Reliability and concurrent validity of a Smartphone, bubble inclinometer and motion analysis system for measurement of hip joint range of motion

Abstract Objectives Traditional methods of assessing joint range of motion (ROM) involve specialized tools that may not be widely available to clinicians. This study assesses the reliability and validity of a custom Smartphone application for assessing hip joint range of motion. Design Intra-tester...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of science and medicine in sport 2015-05, Vol.18 (3), p.262-267
Hauptverfasser: Charlton, Paula C, Mentiplay, Benjamin F, Pua, Yong-Hao, Clark, Ross A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 267
container_issue 3
container_start_page 262
container_title Journal of science and medicine in sport
container_volume 18
creator Charlton, Paula C
Mentiplay, Benjamin F
Pua, Yong-Hao
Clark, Ross A
description Abstract Objectives Traditional methods of assessing joint range of motion (ROM) involve specialized tools that may not be widely available to clinicians. This study assesses the reliability and validity of a custom Smartphone application for assessing hip joint range of motion. Design Intra-tester reliability with concurrent validity. Methods Passive hip joint range of motion was recorded for seven different movements in 20 males on two separate occasions. Data from a Smartphone, bubble inclinometer and a three dimensional motion analysis (3DMA) system were collected simultaneously. Intraclass correlation coefficients (ICCs), coefficients of variation (CV) and standard error of measurement (SEM) were used to assess reliability. To assess validity of the Smartphone application and the bubble inclinometer against the three dimensional motion analysis system, intraclass correlation coefficients and fixed and proportional biases were used. Results The Smartphone demonstrated good to excellent reliability (ICCs > 0.75) for four out of the seven movements, and moderate to good reliability for the remaining three movements (ICC = 0.63–0.68). Additionally, the Smartphone application displayed comparable reliability to the bubble inclinometer. The Smartphone application displayed excellent validity when compared to the three dimensional motion analysis system for all movements (ICCs > 0.88) except one, which displayed moderate to good validity (ICC = 0.71). Conclusions Smartphones are portable and widely available tools that are mostly reliable and valid for assessing passive hip range of motion, with potential for large-scale use when a bubble inclinometer is not available. However, caution must be taken in its implementation as some movement axes demonstrated only moderate reliability.
doi_str_mv 10.1016/j.jsams.2014.04.008
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1671214539</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1440244014000772</els_id><sourcerecordid>3702754431</sourcerecordid><originalsourceid>FETCH-LOGICAL-c578t-a0e0f9538ebf2964681f24d9d446df2e595313b7e2df99b4cc3225ca14ee0f63</originalsourceid><addsrcrecordid>eNqFUt1qFjEQXUSxtfoEggS86YX7md9N9kJBin9QKNjeh2x21mbNJp_JbmHfoo9stl9V6E1hSCaTc06YnKmq1wTvCCbN-3E3ZjPlHcWE73AJrJ5Ux0RJVRPVkKcl5xzXtCxH1YucR4ypkEw-r44oV4xIIY-r2x_gnemcd_OKTOiRjcEuKUGY0Y3xrt_qcUAGXU4mzfvrGOAd6pau84BcsN6FOMEM6Y48xdnFUFLj1-wyymueYUJDTGgCk5cE0yZc9K7dHo3RlUMy4SdspQP5ZfVsMD7Dq_v9pLr68vnq7Ft9fvH1-9mn89oKqebaYMBDK5iCbqBtwxtFBsr7tue86QcKotwR1kmg_dC2HbeWUSqsIRwKsWEn1elBdp_i7wXyrCeXLXhvAsQla9JIQgkXrC3Qtw-gY1xSaXFDKUEEpZgVFDugbIo5Jxj0PrnyZasmWG9-6VHf-aU3vzQugVVhvbnXXroJ-n-cvwYVwIcDAMpf3DhIOlsHwULvEthZ99E98sDHB_zNMmeN_wUr5P-d6Ew11pfbyGwTQzjGWErK_gBqyL65</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1685152203</pqid></control><display><type>article</type><title>Reliability and concurrent validity of a Smartphone, bubble inclinometer and motion analysis system for measurement of hip joint range of motion</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Charlton, Paula C ; Mentiplay, Benjamin F ; Pua, Yong-Hao ; Clark, Ross A</creator><creatorcontrib>Charlton, Paula C ; Mentiplay, Benjamin F ; Pua, Yong-Hao ; Clark, Ross A</creatorcontrib><description>Abstract Objectives Traditional methods of assessing joint range of motion (ROM) involve specialized tools that may not be widely available to clinicians. This study assesses the reliability and validity of a custom Smartphone application for assessing hip joint range of motion. Design Intra-tester reliability with concurrent validity. Methods Passive hip joint range of motion was recorded for