Analysis of accelerated degradation of a HT-PEM fuel cell caused by cell reversal in fuel starvation condition

This paper reports an accelerated degradation test of a high temperature PEM fuel cell under repeated H2 starvation condition. The H2 stoichiometry is cycled between 3.0 and 0.8 every 2 min during the test. The experimental results show that the polarity of the fuel cell is reversed under H2 starvat...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of hydrogen energy 2015-02, Vol.40 (6), p.2833-2839
Hauptverfasser: Zhou, Fan, Andreasen, Søren Juhl, Kær, Søren Knudsen, Yu, Donghong
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2839
container_issue 6
container_start_page 2833
container_title International journal of hydrogen energy
container_volume 40
creator Zhou, Fan
Andreasen, Søren Juhl
Kær, Søren Knudsen
Yu, Donghong
description This paper reports an accelerated degradation test of a high temperature PEM fuel cell under repeated H2 starvation condition. The H2 stoichiometry is cycled between 3.0 and 0.8 every 2 min during the test. The experimental results show that the polarity of the fuel cell is reversed under H2 starvation condition, and the cell performance indicated by cell voltage at H2 stoichiometry of 3.0 declines from 0.59 V to 0.41 V in 19 cycles. Since CO2 is detected in anode exhaust under H2 starvation condition, carbon corrosion is believed to be the reason for the degradation in this test. After the test, there is only a slight decrease in open circuit voltage of the fuel cell which implies the membrane is not affected by the test. The electrochemical impedance spectrum measurement shows that the H2 starvation can cause significant increase in the ohmic resistance and charge transfer resistance. By looking at the scanning electron microscopy image of the cross-section of the degraded MEA and comparing it with that of a pristine MEA, great loss in platinum in the anode catalyst layer and carbon corrosion between the anode catalyst layer and the gas diffusion layer are observed, which contribute to the increase in the charge transfer resistance and ohmic resistance, respectively. X-ray diffraction analysis indicates that there is an increase in the size of the platinum particle size on both anode and cathode. •Degradation test of HT-PEM fuel cell were conducted under H2 starvation condition.•Cell reversal and very high decay rate in the performance were observed in this test.•CO2 was detected in the anode exhaust under H2 starvation condition, confirming carbon corrosion.•The membrane was not affected by this test as the OCV remained unchanged before and after the test.•The main cause of the degradation in this test was the loss in platinum in the anode because of carbon corrosion.
doi_str_mv 10.1016/j.ijhydene.2014.12.082
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1669869537</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S036031991403479X</els_id><sourcerecordid>1669869537</sourcerecordid><originalsourceid>FETCH-LOGICAL-c452t-95caf47ba1c51823f809eeff5fa7d6993b652e19b26a8be92b7de992d4409ac53</originalsourceid><addsrcrecordid>eNqFkD1PwzAQhi0EEqXwF1BGlgTbSZx4o6oKRSqCocyWY5_BUeoUO6mUf09CYGa5D91zr-5ehG4JTggm7L5ObP05aHCQUEyyhNAEl_QMLUhZ8DjNyuIcLXDKcJwSzi_RVQg1xqTAGV8gt3KyGYINUWsiqRQ04GUHOtLw4aWWnW3dzyja7uO3zUtkemiiERuD7MMIVsPcejiBD7KJrJuh0El_mgVU67Sdqmt0YWQT4OY3L9H742a_3sa716fn9WoXqyynXcxzJU1WVJKonJQ0NSXmAMbkRhaacZ5WLKdAeEWZLCvgtCo0cE51lmEuVZ4u0d2se_TtVw-hEwcbpjOlg7YPgjDGS8bztBhRNqPKtyF4MOLo7UH6QRAsJoNFLf4MFpPBglAxGjwuPsyLMD5ysuBFUBacAm09qE7o1v4n8Q0erYkK</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1669869537</pqid></control><display><type>article</type><title>Analysis of accelerated degradation of a HT-PEM fuel cell caused by cell reversal in fuel starvation condition</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Zhou, Fan ; Andreasen, Søren Juhl ; Kær, Søren Knudsen ; Yu, Donghong</creator><creatorcontrib>Zhou, Fan ; Andreasen, Søren Juhl ; Kær, Søren Knudsen ; Yu, Donghong</creatorcontrib><description>This paper reports an accelerated degradation test of a high temperature PEM fuel cell under repeated H2 starvation condition. The H2 stoichiometry is cycled between 3.0 and 0.8 every 2 min during the test. The experimental results show that the polarity of the fuel cell is reversed under H2 starvation condition, and the cell performance indicated by cell voltage at H2 stoichiometry of 3.0 declines from 0.59 V to 0.41 V in 19 cycles. Since CO2 is detected in anode exhaust under H2 starvation condition, carbon corrosion is believed to be the reason for the degradation in this test. After the test, there is only a slight decrease in open circuit voltage of the fuel cell which implies the membrane is not affected by the test. The electrochemical impedance spectrum measurement shows that the H2 starvation can cause significant increase in the ohmic resistance and charge transfer resistance. By looking at the scanning electron microscopy image of the cross-section of the degraded MEA and comparing it with that of a pristine MEA, great loss in platinum in the anode catalyst layer and carbon corrosion between the anode catalyst layer and the gas diffusion layer are observed, which contribute to the increase in the charge transfer resistance and ohmic resistance, respectively. X-ray diffraction analysis indicates that there is an increase in the size of the platinum particle size on both anode and cathode. •Degradation test of HT-PEM fuel cell were conducted under H2 starvation condition.•Cell reversal and very high decay rate in the performance were observed in this test.•CO2 was detected in the anode exhaust under H2 starvation condition, confirming carbon corrosion.•The membrane was not affected by this test as the OCV remained unchanged before and after the test.•The main cause of the degradation in this test was the loss in platinum in the anode because of carbon corrosion.</description><identifier>ISSN: 0360-3199</identifier><identifier>EISSN: 1879-3487</identifier><identifier>DOI: 10.1016/j.ijhydene.2014.12.082</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Anodes ; Carbon ; Catalysts ; Cell reversal ; Charge transfer ; Corrosion resistance ; Degradation ; Fuel cells ; H2 starvation ; HT-PEM fuel cell ; Ohmic ; Stoichiometry</subject><ispartof>International journal of hydrogen energy, 2015-02, Vol.40 (6), p.2833-2839</ispartof><rights>2014 Hydrogen Energy Publications, LLC.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c452t-95caf47ba1c51823f809eeff5fa7d6993b652e19b26a8be92b7de992d4409ac53</citedby><cites>FETCH-LOGICAL-c452t-95caf47ba1c51823f809eeff5fa7d6993b652e19b26a8be92b7de992d4409ac53</cites><orcidid>0000-0002-3673-2903</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S036031991403479X$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids></links><search><creatorcontrib>Zhou, Fan</creatorcontrib><creatorcontrib>Andreasen, Søren Juhl</creatorcontrib><creatorcontrib>Kær, Søren Knudsen</creatorcontrib><creatorcontrib>Yu, Donghong</creatorcontrib><title>Analysis of accelerated degradation of a HT-PEM fuel cell caused by cell reversal in fuel starvation condition</title><title>International journal of hydrogen energy</title><description>This paper reports an accelerated degradation test of a high temperature PEM fuel cell under repeated H2 starvation condition. The H2 stoichiometry is cycled between 3.0 and 0.8 every 2 min during the test. The experimental results show that the polarity of the fuel cell is reversed under H2 starvation condition, and the cell performance indicated by cell voltage at H2 stoichiometry of 3.0 declines from 0.59 V to 0.41 V in 19 cycles. Since CO2 is detected in anode exhaust under H2 starvation condition, carbon corrosion is believed to be the reason for the degradation in this