Experimental Study of Current Loss of Stainless Steel Magnetically Insulated Transmission Line with Current Density at MA/cm Level
A magnetically insulated transmission line (MITL) is used to transmit high power electric pulses in large pulse power systems. However, current loss is unavoidable, especially when the current density is up to 1 MA/cm. In the paper, the current loss of an MITL made of stainless steel, which is usual...
Gespeichert in:
Veröffentlicht in: | Plasma science & technology 2014-06, Vol.16 (6), p.625-628 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 628 |
---|---|
container_issue | 6 |
container_start_page | 625 |
container_title | Plasma science & technology |
container_volume | 16 |
creator | 吴撼宇 曾正中 王亮平 郭宁 |
description | A magnetically insulated transmission line (MITL) is used to transmit high power electric pulses in large pulse power systems. However, current loss is unavoidable, especially when the current density is up to 1 MA/cm. In the paper, the current loss of an MITL made of stainless steel, which is usually used in large pulse power generators, is experimentally studied, and possible mechanisms to explain the current loss of the MITL are analyzed and discussed. From the experimental results, the relationship between loss current density and input current density follows approximately a power law. The loss is also related to the configuration of the MITL. |
doi_str_mv | 10.1088/1009-0630/16/6/16 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1692368185</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><cqvip_id>49943476</cqvip_id><sourcerecordid>1692368185</sourcerecordid><originalsourceid>FETCH-LOGICAL-c304t-868f61e019410189818657cba19e8b7703cf1e305dacbf020a9bc788bd6556bd3</originalsourceid><addsrcrecordid>eNo9kDFPwzAQhTOARCn8ADazsZTYdeLYY1UKVErF0DJHjnNpjVynjR0gK78cR6263Ok93Xs6fVH0QPAzwZzHBGMxwYzimLCYhXEVjS7eTXTr3BfGaSI4HUV_i98DtHoP1kuD1r6retTUaN61bbBQ3jg36LWX2hoIYu0BDFrJrQWvlTSmR0vrOiM9VGjTSuv22jndWJRrC-hH-92l7QWs075H0qPVLFZ7lMM3mLvoupbGwf15j6PP18Vm_j7JP96W81k-URQnfsIZrxkBTERCMOGCE87STJWSCOBllmGqagIUp5VUZY2nWIpSZZyXFUtTVlZ0HD2deg9tc-zA-SJ8qsAYaaHpXEGYmFIWatNwSk6nqg0AWqiLQ2Ak274guBgYFwPPYuAZYgULI2Qez5ldY7dHbbeXUCJEQpOM0X_d7H2D</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1692368185</pqid></control><display><type>article</type><title>Experimental Study of Current Loss of Stainless Steel Magnetically Insulated Transmission Line with Current Density at MA/cm Level</title><source>IOP Publishing Journals</source><creator>吴撼宇 曾正中 王亮平 郭宁</creator><creatorcontrib>吴撼宇 曾正中 王亮平 郭宁</creatorcontrib><description>A magnetically insulated transmission line (MITL) is used to transmit high power electric pulses in large pulse power systems. However, current loss is unavoidable, especially when the current density is up to 1 MA/cm. In the paper, the current loss of an MITL made of stainless steel, which is usually used in large pulse power generators, is experimentally studied, and possible mechanisms to explain the current loss of the MITL are analyzed and discussed. From the experimental results, the relationship between loss current density and input current density follows approximately a power law. The loss is also related to the configuration of the MITL.</description><identifier>ISSN: 1009-0630</identifier><identifier>DOI: 10.1088/1009-0630/16/6/16</identifier><language>eng</language><subject>Current density ; Current loss ; Electric power generation ; Electric pulses ; Generators ; Power law ; Stainless steels ; Transmission lines ; 不锈钢 ; 厘米级 ; 实验 ; 平方 ; 损耗 ; 电流密度 ; 磁绝缘传输线 ; 绝缘线</subject><ispartof>Plasma science & technology, 2014-06, Vol.16 (6), p.625-628</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c304t-868f61e019410189818657cba19e8b7703cf1e305dacbf020a9bc788bd6556bd3</citedby><cites>FETCH-LOGICAL-c304t-868f61e019410189818657cba19e8b7703cf1e305dacbf020a9bc788bd6556bd3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttp://image.cqvip.com/vip1000/qk/84262X/84262X.jpg</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids></links><search><creatorcontrib>吴撼宇 曾正中 王亮平 郭宁</creatorcontrib><title>Experimental Study of Current Loss of Stainless Steel Magnetically Insulated Transmission Line with Current Density at MA/cm Level</title><title>Plasma science & technology</title><addtitle>Plasma Science & Technology</addtitle><description>A magnetically insulated transmission line (MITL) is used to transmit high power electric pulses in large pulse power systems. However, current loss is unavoidable, especially when the current density is up to 1 MA/cm. In the paper, the current loss of an MITL made of stainless steel, which is usually used in large pulse power generators, is experimentally studied, and possible mechanisms to explain the current loss of the MITL are analyzed and discussed. From the experimental results, the relationship between loss current density and input current density follows approximately a power law. The loss is also related to the configuration of the MITL.