Modern Paradigm for Peritoneal Catheter Insertion: Single Port Optical Access Laparoscopic Shunt Insertion
BACKGROUND:Ventriculoperitoneal shunting is one of the most commonly performed neurosurgical procedures. Typically, for insertion of the peritoneal catheter, a mini-laparotomy technique is used. Although generally safe, it can be cosmetically undesirable and time consuming. Complications include mal...
Gespeichert in:
Veröffentlicht in: | Neurosurgery 2015-06, Vol.11 Suppl 1 (2), p.205-212 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 212 |
---|---|
container_issue | 2 |
container_start_page | 205 |
container_title | Neurosurgery |
container_volume | 11 Suppl 1 |
creator | Cherian, Jacob Fridley, Jared S Duckworth, Edward A.M |
description | BACKGROUND:Ventriculoperitoneal shunting is one of the most commonly performed neurosurgical procedures. Typically, for insertion of the peritoneal catheter, a mini-laparotomy technique is used. Although generally safe, it can be cosmetically undesirable and time consuming. Complications include malpositioning, bowel injury, and delayed hernias. Laparoscopic techniques have been advocated to address these issues, but have been slow to gain traction with neurosurgeons.
OBJECTIVE:To describe our experience with single port optical access laparoscopy for placement of ventriculoperitoneal shunts. Our technique simplifies adoption of a laparoscopic technique for neurosurgeons looking to incorporate its benefits.
METHODS:All ventriculoperitoneal shunts placed by the senior author since April 2011 were retrospectively reviewed. Surgical and perioperative complications, length of postoperative stay, and need for revisions were analyzed.
RESULTS:Fifty-six patients were included in the study. There were no cases of peritoneal catheter misplacement. One intraoperative complication occurred early in the series, in which there was an injury to the gallbladder necessitating cholecystectomy. There were 7 cases followed by shunt revision inclusive of the abdomen. In 3 cases, pseudocysts were noted.
CONCLUSION:Single port optical access laparoscopy is a fast and minimally invasive technique that allows direct visualization of the layers of the abdominal wall as they are traversed and visualization of the peritoneal catheter during placement. It uses a small cosmetic incision and obviates the need for postoperative abdominal radiographic studies. The procedure has a modest learning curve, but can be safely used without the assistance of an assist surgeon after the skills are acquired. |
doi_str_mv | 10.1227/NEU.0000000000000678 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1680180583</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1680180583</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3058-9e62c379a2e450e2c99c45010332cde0d536de00a1748264ea12de3c3c27a7dc3</originalsourceid><addsrcrecordid>eNp9kE1Lw0AQhhdRbK3-A5E9ekndr3x5k1K1UG2hFryFdTNtUpNs3N1Q_PeutH7gwbnMHJ53ZngQOqdkSBmLrx7HyyH5XVGcHKA-DZkIBBHkEPUJFUnA0-i5h06s3RBCIxEnx6jHwpiKkEZ9tHnQOZgGz6WRebmu8UobPAdTOt2ArPBIugIcGDxpLBhX6uYaL8pmXQGea-PwrHWl8tyNUmAtnspWGm2VbkuFF0XXuJ_gKTpaycrC2b4P0PJ2_DS6D6azu8noZhooTsIkSCFiisepZCBCAkylqfIDJZwzlQPJQx75RiSNRcIiAZKyHLjiisUyzhUfoMvd3tbotw6sy-rSKqgq2YDubEajhNDEn-IeFTtU-aetgVXWmrKW5j2jJPu0nHnL2V_LPnaxv9C91JB_h760eiDZAVtdeXn2teq2YLLCG3XF_7s_AJDIiUQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1680180583</pqid></control><display><type>article</type><title>Modern Paradigm for Peritoneal Catheter Insertion: Single Port Optical Access Laparoscopic Shunt Insertion</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>Cherian, Jacob ; Fridley, Jared S ; Duckworth, Edward A.M</creator><creatorcontrib>Cherian, Jacob ; Fridley, Jared S ; Duckworth, Edward A.M</creatorcontrib><description>BACKGROUND:Ventriculoperitoneal shunting is one of the most commonly performed neurosurgical procedures. Typically, for insertion of the peritoneal catheter, a mini-laparotomy technique is used. Although generally safe, it can be cosmetically undesirable and time consuming. Complications include malpositioning, bowel injury, and delayed hernias. Laparoscopic techniques have been advocated to address these issues, but have been slow to gain traction with neurosurgeons.