test. After the test, there is only a slight decrease in open circuit voltage of the fuel cell which implies the membrane is not affected by the test. The electrochemical impedance spectrum measurement shows that the H2 starvation can cause significant increase in the ohmic resistance and charge transfer resistance. By looking at the scanning electron microscopy image of the cross-section of the degraded MEA and comparing it with that of a pristine MEA, great loss in platinum in the anode catalyst layer and carbon corrosion between the anode catalyst layer and the gas diffusion layer are observed, which contribute to the increase in the charge transfer resistance and ohmic resistance, respectively. X-ray diffraction analysis indicates that there is an increase in the size of the platinum particle size on both anode and cathode. •Degradation test of HT-PEM fuel cell were conducted under H2 starvation condition.•Cell reversal and very high decay rate in the performance were observed in this test.•CO2 was detected in the anode exhaust under H2 starvation condition, confirming carbon corrosion.•The membrane was not affected by this test as the OCV remained unchanged before and after the test.•The main cause of the degradation in this test was the loss in platinum in the anode because of carbon corrosion.</description><subject>Anodes</subject><subject>Carbon</subject><subject>Catalysts</subject><subject>Cell reversal</subject><subject>Charge transfer</subject><subject>Corrosion resistance</subject><subject>Degradation</subject><subject>Fuel cells</subject><subject>H2 starvation</subject><subject>HT-PEM fuel cell</subject><subject>Ohmic</subject><subject>Stoichiometry</subject><issn>0360-3199</issn><issn>1879-3487</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNqFkD1PwzAQhi0EEqXwF1BGlgTbSZx4o6oKRSqCocyWY5_BUeoUO6mUf09CYGa5D91zr-5ehG4JTggm7L5ObP05aHCQUEyyhNAEl_QMLUhZ8DjNyuIcLXDKcJwSzi_RVQg1xqTAGV8gt3KyGYINUWsiqRQ04GUHOtLw4aWWnW3dzyja7uO3zUtkemiiERuD7MMIVsPcejiBD7KJrJuh0El_mgVU67Sdqmt0YWQT4OY3L9H742a_3sa716fn9WoXqyynXcxzJU1WVJKonJQ0NSXmAMbkRhaacZ5WLKdAeEWZLCvgtCo0cE51lmEuVZ4u0d2se_TtVw-hEwcbpjOlg7YPgjDGS8bztBhRNqPKtyF4MOLo7UH6QRAsJoNFLf4MFpPBglAxGjwuPsyLMD5ysuBFUBacAm09qE7o1v4n8Q0erYkK</recordid><startdate>20150219</startdate><enddate>20150219</enddate><creator>Zhou, Fan</creator><creator>Andreasen, Søren Juhl</creator><creator>Kær, Søren Knudsen</creator><creator>Yu, Donghong</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SE</scope><scope>7SP</scope><scope>7SU</scope><scope>7TB</scope><scope>8FD</scope><scope>C1K</scope><scope>FR3</scope><scope>H8D</scope><scope>JG9</scope><scope>KR7</scope><scope>L7M</scope><orcidid>https://orcid.org/0000-0002-3673-2903</orcidid></search><sort><creationdate>20150219</creationdate><title>Analysis of accelerated degradation of a HT-PEM fuel cell caused by cell reversal in fuel starvation condition</title><author>Zhou, Fan ; Andreasen, Søren Juhl ; Kær, Søren Knudsen ; Yu, Donghong</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c452t-95caf47ba1c51823f809eeff5fa7d6993b652e19b26a8be92b7de992d4409ac53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Anodes</topic><topic>Carbon</topic><topic>Catalysts</topic><topic>Cell reversal</topic><topic>Charge transfer</topic><topic>Corrosion resistance</topic><topic>Degradation</topic><topic>Fuel cells</topic><topic>H2 starvation</topic><topic>HT-PEM fuel cell</topic><topic>Ohmic</topic><topic>Stoichiometry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zhou, Fan</creatorcontrib><creatorcontrib>Andreasen, Søren Juhl</creatorcontrib><creatorcontrib>Kær, Søren Knudsen</creatorcontrib><creatorcontrib>Yu, Donghong</creatorcontrib><collection>CrossRef</collection><collection>Corrosion Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Environmental Engineering Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Materials Research Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>International