On the Selection of Test Liquids for the Evaluation of Acid-Base Properties of Solid Surfaces by Contact Angle Goniometry
The determination of the surface free energy (SFE) components from contact angle data using the acid-base (AB) model is often not consistent when various sets of test liquids are utilized. Using contact angle data from the literature, mathematical instabilities of the model are discussed as one of t...
Gespeichert in:
Veröffentlicht in: | Journal of colloid and interface science 1995-02, Vol.169 (2), p.493-496 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 496 |
---|---|
container_issue | 2 |
container_start_page | 493 |
container_title | Journal of colloid and interface science |
container_volume | 169 |
creator | Hollander, A |
description | The determination of the surface free energy (SFE) components from contact angle data using the acid-base (AB) model is often not consistent when various sets of test liquids are utilized. Using contact angle data from the literature, mathematical instabilities of the model are discussed as one of the origins of these inconsistencies. In order to obtain reliable results, the difference of the ratios of the basic and acidic parts of the interfacial free energy of the test liquids should be large. If this condition is not satisfied, small deviations of the measured contact angles (within the range of experimental errors) can produce major differences in the AB components of the SFE. An optimization of the results of several pairs of test liquids can help to obtain reliable results. |
doi_str_mv | 10.1006/jcis.1995.1060 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1688514338</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0021979785710600</els_id><sourcerecordid>1688514338</sourcerecordid><originalsourceid>FETCH-LOGICAL-c414t-c1ca43b4b2f54ba69deaf7341fe3626b0f2fa4aa52d79e330e365af13fa5bf153</originalsourceid><addsrcrecordid>eNp1kDFv2zAQRokiBeqkWTNzyNBFDk8UJXN0jTQJYMAF7M7EiTo2DGTRJqUA_veVamfMRNyHdx9xj7E7EHMQonx4sz7NQWs1jqX4wmYgtMoqEPKKzYTIIdOVrr6x65TehABQSs_YadPx_pX4llqyvQ8dD47vKPV87Y-DbxJ3If4nHt-xHfADWVrfZD8xEf8dw4Fi7ylN-Ta0vuHbITq0Y1Kf-Cp0PdqeL7u_LfGn0Pmwpz6evrOvDttEt5f3hv359bhbPWfrzdPLarnObAFFn1mwWMi6qHOnihpL3RC6ShbgSJZ5WQuXOywQVd5UmqQUY6zQgXSoagdK3rAf595DDMdhvMzsfbLUtthRGJKBcrFQUEi5GNH5GbUxpBTJmUP0e4wnA8JMjs3k2EyOzeR4XLi_dGOy2LqI3QR8bEmpyxKm3sUZo_HOd0_RJOups9T4OFo3TfCf_fAPQ3OQ2A</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1688514338</pqid></control><display><type>article</type><title>On the Selection of Test Liquids for the Evaluation of Acid-Base Properties of Solid Surfaces by Contact Angle Goniometry</title><source>Access via ScienceDirect (Elsevier)</source><creator>Hollander, A</creator><creatorcontrib>Hollander, A</creatorcontrib><description>The determination of the surface free energy (SFE) components from contact angle data using the acid-base (AB) model is often not consistent when various sets of test liquids are utilized. Using contact angle data from the literature, mathematical instabilities of the model are discussed as one of the origins of these inconsistencies. In order to obtain reliable results, the difference of the ratios of the basic and acidic parts of the interfacial free energy of the test liquids should be large. If this condition is not satisfied, small deviations of the measured contact angles (within the range of experimental errors) can produce major differences in the AB components of the SFE. An optimization of the results of several pairs of test liquids can help to obtain reliable results.</description><identifier>ISSN: 0021-9797</identifier><identifier>EISSN: 1095-7103</identifier><identifier>DOI: 10.1006/jcis.1995.1060</identifier><identifier>CODEN: JCISA5</identifier><language>eng</language><publisher>San Diego, CA: Elsevier Inc</publisher><subject>Chemistry ; Exact sciences and technology ; General and physical chemistry ; Solid-liquid interface ; Surface physical chemistry</subject><ispartof>Journal of colloid and interface science, 1995-02, Vol.169 (2), p.493-496</ispartof><rights>1995 Academic Press</rights><rights>1995 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c414t-c1ca43b4b2f54ba69deaf7341fe3626b0f2fa4aa52d79e330e365af13fa5bf153</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1006/jcis.1995.1060$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=3396618$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Hollander, A</creatorcontrib><title>On the Selection of Test Liquids for the Evaluation of Acid-Base Properties of Solid Surfaces by Contact Angle Goniometry</title><title>Journal of colloid and interface science</title><description>The determination of the surface free energy (SFE) components from contact angle data using the acid-base (AB) model is often not consistent when various sets of test liquids are utilized. Using contact angle data from the literature, mathematical instabilities of the model are discussed as one of the origins of these inconsistencies. In order to obtain reliable results, the difference of the ratios of the basic and acidic parts of the interfacial free energy of the test liquids should be large. If this condition is not satisfied, small deviations of the measured contact angles (within the range of experimental errors) can produce major differences in the AB components of the SFE. An optimization of the results of several pairs of test liquids can help to obtain reliable results.