seven different movements in 20 males on two separate occasions. Data from a Smartphone, bubble inclinometer and a three dimensional motion analysis (3DMA) system were collected simultaneously. Intraclass correlation coefficients (ICCs), coefficients of variation (CV) and standard error of measurement (SEM) were used to assess reliability. To assess validity of the Smartphone application and the bubble inclinometer against the three dimensional motion analysis system, intraclass correlation coefficients and fixed and proportional biases were used. Results The Smartphone demonstrated good to excellent reliability (ICCs &gt; 0.75) for four out of the seven movements, and moderate to good reliability for the remaining three movements (ICC = 0.63–0.68). Additionally, the Smartphone application displayed comparable reliability to the bubble inclinometer. The Smartphone application displayed excellent validity when compared to the three dimensional motion analysis system for all movements (ICCs &gt; 0.88) except one, which displayed moderate to good validity (ICC = 0.71). Conclusions Smartphones are portable and widely available tools that are mostly reliable and valid for assessing passive hip range of motion, with potential for large-scale use when a bubble inclinometer is not available. However, caution must be taken in its implementation as some movement axes demonstrated only moderate reliability.</description><identifier>ISSN: 1440-2440</identifier><identifier>EISSN: 1878-1861</identifier><identifier>DOI: 10.1016/j.jsams.2014.04.008</identifier><identifier>PMID: 24831757</identifier><language>eng</language><publisher>Australia: Elsevier Ltd</publisher><subject>Adult ; Android ; Arthrometry, Articular - instrumentation ; Groin ; Hip joint ; Hip Joint - physiology ; Humans ; Injuries ; Injury screening ; Joint angle ; Laboratories ; Male ; Males ; Mobile Applications ; Phone ; Physical Medicine and Rehabilitation ; Professional soccer ; Range of Motion, Articular ; Reproducibility of Results ; Smartphone ; Smartphones ; Sports Medicine ; Studies ; Young Adult</subject><ispartof>Journal of science and medicine in sport, 2015-05, Vol.18 (3), p.262-267</ispartof><rights>Sports Medicine Australia</rights><rights>2014 Sports Medicine Australia</rights><rights>Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.</rights><rights>Copyright Copyright Agency Limited (Distributor) May 2015</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c578t-a0e0f9538ebf2964681f24d9d446df2e595313b7e2df99b4cc3225ca14ee0f63</citedby><cites>FETCH-LOGICAL-c578t-a0e0f9538ebf2964681f24d9d446df2e595313b7e2df99b4cc3225ca14ee0f63</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S1440244014000772$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27903,27904,65309</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24831757$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Charlton, Paula C</creatorcontrib><creatorcontrib>Mentiplay, Benjamin F</creatorcontrib><creatorcontrib>Pua, Yong-Hao</creatorcontrib><creatorcontrib>Clark, Ross A</creatorcontrib><title>Reliability and concurrent validity of a Smartphone, bubble inclinometer and motion analysis system for measurement of hip joint range of motion</title><title>Journal of science and medicine in sport</title><addtitle>J Sci Med Sport</addtitle><description>Abstract Objectives Traditional methods of assessing joint range of motion (ROM) involve specialized tools that may not be widely available to clinicians. This study assesses the reliability and validity of a custom Smartphone application for assessing hip joint range of motion. Design Intra-tester reliability with concurrent validity. Methods Passive hip joint range of motion was recorded for seven different movements in 20 males on two separate occasions. Data from a Smartphone, bubble inclinometer and a three dimensional motion analysis (3DMA) system were collected simultaneously. Intraclass correlation coefficients (ICCs), coefficients of variation (CV) and standard error of measurement (SEM) were used to assess reliability. To assess validity of the Smartphone application and the bubble inclinometer against the three dimensional motion analysis system, intraclass correlation coefficients and fixed and proportional biases were used. Results The Smartphone demonstrated good to excellent reliability (ICCs &gt; 0.75) for four out of the seven movements, and moderate to good reliability for the remaining three movements (ICC = 0.63–0.68). Additionally, the Smartphone application displayed comparable reliability to the bubble inclinometer. The Smartphone application displayed excellent validity when compared to the three dimensional motion analysis system for all movements (ICCs &gt; 0.88) except one, which displayed moderate to good validity (ICC = 0.71). Conclusions Smartphones are portable and widely available tools that are mostly reliable and valid for assessing passive hip range of motion, with potential for large-scale use when a bubble inclinometer is not available. However, caution must be taken in its implementation as some movement axes demonstrated only moderate reliability.