Offshore Wind Integration to a Weak Grid by VSC-HVDC Links Using Power-Synchronization Control: A Case Study

In this paper, the application of a recently invented power-synchronization control is proposed for integrating a doubly fed induction generator (DFIG)-based offshore wind farm to a weak ac grid through a voltage-source converter (VSC)-based high-voltage dc link. The control strategy, along with the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on power delivery 2014-02, Vol.29 (1), p.453-461
Hauptverfasser: Mitra, Pinaki, Lidong Zhang, Harnefors, Lennart
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 461
container_issue 1
container_start_page 453
container_title IEEE transactions on power delivery
container_volume 29
creator Mitra, Pinaki
Lidong Zhang
Harnefors, Lennart
description In this paper, the application of a recently invented power-synchronization control is proposed for integrating a doubly fed induction generator (DFIG)-based offshore wind farm to a weak ac grid through a voltage-source converter (VSC)-based high-voltage dc link. The control strategy, along with the antiwindup techniques and the bumpless transfer between two different control modes, is elaborately discussed. Two different fault cases, namely, onshore and offshore faults are considered and the fault-ride through techniques are presented. In case of the onshore fault, both with-chopper and without-chopper solutions are investigated. For an offshore fault, a coordinated fault-ridethrough scheme is proposed when the offshore HVDC converter and the wind farm are in voltage-control modes. The entire study is carried out in a real-time digital simulator (RTDS) platform.
doi_str_mv 10.1109/TPWRD.2013.2273979
format Article
fullrecord <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_proquest_miscellaneous_1685776984</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6575185</ieee_id><sourcerecordid>1685776984</sourcerecordid><originalsourceid>FETCH-LOGICAL-c394t-3c3c0b3212cb1b6731e255a3a216ff6d349c5d14d8d4b14777c2978f9bd93d3b3</originalsourceid><addsrcrecordid>eNpdkUtLJDEURsOgMO3jDzibgBs31ZObpCrJ7KQcH9Cg2GovQypJabRMNKlmaH-9rS2zcHU353xcOAgdAJkCEPX75mpxfTKlBNiUUsGUUD_QBBQTFadEbqEJkbKupBLiJ9op5ZEQwokiEzRc9n15SNnjRYgOX8TR32czhhTxmLDBC2-e8FkODncrfDdvq_O7kxbPQnwq-LaEeI-v0j-fq_kq2oecYnjbyG2KY07DH3yMW1M8no9Lt9pD270Zit__urvo9vTvTXtezS7PLtrjWWWZ4mPFLLOkYxSo7aBrBANP69owQ6Hp-8YxrmztgDvpeAdcCGGpErJXnVPMsY7toqPN7ktOr0tfRv0civXDYKJPy6KhkbUQjZJ8jR5-Qx_TMsf1dxq4Ag6CMbmm6IayOZWSfa9fcng2eaWB6I8A-jOA_gigvwKspV8bKXjv_wtNLWqQNXsHJwmASg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1491417338</pqid></control><display><type>article</type><title>Offshore Wind Integration to a Weak Grid by VSC-HVDC Links Using Power-Synchronization Control: A Case Study</title><source>IEEE Electronic Library (IEL)</source><creator>Mitra, Pinaki ; Lidong Zhang ; Harnefors, Lennart</creator><creatorcontrib>Mitra, Pinaki ; Lidong Zhang ; Harnefors, Lennart</creatorcontrib><description>In this paper, the application of a recently invented power-synchronization control is proposed for integrating a doubly fed induction generator (DFIG)-based offshore wind farm to a weak ac grid through a voltage-source converter (VSC)-based high-voltage dc link. The control strategy, along with the antiwindup techniques and the bumpless transfer between two different control modes, is elaborately discussed. Two different fault cases, namely, onshore and offshore faults are considered and the fault-ride through techniques are presented. In case of the onshore fault, both with-chopper and without-chopper solutions are investigated. For an offshore fault, a coordinated fault-ridethrough scheme is proposed when the offshore HVDC converter and the wind farm are in voltage-control modes. The entire study is carried out in a real-time digital simulator (RTDS) platform.