CT pulmonary angiogram with 60% dose reduction: Influence of iterative reconstructions on image quality

Abstract Goals To compare the quality of low-dose CT images with sinogram affirmed iterative reconstruction (SAFIRE), and full-dose CT with filtered back projection reconstructions (FBP). Materials and methods Fifty pulmonary CT performed by a dual-source technique (120 kVp; 110 mAs) with (a) the sa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Diagnostic and interventional imaging 2015-05, Vol.96 (5), p.487-493
Hauptverfasser: Pontana, F, Moureau, D, Schmidt, B, Duhamel, A, Faivre, J.-B, Yasunaga, K, Remy, J, Remy-Jardin, M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 493
container_issue 5
container_start_page 487
container_title Diagnostic and interventional imaging
container_volume 96
creator Pontana, F
Moureau, D
Schmidt, B
Duhamel, A
Faivre, J.-B
Yasunaga, K
Remy, J
Remy-Jardin, M
description Abstract Goals To compare the quality of low-dose CT images with sinogram affirmed iterative reconstruction (SAFIRE), and full-dose CT with filtered back projection reconstructions (FBP). Materials and methods Fifty pulmonary CT performed by a dual-source technique (120 kVp; 110 mAs) with (a) the same energy in both tubes, and (b) the distribution of reference mAs with 40% in tube A (44 mAs) and 60% in tube B (66 mAs). Each acquisition allowed reconstruction of: (a) full-dose images (with both tubes) with FBP reconstructions (group 1); and (b) low-dose images (from tube A) reconstructed with SAFIRE (group 2). Results Group 2 images presented: (a) a significant objective reduction in noise measured in the trachea on mediastinal (16.04 ± 5.66 vs 17.66 ± 5.84) ( P = 0.0284) and pulmonary (29.77 ± 6.79 vs 37.96 ± 9.03) ( P < 0.0001) images; (b) a similar subjective perception of noise and overall image quality ( P = 1), which was considered to be excellent in 66% (33/50) of the cases, with no influence on the detection of elementary pulmonary lesions of infiltration (98.4%; 95% CI = [96.9%–99.9%]). Conclusion Despite a 60% reduction in radiation dose, the image quality with iterative reconstruction is objectively better and subjectively similar to full-dose FBP images.
doi_str_mv 10.1016/j.diii.2014.08.006
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1680955073</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S2211568415000297</els_id><sourcerecordid>1680955073</sourcerecordid><originalsourceid>FETCH-LOGICAL-c455t-d9112a9224d3661e686877587a845ad81a8302f2f81f27d8b87f0727dd7e15b33</originalsourceid><addsrcrecordid>eNp9kV9rHCEUxSW0JCHNF-hD8SXQl52qM_7ZUApladJAoA9Nn8XVO1u3M7pRJ2W_fR02DSEP8cWLnHM5_g5C7ylpKKHi07Zx3vuGEdo1RDWEiCN0yhilCy5U9-bZfILOc96SekQ1dt0xOmH1XUjJT9FmdYd30zDGYNIem7DxcZPMiP_68hsLcoFdzIATuMkWH8Mlvgn9MEGwgGOPfYFkin-YFTaGXNJBlnEM2I9mA_h-MoMv-3fobW-GDOeP9xn6dfXtbvV9cfvj-mb19XZhO87Lwi0pZWbJWOdaISjUmKrmVNKojhunqFEtYT3rFe2ZdGqtZE9knZwEytdte4Y-HvbuUryfIBc9-mxhGEyAOGVNhSJLzomcpewgtSnmnKDXu1Qzp72mRM-M9VbPjPXMWBOlK8Bq-vC4f1qP4J4s_4lWweeDAOovHzwkna2feTlfGRXton99_5cXdjv44K0Z_sAe8jZOKVR-murMNNE_55bnkimv_bKlbP8BUA-hYw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1680955073</pqid></control><display><type>article</type><title>CT pulmonary angiogram with 60% dose reduction: Influence of iterative reconstructions on image quality</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Alma/SFX Local Collection</source><creator>Pontana, F ; Moureau, D ; Schmidt, B ; Duhamel, A ; Faivre, J.-B ; Yasunaga, K ; Remy, J ; Remy-Jardin, M</creator><creatorcontrib>Pontana, F ; Moureau, D ; Schmidt, B ; Duhamel, A ; Faivre, J.