</description><subject>Adult</subject><subject>Android</subject><subject>Arthrometry, Articular - instrumentation</subject><subject>Groin</subject><subject>Hip joint</subject><subject>Hip Joint - physiology</subject><subject>Humans</subject><subject>Injuries</subject><subject>Injury screening</subject><subject>Joint angle</subject><subject>Laboratories</subject><subject>Male</subject><subject>Males</subject><subject>Mobile Applications</subject><subject>Phone</subject><subject>Physical Medicine and Rehabilitation</subject><subject>Professional soccer</subject><subject>Range of Motion, Articular</subject><subject>Reproducibility of Results</subject><subject>Smartphone</subject><subject>Smartphones</subject><subject>Sports Medicine</subject><subject>Studies</subject><subject>Young Adult</subject><issn>1440-2440</issn><issn>1878-1861</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>8G5</sourceid><sourceid>BENPR</sourceid><sourceid>GUQSH</sourceid><sourceid>M2O</sourceid><recordid>eNqFUt1qFjEQXUSxtfoEggS86YX7md9N9kJBin9QKNjeh2x21mbNJp_JbmHfoo9stl9V6E1hSCaTc06YnKmq1wTvCCbN-3E3ZjPlHcWE73AJrJ5Ux0RJVRPVkKcl5xzXtCxH1YucR4ypkEw-r44oV4xIIY-r2x_gnemcd_OKTOiRjcEuKUGY0Y3xrt_qcUAGXU4mzfvrGOAd6pau84BcsN6FOMEM6Y48xdnFUFLj1-wyymueYUJDTGgCk5cE0yZc9K7dHo3RlUMy4SdspQP5ZfVsMD7Dq_v9pLr68vnq7Ft9fvH1-9mn89oKqebaYMBDK5iCbqBtwxtFBsr7tue86QcKotwR1kmg_dC2HbeWUSqsIRwKsWEn1elBdp_i7wXyrCeXLXhvAsQla9JIQgkXrC3Qtw-gY1xSaXFDKUEEpZgVFDugbIo5Jxj0PrnyZasmWG9-6VHf-aU3vzQugVVhvbnXXroJ-n-cvwYVwIcDAMpf3DhIOlsHwULvEthZ99E98sDHB_zNMmeN_wUr5P-d6Ew11pfbyGwTQzjGWErK_gBqyL65</recordid><startdate>20150501</startdate><enddate>20150501</enddate><creator>Charlton, Paula C</creator><creator>Mentiplay, Benjamin F</creator><creator>Pua, Yong-Hao</creator><creator>Clark, Ross A</creator><general>Elsevier Ltd</general><general>Elsevier Limited</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7RV</scope><scope>7TS</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>8G5</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AYAGU</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>GUQSH</scope><scope>K9.</scope><scope>KB0</scope><scope>M0S</scope><scope>M1P</scope><scope>M2O</scope><scope>MBDVC</scope><scope>NAPCQ</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>Q9U</scope><scope>7X8</scope></search><sort><creationdate>20150501</creationdate><title>Reliability and concurrent validity of a Smartphone, bubble inclinometer and motion analysis system for measurement of hip joint range of motion</title><author>Charlton, Paula C ; Mentiplay, Benjamin F ; Pua, Yong-Hao ; Clark, Ross A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c578t-a0e0f9538ebf2964681f24d9d446df2e595313b7e2df99b4cc3225ca14ee0f63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Adult</topic><topic>Android</topic><topic>Arthrometry, Articular - instrumentation</topic><topic>Groin</topic><topic>Hip joint</topic><topic>Hip Joint - physiology</topic><topic>Humans</topic><topic>Injuries</topic><topic>Injury screening</topic><topic>Joint angle</topic><topic>Laboratories</topic><topic>Male</topic><topic>Males</topic><topic>Mobile Applications</topic><topic>Phone</topic><topic>Physical Medicine and Rehabilitation</topic><topic>Professional soccer</topic><topic>Range of Motion, Articular</topic><topic>Reproducibility of Results</topic><topic>Smartphone</topic><topic>Smartphones</topic><topic>Sports Medicine</topic><topic>Studies</topic><topic>Young Adult</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Charlton, Paula C</creatorcontrib><creatorcontrib>Mentiplay, Benjamin F</creatorcontrib><creatorcontrib>Pua, Yong-Hao</creatorcontrib><creatorcontrib>Clark, Ross A</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Nursing &amp; Allied Health Database</collection><collection>Physical Education Index</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Research Library (Alumni Edition)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Australia &amp; New Zealand