</description><identifier>ISSN: 0885-8977</identifier><identifier>EISSN: 1937-4208</identifier><identifier>DOI: 10.1109/TPWRD.2013.2273979</identifier><identifier>CODEN: ITPDE5</identifier><language>eng</language><publisher>New York: IEEE</publisher><subject>Control ; Converters ; Electric converters ; Faults ; HVDC ; HVDC transmission ; Links ; Offshore drilling rigs ; Offshore engineering ; Power conversion ; Strategy ; Synchronization ; Vectors ; Voltage control ; weak grid ; Wind farms ; Wind power</subject><ispartof>IEEE transactions on power delivery, 2014-02, Vol.29 (1), p.453-461</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) Feb 2014</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c394t-3c3c0b3212cb1b6731e255a3a216ff6d349c5d14d8d4b14777c2978f9bd93d3b3</citedby><cites>FETCH-LOGICAL-c394t-3c3c0b3212cb1b6731e255a3a216ff6d349c5d14d8d4b14777c2978f9bd93d3b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6575185$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,796,27924,27925,54758</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6575185$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Mitra, Pinaki</creatorcontrib><creatorcontrib>Lidong Zhang</creatorcontrib><creatorcontrib>Harnefors, Lennart</creatorcontrib><title>Offshore Wind Integration to a Weak Grid by VSC-HVDC Links Using Power-Synchronization Control: A Case Study</title><title>IEEE transactions on power delivery</title><addtitle>TPWRD</addtitle><description>In this paper, the application of a recently invented power-synchronization control is proposed for integrating a doubly fed induction generator (DFIG)-based offshore wind farm to a weak ac grid through a voltage-source converter (VSC)-based high-voltage dc link. The control strategy, along with the antiwindup techniques and the bumpless transfer between two different control modes, is elaborately discussed. Two different fault cases, namely, onshore and offshore faults are considered and the fault-ride through techniques are presented. In case of the onshore fault, both with-chopper and without-chopper solutions are investigated. For an offshore fault, a coordinated fault-ridethrough scheme is proposed when the offshore HVDC converter and the wind farm are in voltage-control modes. The entire study is carried out in a real-time digital simulator (RTDS) platform.</description><subject>Control</subject><subject>Converters</subject><subject>Electric converters</subject><subject>Faults</subject><subject>HVDC</subject><subject>HVDC transmission</subject><subject>Links</subject><subject>Offshore drilling rigs</subject><subject>Offshore engineering</subject><subject>Power conversion</subject><subject>Strategy</subject><subject>Synchronization</subject><subject>Vectors</subject><subject>Voltage control</subject><subject>weak grid</subject><subject>Wind farms</subject><subject>Wind power</subject><issn>0885-8977</issn><issn>1937-4208</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNpdkUtLJDEURsOgMO3jDzibgBs31ZObpCrJ7KQcH9Cg2GovQypJabRMNKlmaH-9rS2zcHU353xcOAgdAJkCEPX75mpxfTKlBNiUUsGUUD_QBBQTFadEbqEJkbKupBLiJ9op5ZEQwokiEzRc9n15SNnjRYgOX8TR32czhhTxmLDBC2-e8FkODncrfDdvq_O7kxbPQnwq-LaEeI-v0j-fq_kq2oecYnjbyG2KY07DH3yMW1M8no9Lt9pD270Zit__urvo9vTvTXtezS7PLtrjWWWZ4mPFLLOkYxSo7aBrBANP69owQ6Hp-8YxrmztgDvpeAdcCGGpErJXnVPMsY7toqPN7ktOr0tfRv0civXDYKJPy6KhkbUQjZJ8jR5-Qx_TMsf1dxq4Ag6CMbmm6IayOZWSfa9fcng2eaWB6I8A-jOA_gigvwKspV8bKXjv_wtNLWqQNXsHJwmASg</recordid><startdate>20140201</startdate><enddate>20140201</enddate><creator>Mitra, Pinaki</creator><creator>Lidong Zhang</creator><creator>Harnefors, Lennart</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope><scope>L7M</scope><scope>7SU</scope><scope>C1K</scope><scope>F28</scope></search><sort><creationdate>20140201</creationdate><title>Offshore Wind Integration to a Weak Grid by VSC-HVDC Links Using Power-Synchronization