-B ; Yasunaga, K ; Remy, J ; Remy-Jardin, M</creatorcontrib><description>Abstract Goals To compare the quality of low-dose CT images with sinogram affirmed iterative reconstruction (SAFIRE), and full-dose CT with filtered back projection reconstructions (FBP). Materials and methods Fifty pulmonary CT performed by a dual-source technique (120 kVp; 110 mAs) with (a) the same energy in both tubes, and (b) the distribution of reference mAs with 40% in tube A (44 mAs) and 60% in tube B (66 mAs). Each acquisition allowed reconstruction of: (a) full-dose images (with both tubes) with FBP reconstructions (group 1); and (b) low-dose images (from tube A) reconstructed with SAFIRE (group 2). Results Group 2 images presented: (a) a significant objective reduction in noise measured in the trachea on mediastinal (16.04 ± 5.66 vs 17.66 ± 5.84) ( P = 0.0284) and pulmonary (29.77 ± 6.79 vs 37.96 ± 9.03) ( P &lt; 0.0001) images; (b) a similar subjective perception of noise and overall image quality ( P = 1), which was considered to be excellent in 66% (33/50) of the cases, with no influence on the detection of elementary pulmonary lesions of infiltration (98.4%; 95% CI = [96.9%–99.9%]). Conclusion Despite a 60% reduction in radiation dose, the image quality with iterative reconstruction is objectively better and subjectively similar to full-dose FBP images.</description><identifier>ISSN: 2211-5684</identifier><identifier>EISSN: 2211-5684</identifier><identifier>DOI: 10.1016/j.diii.2014.08.006</identifier><identifier>PMID: 25686775</identifier><language>eng</language><publisher>France: Elsevier Masson SAS</publisher><subject>Adolescent ; Adult ; Aged ; Aged, 80 and over ; Angiography - methods ; Dose reduction ; Female ; Humans ; Image Processing, Computer-Assisted ; Image quality ; Iterative reconstructions ; Male ; Middle Aged ; Pulmonary Artery - diagnostic imaging ; Pulmonary CT ; Radiation Dosage ; Radiology ; Tomography, X-Ray Computed ; Young Adult</subject><ispartof>Diagnostic and interventional imaging, 2015-05, Vol.96 (5), p.487-493</ispartof><rights>Éditions françaises de radiologie</rights><rights>2015 Éditions françaises de radiologie</rights><rights>Copyright © 2015 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c455t-d9112a9224d3661e686877587a845ad81a8302f2f81f27d8b87f0727dd7e15b33</citedby><cites>FETCH-LOGICAL-c455t-d9112a9224d3661e686877587a845ad81a8302f2f81f27d8b87f0727dd7e15b33</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25686775$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Pontana, F</creatorcontrib><creatorcontrib>Moureau, D</creatorcontrib><creatorcontrib>Schmidt, B</creatorcontrib><creatorcontrib>Duhamel, A</creatorcontrib><creatorcontrib>Faivre, J.-B</creatorcontrib><creatorcontrib>Yasunaga, K</creatorcontrib><creatorcontrib>Remy, J</creatorcontrib><creatorcontrib>Remy-Jardin, M</creatorcontrib><title>CT pulmonary angiogram with 60% dose reduction: Influence of iterative reconstructions on image quality</title><title>Diagnostic and interventional imaging</title><addtitle>Diagn Interv Imaging</addtitle><description>Abstract Goals To compare the quality of low-dose CT images with sinogram affirmed iterative reconstruction (SAFIRE), and full-dose CT with filtered back projection reconstructions (FBP). Materials and methods Fifty pulmonary CT performed by a dual-source technique (120 kVp; 110 mAs) with (a) the same energy in both tubes, and (b) the distribution of reference mAs with 40% in tube A (44 mAs) and 60% in tube B (66 mAs). Each acquisition allowed reconstruction of: (a) full-dose images (with both tubes) with FBP reconstructions (group 1); and (b) low-dose images (from