</description><subject>Chemistry</subject><subject>Exact sciences and technology</subject><subject>General and physical chemistry</subject><subject>Solid-liquid interface</subject><subject>Surface physical chemistry</subject><issn>0021-9797</issn><issn>1095-7103</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1995</creationdate><recordtype>article</recordtype><recordid>eNp1kDFv2zAQRokiBeqkWTNzyNBFDk8UJXN0jTQJYMAF7M7EiTo2DGTRJqUA_veVamfMRNyHdx9xj7E7EHMQonx4sz7NQWs1jqX4wmYgtMoqEPKKzYTIIdOVrr6x65TehABQSs_YadPx_pX4llqyvQ8dD47vKPV87Y-DbxJ3If4nHt-xHfADWVrfZD8xEf8dw4Fi7ylN-Ta0vuHbITq0Y1Kf-Cp0PdqeL7u_LfGn0Pmwpz6evrOvDttEt5f3hv359bhbPWfrzdPLarnObAFFn1mwWMi6qHOnihpL3RC6ShbgSJZ5WQuXOywQVd5UmqQUY6zQgXSoagdK3rAf595DDMdhvMzsfbLUtthRGJKBcrFQUEi5GNH5GbUxpBTJmUP0e4wnA8JMjs3k2EyOzeR4XLi_dGOy2LqI3QR8bEmpyxKm3sUZo_HOd0_RJOups9T4OFo3TfCf_fAPQ3OQ2A</recordid><startdate>19950201</startdate><enddate>19950201</enddate><creator>Hollander, A</creator><general>Elsevier Inc</general><general>Elsevier</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SE</scope><scope>8FD</scope><scope>JG9</scope></search><sort><creationdate>19950201</creationdate><title>On the Selection of Test Liquids for the Evaluation of Acid-Base Properties of Solid Surfaces by Contact Angle Goniometry</title><author>Hollander, A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c414t-c1ca43b4b2f54ba69deaf7341fe3626b0f2fa4aa52d79e330e365af13fa5bf153</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1995</creationdate><topic>Chemistry</topic><topic>Exact sciences and technology</topic><topic>General and physical chemistry</topic><topic>Solid-liquid interface</topic><topic>Surface physical chemistry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hollander, A</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Corrosion Abstracts</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><jtitle>Journal of colloid and interface science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hollander, A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>On the Selection of Test Liquids for the Evaluation of Acid-Base Properties of Solid Surfaces by Contact Angle Goniometry</atitle><jtitle>Journal of colloid and interface science</jtitle><date>1995-02-01</date><risdate>1995</risdate><volume>169</volume><issue>2</issue><spage>493</spage><epage>496</epage><pages>493-496</pages><issn>0021-9797</issn><eissn>1095-7103</eissn><coden>JCISA5</coden><abstract>The determination of the surface free energy (SFE) components from contact angle data using the acid-base (AB) model is often not consistent when various sets of test liquids are utilized. Using contact angle data from the literature, mathematical instabilities of the model are discussed as one of the origins of these inconsistencies. In order to obtain reliable results, the difference of the ratios of the basic and acidic parts of the interfacial free energy of the test liquids should be large. If this condition is not satisfied, small deviations of the measured contact angles (within the range of experimental errors) can produce major differences in the AB components of the SFE. An optimization of the results of several pairs of test liquids can help to obtain reliable results.</abstract><cop>San Diego, CA</cop><pub>Elsevier Inc</pub><doi>10.1006/jcis.1995.1060</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0021-9797 |
ispartof | Journal of colloid and interface science, 1995-02, Vol.169 (2), p.493-496 |
issn | 0021-9797 1095-7103 |
language | eng |
recordid | cdi_proquest_miscellaneous_1688514338 |
source | Access via ScienceDirect (Elsevier) |
subjects | Chemistry Exact sciences and technology General and physical chemistry Solid-liquid interface Surface physical chemistry |
title | On the Selection of Test Liquids for the Evaluation of Acid-Base Properties of Solid Surfaces by Contact Angle Goniometry |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T16%3A10%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=On%20the%20Selection%20of%20Test%20Liquids%20for%20the%20Evaluation%20of%20Acid-Base%20Properties%20of%20Solid%20Surfaces%20by%20Contact%20Angle%20Goniometry&rft.jtitle=Journal%20of%20colloid%20and%20interface%20science&rft.au=Hollander,%20A&rft.date=1995-02-01&rft.volume=169&rft.issue=2&rft.spage=493&rft.epage=496&rft.pages=493-496&rft.issn=0021-9797&rft.eissn=1095-7103&rft.coden=JCISA5&rft_id=info:doi/10.1006/jcis.1995.1060&rft_dat=%3Cproquest_cross%3E1688514338%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1688514338&rft_id=info:pmid/&rft_els_id=S0021979785710600&rfr_iscdi=true |