Direct multi-element analysis of plastic materials viasolid sampling electrothermal vaporization inductively coupled plasma optical emission spectroscopy

In this work the determination of Cd, Cu, Cr, Fe and Sb as organic and inorganic additives in in-house plastic materials (ABS, LDPE) using electrothermal vaporization combined with inductively coupled plasma optical emission spectroscopy is described. The influence of CCl sub(2)F sub(2) as gaseous h...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of analytical atomic spectrometry 2015-04, Vol.30 (5), p.1064-1071
Hauptverfasser: Borno, F, Richter, S, Deiting, D, Jakubowski, N, Panne, U
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1071
container_issue 5
container_start_page 1064
container_title Journal of analytical atomic spectrometry
container_volume 30
creator Borno, F
Richter, S
Deiting, D
Jakubowski, N
Panne, U
description In this work the determination of Cd, Cu, Cr, Fe and Sb as organic and inorganic additives in in-house plastic materials (ABS, LDPE) using electrothermal vaporization combined with inductively coupled plasma optical emission spectroscopy is described. The influence of CCl sub(2)F sub(2) as gaseous halogenation modifier was investigated. Especially for the carbide forming elements the sensitivity was improved and the memory effects were significantly reduced. Calibration was performed by external calibration and standard addition with aqueous standard solutions added directly into the sample boats. Absolute limits of detection (3s-criterion) range between 0.1 ng (Cd) and 9 ng (Fe) which corresponds to relative values of 0.1 mg kg super(-1) and 1.6 mg kg super(-1), respectively, taking 5 mg as typical sample mass. The detection limits are sufficient to monitor the element contents of plastic materials according to European directives such as European directive on the safety of toys. The developed ETV-ICP-OES method allows a fast analysis with a high sample throughput (3 minutes per analysis), low sample consumption and good trueness and precision for the analyzed elements. Sample preparation is reduced to ashing the samples in a muffle furnace. Furthermore, measurements are possible regardless of the chemical form in the additives. For verification the results obtained with the developed method were compared with measurement results of independent methods ICP-MS/OES after digestion. In addition Cd, Cr and Pb were determined in a solid plastic reference material BAM-H010 to confirm the applicability and accuracy of the method.
doi_str_mv 10.1039/c4ja00442f
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_1692409783</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1692409783</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_16924097833</originalsourceid><addsrcrecordid>eNqVjUlOxDAQRS0EEs2w4QResgk4iZOQNYM4APtWyalAtTzhciKFm3BbTIsLsPqb994X4qZWd7Vqx3ujD6CU1s18InZ12-uq67Q-FTvV9EM16mE4FxfMB1Wgrul24vuJEpos3WIzVWjRoc8SPNiNiWWYZbTAmYx0kDERWJYrAQdLk2Rw0ZJ_l8UzOYX8gcmBlSvEkOgLMgUvyU-LybSi3aQJS7Q4HZsOZIglXHh0xPzLcjx22IS4XYmzubzh9d9eituX57fH1yqm8Lkg532xDFoLHsPC-7ofG63G4aFt_4H-AJ0VZvk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1692409783</pqid></control><display><type>article</type><title>Direct multi-element analysis of plastic materials viasolid sampling electrothermal vaporization inductively coupled plasma optical emission spectroscopy</title><source>Royal Society Of Chemistry Journals 2008-</source><source>Alma/SFX Local Collection</source><creator>Borno, F ; Richter, S ; Deiting, D ; Jakubowski, N ; Panne, U</creator><creatorcontrib>Borno, F ; Richter, S ; Deiting, D ; Jakubowski, N ; Panne, U</creatorcontrib><description>In this work the determination of Cd, Cu, Cr, Fe and Sb as organic and inorganic additives in in-house plastic materials (ABS, LDPE) using electrothermal vaporization combined with inductively coupled plasma optical emission spectroscopy is described. The influence of CCl sub(2)F sub(2) as gaseous halogenation modifier was investigated. Especially for the carbide forming elements the sensitivity was improved and the memory effects were significantly reduced. Calibration was performed by external calibration and standard addition with aqueous standard solutions added directly into the sample boats. Absolute limits of detection (3s-criterion) range between 0.1 ng (Cd) and 9 ng (Fe) which corresponds to relative values of 0.1 mg kg super(-1) and 1.6 mg kg