Control: A Case Study</title><author>Mitra, Pinaki ; Lidong Zhang ; Harnefors, Lennart</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c394t-3c3c0b3212cb1b6731e255a3a216ff6d349c5d14d8d4b14777c2978f9bd93d3b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Control</topic><topic>Converters</topic><topic>Electric converters</topic><topic>Faults</topic><topic>HVDC</topic><topic>HVDC transmission</topic><topic>Links</topic><topic>Offshore drilling rigs</topic><topic>Offshore engineering</topic><topic>Power conversion</topic><topic>Strategy</topic><topic>Synchronization</topic><topic>Vectors</topic><topic>Voltage control</topic><topic>weak grid</topic><topic>Wind farms</topic><topic>Wind power</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mitra, Pinaki</creatorcontrib><creatorcontrib>Lidong Zhang</creatorcontrib><creatorcontrib>Harnefors, Lennart</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Environmental Engineering Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><jtitle>IEEE transactions on power delivery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Mitra, Pinaki</au><au>Lidong Zhang</au><au>Harnefors, Lennart</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Offshore Wind Integration to a Weak Grid by VSC-HVDC Links Using Power-Synchronization Control: A Case Study</atitle><jtitle>IEEE transactions on power delivery</jtitle><stitle>TPWRD</stitle><date>2014-02-01</date><risdate>2014</risdate><volume>29</volume><issue>1</issue><spage>453</spage><epage>461</epage><pages>453-461</pages><issn>0885-8977</issn><eissn>1937-4208</eissn><coden>ITPDE5</coden><abstract>In this paper, the application of a recently invented power-synchronization control is proposed for integrating a doubly fed induction generator (DFIG)-based offshore wind farm to a weak ac grid through a voltage-source converter (VSC)-based high-voltage dc link. The control strategy, along with the antiwindup techniques and the bumpless transfer between two different control modes, is elaborately discussed. Two different fault cases, namely, onshore and offshore faults are considered and the fault-ride through techniques are presented. In case of the onshore fault, both with-chopper and without-chopper solutions are investigated. For an offshore fault, a coordinated fault-ridethrough scheme is proposed when the offshore HVDC converter and the wind farm are in voltage-control modes. The entire study is carried out in a real-time digital simulator (RTDS) platform.</abstract><cop>New York</cop><pub>IEEE</pub><doi>10.1109/TPWRD.2013.2273979</doi><tpages>9</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0885-8977
ispartof IEEE transactions on power delivery, 2014-02, Vol.29 (1), p.453-461
issn 0885-8977
1937-4208
language eng
recordid cdi_proquest_miscellaneous_1685776984
source IEEE Electronic Library (IEL)
subjects Control
Converters
Electric converters
Faults
HVDC
HVDC transmission
Links
Offshore drilling rigs
Offshore engineering
Power conversion
Strategy
Synchronization
Vectors
Voltage control
weak grid
Wind farms
Wind power
title Offshore Wind Integration to a Weak Grid by VSC-HVDC Links Using Power-Synchronization Control: A Case Study
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-23T13%3A51%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Offshore%20Wind%20Integration%20to%20a%20Weak%20Grid%20by%20VSC-HVDC%20Links%20Using%20Power-Synchronization%20Control:%20A%20Case%20Study&rft.jtitle=IEEE%20transactions%20on%20power%20delivery&rft.au=Mitra,%20Pinaki&rft.date=2014-02-01&rft.volume=29&rft.issue=1&rft.spage=453&rft.epage=461&rft.pages=453-461&rft.issn=0885-8977&rft.eissn=1937-4208&rft.coden=ITPDE5&rft_id=info:doi/10.1109/TPWRD.2013.2273979&rft_dat=%3Cproquest_RIE%3E1685776984%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1491417338&rft_id=info:pmid/&rft_ieee_id=6575185&rfr_iscdi=true