</description><subject>Current density</subject><subject>Current loss</subject><subject>Electric power generation</subject><subject>Electric pulses</subject><subject>Generators</subject><subject>Power law</subject><subject>Stainless steels</subject><subject>Transmission lines</subject><subject>不锈钢</subject><subject>厘米级</subject><subject>实验</subject><subject>平方</subject><subject>损耗</subject><subject>电流密度</subject><subject>磁绝缘传输线</subject><subject>绝缘线</subject><issn>1009-0630</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNo9kDFPwzAQhTOARCn8ADazsZTYdeLYY1UKVErF0DJHjnNpjVynjR0gK78cR6263Ok93Xs6fVH0QPAzwZzHBGMxwYzimLCYhXEVjS7eTXTr3BfGaSI4HUV_i98DtHoP1kuD1r6retTUaN61bbBQ3jg36LWX2hoIYu0BDFrJrQWvlTSmR0vrOiM9VGjTSuv22jndWJRrC-hH-92l7QWs075H0qPVLFZ7lMM3mLvoupbGwf15j6PP18Vm_j7JP96W81k-URQnfsIZrxkBTERCMOGCE87STJWSCOBllmGqagIUp5VUZY2nWIpSZZyXFUtTVlZ0HD2deg9tc-zA-SJ8qsAYaaHpXEGYmFIWatNwSk6nqg0AWqiLQ2Ak274guBgYFwPPYuAZYgULI2Qez5ldY7dHbbeXUCJEQpOM0X_d7H2D</recordid><startdate>20140601</startdate><enddate>20140601</enddate><creator>吴撼宇 曾正中 王亮平 郭宁</creator><scope>2RA</scope><scope>92L</scope><scope>CQIGP</scope><scope>W92</scope><scope>~WA</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>H8D</scope><scope>JG9</scope><scope>L7M</scope></search><sort><creationdate>20140601</creationdate><title>Experimental Study of Current Loss of Stainless Steel Magnetically Insulated Transmission Line with Current Density at MA/cm Level</title><author>吴撼宇 曾正中 王亮平 郭宁</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c304t-868f61e019410189818657cba19e8b7703cf1e305dacbf020a9bc788bd6556bd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Current density</topic><topic>Current loss</topic><topic>Electric power generation</topic><topic>Electric pulses</topic><topic>Generators</topic><topic>Power law</topic><topic>Stainless steels</topic><topic>Transmission lines</topic><topic>不锈钢</topic><topic>厘米级</topic><topic>实验</topic><topic>平方</topic><topic>损耗</topic><topic>电流密度</topic><topic>磁绝缘传输线</topic><topic>绝缘线</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>吴撼宇 曾正中 王亮平 郭宁</creatorcontrib><collection>中文科技期刊数据库</collection><collection>中文科技期刊数据库-CALIS站点</collection><collection>中文科技期刊数据库-7.0平台</collection><collection>中文科技期刊数据库-工程技术</collection><collection>中文科技期刊数据库- 镜像站点</collection><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Plasma science & technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>吴撼宇 曾正中 王亮平 郭宁</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Experimental Study of Current Loss of Stainless Steel Magnetically Insulated Transmission Line with Current Density at MA/cm Level</atitle><jtitle>Plasma science & technology</jtitle><addtitle>Plasma Science & Technology</addtitle><date>2014-06-01</date><risdate>2014</risdate><volume>16</volume><issue>6</issue><spage>625</spage><epage>628</epage><pages>625-628</pages><issn>1009-0630</issn><abstract>A magnetically insulated transmission line (MITL) is used to transmit high power electric pulses in large pulse power systems. However, current loss is unavoidable, especially when the current density is up to 1 MA/cm. In the paper, the current loss of an MITL made of stainless steel, which is usually used in large pulse power generators, is experimentally studied, and possible mechanisms to explain the current loss of the MITL are analyzed and discussed. From the experimental results, the relationship between loss current density and input current density follows approximately a power law. The loss is also related to the configuration of the MITL.</abstract><doi>10.1088/1009-0630/16/6/16</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1009-0630 |
ispartof | Plasma science & technology, 2014-06, Vol.16 (6), p.625-628 |
issn | 1009-0630 |
language | eng |
recordid | cdi_proquest_miscellaneous_1692368185 |
source | IOP Publishing Journals |
subjects | Current density Current loss Electric power generation Electric pulses Generators Power law Stainless steels Transmission lines 不锈钢 厘米级 实验 平方 损耗 电流密度 磁绝缘传输线 绝缘线 |
title | Experimental Study of Current Loss of Stainless Steel Magnetically Insulated Transmission Line with Current Density at MA/cm Level |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T09%3A50%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Experimental%20Study%20of%20Current%20Loss%20of%20Stainless%20Steel%20Magnetically%20Insulated%20Transmission%20Line%20with%20Current%20Density%20at%20MA/cm%20Level&rft.jtitle=Plasma%20science%20&%20technology&rft.au=%E5%90%B4%E6%92%BC%E5%AE%87%20%E6%9B%BE%E6%AD%A3%E4%B8%AD%20%E7%8E%8B%E4%BA%AE%E5%B9%B3%20%E9%83%AD%E5%AE%81&rft.date=2014-06-01&rft.volume=16&rft.issue=6&rft.spage=625&rft.epage=628&rft.pages=625-628&rft.issn=1009-0630&rft_id=info:doi/10.1088/1009-0630/16/6/16&rft_dat=%3Cproquest_cross%3E1692368185%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1692368185&rft_id=info:pmid/&rft_cqvip_id=49943476&rfr_iscdi=true |