Contained morcellation using the GelPOINT advance access platforms and 3M Steri-Drape endobag

Objective To report a technique that safely allows power and hand morcellation for laparoscopic hysterectomy and myomectomy specimens in a contained fashion in the event of unsuspected uterine sarcoma or leiomyosarcoma. Design Video article introducing a method for enclosed tissue morcellation for l...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Fertility and sterility 2015-05, Vol.103 (5), p.e36-e36
Hauptverfasser: Kujansuu, Stephen, M.D, Salari, Bijan W., B.S, Galloway, Michael, D.O, Findley, Austin, M.D, Yaklic, Jerome L., M.D, Massengill, Jason C., M.D, Lindheim, Steven R., M.D
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page e36
container_issue 5
container_start_page e36
container_title Fertility and sterility
container_volume 103
creator Kujansuu, Stephen, M.D
Salari, Bijan W., B.S
Galloway, Michael, D.O
Findley, Austin, M.D
Yaklic, Jerome L., M.D
Massengill, Jason C., M.D
Lindheim, Steven R., M.D
description Objective To report a technique that safely allows power and hand morcellation for laparoscopic hysterectomy and myomectomy specimens in a contained fashion in the event of unsuspected uterine sarcoma or leiomyosarcoma. Design Video article introducing a method for enclosed tissue morcellation for laparoscopic specimens. Setting Hospital of an academic-based practice. Patient(s) Two patients underwent laparoscopic hysterectomy: a 57-year-old G7 P5025 female for leiomyoma, anemia, and a history of CIN-3; and a 38-year-old G0P0 female with a 10-year history of pelvic pain and severe dysmenorrhea who failed medical therapy. Intervention(s) A technique using the GelPOINT Platform incision extender system and GelSeal Cap (GSP) Advanced Access Platform and a 50 cm × 50 cm 3M Steri-Drape endobag for enclosed intracorporeal and extracorporeal tissue morcellation of laparoscopic specimens. Main Outcome Measure(s) For training purposes, we used a pelvic simulator and cadaver to describe the step-by-step process and troubleshoot issues to optimize intra- and extracorporeal morcellation. This allowed for easier implementation on the live patient. Result(s) Simulation training and the cadaver model provided a learning platform for contained internal power and external hand morcellation, accelerating the learning curve in its application to the live patient. Conclusion(s) The GSP and 3M Steri-Drape endobag is an alternative for laparoscopic power or hand morcellation. Using simulation training helped transition this technique to the live patient, allowing for easy and safe removal of tissue specimens and minimizing the potential for tissue seeding and dissemination.
doi_str_mv 10.1016/j.fertnstert.2015.02.017
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1677887791</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0015028215001399</els_id><sourcerecordid>1677887791</sourcerecordid><originalsourceid>FETCH-LOGICAL-c619t-f267975a932270c314fa6eacd971a43268e30889150e4f930b4670c5de5805743</originalsourceid><addsrcrecordid>eNqNkctu1DAUQC0EokPhF5CXbBL8iO14gwRDWyoVitSyRJbHvikeEnuwk0r9ezxMaSVWbK4XPvd1LkKYkpYSKt9u2wHyHMtcY8sIFS1hLaHqCVpRIWQjpOBP0YrUn4awnh2hF6VsCSGSKvYcHTGhFFNSrdD3dYqzDRE8nlJ2MI52DinipYR4g-cfgM9g_Hp5_uUaW39rowNsnYNS8K6SQ8pTwTZ6zD_jqzpNaD5muwMM0aeNvXmJng12LPDq_j1G305PrtefmovLs_P1-4vGSarnZmBSaSWs5owp4jjtBivBOq8VtR1nsgdO-l5TQaAbNCebTlZOeBA9Earjx-jNoe4up18LlNlMofxZJkJaiqFSqb5XStOK9gfU5VRKhsHscphsvjOUmL1cszWPcs1eriHMVLk19fV9l2UzgX9I_GuzAh8OANRdbwNkU1yA6syHDG42PoX_6fLunyJuDDE4O_6EOyjbtORYXRpqSk0wV_sj729cI6Fca_4bYkakBg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1677887791</pqid></control><display><type>article</type><title>Contained morcellation using the GelPOINT advance access platforms and 3M Steri-Drape endobag</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Alma/SFX Local Collection</source><creator>Kujansuu, Stephen, M.D ; Salari, Bijan W., B.S ; Galloway, Michael, D.O ; Findley, Austin, M.D ; Yaklic, Jerome L., M.D ; Massengill, Jason C., M.D ; Lindheim, Steven R., M.D</creator><creatorcontrib>Kujansuu, Stephen, M.D ; Salari, Bijan W., B.S ; Galloway, Michael, D.O ; Findley, Austin, M.D ; Yaklic, Jerome L., M.D ; Massengill, Jason C., M.D ; Lindheim, Steven R., M.D</creatorcontrib><description>Objective To report a technique that safely allows power and hand morcellation for laparoscopic hysterectomy and myomectomy specimens