Performance of an indirect evaporative cooler in Athens

The performance of an indirect evaporative cooler provided with a flat plate heat exchanger was studied by simulating its operation in a typical building, using the weather conditions of Athens. Simulations were performed with the TRNSYS code. The results were the temperatures at the outlet of the c...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Energy and buildings 1994, Vol.21 (1), p.55-63
Hauptverfasser: Klitsikas, N., Santamouris, M., Argiriou, A., Asimakopoulos, D.N., Dounis, A.I.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 63
container_issue 1
container_start_page 55
container_title Energy and buildings
container_volume 21
creator Klitsikas, N.
Santamouris, M.
Argiriou, A.
Asimakopoulos, D.N.
Dounis, A.I.
description The performance of an indirect evaporative cooler provided with a flat plate heat exchanger was studied by simulating its operation in a typical building, using the weather conditions of Athens. Simulations were performed with the TRNSYS code. The results were the temperatures at the outlet of the cooler and inside the building, the comfort hours and the hours of cooler operation per day. The sensitivity of the cooler performance to night ventilation rate and the size of the south window glazing were also investigated. Simulation results showed that the cooler increases the number of comfort hours per day inside the building, since the indoor temperature is significantly lower when the system operates than under free-floating conditions. It was found also that night ventilation increases the comfort hours of the building while reducing the hours of operation of the cooler.
doi_str_mv 10.1016/0378-7788(94)90016-7
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_16910710</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0378778894900167</els_id><sourcerecordid>14355720</sourcerecordid><originalsourceid>FETCH-LOGICAL-c395t-d824e9ec7decfa0d0c394f43c04e34e09ddf588be04a1c406ff8be09ee52ba283</originalsourceid><addsrcrecordid>eNqFkE1LAzEQhnNQsH78Aw97ENHD6mST3SQXoRS_oKAHPYc0O8HIdlOTbcF_b9aWHvU0zDvPzMBDyDmFGwq0uQUmZCmElFeKXyvIUSkOyGQfH5HjlD4BoKkFnRDxitGFuDS9xSK4wvSF71sf0Q4FbswqRDP4DRY2hA5jnhXT4QP7dEoOnekSnu3qCXl_uH-bPZXzl8fn2XReWqbqoWxlxVGhFS1aZ6CFHHPHmQWOjCOotnW1lAsEbqjl0Dg3NgqxrhamkuyEXG7vrmL4WmMa9NIni11negzrpGmjKAgK_4Oc1bWoRpBvQRtDShGdXkW_NPFbU9CjQj260qMrrbj-VahFXrvY3TfJms7FbMyn_S6nqpGMZexui2GWsvEYdbIes9ytU90G__efH7ONhu4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>14355720</pqid></control><display><type>article</type><title>Performance of an indirect evaporative cooler in Athens</title><source>Access via ScienceDirect (Elsevier)</source><creator>Klitsikas, N. ; Santamouris, M. ; Argiriou, A. ; Asimakopoulos, D.N. ; Dounis, A.I.</creator><creatorcontrib>Klitsikas, N. ; Santamouris, M. ; Argiriou, A. ; Asimakopoulos, D.N. ; Dounis, A.I.</creatorcontrib><description>The performance of an indirect evaporative cooler provided with a flat plate heat exchanger was studied by simulating its operation in a typical building, using the weather conditions of Athens. Simulations were performed with the TRNSYS code. The results were the temperatures at the outlet of the cooler and inside the building, the comfort hours and the hours of cooler operation per day. The sensitivity of the cooler performance to night ventilation rate and the size of the south window glazing were also investigated. Simulation results showed that the cooler increases the number of comfort hours per day inside the building, since the indoor temperature is significantly lower when the system operates than under free-floating conditions. It was found also that night ventilation increases the comfort hours of the building while reducing the hours of operation of the cooler.</description><identifier>ISSN: 0378-7788</identifier><identifier>DOI: 10.1016/0378-7788(94)90016-7</identifier><identifier>CODEN: ENEBDR</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Air conditioning systems ; Air conditioning. Ventilation ; Applied sciences ; Buildings ; Energy ; Energy. Thermal use of fuels ; Exact sciences and technology ; Heat exchangers ; Heating, air conditioning and ventilation ; Mathematical models ; Q1</subject><ispartof>Energy and buildings, 1994, Vol.21 (1), p.55-63</ispartof><rights>1994</rights><rights>1994 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c395t-d824e9ec7decfa0d0c394f43c04e34e09ddf588be04a1c406ff8be09ee52ba283</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/0378-7788(94)90016-7$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,4024,27923,27924,27925,45995</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=4196833$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Klitsikas, N.</creatorcontrib><creatorcontrib>Santamouris, M.</creatorcontrib><creatorcontrib>Argiriou, A.</creatorcontrib><creatorcontrib>Asimakopoulos, D.N.</creatorcontrib><creatorcontrib>Dounis, A.I.</creatorcontrib><title>Performance of an indirect evaporative cooler in Athens</title><title>Energy and buildings</title><description>The performance of an indirect evaporative cooler provided with a flat plate heat exchanger was studied by simulating its operation in a typical building, using the weather conditions of Athens. Simulations were performed with the TRNSYS code. The results were the temperatures at the outlet of the cooler and inside the building, the comfort hours and the hours of cooler operation per day. The sensitivity of the cooler performance to night ventilation rate and the size of the south window glazing were also investigated. Simulation results showed that the cooler increases the number of comfort hours per day inside the building, since the indoor temperature is significantly lower when the system operates than under free-floating conditions. It was found also that night ventilation increases the comfort hours of the building while reducing the hours of operation of the cooler.