OBJECTIVE:To describe our experience with single port optical access laparoscopy for placement of ventriculoperitoneal shunts. Our technique simplifies adoption of a laparoscopic technique for neurosurgeons looking to incorporate its benefits.
METHODS:All ventriculoperitoneal shunts placed by the senior author since April 2011 were retrospectively reviewed. Surgical and perioperative complications, length of postoperative stay, and need for revisions were analyzed.
RESULTS:Fifty-six patients were included in the study. There were no cases of peritoneal catheter misplacement. One intraoperative complication occurred early in the series, in which there was an injury to the gallbladder necessitating cholecystectomy. There were 7 cases followed by shunt revision inclusive of the abdomen. In 3 cases, pseudocysts were noted.
CONCLUSION:Single port optical access laparoscopy is a fast and minimally invasive technique that allows direct visualization of the layers of the abdominal wall as they are traversed and visualization of the peritoneal catheter during placement. It uses a small cosmetic incision and obviates the need for postoperative abdominal radiographic studies. The procedure has a modest learning curve, but can be safely used without the assistance of an assist surgeon after the skills are acquired.</description><identifier>ISSN: 0148-396X</identifier><identifier>ISSN: 2332-4252</identifier><identifier>EISSN: 1524-4040</identifier><identifier>DOI: 10.1227/NEU.0000000000000678</identifier><identifier>PMID: 25714516</identifier><language>eng</language><publisher>United States: Copyright by the Congress of Neurological Surgeons</publisher><subject>Abdominal Wall - surgery ; Adolescent ; Adult ; Aged ; Female ; Humans ; Intraoperative Complications - epidemiology ; Intraoperative Complications - etiology ; Laparoscopy - adverse effects ; Laparoscopy - methods ; Male ; Peritoneal Cavity - surgery ; Postoperative Period ; Retrospective Studies ; Ventriculoperitoneal Shunt - adverse effects ; Ventriculoperitoneal Shunt - methods</subject><ispartof>Neurosurgery, 2015-06, Vol.11 Suppl 1 (2), p.205-212</ispartof><rights>Copyright © by the Congress of Neurological Surgeons</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c3058-9e62c379a2e450e2c99c45010332cde0d536de00a1748264ea12de3c3c27a7dc3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25714516$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Cherian, Jacob</creatorcontrib><creatorcontrib>Fridley, Jared S</creatorcontrib><creatorcontrib>Duckworth, Edward A.M</creatorcontrib><title>Modern Paradigm for Peritoneal Catheter Insertion: Single Port Optical Access Laparoscopic Shunt Insertion</title><title>Neurosurgery</title><addtitle>Neurosurgery</addtitle><description>BACKGROUND:Ventriculoperitoneal shunting is one of the most commonly performed neurosurgical procedures. Typically, for insertion of the peritoneal catheter, a mini-laparotomy technique is used. Although generally safe, it can be cosmetically undesirable and time consuming. Complications include malpositioning, bowel injury, and delayed hernias. Laparoscopic techniques have been advocated to address these issues, but have been slow to gain traction with neurosurgeons.
OBJECTIVE:To describe our experience with single port optical access laparoscopy for placement of ventriculoperitoneal shunts. Our technique simplifies adoption of a laparoscopic technique for neurosurgeons looking to incorporate its benefits.
METHODS:All ventriculoperitoneal shunts placed by the senior author since April 2011 were retrospectively reviewed. Surgical and perioperative complications, length of postoperative stay, and need for revisions were analyzed.