in a contained fashion in the event of unsuspected uterine sarcoma or leiomyosarcoma. Design Video article introducing a method for enclosed tissue morcellation for laparoscopic specimens. Setting Hospital of an academic-based practice. Patient(s) Two patients underwent laparoscopic hysterectomy: a 57-year-old G7 P5025 female for leiomyoma, anemia, and a history of CIN-3; and a 38-year-old G0P0 female with a 10-year history of pelvic pain and severe dysmenorrhea who failed medical therapy. Intervention(s) A technique using the GelPOINT Platform incision extender system and GelSeal Cap (GSP) Advanced Access Platform and a 50 cm × 50 cm 3M Steri-Drape endobag for enclosed intracorporeal and extracorporeal tissue morcellation of laparoscopic specimens. Main Outcome Measure(s) For training purposes, we used a pelvic simulator and cadaver to describe the step-by-step process and troubleshoot issues to optimize intra- and extracorporeal morcellation. This allowed for easier implementation on the live patient. Result(s) Simulation training and the cadaver model provided a learning platform for contained internal power and external hand morcellation, accelerating the learning curve in its application to the live patient. Conclusion(s) The GSP and 3M Steri-Drape endobag is an alternative for laparoscopic power or hand morcellation. Using simulation training helped transition this technique to the live patient, allowing for easy and safe removal of tissue specimens and minimizing the potential for tissue seeding and dissemination.</description><identifier>ISSN: 0015-0282</identifier><identifier>EISSN: 1556-5653</identifier><identifier>DOI: 10.1016/j.fertnstert.2015.02.017</identifier><identifier>PMID: 25772767</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Adult ; Clinical Competence ; Equipment Design ; extracorporeal morcellation ; Female ; Humans ; hysterectomy ; Hysterectomy - instrumentation ; Hysterectomy - methods ; Internal Medicine ; Intracorporeal morcellation ; laparoscopy ; Laparoscopy - instrumentation ; Laparoscopy - methods ; Learning Curve ; Leiomyosarcoma - pathology ; Leiomyosarcoma - surgery ; Middle Aged ; myomectomy ; Obstetrics and Gynecology ; Sarcoma - pathology ; Sarcoma - surgery ; Uterine Myomectomy - instrumentation ; Uterine Myomectomy - methods ; Uterine Neoplasms - pathology ; Uterine Neoplasms - surgery</subject><ispartof>Fertility and sterility, 2015-05, Vol.103 (5), p.e36-e36</ispartof><rights>American Society for Reproductive Medicine</rights><rights>2015 American Society for Reproductive Medicine</rights><rights>Copyright © 2015 American Society for Reproductive Medicine. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c619t-f267975a932270c314fa6eacd971a43268e30889150e4f930b4670c5de5805743</citedby><cites>FETCH-LOGICAL-c619t-f267975a932270c314fa6eacd971a43268e30889150e4f930b4670c5de5805743</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0015028215001399$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25772767$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kujansuu, Stephen, M.D</creatorcontrib><creatorcontrib>Salari, Bijan W., B.S</creatorcontrib><creatorcontrib>Galloway, Michael, D.O</creatorcontrib><creatorcontrib>Findley, Austin, M.D</creatorcontrib><creatorcontrib>Yaklic, Jerome L., M.D</creatorcontrib><creatorcontrib>Massengill, Jason C., M.D</creatorcontrib><creatorcontrib>Lindheim, Steven R., M.D</creatorcontrib><title>Contained morcellation using the GelPOINT advance access platforms and 3M Steri-Drape endobag</title><title>Fertility and sterility</title><addtitle>Fertil Steril</addtitle><description>Objective To report a technique that safely allows power and hand morcellation for laparoscopic hysterectomy and myomectomy specimens in a contained fashion in the event of unsuspected uterine sarcoma or leiomyosarcoma. Design Video article introducing a method for enclosed tissue morcellation for laparoscopic specimens. Setting Hospital of an academic-based practice. Patient(s) Two patients underwent laparoscopic hysterectomy: a 57-year-old G7 P5025 female for leiomyoma, anemia, and a history of CIN-3; and a 38-year-old G0P0 female with a 10-year history of pelvic pain and severe dysmenorrhea who failed medical therapy. Intervention(s) A technique using the GelPOINT Platform incision extender system and GelSeal Cap (GSP) Advanced Access Platform and a 50 cm × 50 cm 3M Steri-Drape endobag for enclosed