</description><subject>Air conditioning systems</subject><subject>Air conditioning. Ventilation</subject><subject>Applied sciences</subject><subject>Buildings</subject><subject>Energy</subject><subject>Energy. Thermal use of fuels</subject><subject>Exact sciences and technology</subject><subject>Heat exchangers</subject><subject>Heating, air conditioning and ventilation</subject><subject>Mathematical models</subject><subject>Q1</subject><issn>0378-7788</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1994</creationdate><recordtype>article</recordtype><recordid>eNqFkE1LAzEQhnNQsH78Aw97ENHD6mST3SQXoRS_oKAHPYc0O8HIdlOTbcF_b9aWHvU0zDvPzMBDyDmFGwq0uQUmZCmElFeKXyvIUSkOyGQfH5HjlD4BoKkFnRDxitGFuDS9xSK4wvSF71sf0Q4FbswqRDP4DRY2hA5jnhXT4QP7dEoOnekSnu3qCXl_uH-bPZXzl8fn2XReWqbqoWxlxVGhFS1aZ6CFHHPHmQWOjCOotnW1lAsEbqjl0Dg3NgqxrhamkuyEXG7vrmL4WmMa9NIni11negzrpGmjKAgK_4Oc1bWoRpBvQRtDShGdXkW_NPFbU9CjQj260qMrrbj-VahFXrvY3TfJms7FbMyn_S6nqpGMZexui2GWsvEYdbIes9ytU90G__efH7ONhu4</recordid><startdate>1994</startdate><enddate>1994</enddate><creator>Klitsikas, N.</creator><creator>Santamouris, M.</creator><creator>Argiriou, A.</creator><creator>Asimakopoulos, D.N.</creator><creator>Dounis, A.I.</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>C1K</scope><scope>SOI</scope></search><sort><creationdate>1994</creationdate><title>Performance of an indirect evaporative cooler in Athens</title><author>Klitsikas, N. ; Santamouris, M. ; Argiriou, A. ; Asimakopoulos, D.N. ; Dounis, A.I.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c395t-d824e9ec7decfa0d0c394f43c04e34e09ddf588be04a1c406ff8be09ee52ba283</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1994</creationdate><topic>Air conditioning systems</topic><topic>Air conditioning. Ventilation</topic><topic>Applied sciences</topic><topic>Buildings</topic><topic>Energy</topic><topic>Energy. Thermal use of fuels</topic><topic>Exact sciences and technology</topic><topic>Heat exchangers</topic><topic>Heating, air conditioning and ventilation</topic><topic>Mathematical models</topic><topic>Q1</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Klitsikas, N.</creatorcontrib><creatorcontrib>Santamouris, M.</creatorcontrib><creatorcontrib>Argiriou, A.</creatorcontrib><creatorcontrib>Asimakopoulos, D.N.</creatorcontrib><creatorcontrib>Dounis, A.I.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><jtitle>Energy and buildings</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Klitsikas, N.</au><au>Santamouris, M.</au><au>Argiriou, A.</au><au>Asimakopoulos, D.N.</au><au>Dounis, A.I.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Performance of an indirect evaporative cooler in Athens</atitle><jtitle>Energy and buildings</jtitle><date>1994</date><risdate>1994</risdate><volume>21</volume><issue>1</issue><spage>55</spage><epage>63</epage><pages>55-63</pages><issn>0378-7788</issn><coden>ENEBDR</coden><abstract>The performance of an indirect evaporative cooler provided with a flat plate heat exchanger was studied by simulating its operation in a typical building, using the weather conditions of Athens. Simulations were performed with the TRNSYS code. The results were the temperatures at the outlet of the cooler and inside the building, the comfort hours and the hours of cooler operation per day. The sensitivity of the cooler performance to night ventilation rate and the size of the south window glazing were also investigated. Simulation results showed that the cooler increases the number of comfort hours per day inside the building, since the indoor temperature is significantly lower when the system operates than under free-floating conditions. It was found also that night ventilation increases the comfort hours of the building while reducing the hours of operation of the cooler.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><doi>10.1016/0378-7788(94)90016-7</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0378-7788
ispartof Energy and buildings, 1994, Vol.21 (1), p.55-63
issn 0378-7788
language eng
recordid cdi_proquest_miscellaneous_16910710
source Access via ScienceDirect (Elsevier)
subjects Air conditioning systems
Air conditioning. Ventilation
Applied sciences
Buildings
Energy
Energy. Thermal use of fuels
Exact sciences and technology
Heat exchangers
Heating, air conditioning and ventilation
Mathematical models
Q1
title Performance of an indirect evaporative cooler in Athens
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-30T22%3A10%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Performance%20of%20an%20indirect%20evaporative%20cooler%20in%20Athens&rft.jtitle=Energy%20and%20buildings&rft.au=Klitsikas,%20N.&rft.date=1994&rft.volume=21&rft.issue=1&rft.spage=55&rft.epage=63&rft.pages=55-63&rft.issn=0378-7788&rft.coden=ENEBDR&rft_id=info:doi/10.1016/0378-7788(94)90016-7&rft_dat=%3Cproquest_cross%3E14355720%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=14355720&rft_id=info:pmid/&rft_els_id=0378778894900167&rfr_iscdi=true