Database</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>Research Library Prep</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Nursing &amp; Allied Health Database (Alumni Edition)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Research Library</collection><collection>Research Library (Corporate)</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central Basic</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of science and medicine in sport</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Charlton, Paula C</au><au>Mentiplay, Benjamin F</au><au>Pua, Yong-Hao</au><au>Clark, Ross A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Reliability and concurrent validity of a Smartphone, bubble inclinometer and motion analysis system for measurement of hip joint range of motion</atitle><jtitle>Journal of science and medicine in sport</jtitle><addtitle>J Sci Med Sport</addtitle><date>2015-05-01</date><risdate>2015</risdate><volume>18</volume><issue>3</issue><spage>262</spage><epage>267</epage><pages>262-267</pages><issn>1440-2440</issn><eissn>1878-1861</eissn><abstract>Abstract Objectives Traditional methods of assessing joint range of motion (ROM) involve specialized tools that may not be widely available to clinicians. This study assesses the reliability and validity of a custom Smartphone application for assessing hip joint range of motion. Design Intra-tester reliability with concurrent validity. Methods Passive hip joint range of motion was recorded for seven different movements in 20 males on two separate occasions. Data from a Smartphone, bubble inclinometer and a three dimensional motion analysis (3DMA) system were collected simultaneously. Intraclass correlation coefficients (ICCs), coefficients of variation (CV) and standard error of measurement (SEM) were used to assess reliability. To assess validity of the Smartphone application and the bubble inclinometer against the three dimensional motion analysis system, intraclass correlation coefficients and fixed and proportional biases were used. Results The Smartphone demonstrated good to excellent reliability (ICCs &gt; 0.75) for four out of the seven movements, and moderate to good reliability for the remaining three movements (ICC = 0.63–0.68). Additionally, the Smartphone application displayed comparable reliability to the bubble inclinometer. The Smartphone application displayed excellent validity when compared to the three dimensional motion analysis system for all movements (ICCs &gt; 0.88) except one, which displayed moderate to good validity (ICC = 0.71). Conclusions Smartphones are portable and widely available tools that are mostly reliable and valid for assessing passive hip range of motion, with potential for large-scale use when a bubble inclinometer is not available. However, caution must be taken in its implementation as some movement axes demonstrated only moderate reliability.</abstract><cop>Australia</cop><pub>Elsevier Ltd</pub><pmid>24831757</pmid><doi>10.1016/j.jsams.2014.04.008</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1440-2440
ispartof Journal of science and medicine in sport, 2015-05, Vol.18 (3), p.262-267
issn 1440-2440
1878-1861
language eng
recordid cdi_proquest_miscellaneous_1671214539
source MEDLINE; Elsevier ScienceDirect Journals
subjects Adult
Android
Arthrometry, Articular - instrumentation
Groin
Hip joint
Hip Joint - physiology
Humans
Injuries
Injury screening
Joint angle
Laboratories
Male
Males
Mobile Applications
Phone
Physical Medicine and Rehabilitation
Professional soccer
Range of Motion, Articular
Reproducibility of Results
Smartphone
Smartphones
Sports Medicine
Studies
Young Adult
title Reliability and concurrent validity of a Smartphone, bubble inclinometer and motion analysis system for measurement of hip joint range of motion
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T11%3A28%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reliability%20and%20concurrent%20validity%20of%20a%20Smartphone,%20bubble%20inclinometer%20and%20motion%20analysis%20system%20for%20measurement%20of%20hip%20joint%20range%20of%20motion&rft.jtitle=Journal%20of%20science%20and%20medicine%20in%20sport&rft.au=Charlton,%20Paula%20C&rft.date=2015-05-01&rft.volume=18&rft.issue=3&rft.spage=262&rft.epage=267&rft.pages=262-267&rft.issn=1440-2440&rft.eissn=1878-1861&rft_id=info:doi/10.1016/j.jsams.2014.04.008&rft_dat=%3Cproquest_cross%3E3702754431%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1685152203&rft_id=info:pmid/24831757&rft_els_id=S1440244014000772&rfr_iscdi=true