Safety and Efficacy of Using the Viabahn Endoprosthesis for Percutaneous Treatment of Vascular Access Complications After Transfemoral Aortic Valve Implantation

Vascular access complications (VACs) remain one of the biggest challenges when performing transcatheter aortic valve implantation (TAVI). This study aimed to investigate the short- and medium-term safety and efficacy of the Viabahn endoprosthesis (Gore, Flagstaff, AZ) when used to treat TAVI-induced...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The American journal of cardiology 2015-04, Vol.115 (8), p.1123-1129
Hauptverfasser: De Backer, Ole, MD, PhD, Arnous, Samer, MD, Sandholt, Benjamin, MD, Brooks, Matthew, MD, Biasco, Luigi, MD, Franzen, Olaf, MD, Lönn, Lars, MD, PhD, Bech, Bo, MD, PhD, Søndergaard, Lars, MD, DMSc
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Vascular access complications (VACs) remain one of the biggest challenges when performing transcatheter aortic valve implantation (TAVI). This study aimed to investigate the short- and medium-term safety and efficacy of the Viabahn endoprosthesis (Gore, Flagstaff, AZ) when used to treat TAVI-induced vascular injury. Over a 40-month period, 354 patients underwent true percutaneous transfemoral (TF)-TAVI using a CoreValve and Prostar-XL closure system; this was our study population. A VAC leading to acute intervention occurred in 72 patients (20.3%) - of these, 18 were managed by balloon angioplasty, 48 were treated by Viabahn stenting (technical success rate 98%), and 6 needed surgical intervention. Overall, this approach resulted in a major VAC rate of 3.1% (n = 11) in our study cohort. Length of hospitalization and 30-day mortality rates were comparable in patients with a VAC treated by Viabahn stenting versus patients without vascular complications. Two patients (4.5%) presented with new-onset claudication; one of them had the stent implanted covering the deep femoral artery (DFA). At medium-term follow-up (median 372 days; range 55 to 978 days) duplex ultrasound showed 100% patency of the Viabahn endoprostheses with no signs of stent fracture or in-stent stenosis/occlusion. In conclusion, the use of self-expanding covered stents is safe and effective in case of TF-TAVI–induced vascular injury, with good short- and medium-term outcomes. Importantly, coverage of the DFA should be avoided. If confirmed by long-term (>5 years) follow-up studies, this strategy for treating TAVI-induced VAC may be used routinely in high-risk patients.
ISSN:0002-9149
1879-1913
DOI:10.1016/j.amjcard.2015.01.547