A critical study of different Monte Carlo scoring methods of dose average linear-energy-transfer maps calculated in voxelized geometries irradiated with clinical proton beams

We compare unrestricted dose average linear energy transfer (LET) maps calculated with three different Monte Carlo scoring methods in voxelized geometries irradiated with proton therapy beams with three different Monte Carlo scoring methods. Simulations were done with the Geant4 (Geometry ANd Tracki...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physics in medicine & biology 2015-04, Vol.60 (7), p.2645-2669
Hauptverfasser: Cortés-Giraldo, M A, Carabe, A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2669
container_issue 7
container_start_page 2645
container_title Physics in medicine & biology
container_volume 60
creator Cortés-Giraldo, M A
Carabe, A
description We compare unrestricted dose average linear energy transfer (LET) maps calculated with three different Monte Carlo scoring methods in voxelized geometries irradiated with proton therapy beams with three different Monte Carlo scoring methods. Simulations were done with the Geant4 (Geometry ANd Tracking) toolkit. The first method corresponds to a step-by-step computation of LET which has been reported previously in the literature. We found that this scoring strategy is influenced by spurious high LET components, which relative contribution in the dose average LET calculations significantly increases as the voxel size becomes smaller. Dose average LET values calculated for primary protons in water with voxel size of 0.2 mm were a factor ~1.8 higher than those obtained with a size of 2.0 mm at the plateau region for a 160 MeV beam. Such high LET components are a consequence of proton steps in which the condensed-history algorithm determines an energy transfer to an electron of the material close to the maximum value, while the step length remains limited due to voxel boundary crossing. Two alternative methods were derived to overcome this problem. The second scores LET along the entire path described by each proton within the voxel. The third followed the same approach of the first method, but the LET was evaluated at each step from stopping power tables according to the proton kinetic energy value. We carried out microdosimetry calculations with the aim of deriving reference dose average LET values from microdosimetric quantities. Significant differences between the methods were reported either with pristine or spread-out Bragg peaks (SOBPs). The first method reported values systematically higher than the other two at depths proximal to SOBP by about 15% for a 5.9 cm wide SOBP and about 30% for a 11.0 cm one. At distal SOBP, the second method gave values about 15% lower than the others. Overall, we found that the third method gave the most consistent performance since it returned stable dose average LET values against simulation parameter changes and gave the best agreement with dose average LET estimations from microdosimetry calculations.
doi_str_mv 10.1088/0031-9155/60/7/2645
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1666295863</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1666295863</sourcerecordid><originalsourceid>FETCH-LOGICAL-c345t-3970b55ba7d96eba16c7417de1b959d4fdb06d9eeae97dcbde078cea54a06bfd3</originalsourceid><addsrcrecordid>eNp9kctu1DAUQC0EokPhC5CQl2zS2ElsJ8tqxKNSERtYWzf2zdRVYg-2Uxg-im_EM1O6ZGVZOvdcW4eQt5xdcdb3NWMtrwYuRC1ZrepGduIZ2fBW8koKyZ6TzRNxQV6ldM8Y533TvSQXjVCyZ02_IX-uqYkuOwMzTXm1Bxomat00YUSf6ZfgM9ItxDnQZEJ0fkcXzHfBphMYElJ4wAg7pLPzCLFCj3F3qHIEn4qFLrBPtOjNOkNGS52nD-EXzu53uewwFF10mKiLEaw7IT9dvqOm-E7P2seQg6cjwpJekxcTzAnfPJ6X5PvHD9-2n6vbr59utte3lWk7kat2UGwUYgRlB4kjcGlUx5VFPg5isN1kRybtgAg4KGtGi0z1BkF0wOQ42faSvD97y_IfK6asF5cMzjN4DGvSXErZDKKXbUHbM2piSCnipPfRLRAPmjN9DKWPGfQxg5ZMK30MVabePS5YxwXt08y_MgWoz4ALe30f1ujLf_-r_AsaG6IZ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1666295863</pqid></control><display><type>article</type><title>A critical study of different Monte Carlo scoring methods of dose average linear-energy-transfer maps calculated in voxelized geometries irradiated with clinical proton beams</title><source>MEDLINE</source><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Cortés-Giraldo, M A ; Carabe, A</creator><creatorcontrib>Cortés-Giraldo, M A ; Carabe, A</creatorcontrib><description>We compare unrestricted dose average linear energy transfer (LET) maps calculated with three different Monte Carlo scoring methods in voxelized geometries