RESULTS:Fifty-six patients were included in the study. There were no cases of peritoneal catheter misplacement. One intraoperative complication occurred early in the series, in which there was an injury to the gallbladder necessitating cholecystectomy. There were 7 cases followed by shunt revision inclusive of the abdomen. In 3 cases, pseudocysts were noted.
CONCLUSION:Single port optical access laparoscopy is a fast and minimally invasive technique that allows direct visualization of the layers of the abdominal wall as they are traversed and visualization of the peritoneal catheter during placement. It uses a small cosmetic incision and obviates the need for postoperative abdominal radiographic studies. The procedure has a modest learning curve, but can be safely used without the assistance of an assist surgeon after the skills are acquired.</description><subject>Abdominal Wall - surgery</subject><subject>Adolescent</subject><subject>Adult</subject><subject>Aged</subject><subject>Female</subject><subject>Humans</subject><subject>Intraoperative Complications - epidemiology</subject><subject>Intraoperative Complications - etiology</subject><subject>Laparoscopy - adverse effects</subject><subject>Laparoscopy - methods</subject><subject>Male</subject><subject>Peritoneal Cavity - surgery</subject><subject>Postoperative Period</subject><subject>Retrospective Studies</subject><subject>Ventriculoperitoneal Shunt - adverse effects</subject><subject>Ventriculoperitoneal Shunt - methods</subject><issn>0148-396X</issn><issn>2332-4252</issn><issn>1524-4040</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kE1Lw0AQhhdRbK3-A5E9ekndr3x5k1K1UG2hFryFdTNtUpNs3N1Q_PeutH7gwbnMHJ53ZngQOqdkSBmLrx7HyyH5XVGcHKA-DZkIBBHkEPUJFUnA0-i5h06s3RBCIxEnx6jHwpiKkEZ9tHnQOZgGz6WRebmu8UobPAdTOt2ArPBIugIcGDxpLBhX6uYaL8pmXQGea-PwrHWl8tyNUmAtnspWGm2VbkuFF0XXuJ_gKTpaycrC2b4P0PJ2_DS6D6azu8noZhooTsIkSCFiisepZCBCAkylqfIDJZwzlQPJQx75RiSNRcIiAZKyHLjiisUyzhUfoMvd3tbotw6sy-rSKqgq2YDubEajhNDEn-IeFTtU-aetgVXWmrKW5j2jJPu0nHnL2V_LPnaxv9C91JB_h760eiDZAVtdeXn2teq2YLLCG3XF_7s_AJDIiUQ</recordid><startdate>201506</startdate><enddate>201506</enddate><creator>Cherian, Jacob</creator><creator>Fridley, Jared S</creator><creator>Duckworth, Edward A.M</creator><general>Copyright by the Congress of Neurological Surgeons</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201506</creationdate><title>Modern Paradigm for Peritoneal Catheter Insertion: Single Port Optical Access Laparoscopic Shunt Insertion</title><author>Cherian, Jacob ; Fridley, Jared S ; Duckworth, Edward A.M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3058-9e62c379a2e450e2c99c45010332cde0d536de00a1748264ea12de3c3c27a7dc3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Abdominal Wall - surgery</topic><topic>Adolescent</topic><topic>Adult</topic><topic>Aged</topic><topic>Female</topic><topic>Humans</topic><topic>Intraoperative Complications - epidemiology</topic><topic>Intraoperative Complications - etiology</topic><topic>Laparoscopy - adverse effects</topic><topic>Laparoscopy - methods</topic><topic>Male</topic><topic>Peritoneal Cavity - surgery</topic><topic>Postoperative Period</topic><topic>Retrospective Studies</topic><topic>Ventriculoperitoneal Shunt - adverse effects</topic><topic>Ventriculoperitoneal Shunt - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cherian, Jacob</creatorcontrib><creatorcontrib>Fridley, Jared S</creatorcontrib><creatorcontrib>Duckworth, Edward A.M</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Neurosurgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cherian, Jacob</au><au>Fridley, Jared S</au><au>Duckworth, Edward A.M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Modern Paradigm for Peritoneal Catheter Insertion: Single Port Optical Access Laparoscopic Shunt Insertion</atitle><jtitle>Neurosurgery</jtitle><addtitle>Neurosurgery</addtitle><date>2015-06</date><risdate>2015</risdate><volume>11 Suppl 1</volume><issue>2</issue><spage>205</spage><epage>212</epage><pages>205-212</pages><issn>0148-396X</issn><issn>2332-4252</issn><eissn>1524-4040</eissn><abstract>BACKGROUND:Ventriculoperitoneal shunting is one of the most commonly performed neurosurgical procedures. Typically, for insertion of the peritoneal catheter, a mini-laparotomy technique is used. Although generally safe, it can be cosmetically undesirable and time consuming. Complications include malpositioning, bowel injury, and delayed hernias. Laparoscopic techniques have been advocated to address these issues, but have been slow to gain traction with neurosurgeons.
