellaneous_1693719178 |
source | MEDLINE; Access via Wiley Online Library; Alma/SFX Local Collection |
subjects | Calibrating of instruments or apparatus calibration dosimetry Dosimetry/exposure assessment Electromagnetic radiation detectors Error analysis Field size Measurement of nuclear or x‐radiation Optical fiber testing Particle beam detectors Photons Plates or blocks in which tracks of nuclear particles are made visible by after‐treatment, e.g. using photographic emulsion, using mica radiation therapy Radiotherapy - instrumentation Scintigraphy Scintillation detectors solid scintillation detectors Standards and calibration Testing or calibrating of apparatus or arrangements provided for in groups G01D1/00 to G01D15/00 the detector being a crystal the detector being a liquid the detector being made of plastics Therapeutic applications, including brachytherapy Tubes for determining the presence, intensity, density or energy of radiation or particles with semiconductor detectors |
title | Comment on “Characterization of the Exradin W1 scintillator for use in radiotherapy” [Med. Phys. 42, 297–304 (2015)] |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-18T06%3A02%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comment%20on%20%E2%80%9CCharacterization%20of%20the%20Exradin%20W1%20scintillator%20for%20use%20in%20radiotherapy%E2%80%9D%20%5BMed.%20Phys.%2042,%20297%E2%80%93304%20(2015)%5D&rft.jtitle=Medical%20physics%20(Lancaster)&rft.au=Beierholm,%20A.%20R.&rft.date=2015-07&rft.volume=42&rft.issue=7&rft.spage=4414&rft.epage=4416&rft.pages=4414-4416&rft.issn=0094-2405&rft.eissn=2473-4209&rft_id=info:doi/10.1118/1.4922656&rft_dat=%3Cproquest_cross%3E1693719178%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1693719178&rft_id=info:pmid/26133639&rfr_iscdi=true |