Monte Carlo Studies of a Proton Computed Tomography System

Proton therapy is a precise forms of radiation therapy that makes use of high energy proton compared to the conventional, more commonly used and less precise x-ray and electron beams. On the other hand, to fully exploit the proton therapy advantages, very accurate quality controls of the treatments...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on nuclear science 2007-10, Vol.54 (5), p.1487-1491
Hauptverfasser: Cirrone, G.A.P., Cuttone, G., Candiano, G., Di Rosa, F., Lo Nigro, S., Lo Presti, D., Randazzo, N., Sipala, V., Bruzzi, M., Menichelli, D., Scaringella, M., Bashkirov, V., Williams, R.D., Sadrozinski, H.F-W., Heimann, J., Feldt, J., Blumenkrantz, N., Talamonti, C., Schulte, R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1491
container_issue 5
container_start_page 1487
container_title IEEE transactions on nuclear science
container_volume 54
creator Cirrone, G.A.P.
Cuttone, G.
Candiano, G.
Di Rosa, F.
Lo Nigro, S.
Lo Presti, D.
Randazzo, N.
Sipala, V.
Bruzzi, M.
Menichelli, D.
Scaringella, M.
Bashkirov, V.
Williams, R.D.
Sadrozinski, H.F-W.
Heimann, J.
Feldt, J.
Blumenkrantz, N.
Talamonti, C.
Schulte, R.
description Proton therapy is a precise forms of radiation therapy that makes use of high energy proton compared to the conventional, more commonly used and less precise x-ray and electron beams. On the other hand, to fully exploit the proton therapy advantages, very accurate quality controls of the treatments are required. These are mainly related to the dose calculations and treatment planning. Actually dose calculations are routinely performed on the basis of X-ray computed tomography while a big improvement could be obtained with the direct use of protons as the imaging system. In this work we report the results of Monte Carlo simulations for the study of an imaging system based on the use of high energy protons: the proton computed tomography (pCT). The main limitation of the pCT and the current adopted technical solutions, based on the use of the most likely path (MLP) approximation are illustrated. Simulation results are compared with experimental data obtained with a first prototype of pCT system tested with 200 MeV proton beams available at the Loma Linda University Medical Center (LLUMC) (CA).
doi_str_mv 10.1109/TNS.2007.906988
format Article
fullrecord <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_proquest_miscellaneous_1671351433</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4346696</ieee_id><sourcerecordid>1671351433</sourcerecordid><originalsourceid>FETCH-LOGICAL-c449t-6f11fd86dea84f1870cb2dcfe559ea373be148e310cb26e1d20e2db818e266993</originalsourceid><addsrcrecordid>eNqFkU1LxDAQhoMouK6ePXgpHsRLdzNJmibepPgFfsGu59Btp9qlbWrSHvbf21Lx4EFPwwzP-8LwEHIKdAFA9XL9vFowSuOFplIrtUdmEEUqhChW-2RGKahQC60PyZH322EVEY1m5OrJNh0GSeoqG6y6Pi_RB7YI0uDV2c42QWLrtu8wD9a2tu8ubT92wWrnO6yPyUGRVh5PvuecvN3erJP78PHl7iG5fgwzIXQXygKgyJXMMVWiABXTbMPyrMAo0pjymG8QhEIO410i5IwiyzcKFDIpteZzcjH1ts5-9ug7U5c-w6pKG7S9N1xyUFLRf0EGnAGTY-PlnyDIGHgEgvMBPf-Fbm3vmuFfo4GBBM7ZAC0nKHPWe4eFaV1Zp25ngJpRjhnkmFGOmeQMibMpUSLiDy24GD6W_At8LYi-</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>912161332</pqid></control><display><type>article</type><title>Monte Carlo Studies of a Proton Computed Tomography System</title><source>IEEE Electronic Library (IEL)</source><creator>Cirrone, G.A.P. ; Cuttone, G. ; Candiano, G. ; Di Rosa, F. ; Lo Nigro, S. ; Lo Presti, D. ; Randazzo, N. ; Sipala, V. ; Bruzzi, M. ; Menichelli, D. ; Scaringella, M. ; Bashkirov, V. ; Williams, R.D. ; Sadrozinski, H.F-W. ; Heimann, J. ; Feldt, J. ; Blumenkrantz, N. ; Talamonti, C. ; Schulte, R.</creator><creatorcontrib>Cirrone, G.A.P. ; Cuttone, G. ; Candiano, G. ; Di Rosa, F. ; Lo Nigro, S. ; Lo Presti, D. ; Randazzo, N. ; Sipala, V. ; Bruzzi, M. ; Menichelli, D. ; Scaringella, M. ; Bashkirov, V. ; Williams, R.D. ; Sadrozinski, H.F-W. ; Heimann, J. ; Feldt, J. ; Blumenkrantz, N. ; Talamonti, C. ; Schulte, R.