OBJECTIVE:To describe our experience with single port optical access laparoscopy for placement of ventriculoperitoneal shunts. Our technique simplifies adoption of a laparoscopic technique for neurosurgeons looking to incorporate its benefits.
METHODS:All ventriculoperitoneal shunts placed by the senior author since April 2011 were retrospectively reviewed. Surgical and perioperative complications, length of postoperative stay, and need for revisions were analyzed.
RESULTS:Fifty-six patients were included in the study. There were no cases of peritoneal catheter misplacement. One intraoperative complication occurred early in the series, in which there was an injury to the gallbladder necessitating cholecystectomy. There were 7 cases followed by shunt revision inclusive of the abdomen. In 3 cases, pseudocysts were noted.
CONCLUSION:Single port optical access laparoscopy is a fast and minimally invasive technique that allows direct visualization of the layers of the abdominal wall as they are traversed and visualization of the peritoneal catheter during placement. It uses a small cosmetic incision and obviates the need for postoperative abdominal radiographic studies. The procedure has a modest learning curve, but can be safely used without the assistance of an assist surgeon after the skills are acquired.</abstract><cop>United States</cop><pub>Copyright by the Congress of Neurological Surgeons</pub><pmid>25714516</pmid><doi>10.1227/NEU.0000000000000678</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0148-396X |
ispartof | Neurosurgery, 2015-06, Vol.11 Suppl 1 (2), p.205-212 |
issn | 0148-396X 2332-4252 1524-4040 |
language | eng |
recordid | cdi_proquest_miscellaneous_1680180583 |
source | MEDLINE; Journals@Ovid Complete |
subjects | Abdominal Wall - surgery Adolescent Adult Aged Female Humans Intraoperative Complications - epidemiology Intraoperative Complications - etiology Laparoscopy - adverse effects Laparoscopy - methods Male Peritoneal Cavity - surgery Postoperative Period Retrospective Studies Ventriculoperitoneal Shunt - adverse effects Ventriculoperitoneal Shunt - methods |
title | Modern Paradigm for Peritoneal Catheter Insertion: Single Port Optical Access Laparoscopic Shunt Insertion |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T18%3A17%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Modern%20Paradigm%20for%20Peritoneal%20Catheter%20Insertion:%20Single%20Port%20Optical%20Access%20Laparoscopic%20Shunt%20Insertion&rft.jtitle=Neurosurgery&rft.au=Cherian,%20Jacob&rft.date=2015-06&rft.volume=11%20Suppl%201&rft.issue=2&rft.spage=205&rft.epage=212&rft.pages=205-212&rft.issn=0148-396X&rft.eissn=1524-4040&rft_id=info:doi/10.1227/NEU.0000000000000678&rft_dat=%3Cproquest_cross%3E1680180583%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1680180583&rft_id=info:pmid/25714516&rfr_iscdi=true |