intracorporeal and extracorporeal tissue morcellation of laparoscopic specimens. Main Outcome Measure(s) For training purposes, we used a pelvic simulator and cadaver to describe the step-by-step process and troubleshoot issues to optimize intra- and extracorporeal morcellation. This allowed for easier implementation on the live patient. Result(s) Simulation training and the cadaver model provided a learning platform for contained internal power and external hand morcellation, accelerating the learning curve in its application to the live patient. Conclusion(s) The GSP and 3M Steri-Drape endobag is an alternative for laparoscopic power or hand morcellation. Using simulation training helped transition this technique to the live patient, allowing for easy and safe removal of tissue specimens and minimizing the potential for tissue seeding and dissemination.</description><subject>Adult</subject><subject>Clinical Competence</subject><subject>Equipment Design</subject><subject>extracorporeal morcellation</subject><subject>Female</subject><subject>Humans</subject><subject>hysterectomy</subject><subject>Hysterectomy - instrumentation</subject><subject>Hysterectomy - methods</subject><subject>Internal Medicine</subject><subject>Intracorporeal morcellation</subject><subject>laparoscopy</subject><subject>Laparoscopy - instrumentation</subject><subject>Laparoscopy - methods</subject><subject>Learning Curve</subject><subject>Leiomyosarcoma - pathology</subject><subject>Leiomyosarcoma - surgery</subject><subject>Middle Aged</subject><subject>myomectomy</subject><subject>Obstetrics and Gynecology</subject><subject>Sarcoma - pathology</subject><subject>Sarcoma - surgery</subject><subject>Uterine Myomectomy - instrumentation</subject><subject>Uterine Myomectomy - methods</subject><subject>Uterine Neoplasms - pathology</subject><subject>Uterine Neoplasms - surgery</subject><issn>0015-0282</issn><issn>1556-5653</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqNkctu1DAUQC0EokPhF5CXbBL8iO14gwRDWyoVitSyRJbHvikeEnuwk0r9ezxMaSVWbK4XPvd1LkKYkpYSKt9u2wHyHMtcY8sIFS1hLaHqCVpRIWQjpOBP0YrUn4awnh2hF6VsCSGSKvYcHTGhFFNSrdD3dYqzDRE8nlJ2MI52DinipYR4g-cfgM9g_Hp5_uUaW39rowNsnYNS8K6SQ8pTwTZ6zD_jqzpNaD5muwMM0aeNvXmJng12LPDq_j1G305PrtefmovLs_P1-4vGSarnZmBSaSWs5owp4jjtBivBOq8VtR1nsgdO-l5TQaAbNCebTlZOeBA9Earjx-jNoe4up18LlNlMofxZJkJaiqFSqb5XStOK9gfU5VRKhsHscphsvjOUmL1cszWPcs1eriHMVLk19fV9l2UzgX9I_GuzAh8OANRdbwNkU1yA6syHDG42PoX_6fLunyJuDDE4O_6EOyjbtORYXRpqSk0wV_sj729cI6Fca_4bYkakBg</recordid><startdate>20150501</startdate><enddate>20150501</enddate><creator>Kujansuu, Stephen, M.D</creator><creator>Salari, Bijan W., B.S</creator><creator>Galloway, Michael, D.O</creator><creator>Findley, Austin, M.D</creator><creator>Yaklic, Jerome L., M.D</creator><creator>Massengill, Jason C., M.D</creator><creator>Lindheim, Steven R., M.D</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20150501</creationdate><title>Contained morcellation using the GelPOINT advance access platforms and 3M Steri-Drape endobag</title><author>Kujansuu, Stephen, M.D ; Salari, Bijan W., B.S ; Galloway, Michael, D.O ; Findley, Austin, M.D ; Yaklic, Jerome L., M.D ; Massengill, Jason C., M.D ; Lindheim, Steven R., M.D</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c619t-f267975a932270c314fa6eacd971a43268e30889150e4f930b4670c5de5805743</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Adult</topic><topic>Clinical Competence</topic><topic>Equipment Design</topic><topic>extracorporeal morcellation</topic><topic>Female</topic><topic>Humans</topic><topic>hysterectomy</topic><topic>Hysterectomy - instrumentation</topic><topic>Hysterectomy - methods</topic><topic>Internal Medicine</topic><topic>Intracorporeal morcellation</topic><topic>laparoscopy</topic><topic>Laparoscopy - instrumentation</topic><topic>Laparoscopy - methods</topic><topic>Learning Curve</topic><topic>Leiomyosarcoma - pathology</topic><topic>Leiomyosarcoma - surgery</topic><topic>Middle Aged</topic><topic>myomectomy</topic><topic>Obstetrics and Gynecology</topic><topic>Sarcoma - pathology</topic><topic>Sarcoma - surgery</topic><topic>Uterine Myomectomy - instrumentation</topic><topic>Uterine Myomectomy - methods</topic><topic>Uterine Neoplasms - pathology</topic><topic>Uterine Neoplasms - surgery</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kujansuu, Stephen, M.D</creatorcontrib><creatorcontrib>Salari, Bijan