irradiated with proton therapy beams with three different Monte Carlo scoring methods. Simulations were done with the Geant4 (Geometry ANd Tracking) toolkit. The first method corresponds to a step-by-step computation of LET which has been reported previously in the literature. We found that this scoring strategy is influenced by spurious high LET components, which relative contribution in the dose average LET calculations significantly increases as the voxel size becomes smaller. Dose average LET values calculated for primary protons in water with voxel size of 0.2 mm were a factor ~1.8 higher than those obtained with a size of 2.0 mm at the plateau region for a 160 MeV beam. Such high LET components are a consequence of proton steps in which the condensed-history algorithm determines an energy transfer to an electron of the material close to the maximum value, while the step length remains limited due to voxel boundary crossing. Two alternative methods were derived to overcome this problem. The second scores LET along the entire path described by each proton within the voxel. The third followed the same approach of the first method, but the LET was evaluated at each step from stopping power tables according to the proton kinetic energy value. We carried out microdosimetry calculations with the aim of deriving reference dose average LET values from microdosimetric quantities. Significant differences between the methods were reported either with pristine or spread-out Bragg peaks (SOBPs). The first method reported values systematically higher than the other two at depths proximal to SOBP by about 15% for a 5.9 cm wide SOBP and about 30% for a 11.0 cm one. At distal SOBP, the second method gave values about 15% lower than the others. Overall, we found that the third method gave the most consistent performance since it returned stable dose average LET values against simulation parameter changes and gave the best agreement with dose average LET estimations from microdosimetry calculations.</description><identifier>ISSN: 0031-9155</identifier><identifier>EISSN: 1361-6560</identifier><identifier>DOI: 10.1088/0031-9155/60/7/2645</identifier><identifier>PMID: 25768028</identifier><identifier>CODEN: PHMBA7</identifier><language>eng</language><publisher>England: IOP Publishing</publisher><subject>Algorithms ; Geant4 ; LET ; Linear Energy Transfer ; Monte Carlo Method ; Monte Carlo simulation ; Proton Therapy ; Radiometry - methods</subject><ispartof>Physics in medicine &amp; biology, 2015-04, Vol.60 (7), p.2645-2669</ispartof><rights>2015 Institute of Physics and Engineering in Medicine</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c345t-3970b55ba7d96eba16c7417de1b959d4fdb06d9eeae97dcbde078cea54a06bfd3</citedby><cites>FETCH-LOGICAL-c345t-3970b55ba7d96eba16c7417de1b959d4fdb06d9eeae97dcbde078cea54a06bfd3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/0031-9155/60/7/2645/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,780,784,27923,27924,53845,53892</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25768028$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Cortés-Giraldo, M A</creatorcontrib><creatorcontrib>Carabe, A</creatorcontrib><title>A critical study of different Monte Carlo scoring methods of dose average linear-energy-transfer maps calculated in voxelized geometries irradiated with clinical proton beams</title><title>Physics in medicine &amp; biology</title><addtitle>PMB</addtitle><addtitle>Phys. Med. Biol</addtitle><description>We compare unrestricted dose average linear energy transfer (LET) maps calculated with three different Monte Carlo scoring methods in voxelized geometries irradiated with proton therapy beams with three different Monte Carlo scoring methods. Simulations were done with the Geant4 (Geometry ANd Tracking) toolkit. The first method corresponds to a step-by-step computation of LET which has been reported previously in the literature. We found that this scoring strategy is influenced by spurious high LET components, which relative contribution in the dose average LET calculations significantly increases as the voxel size becomes smaller. Dose average LET values calculated for primary protons in water with voxel size of 0.2 mm were a factor ~1.8 higher than those obtained with a size of 2.0 mm at the plateau region for a 160 MeV beam. Such high LET components are a consequence of proton steps in which the condensed-history algorithm determines an energy transfer to an electron of the material