</creatorcontrib><description>Proton therapy is a precise forms of radiation therapy that makes use of high energy proton compared to the conventional, more commonly used and less precise x-ray and electron beams. On the other hand, to fully exploit the proton therapy advantages, very accurate quality controls of the treatments are required. These are mainly related to the dose calculations and treatment planning. Actually dose calculations are routinely performed on the basis of X-ray computed tomography while a big improvement could be obtained with the direct use of protons as the imaging system. In this work we report the results of Monte Carlo simulations for the study of an imaging system based on the use of high energy protons: the proton computed tomography (pCT). The main limitation of the pCT and the current adopted technical solutions, based on the use of the most likely path (MLP) approximation are illustrated. Simulation results are compared with experimental data obtained with a first prototype of pCT system tested with 200 MeV proton beams available at the Loma Linda University Medical Center (LLUMC) (CA).</description><identifier>ISSN: 0018-9499</identifier><identifier>EISSN: 1558-1578</identifier><identifier>DOI: 10.1109/TNS.2007.906988</identifier><identifier>CODEN: IETNAE</identifier><language>eng</language><publisher>New York: IEEE</publisher><subject>Biomedical applications of radiation ; Computation ; Computational modeling ; Computed tomography ; Computer simulation ; Electron beams ; Energy use ; GEANT4 ; Imaging ; Mathematical analysis ; Medical imaging ; Medical treatment ; Monte Carlo ; Monte Carlo methods ; Optical imaging ; proton ; Protons ; Quality control ; Studies ; Therapy ; Tomography ; X-ray imaging</subject><ispartof>IEEE transactions on nuclear science, 2007-10, Vol.54 (5), p.1487-1491</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2007</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c449t-6f11fd86dea84f1870cb2dcfe559ea373be148e310cb26e1d20e2db818e266993</citedby><cites>FETCH-LOGICAL-c449t-6f11fd86dea84f1870cb2dcfe559ea373be148e310cb26e1d20e2db818e266993</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4346696$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,776,780,792,27901,27902,54733</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4346696$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Cirrone, G.A.P.</creatorcontrib><creatorcontrib>Cuttone, G.</creatorcontrib><creatorcontrib>Candiano, G.</creatorcontrib><creatorcontrib>Di Rosa, F.</creatorcontrib><creatorcontrib>Lo Nigro, S.</creatorcontrib><creatorcontrib>Lo Presti, D.</creatorcontrib><creatorcontrib>Randazzo, N.</creatorcontrib><creatorcontrib>Sipala, V.</creatorcontrib><creatorcontrib>Bruzzi, M.</creatorcontrib><creatorcontrib>Menichelli, D.</creatorcontrib><creatorcontrib>Scaringella, M.</creatorcontrib><creatorcontrib>Bashkirov, V.</creatorcontrib><creatorcontrib>Williams, R.D.</creatorcontrib><creatorcontrib>Sadrozinski, H.F-W.</creatorcontrib><creatorcontrib>Heimann, J.</creatorcontrib><creatorcontrib>Feldt, J.</creatorcontrib><creatorcontrib>Blumenkrantz, N.</creatorcontrib><creatorcontrib>Talamonti, C.</creatorcontrib><creatorcontrib>Schulte, R.</creatorcontrib><title>Monte Carlo Studies of a Proton Computed Tomography System</title><title>IEEE transactions on nuclear science</title><addtitle>TNS</addtitle><description>Proton therapy is a precise forms of radiation therapy that makes use of high energy proton compared to the conventional, more commonly used and less precise x-ray and electron beams. On the other hand, to fully exploit the proton therapy advantages, very accurate quality controls of the treatments are required. These are mainly related to the dose calculations and treatment planning. Actually dose calculations are routinely performed on the basis of X-ray computed tomography while a big improvement could be obtained with the direct use of protons as the imaging system. In this work we report the results of Monte Carlo simulations for the study of an imaging system based on the use of high energy protons: the proton computed tomography (pCT). The main limitation of the pCT and the current adopted technical solutions, based on the use of the most likely path (MLP) approximation are illustrated. Simulation results are compared with experimental data obtained with a first prototype of pCT system tested with 200 MeV proton beams available at the Loma Linda University Medical Center (LLUMC) (CA).