W., B.S</creatorcontrib><creatorcontrib>Galloway, Michael, D.O</creatorcontrib><creatorcontrib>Findley, Austin, M.D</creatorcontrib><creatorcontrib>Yaklic, Jerome L., M.D</creatorcontrib><creatorcontrib>Massengill, Jason C., M.D</creatorcontrib><creatorcontrib>Lindheim, Steven R., M.D</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Fertility and sterility</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kujansuu, Stephen, M.D</au><au>Salari, Bijan W., B.S</au><au>Galloway, Michael, D.O</au><au>Findley, Austin, M.D</au><au>Yaklic, Jerome L., M.D</au><au>Massengill, Jason C., M.D</au><au>Lindheim, Steven R., M.D</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Contained morcellation using the GelPOINT advance access platforms and 3M Steri-Drape endobag</atitle><jtitle>Fertility and sterility</jtitle><addtitle>Fertil Steril</addtitle><date>2015-05-01</date><risdate>2015</risdate><volume>103</volume><issue>5</issue><spage>e36</spage><epage>e36</epage><pages>e36-e36</pages><issn>0015-0282</issn><eissn>1556-5653</eissn><abstract>Objective To report a technique that safely allows power and hand morcellation for laparoscopic hysterectomy and myomectomy specimens in a contained fashion in the event of unsuspected uterine sarcoma or leiomyosarcoma. Design Video article introducing a method for enclosed tissue morcellation for laparoscopic specimens. Setting Hospital of an academic-based practice. Patient(s) Two patients underwent laparoscopic hysterectomy: a 57-year-old G7 P5025 female for leiomyoma, anemia, and a history of CIN-3; and a 38-year-old G0P0 female with a 10-year history of pelvic pain and severe dysmenorrhea who failed medical therapy. Intervention(s) A technique using the GelPOINT Platform incision extender system and GelSeal Cap (GSP) Advanced Access Platform and a 50 cm × 50 cm 3M Steri-Drape endobag for enclosed intracorporeal and extracorporeal tissue morcellation of laparoscopic specimens. Main Outcome Measure(s) For training purposes, we used a pelvic simulator and cadaver to describe the step-by-step process and troubleshoot issues to optimize intra- and extracorporeal morcellation. This allowed for easier implementation on the live patient. Result(s) Simulation training and the cadaver model provided a learning platform for contained internal power and external hand morcellation, accelerating the learning curve in its application to the live patient. Conclusion(s) The GSP and 3M Steri-Drape endobag is an alternative for laparoscopic power or hand morcellation. Using simulation training helped transition this technique to the live patient, allowing for easy and safe removal of tissue specimens and minimizing the potential for tissue seeding and dissemination.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>25772767</pmid><doi>10.1016/j.fertnstert.2015.02.017</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0015-0282
ispartof Fertility and sterility, 2015-05, Vol.103 (5), p.e36-e36
issn 0015-0282
1556-5653
language eng
recordid cdi_proquest_miscellaneous_1677887791
source MEDLINE; Elsevier ScienceDirect Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Alma/SFX Local Collection
subjects Adult
Clinical Competence
Equipment Design
extracorporeal morcellation
Female
Humans
hysterectomy
Hysterectomy - instrumentation
Hysterectomy - methods
Internal Medicine
Intracorporeal morcellation
laparoscopy
Laparoscopy - instrumentation
Laparoscopy - methods
Learning Curve
Leiomyosarcoma - pathology
Leiomyosarcoma - surgery
Middle Aged
myomectomy
Obstetrics and Gynecology
Sarcoma - pathology
Sarcoma - surgery
Uterine Myomectomy - instrumentation
Uterine Myomectomy - methods
Uterine Neoplasms - pathology
Uterine Neoplasms - surgery
title Contained morcellation using the GelPOINT advance access platforms and 3M Steri-Drape endobag
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-11T08%3A45%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Contained%20morcellation%20using%20the%20GelPOINT%20advance%20access%20platforms%20and%203M%20Steri-Drape%20endobag&rft.jtitle=Fertility%20and%20sterility&rft.au=Kujansuu,%20Stephen,%20M.D&rft.date=2015-05-01&rft.volume=103&rft.issue=5&rft.spage=e36&rft.epage=e36&rft.pages=e36-e36&rft.issn=0015-0282&rft.eissn=1556-5653&rft_id=info:doi/10.1016/j.fertnstert.2015.02.017&rft_dat=%3Cproquest_cross%3E1677887791%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1677887791&rft_id=info:pmid/25772767&rft_els_id=S0015028215001399&rfr_iscdi=true