Experimental Study of Current Loss of Stainless Steel Magnetically Insulated Transmission Line with Current Density at MA/cm Level

A magnetically insulated transmission line (MITL) is used to transmit high power electric pulses in large pulse power systems. However, current loss is unavoidable, especially when the current density is up to 1 MA/cm. In the paper, the current loss of an MITL made of stainless steel, which is usual...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Plasma science & technology 2014-06, Vol.16 (6), p.625-628
1. Verfasser: 吴撼宇 曾正中 王亮平 郭宁
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 628
container_issue 6
container_start_page 625
container_title Plasma science & technology
container_volume 16
creator 吴撼宇 曾正中 王亮平 郭宁
description A magnetically insulated transmission line (MITL) is used to transmit high power electric pulses in large pulse power systems. However, current loss is unavoidable, especially when the current density is up to 1 MA/cm. In the paper, the current loss of an MITL made of stainless steel, which is usually used in large pulse power generators, is experimentally studied, and possible mechanisms to explain the current loss of the MITL are analyzed and discussed. From the experimental results, the relationship between loss current density and input current density follows approximately a power law. The loss is also related to the configuration of the MITL.
doi_str_mv 10.1088/1009-0630/16/6/16
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1692368185</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><cqvip_id>49943476</cqvip_id><sourcerecordid>1692368185</sourcerecordid><originalsourceid>FETCH-LOGICAL-c304t-868f61e019410189818657cba19e8b7703cf1e305dacbf020a9bc788bd6556bd3</originalsourceid><addsrcrecordid>eNo9kDFPwzAQhTOARCn8ADazsZTYdeLYY1UKVErF0DJHjnNpjVynjR0gK78cR6263Ok93Xs6fVH0QPAzwZzHBGMxwYzimLCYhXEVjS7eTXTr3BfGaSI4HUV_i98DtHoP1kuD1r6retTUaN61bbBQ3jg36LWX2hoIYu0BDFrJrQWvlTSmR0vrOiM9VGjTSuv22jndWJRrC-hH-92l7QWs075H0qPVLFZ7lMM3mLvoupbGwf15j6PP18Vm_j7JP96W81k-URQnfsIZrxkBTERCMOGCE87STJWSCOBllmGqagIUp5VUZY2nWIpSZZyXFUtTVlZ0HD2deg9tc-zA-SJ8qsAYaaHpXEGYmFIWatNwSk6nqg0AWqiLQ2Ak274guBgYFwPPYuAZYgULI2Qez5ldY7dHbbeXUCJEQpOM0X_d7H2D</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1692368185</pqid></control><display><type>article</type><title>Experimental Study of Current Loss of Stainless Steel Magnetically Insulated Transmission Line with Current Density at MA/cm Level</title><source>IOP Publishing Journals</source><creator>吴撼宇 曾正中 王亮平 郭宁</creator><creatorcontrib>吴撼宇 曾正中 王亮平 郭宁</creatorcontrib><description>A magnetically insulated transmission line (MITL) is used to transmit high power electric pulses in large pulse power systems. However, current loss is unavoidable, especially when the current density is up to 1 MA/cm. In the paper, the current loss of an MITL made of stainless steel, which is usually used in large pulse power generators, is experimentally studied, and possible mechanisms to explain the current loss of the MITL are analyzed and discussed. From the experimental results, the relationship between loss current density and input current density follows approximately a power law. The loss is also related to the configuration of the MITL.</description><identifier>ISSN: 1009-0630</identifier><identifier>DOI: 10.1088/1009-0630/16/6/16</identifier><language>eng</language><subject>Current density ; Current loss ; Electric power generation ; Electric pulses ; Generators ; Power law ; Stainless steels ; Transmission lines ; 不锈钢 ; 厘米级 ; 实验 ; 平方 ; 损耗 ; 电流密度 ; 磁绝缘传输线 ; 绝缘线</subject><ispartof>Plasma science &amp; technology, 2014-06, Vol.16 (6), p.625-628</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c304t-868f61e019410189818657cba19e8b7703cf1e305dacbf020a9bc788bd6556bd3</citedby><cites>FETCH-LOGICAL-c304t-868f61e019410189818657cba19e8b7703cf1e305dacbf020a9bc788bd6556bd3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttp://image.cqvip.com/vip1000/qk/84262X/84262X.jpg</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids></links><search><creatorcontrib>吴撼宇 曾正中 王亮平 郭宁</creatorcontrib><title>Experimental Study of Current Loss of Stainless Steel Magnetically Insulated Transmission Line with Current Density at MA/cm Level</title><title>Plasma science &amp; technology</title><addtitle>Plasma Science & Technology</addtitle><description>A magnetically insulated transmission line (MITL) is used to transmit high power electric pulses in large pulse power systems. However, current loss is unavoidable, especially when the current density is up to 1 MA/cm. In the paper, the current loss of an MITL made of stainless steel, which is usually used in large pulse power generators, is experimentally studied, and possible mechanisms to explain the current loss of the MITL are analyzed and discussed. From the experimental results, the relationship between loss current density and input current density follows approximately a power law. The loss is also related to the configuration of the MITL.