tube A) reconstructed with SAFIRE (group 2). Results Group 2 images presented: (a) a significant objective reduction in noise measured in the trachea on mediastinal (16.04 ± 5.66 vs 17.66 ± 5.84) ( P = 0.0284) and pulmonary (29.77 ± 6.79 vs 37.96 ± 9.03) ( P &lt; 0.0001) images; (b) a similar subjective perception of noise and overall image quality ( P = 1), which was considered to be excellent in 66% (33/50) of the cases, with no influence on the detection of elementary pulmonary lesions of infiltration (98.4%; 95% CI = [96.9%–99.9%]). Conclusion Despite a 60% reduction in radiation dose, the image quality with iterative reconstruction is objectively better and subjectively similar to full-dose FBP images.</description><subject>Adolescent</subject><subject>Adult</subject><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>Angiography - methods</subject><subject>Dose reduction</subject><subject>Female</subject><subject>Humans</subject><subject>Image Processing, Computer-Assisted</subject><subject>Image quality</subject><subject>Iterative reconstructions</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Pulmonary Artery - diagnostic imaging</subject><subject>Pulmonary CT</subject><subject>Radiation Dosage</subject><subject>Radiology</subject><subject>Tomography, X-Ray Computed</subject><subject>Young Adult</subject><issn>2211-5684</issn><issn>2211-5684</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kV9rHCEUxSW0JCHNF-hD8SXQl52qM_7ZUApladJAoA9Nn8XVO1u3M7pRJ2W_fR02DSEP8cWLnHM5_g5C7ylpKKHi07Zx3vuGEdo1RDWEiCN0yhilCy5U9-bZfILOc96SekQ1dt0xOmH1XUjJT9FmdYd30zDGYNIem7DxcZPMiP_68hsLcoFdzIATuMkWH8Mlvgn9MEGwgGOPfYFkin-YFTaGXNJBlnEM2I9mA_h-MoMv-3fobW-GDOeP9xn6dfXtbvV9cfvj-mb19XZhO87Lwi0pZWbJWOdaISjUmKrmVNKojhunqFEtYT3rFe2ZdGqtZE9knZwEytdte4Y-HvbuUryfIBc9-mxhGEyAOGVNhSJLzomcpewgtSnmnKDXu1Qzp72mRM-M9VbPjPXMWBOlK8Bq-vC4f1qP4J4s_4lWweeDAOovHzwkna2feTlfGRXton99_5cXdjv44K0Z_sAe8jZOKVR-murMNNE_55bnkimv_bKlbP8BUA-hYw</recordid><startdate>20150501</startdate><enddate>20150501</enddate><creator>Pontana, F</creator><creator>Moureau, D</creator><creator>Schmidt, B</creator><creator>Duhamel, A</creator><creator>Faivre, J.-B</creator><creator>Yasunaga, K</creator><creator>Remy, J</creator><creator>Remy-Jardin, M</creator><general>Elsevier Masson SAS</general><scope>6I.</scope><scope>AAFTH</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20150501</creationdate><title>CT pulmonary angiogram with 60% dose reduction: Influence of iterative reconstructions on image quality</title><author>Pontana, F ; Moureau, D ; Schmidt, B ; Duhamel, A ; Faivre, J.-B ; Yasunaga, K ; Remy, J ; Remy-Jardin, M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c455t-d9112a9224d3661e686877587a845ad81a8302f2f81f27d8b87f0727dd7e15b33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Adolescent</topic><topic>Adult</topic><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>Angiography - methods</topic><topic>Dose reduction</topic><topic>Female</topic><topic>Humans</topic><topic>Image Processing, Computer-Assisted</topic><topic>Image quality</topic><topic>Iterative reconstructions</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Pulmonary Artery - diagnostic imaging</topic><topic>Pulmonary CT</topic><topic>Radiation Dosage</topic><topic>Radiology</topic><topic>Tomography, X-Ray Computed</topic><topic>Young Adult</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Pontana, F</creatorcontrib><creatorcontrib>Moureau, D</creatorcontrib><creatorcontrib>Schmidt, B</creatorcontrib><creatorcontrib>Duhamel, A</creatorcontrib><creatorcontrib>Faivre, J.