Measurement of Shock Wave Pressure Distribution of Extracorporeal Shock Wave Lithotripter Using Pressure-Sensitive Paper: Practical Usefulness and Limitations
A new method for evaluating shock wave pressure distribution of extracorporeal shock wave lithotripters, using pressure-sensitive paper has been developed. It is a simple method to visualize the shock wave pressure distribution and has a better spatial resolution than the hydrophone. The pressure-se...
Gespeichert in:
Veröffentlicht in: | Japanese Journal of Applied Physics 1994, Vol.33 (5S), p.3155-3158 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 3158 |
---|---|
container_issue | 5S |
container_start_page | 3155 |
container_title | Japanese Journal of Applied Physics |
container_volume | 33 |
creator | Oyanagi, Masamichi Kudo, Nobuki Yanagida, Yuji Nobuyuki Iwama, Nobuyuki Iwama Kiyoshi Okazaki, Kiyoshi Okazaki |
description | A new method for evaluating shock wave pressure distribution of extracorporeal shock wave lithotripters, using pressure-sensitive paper has been developed. It is a simple method to visualize the shock wave pressure distribution and has a better spatial resolution than the hydrophone. The pressure-sensitive paper can be used to visually detect whether the focal point is on the correct position, and to detect changes of pressure distribution. Additionally, the relationship between lithotripter power and integrated density as a new evaluating value shows linearity. Therefore, this method is useful for quality assurance of lithotripters at hospitals. |
doi_str_mv | 10.1143/JJAP.33.3155 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_16919308</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>16919308</sourcerecordid><originalsourceid>FETCH-LOGICAL-c387t-32eb07eec4f539b7e567de3c42a6010eaf2445f190e06996fe61d76297f9a1783</originalsourceid><addsrcrecordid>eNpNkctOwzAQRS0EEqWw4wOyYkWKHTt2za4q5VEVUalULCPXHVNDEgfbQfAzfCuJQIjVaHTPnFlchE4JHhHC6MV8PlmOKB1Rkud7aEAoEynDPN9HA4wzkjKZZYfoKISXbuU5IwP0dQ8qtB4qqGPiTLLaOf2aPKl3SJYeQh8lVzZEbzdttK7umdlH9Eo73zgPqvx_srBx5zq2ieCTdbD1858lXUEdbLS9WDXgL7tE6Wh1Z1gHMG1Zd2Ci6m1nqWxU_bdwjA6MKgOc_M4hWl_PHqe36eLh5m46WaSajkVMaQYbLAA0MzmVGwE5F1ugmmWKY4JBmYyx3BCJAXMpuQFOtoJnUhipiBjTITr78TbevbUQYlHZoKEsVQ2uDQXhkkiKe_D8B9TeheDBFI23lfKfBcFFX0LRl1BQWvQl0G_vJn3W</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>16919308</pqid></control><display><type>article</type><title>Measurement of Shock Wave Pressure Distribution of Extracorporeal Shock Wave Lithotripter Using Pressure-Sensitive Paper: Practical Usefulness and Limitations</title><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Oyanagi, Masamichi ; Kudo, Nobuki ; Yanagida, Yuji ; Nobuyuki Iwama, Nobuyuki Iwama ; Kiyoshi Okazaki, Kiyoshi Okazaki</creator><creatorcontrib>Oyanagi, Masamichi ; Kudo, Nobuki ; Yanagida, Yuji ; Nobuyuki Iwama, Nobuyuki Iwama ; Kiyoshi Okazaki, Kiyoshi Okazaki</creatorcontrib><description>A new method for evaluating shock wave pressure distribution of extracorporeal shock wave lithotripters, using pressure-sensitive paper has been developed. It is a simple method to visualize the shock wave pressure distribution and has a better spatial resolution than the hydrophone. The pressure-sensitive paper can be used to visually detect whether the focal point is on the correct position, and to detect changes of pressure distribution. Additionally, the relationship between lithotripter power and integrated density as a new evaluating value shows linearity. Therefore, this method is useful for quality assurance of lithotripters at hospitals.</description><identifier>ISSN: 0021-4922</identifier><identifier>EISSN: 1347-4065</identifier><identifier>DOI: 10.1143/JJAP.33.3155</identifier><language>eng</language><ispartof>Japanese Journal of Applied Physics, 1994, Vol.33 (5S), p.3155-3158</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c387t-32eb07eec4f539b7e567de3c42a6010eaf2445f190e06996fe61d76297f9a1783</citedby><cites>FETCH-LOGICAL-c387t-32eb07eec4f539b7e567de3c42a6010eaf2445f190e06996fe61d76297f9a1783</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,4010,27904,27905,27906</link.rule.ids></links><search><creatorcontrib>Oyanagi, Masamichi</creatorcontrib><creatorcontrib>Kudo, Nobuki</creatorcontrib><creatorcontrib>Yanagida, Yuji</creatorcontrib><creatorcontrib>Nobuyuki Iwama, Nobuyuki Iwama</creatorcontrib><creatorcontrib>Kiyoshi Okazaki, Kiyoshi Okazaki</creatorcontrib><title>Measurement of Shock Wave Pressure Distribution of Extracorporeal Shock Wave Lithotripter Using Pressure-Sensitive Paper: Practical Usefulness and Limitations</title><title>Japanese Journal of Applied Physics</title><description>A new method for evaluating shock wave pressure distribution of extracorporeal shock wave lithotripters, using pressure-sensitive paper has been developed. It is a simple method to visualize the shock wave pressure distribution and has a better spatial resolution than the hydrophone. The pressure-sensitive paper can be used to visually detect whether the focal point is on the correct position, and to detect changes of pressure distribution. Additionally, the relationship between lithotripter power and integrated density as a new evaluating value shows linearity. Therefore, this method is useful for quality assurance of lithotripters at hospitals.