Experimental investigation of condensation in micro-fin tubes of different geometries
► Single-phase frictional pressure drop and heat transfer coefficient. ► Condensation characteristics of five single-grooved micro-fin tubes. ► Nonlinear relation between mass flux and heat transfer coefficient. An experimental investigation was performed for single-phase flow and condensation chara...
Gespeichert in:
Veröffentlicht in: | Experimental thermal and fluid science 2012-02, Vol.37, p.19-28 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | ► Single-phase frictional pressure drop and heat transfer coefficient. ► Condensation characteristics of five single-grooved micro-fin tubes. ► Nonlinear relation between mass flux and heat transfer coefficient.
An experimental investigation was performed for single-phase flow and condensation characteristics inside five micro-fin tubes with the same outer diameter 5
mm and helix angle 18°. Data are for mass fluxes ranging from about 200 to 650
kg/m
2
s. The nominal saturation temperature is 320
K, with inlet and outlet qualities of 0.8 and 0.1, respectively. The results suggest that Tube 4 has the highest condensation heat transfer coefficient and also the highest condensation pressure drop penalty, while Tube 5 has the highest enhancement ratio due to its lowest pressure drop penalty and intermediate heat transfer coefficient. Condensation heat transfer coefficient flattens out gradually as
G decreases when
G
<
400
kg/(m
2
s) for Tube 2 and Tube 4. This nonlinear mass-flux effect may be explained by the complex interactions between micro-fins and fluid, including liquid drainage by surface tension and interfacial turbulence. In addition, the experimental data was analyzed using seven existing pressure-drop correlations and four heat-transfer models to verify their respective accuracies. |
---|---|
ISSN: | 0894-1777 1879-2286 |
DOI: | 10.1016/j.expthermflusci.2011.09.008 |