</description><subject>Biomedical applications of radiation</subject><subject>Computation</subject><subject>Computational modeling</subject><subject>Computed tomography</subject><subject>Computer simulation</subject><subject>Electron beams</subject><subject>Energy use</subject><subject>GEANT4</subject><subject>Imaging</subject><subject>Mathematical analysis</subject><subject>Medical imaging</subject><subject>Medical treatment</subject><subject>Monte Carlo</subject><subject>Monte Carlo methods</subject><subject>Optical imaging</subject><subject>proton</subject><subject>Protons</subject><subject>Quality control</subject><subject>Studies</subject><subject>Therapy</subject><subject>Tomography</subject><subject>X-ray imaging</subject><issn>0018-9499</issn><issn>1558-1578</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><recordid>eNqFkU1LxDAQhoMouK6ePXgpHsRLdzNJmibepPgFfsGu59Btp9qlbWrSHvbf21Lx4EFPwwzP-8LwEHIKdAFA9XL9vFowSuOFplIrtUdmEEUqhChW-2RGKahQC60PyZH322EVEY1m5OrJNh0GSeoqG6y6Pi_RB7YI0uDV2c42QWLrtu8wD9a2tu8ubT92wWrnO6yPyUGRVh5PvuecvN3erJP78PHl7iG5fgwzIXQXygKgyJXMMVWiABXTbMPyrMAo0pjymG8QhEIO410i5IwiyzcKFDIpteZzcjH1ts5-9ug7U5c-w6pKG7S9N1xyUFLRf0EGnAGTY-PlnyDIGHgEgvMBPf-Fbm3vmuFfo4GBBM7ZAC0nKHPWe4eFaV1Zp25ngJpRjhnkmFGOmeQMibMpUSLiDy24GD6W_At8LYi-</recordid><startdate>20071001</startdate><enddate>20071001</enddate><creator>Cirrone, G.A.P.</creator><creator>Cuttone, G.</creator><creator>Candiano, G.</creator><creator>Di Rosa, F.</creator><creator>Lo Nigro, S.</creator><creator>Lo Presti, D.</creator><creator>Randazzo, N.</creator><creator>Sipala, V.</creator><creator>Bruzzi, M.</creator><creator>Menichelli, D.</creator><creator>Scaringella, M.</creator><creator>Bashkirov, V.</creator><creator>Williams, R.D.</creator><creator>Sadrozinski, H.F-W.</creator><creator>Heimann, J.</creator><creator>Feldt, J.</creator><creator>Blumenkrantz, N.</creator><creator>Talamonti, C.</creator><creator>Schulte, R.</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QL</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7T7</scope><scope>7TA</scope><scope>7TB</scope><scope>7U5</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>M7N</scope><scope>P64</scope><scope>7QO</scope></search><sort><creationdate>20071001</creationdate><title>Monte Carlo Studies of a Proton Computed Tomography System</title><author>Cirrone, G.A.P. ; Cuttone, G. ; Candiano, G. ; Di Rosa, F. ; Lo Nigro, S. ; Lo Presti, D. ; Randazzo, N. ; Sipala, V. ; Bruzzi, M. ; Menichelli, D. ; Scaringella, M. ; Bashkirov, V. ; Williams, R.D. ; Sadrozinski, H.F-W. ; Heimann, J. ; Feldt, J. ; Blumenkrantz, N. ; Talamonti, C. ; Schulte, R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c449t-6f11fd86dea84f1870cb2dcfe559ea373be148e310cb26e1d20e2db818e266993</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Biomedical applications of radiation</topic><topic>Computation</topic><topic>Computational modeling</topic><topic>Computed tomography</topic><topic>Computer simulation</topic><topic>Electron beams</topic><topic>Energy use</topic><topic>GEANT4</topic><topic>Imaging</topic><topic>Mathematical analysis</topic><topic>Medical imaging</topic><topic>Medical treatment</topic><topic>Monte Carlo</topic><topic>Monte Carlo methods</topic><topic>Optical imaging</topic><topic>proton</topic><topic>Protons</topic><topic>Quality control</topic><topic>Studies</topic><topic>Therapy</topic><topic>Tomography</topic><topic>X-ray imaging</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cirrone, G.A.P.</creatorcontrib><creatorcontrib>Cuttone, G.</creatorcontrib><creatorcontrib>Candiano, G.</creatorcontrib><creatorcontrib>Di Rosa, F.</creatorcontrib><creatorcontrib>Lo Nigro, S.</creatorcontrib><creatorcontrib>Lo Presti, D.</creatorcontrib><creatorcontrib>Randazzo, N.</creatorcontrib><creatorcontrib>Sipala, V.</creatorcontrib><creatorcontrib>Bruzzi, M.</creatorcontrib><creatorcontrib>Menichelli, D.</creatorcontrib><creatorcontrib>Scaringella, M.