</description><issn>0021-4922</issn><issn>1347-4065</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1994</creationdate><recordtype>article</recordtype><recordid>eNpNkctOwzAQRS0EEqWw4wOyYkWKHTt2za4q5VEVUalULCPXHVNDEgfbQfAzfCuJQIjVaHTPnFlchE4JHhHC6MV8PlmOKB1Rkud7aEAoEynDPN9HA4wzkjKZZYfoKISXbuU5IwP0dQ8qtB4qqGPiTLLaOf2aPKl3SJYeQh8lVzZEbzdttK7umdlH9Eo73zgPqvx_srBx5zq2ieCTdbD1858lXUEdbLS9WDXgL7tE6Wh1Z1gHMG1Zd2Ci6m1nqWxU_bdwjA6MKgOc_M4hWl_PHqe36eLh5m46WaSajkVMaQYbLAA0MzmVGwE5F1ugmmWKY4JBmYyx3BCJAXMpuQFOtoJnUhipiBjTITr78TbevbUQYlHZoKEsVQ2uDQXhkkiKe_D8B9TeheDBFI23lfKfBcFFX0LRl1BQWvQl0G_vJn3W</recordid><startdate>1994</startdate><enddate>1994</enddate><creator>Oyanagi, Masamichi</creator><creator>Kudo, Nobuki</creator><creator>Yanagida, Yuji</creator><creator>Nobuyuki Iwama, Nobuyuki Iwama</creator><creator>Kiyoshi Okazaki, Kiyoshi Okazaki</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope></search><sort><creationdate>1994</creationdate><title>Measurement of Shock Wave Pressure Distribution of Extracorporeal Shock Wave Lithotripter Using Pressure-Sensitive Paper: Practical Usefulness and Limitations</title><author>Oyanagi, Masamichi ; Kudo, Nobuki ; Yanagida, Yuji ; Nobuyuki Iwama, Nobuyuki Iwama ; Kiyoshi Okazaki, Kiyoshi Okazaki</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c387t-32eb07eec4f539b7e567de3c42a6010eaf2445f190e06996fe61d76297f9a1783</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1994</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Oyanagi, Masamichi</creatorcontrib><creatorcontrib>Kudo, Nobuki</creatorcontrib><creatorcontrib>Yanagida, Yuji</creatorcontrib><creatorcontrib>Nobuyuki Iwama, Nobuyuki Iwama</creatorcontrib><creatorcontrib>Kiyoshi Okazaki, Kiyoshi Okazaki</creatorcontrib><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Japanese Journal of Applied Physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Oyanagi, Masamichi</au><au>Kudo, Nobuki</au><au>Yanagida, Yuji</au><au>Nobuyuki Iwama, Nobuyuki Iwama</au><au>Kiyoshi Okazaki, Kiyoshi Okazaki</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Measurement of Shock Wave Pressure Distribution of Extracorporeal Shock Wave Lithotripter Using Pressure-Sensitive Paper: Practical Usefulness and Limitations</atitle><jtitle>Japanese Journal of Applied Physics</jtitle><date>1994</date><risdate>1994</risdate><volume>33</volume><issue>5S</issue><spage>3155</spage><epage>3158</epage><pages>3155-3158</pages><issn>0021-4922</issn><eissn>1347-4065</eissn><abstract>A new method for evaluating shock wave pressure distribution of extracorporeal shock wave lithotripters, using pressure-sensitive paper has been developed. It is a simple method to visualize the shock wave pressure distribution and has a better spatial resolution than the hydrophone. The pressure-sensitive paper can be used to visually detect whether the focal point is on the correct position, and to detect changes of pressure distribution. Additionally, the relationship between lithotripter power and integrated density as a new evaluating value shows linearity. Therefore, this method is useful for quality assurance of lithotripters at hospitals.</abstract><doi>10.1143/JJAP.33.3155</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0021-4922 |
ispartof | Japanese Journal of Applied Physics, 1994, Vol.33 (5S), p.3155-3158 |
issn | 0021-4922 1347-4065 |
language | eng |
recordid | cdi_proquest_miscellaneous_16919308 |
source | IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link |
title | Measurement of Shock Wave Pressure Distribution of Extracorporeal Shock Wave Lithotripter Using Pressure-Sensitive Paper: Practical Usefulness and Limitations |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T21%3A20%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Measurement%20of%20Shock%20Wave%20Pressure%20Distribution%20of%20Extracorporeal%20Shock%20Wave%20Lithotripter%20Using%20Pressure-Sensitive%20Paper:%20Practical%20Usefulness%20and%20Limitations&rft.jtitle=Japanese%20Journal%20of%20Applied%20Physics&rft.au=Oyanagi,%20Masamichi&rft.date=1994&rft.volume=33&rft.issue=5S&rft.spage=3155&rft.epage=3158&rft.pages=3155-3158&rft.issn=0021-4922&rft.eissn=1347-4065&rft_id=info:doi/10.1143/JJAP.33.3155&rft_dat=%3Cproquest_cross%3E16919308%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=16919308&rft_id=info:pmid/&rfr_iscdi=true |