-B</creatorcontrib><creatorcontrib>Yasunaga, K</creatorcontrib><creatorcontrib>Remy, J</creatorcontrib><creatorcontrib>Remy-Jardin, M</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Diagnostic and interventional imaging</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Pontana, F</au><au>Moureau, D</au><au>Schmidt, B</au><au>Duhamel, A</au><au>Faivre, J.-B</au><au>Yasunaga, K</au><au>Remy, J</au><au>Remy-Jardin, M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>CT pulmonary angiogram with 60% dose reduction: Influence of iterative reconstructions on image quality</atitle><jtitle>Diagnostic and interventional imaging</jtitle><addtitle>Diagn Interv Imaging</addtitle><date>2015-05-01</date><risdate>2015</risdate><volume>96</volume><issue>5</issue><spage>487</spage><epage>493</epage><pages>487-493</pages><issn>2211-5684</issn><eissn>2211-5684</eissn><abstract>Abstract Goals To compare the quality of low-dose CT images with sinogram affirmed iterative reconstruction (SAFIRE), and full-dose CT with filtered back projection reconstructions (FBP). Materials and methods Fifty pulmonary CT performed by a dual-source technique (120 kVp; 110 mAs) with (a) the same energy in both tubes, and (b) the distribution of reference mAs with 40% in tube A (44 mAs) and 60% in tube B (66 mAs). Each acquisition allowed reconstruction of: (a) full-dose images (with both tubes) with FBP reconstructions (group 1); and (b) low-dose images (from tube A) reconstructed with SAFIRE (group 2). Results Group 2 images presented: (a) a significant objective reduction in noise measured in the trachea on mediastinal (16.04 ± 5.66 vs 17.66 ± 5.84) ( P = 0.0284) and pulmonary (29.77 ± 6.79 vs 37.96 ± 9.03) ( P &lt; 0.0001) images; (b) a similar subjective perception of noise and overall image quality ( P = 1), which was considered to be excellent in 66% (33/50) of the cases, with no influence on the detection of elementary pulmonary lesions of infiltration (98.4%; 95% CI = [96.9%–99.9%]). Conclusion Despite a 60% reduction in radiation dose, the image quality with iterative reconstruction is objectively better and subjectively similar to full-dose FBP images.</abstract><cop>France</cop><pub>Elsevier Masson SAS</pub><pmid>25686775</pmid><doi>10.1016/j.diii.2014.08.006</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2211-5684
ispartof Diagnostic and interventional imaging, 2015-05, Vol.96 (5), p.487-493
issn 2211-5684
2211-5684
language eng
recordid cdi_proquest_miscellaneous_1680955073
source MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Alma/SFX Local Collection
subjects Adolescent
Adult
Aged
Aged, 80 and over
Angiography - methods
Dose reduction
Female
Humans
Image Processing, Computer-Assisted
Image quality
Iterative reconstructions
Male
Middle Aged
Pulmonary Artery - diagnostic imaging
Pulmonary CT
Radiation Dosage
Radiology
Tomography, X-Ray Computed
Young Adult
title CT pulmonary angiogram with 60% dose reduction: Influence of iterative reconstructions on image quality
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T02%3A58%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=CT%20pulmonary%20angiogram%20with%2060%25%20dose%20reduction:%20Influence%20of%20iterative%20reconstructions%20on%20image%20quality&rft.jtitle=Diagnostic%20and%20interventional%20imaging&rft.au=Pontana,%20F&rft.date=2015-05-01&rft.volume=96&rft.issue=5&rft.spage=487&rft.epage=493&rft.pages=487-493&rft.issn=2211-5684&rft.eissn=2211-5684&rft_id=info:doi/10.1016/j.diii.2014.08.006&rft_dat=%3Cproquest_cross%3E1680955073%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1680955073&rft_id=info:pmid/25686775&rft_els_id=S2211568415000297&rfr_iscdi=true