</description><subject>Current density</subject><subject>Current loss</subject><subject>Electric power generation</subject><subject>Electric pulses</subject><subject>Generators</subject><subject>Power law</subject><subject>Stainless steels</subject><subject>Transmission lines</subject><subject>不锈钢</subject><subject>厘米级</subject><subject>实验</subject><subject>平方</subject><subject>损耗</subject><subject>电流密度</subject><subject>磁绝缘传输线</subject><subject>绝缘线</subject><issn>1009-0630</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNo9kDFPwzAQhTOARCn8ADazsZTYdeLYY1UKVErF0DJHjnNpjVynjR0gK78cR6263Ok93Xs6fVH0QPAzwZzHBGMxwYzimLCYhXEVjS7eTXTr3BfGaSI4HUV_i98DtHoP1kuD1r6retTUaN61bbBQ3jg36LWX2hoIYu0BDFrJrQWvlTSmR0vrOiM9VGjTSuv22jndWJRrC-hH-92l7QWs075H0qPVLFZ7lMM3mLvoupbGwf15j6PP18Vm_j7JP96W81k-URQnfsIZrxkBTERCMOGCE87STJWSCOBllmGqagIUp5VUZY2nWIpSZZyXFUtTVlZ0HD2deg9tc-zA-SJ8qsAYaaHpXEGYmFIWatNwSk6nqg0AWqiLQ2Ak274guBgYFwPPYuAZYgULI2Qez5ldY7dHbbeXUCJEQpOM0X_d7H2D</recordid><startdate>20140601</startdate><enddate>20140601</enddate><creator>吴撼宇 曾正中 王亮平 郭宁</creator><scope>2RA</scope><scope>92L</scope><scope>CQIGP</scope><scope>W92</scope><scope>~WA</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>H8D</scope><scope>JG9</scope><scope>L7M</scope></search><sort><creationdate>20140601</creationdate><title>Experimental Study of Current Loss of Stainless Steel Magnetically Insulated Transmission Line with Current Density at MA/cm Level</title><author>吴撼宇 曾正中 王亮平 郭宁</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c304t-868f61e019410189818657cba19e8b7703cf1e305dacbf020a9bc788bd6556bd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Current density</topic><topic>Current loss</topic><topic>Electric power generation</topic><topic>Electric pulses</topic><topic>Generators</topic><topic>Power law</topic><topic>Stainless steels</topic><topic>Transmission lines</topic><topic>不锈钢</topic><topic>厘米级</topic><topic>实验</topic><topic>平方</topic><topic>损耗</topic><topic>电流密度</topic><topic>磁绝缘传输线</topic><topic>绝缘线</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>吴撼宇 曾正中 王亮平 郭宁</creatorcontrib><collection>中文科技期刊数据库</collection><collection>中文科技期刊数据库-CALIS站点</collection><collection>中文科技期刊数据库-7.0平台</collection><collection>中文科技期刊数据库-工程技术</collection><collection>中文科技期刊数据库- 镜像站点</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Plasma science &amp; technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>吴撼宇 曾正中 王亮平 郭宁</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Experimental Study of Current Loss of Stainless Steel Magnetically Insulated Transmission Line with Current Density at MA/cm Level</atitle><jtitle>Plasma science &amp; technology</jtitle><addtitle>Plasma Science & Technology</addtitle><date>2014-06-01</date><risdate>2014</risdate><volume>16</volume><issue>6</issue><spage>625</spage><epage>628</epage><pages>625-628</pages><issn>1009-0630</issn><abstract>A magnetically insulated transmission line (MITL) is used to transmit high power electric pulses in large pulse power systems. However, current loss is unavoidable, especially when the current density is up to 1 MA/cm. In the paper, the current loss of an MITL made of stainless steel, which is usually used in large pulse power generators, is experimentally studied, and possible mechanisms to explain the current loss of the MITL are analyzed and discussed. From the experimental results, the relationship between loss current density and input current density follows approximately a power law. The loss is also related to the configuration of the MITL.</abstract><doi>10.1088/1009-0630/16/6/16</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1009-0630
ispartof Plasma science & technology, 2014-06, Vol.16 (6), p.625-628
issn 1009-0630
language eng
recordid cdi_proquest_miscellaneous_1692368185
source IOP Publishing Journals
subjects Current density
Current loss
Electric power generation
Electric pulses
Generators
Power law
Stainless steels
Transmission lines
不锈钢
厘米级
实验
平方
损耗
电流密度
磁绝缘传输线
绝缘线
title Experimental Study of Current Loss of Stainless Steel Magnetically Insulated Transmission Line with Current Density at MA/cm Level
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T09%3A50%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Experimental%20Study%20of%20Current%20Loss%20of%20Stainless%20Steel%20Magnetically%20Insulated%20Transmission%20Line%20with%20Current%20Density%20at%20MA/cm%20Level&rft.jtitle=Plasma%20science%20&%20technology&rft.au=%E5%90%B4%E6%92%BC%E5%AE%87%20%E6%9B%BE%E6%AD%A3%E4%B8%AD%20%E7%8E%8B%E4%BA%AE%E5%B9%B3%20%E9%83%AD%E5%AE%81&rft.date=2014-06-01&rft.volume=16&rft.issue=6&rft.spage=625&rft.epage=628&rft.pages=625-628&rft.issn=1009-0630&rft_id=info:doi/10.1088/1009-0630/16/6/16&rft_dat=%3Cproquest_cross%3E1692368185%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1692368185&rft_id=info:pmid/&rft_cqvip_id=49943476&rfr_iscdi=true