journal of hydrogen energy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zhou, Fan</au><au>Andreasen, Søren Juhl</au><au>Kær, Søren Knudsen</au><au>Yu, Donghong</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Analysis of accelerated degradation of a HT-PEM fuel cell caused by cell reversal in fuel starvation condition</atitle><jtitle>International journal of hydrogen energy</jtitle><date>2015-02-19</date><risdate>2015</risdate><volume>40</volume><issue>6</issue><spage>2833</spage><epage>2839</epage><pages>2833-2839</pages><issn>0360-3199</issn><eissn>1879-3487</eissn><abstract>This paper reports an accelerated degradation test of a high temperature PEM fuel cell under repeated H2 starvation condition. The H2 stoichiometry is cycled between 3.0 and 0.8 every 2 min during the test. The experimental results show that the polarity of the fuel cell is reversed under H2 starvation condition, and the cell performance indicated by cell voltage at H2 stoichiometry of 3.0 declines from 0.59 V to 0.41 V in 19 cycles. Since CO2 is detected in anode exhaust under H2 starvation condition, carbon corrosion is believed to be the reason for the degradation in this test. After the test, there is only a slight decrease in open circuit voltage of the fuel cell which implies the membrane is not affected by the test. The electrochemical impedance spectrum measurement shows that the H2 starvation can cause significant increase in the ohmic resistance and charge transfer resistance. By looking at the scanning electron microscopy image of the cross-section of the degraded MEA and comparing it with that of a pristine MEA, great loss in platinum in the anode catalyst layer and carbon corrosion between the anode catalyst layer and the gas diffusion layer are observed, which contribute to the increase in the charge transfer resistance and ohmic resistance, respectively. X-ray diffraction analysis indicates that there is an increase in the size of the platinum particle size on both anode and cathode. •Degradation test of HT-PEM fuel cell were conducted under H2 starvation condition.•Cell reversal and very high decay rate in the performance were observed in this test.•CO2 was detected in the anode exhaust under H2 starvation condition, confirming carbon corrosion.•The membrane was not affected by this test as the OCV remained unchanged before and after the test.•The main cause of the degradation in this test was the loss in platinum in the anode because of carbon corrosion.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.ijhydene.2014.12.082</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0002-3673-2903</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0360-3199
ispartof International journal of hydrogen energy, 2015-02, Vol.40 (6), p.2833-2839
issn 0360-3199
1879-3487
language eng
recordid cdi_proquest_miscellaneous_1669869537
source Elsevier ScienceDirect Journals Complete
subjects Anodes
Carbon
Catalysts
Cell reversal
Charge transfer
Corrosion resistance
Degradation
Fuel cells
H2 starvation
HT-PEM fuel cell
Ohmic
Stoichiometry
title Analysis of accelerated degradation of a HT-PEM fuel cell caused by cell reversal in fuel starvation condition
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-07T14%3A50%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Analysis%20of%20accelerated%20degradation%20of%20a%20HT-PEM%20fuel%20cell%20caused%20by%20cell%20reversal%20in%20fuel%20starvation%20condition&rft.jtitle=International%20journal%20of%20hydrogen%20energy&rft.au=Zhou,%20Fan&rft.date=2015-02-19&rft.volume=40&rft.issue=6&rft.spage=2833&rft.epage=2839&rft.pages=2833-2839&rft.issn=0360-3199&rft.eissn=1879-3487&rft_id=info:doi/10.1016/j.ijhydene.2014.12.082&rft_dat=%3Cproquest_cross%3E1669869537%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1669869537&rft_id=info:pmid/&rft_els_id=S036031991403479X&rfr_iscdi=true