super(-1), respectively, taking 5 mg as typical sample mass. The detection limits are sufficient to monitor the element contents of plastic materials according to European directives such as European directive on the safety of toys. The developed ETV-ICP-OES method allows a fast analysis with a high sample throughput (3 minutes per analysis), low sample consumption and good trueness and precision for the analyzed elements. Sample preparation is reduced to ashing the samples in a muffle furnace. Furthermore, measurements are possible regardless of the chemical form in the additives. For verification the results obtained with the developed method were compared with measurement results of independent methods ICP-MS/OES after digestion. In addition Cd, Cr and Pb were determined in a solid plastic reference material BAM-H010 to confirm the applicability and accuracy of the method.</description><identifier>ISSN: 0267-9477</identifier><identifier>EISSN: 1364-5544</identifier><identifier>DOI: 10.1039/c4ja00442f</identifier><language>eng</language><subject>Additives ; Chromium ; Inductively coupled plasma ; Iron ; Optical emission spectroscopy ; Polyethylenes ; Vaporization</subject><ispartof>Journal of analytical atomic spectrometry, 2015-04, Vol.30 (5), p.1064-1071</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27922,27923</link.rule.ids></links><search><creatorcontrib>Borno, F</creatorcontrib><creatorcontrib>Richter, S</creatorcontrib><creatorcontrib>Deiting, D</creatorcontrib><creatorcontrib>Jakubowski, N</creatorcontrib><creatorcontrib>Panne, U</creatorcontrib><title>Direct multi-element analysis of plastic materials viasolid sampling electrothermal vaporization inductively coupled plasma optical emission spectroscopy</title><title>Journal of analytical atomic spectrometry</title><description>In this work the determination of Cd, Cu, Cr, Fe and Sb as organic and inorganic additives in in-house plastic materials (ABS, LDPE) using electrothermal vaporization combined with inductively coupled plasma optical emission spectroscopy is described. The influence of CCl sub(2)F sub(2) as gaseous halogenation modifier was investigated. Especially for the carbide forming elements the sensitivity was improved and the memory effects were significantly reduced. Calibration was performed by external calibration and standard addition with aqueous standard solutions added directly into the sample boats. Absolute limits of detection (3s-criterion) range between 0.1 ng (Cd) and 9 ng (Fe) which corresponds to relative values of 0.1 mg kg super(-1) and 1.6 mg kg super(-1), respectively, taking 5 mg as typical sample mass. The detection limits are sufficient to monitor the element contents of plastic materials according to European directives such as European directive on the safety of toys. The developed ETV-ICP-OES method allows a fast analysis with a high sample throughput (3 minutes per analysis), low sample consumption and good trueness and precision for the analyzed elements. Sample preparation is reduced to ashing the samples in a muffle furnace. Furthermore, measurements are possible regardless of the chemical form in the additives. For verification the results obtained with the developed method were compared with measurement results of independent methods ICP-MS/OES after digestion. In addition Cd, Cr and Pb were determined in a solid plastic reference material BAM-H010 to confirm the applicability and accuracy of the method.</description><subject>Additives</subject><subject>Chromium</subject><subject>Inductively coupled plasma</subject><subject>Iron</subject><subject>Optical emission spectroscopy</subject><subject>Polyethylenes</subject><subject>Vaporization</subject><issn>0267-9477</issn><issn>1364-5544</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNqVjUlOxDAQRS0EEs2w4QResgk4iZOQNYM4APtWyalAtTzhciKFm3BbTIsLsPqb994X4qZWd7Vqx3ujD6CU1s18InZ12-uq67Q-FTvV9EM16mE4FxfMB1Wgrul24vuJEpos3WIzVWjRoc8SPNiNiWWYZbTAmYx0kDERWJYrAQdLk2Rw0ZJ_l8UzOYX8gcmBlSvEkOgLMgUvyU-LybSi3aQJS7Q4HZsOZIglXHh0xPzLcjx22IS4XYmzubzh9d9eituX57fH1yqm8Lkg532xDFoLHsPC-7ofG63G4aFt_4H-AJ0VZvk</recordid><startdate>20150401</startdate><enddate>20150401</enddate><creator>Borno, F</creator><creator>Richter, S</creator><creator>Deiting, D</creator><creator>Jakubowski, N</creator><creator>Panne, U</creator><scope>7SR</scope><scope>7U5</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope></search><sort><creationdate>20150401</creationdate><title>Direct