</creatorcontrib><creatorcontrib>Bashkirov, V.</creatorcontrib><creatorcontrib>Williams, R.D.</creatorcontrib><creatorcontrib>Sadrozinski, H.F-W.</creatorcontrib><creatorcontrib>Heimann, J.</creatorcontrib><creatorcontrib>Feldt, J.</creatorcontrib><creatorcontrib>Blumenkrantz, N.</creatorcontrib><creatorcontrib>Talamonti, C.</creatorcontrib><creatorcontrib>Schulte, R.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Bacteriology Abstracts (Microbiology B)</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Materials Business File</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Algology Mycology and Protozoology Abstracts (Microbiology C)</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Biotechnology Research Abstracts</collection><jtitle>IEEE transactions on nuclear science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Cirrone, G.A.P.</au><au>Cuttone, G.</au><au>Candiano, G.</au><au>Di Rosa, F.</au><au>Lo Nigro, S.</au><au>Lo Presti, D.</au><au>Randazzo, N.</au><au>Sipala, V.</au><au>Bruzzi, M.</au><au>Menichelli, D.</au><au>Scaringella, M.</au><au>Bashkirov, V.</au><au>Williams, R.D.</au><au>Sadrozinski, H.F-W.</au><au>Heimann, J.</au><au>Feldt, J.</au><au>Blumenkrantz, N.</au><au>Talamonti, C.</au><au>Schulte, R.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Monte Carlo Studies of a Proton Computed Tomography System</atitle><jtitle>IEEE transactions on nuclear science</jtitle><stitle>TNS</stitle><date>2007-10-01</date><risdate>2007</risdate><volume>54</volume><issue>5</issue><spage>1487</spage><epage>1491</epage><pages>1487-1491</pages><issn>0018-9499</issn><eissn>1558-1578</eissn><coden>IETNAE</coden><abstract>Proton therapy is a precise forms of radiation therapy that makes use of high energy proton compared to the conventional, more commonly used and less precise x-ray and electron beams. On the other hand, to fully exploit the proton therapy advantages, very accurate quality controls of the treatments are required. These are mainly related to the dose calculations and treatment planning. Actually dose calculations are routinely performed on the basis of X-ray computed tomography while a big improvement could be obtained with the direct use of protons as the imaging system. In this work we report the results of Monte Carlo simulations for the study of an imaging system based on the use of high energy protons: the proton computed tomography (pCT). The main limitation of the pCT and the current adopted technical solutions, based on the use of the most likely path (MLP) approximation are illustrated. Simulation results are compared with experimental data obtained with a first prototype of pCT system tested with 200 MeV proton beams available at the Loma Linda University Medical Center (LLUMC) (CA).</abstract><cop>New York</cop><pub>IEEE</pub><doi>10.1109/TNS.2007.906988</doi><tpages>5</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0018-9499
ispartof IEEE transactions on nuclear science, 2007-10, Vol.54 (5), p.1487-1491
issn 0018-9499
1558-1578
language eng
recordid cdi_proquest_miscellaneous_1671351433
source IEEE Electronic Library (IEL)
subjects Biomedical applications of radiation
Computation
Computational modeling
Computed tomography
Computer simulation
Electron beams
Energy use
GEANT4
Imaging
Mathematical analysis
Medical imaging
Medical treatment
Monte Carlo
Monte Carlo methods
Optical imaging
proton
Protons
Quality control
Studies
Therapy
Tomography
X-ray imaging
title Monte Carlo Studies of a Proton Computed Tomography System
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-05T10%3A10%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Monte%20Carlo%20Studies%20of%20a%20Proton%20Computed%20Tomography%20System&rft.jtitle=IEEE%20transactions%20on%20nuclear%20science&rft.au=Cirrone,%20G.A.P.&rft.date=2007-10-01&rft.volume=54&rft.issue=5&rft.spage=1487&rft.epage=1491&rft.pages=1487-1491&rft.issn=0018-9499&rft.eissn=1558-1578&rft.coden=IETNAE&rft_id=info:doi/10.1109/TNS.2007.906988&rft_dat=%3Cproquest_RIE%3E1671351433%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=912161332&rft_id=info:pmid/&rft_ieee_id=4346696&rfr_iscdi=true