multi-element analysis of plastic materials viasolid sampling electrothermal vaporization inductively coupled plasma optical emission spectroscopy</title><author>Borno, F ; Richter, S ; Deiting, D ; Jakubowski, N ; Panne, U</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_16924097833</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Additives</topic><topic>Chromium</topic><topic>Inductively coupled plasma</topic><topic>Iron</topic><topic>Optical emission spectroscopy</topic><topic>Polyethylenes</topic><topic>Vaporization</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Borno, F</creatorcontrib><creatorcontrib>Richter, S</creatorcontrib><creatorcontrib>Deiting, D</creatorcontrib><creatorcontrib>Jakubowski, N</creatorcontrib><creatorcontrib>Panne, U</creatorcontrib><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of analytical atomic spectrometry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Borno, F</au><au>Richter, S</au><au>Deiting, D</au><au>Jakubowski, N</au><au>Panne, U</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Direct multi-element analysis of plastic materials viasolid sampling electrothermal vaporization inductively coupled plasma optical emission spectroscopy</atitle><jtitle>Journal of analytical atomic spectrometry</jtitle><date>2015-04-01</date><risdate>2015</risdate><volume>30</volume><issue>5</issue><spage>1064</spage><epage>1071</epage><pages>1064-1071</pages><issn>0267-9477</issn><eissn>1364-5544</eissn><abstract>In this work the determination of Cd, Cu, Cr, Fe and Sb as organic and inorganic additives in in-house plastic materials (ABS, LDPE) using electrothermal vaporization combined with inductively coupled plasma optical emission spectroscopy is described. The influence of CCl sub(2)F sub(2) as gaseous halogenation modifier was investigated. Especially for the carbide forming elements the sensitivity was improved and the memory effects were significantly reduced. Calibration was performed by external calibration and standard addition with aqueous standard solutions added directly into the sample boats. Absolute limits of detection (3s-criterion) range between 0.1 ng (Cd) and 9 ng (Fe) which corresponds to relative values of 0.1 mg kg super(-1) and 1.6 mg kg super(-1), respectively, taking 5 mg as typical sample mass. The detection limits are sufficient to monitor the element contents of plastic materials according to European directives such as European directive on the safety of toys. The developed ETV-ICP-OES method allows a fast analysis with a high sample throughput (3 minutes per analysis), low sample consumption and good trueness and precision for the analyzed elements. Sample preparation is reduced to ashing the samples in a muffle furnace. Furthermore, measurements are possible regardless of the chemical form in the additives. For verification the results obtained with the developed method were compared with measurement results of independent methods ICP-MS/OES after digestion. In addition Cd, Cr and Pb were determined in a solid plastic reference material BAM-H010 to confirm the applicability and accuracy of the method.</abstract><doi>10.1039/c4ja00442f</doi></addata></record>
fulltext fulltext
identifier ISSN: 0267-9477
ispartof Journal of analytical atomic spectrometry, 2015-04, Vol.30 (5), p.1064-1071
issn 0267-9477
1364-5544
language eng
recordid cdi_proquest_miscellaneous_1692409783
source Royal Society Of Chemistry Journals 2008-; Alma/SFX Local Collection
subjects Additives
Chromium
Inductively coupled plasma
Iron
Optical emission spectroscopy
Polyethylenes
Vaporization
title Direct multi-element analysis of plastic materials viasolid sampling electrothermal vaporization inductively coupled plasma optical emission spectroscopy
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T16%3A22%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Direct%20multi-element%20analysis%20of%20plastic%20materials%20viasolid%20sampling%20electrothermal%20vaporization%20inductively%20coupled%20plasma%20optical%20emission%20spectroscopy&rft.jtitle=Journal%20of%20analytical%20atomic%20spectrometry&rft.au=Borno,%20F&rft.date=2015-04-01&rft.volume=30&rft.issue=5&rft.spage=1064&rft.epage=1071&rft.pages=1064-1071&rft.issn=0267-9477&rft.eissn=1364-5544&rft_id=info:doi/10.1039/c4ja00442f&rft_dat=%3Cproquest%3E1692409783%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1692409783&rft_id=info:pmid/&rfr_iscdi=true