close to the maximum value, while the step length remains limited due to voxel boundary crossing. Two alternative methods were derived to overcome this problem. The second scores LET along the entire path described by each proton within the voxel. The third followed the same approach of the first method, but the LET was evaluated at each step from stopping power tables according to the proton kinetic energy value. We carried out microdosimetry calculations with the aim of deriving reference dose average LET values from microdosimetric quantities. Significant differences between the methods were reported either with pristine or spread-out Bragg peaks (SOBPs). The first method reported values systematically higher than the other two at depths proximal to SOBP by about 15% for a 5.9 cm wide SOBP and about 30% for a 11.0 cm one. At distal SOBP, the second method gave values about 15% lower than the others. Overall, we found that the third method gave the most consistent performance since it returned stable dose average LET values against simulation parameter changes and gave the best agreement with dose average LET estimations from microdosimetry calculations.</description><subject>Algorithms</subject><subject>Geant4</subject><subject>LET</subject><subject>Linear Energy Transfer</subject><subject>Monte Carlo Method</subject><subject>Monte Carlo simulation</subject><subject>Proton Therapy</subject><subject>Radiometry - methods</subject><issn>0031-9155</issn><issn>1361-6560</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kctu1DAUQC0EokPhC5CQl2zS2ElsJ8tqxKNSERtYWzf2zdRVYg-2Uxg-im_EM1O6ZGVZOvdcW4eQt5xdcdb3NWMtrwYuRC1ZrepGduIZ2fBW8koKyZ6TzRNxQV6ldM8Y533TvSQXjVCyZ02_IX-uqYkuOwMzTXm1Bxomat00YUSf6ZfgM9ItxDnQZEJ0fkcXzHfBphMYElJ4wAg7pLPzCLFCj3F3qHIEn4qFLrBPtOjNOkNGS52nD-EXzu53uewwFF10mKiLEaw7IT9dvqOm-E7P2seQg6cjwpJekxcTzAnfPJ6X5PvHD9-2n6vbr59utte3lWk7kat2UGwUYgRlB4kjcGlUx5VFPg5isN1kRybtgAg4KGtGi0z1BkF0wOQ42faSvD97y_IfK6asF5cMzjN4DGvSXErZDKKXbUHbM2piSCnipPfRLRAPmjN9DKWPGfQxg5ZMK30MVabePS5YxwXt08y_MgWoz4ALe30f1ujLf_-r_AsaG6IZ</recordid><startdate>20150407</startdate><enddate>20150407</enddate><creator>Cortés-Giraldo, M A</creator><creator>Carabe, A</creator><general>IOP Publishing</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20150407</creationdate><title>A critical study of different Monte Carlo scoring methods of dose average linear-energy-transfer maps calculated in voxelized geometries irradiated with clinical proton beams</title><author>Cortés-Giraldo, M A ; Carabe, A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c345t-3970b55ba7d96eba16c7417de1b959d4fdb06d9eeae97dcbde078cea54a06bfd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Algorithms</topic><topic>Geant4</topic><topic>LET</topic><topic>Linear Energy Transfer</topic><topic>Monte Carlo Method</topic><topic>Monte Carlo simulation</topic><topic>Proton Therapy</topic><topic>Radiometry - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cortés-Giraldo, M A</creatorcontrib><creatorcontrib>Carabe, A</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Physics in medicine &amp; biology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cortés-Giraldo, M A</au><au>Carabe, A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A critical study of different Monte Carlo scoring methods of dose average linear-energy-transfer maps calculated in voxelized geometries irradiated with clinical proton beams</atitle><jtitle>Physics in medicine &amp; biology</jtitle><stitle>PMB</stitle><addtitle>Phys. Med. Biol</addtitle><date>2015-04-07</date><risdate>2015</risdate><volume>60</volume><issue>7</issue><spage>2645</spage><epage>2669</epage><pages>2645-2669</pages><issn>0031-9155</issn><eissn>1361-6560</eissn><coden>PHMBA7</coden><abstract>We compare unrestricted dose average linear energy transfer (LET) maps calculated with three different Monte Carlo scoring methods in voxelized geometries irradiated with proton therapy beams with three different Monte Carlo scoring methods. Simulations were done with the Geant4 (Geometry ANd Tracking) toolkit. The first method corresponds to a step-by-step computation of LET which has been reported previously in the literature. We found that this scoring strategy is influenced by spurious high LET components, which relative contribution in the dose average LET calculations significantly increases as the voxel size becomes smaller. Dose average LET values calculated for primary protons in water with voxel size of 0.2 mm were a factor ~1.8 higher than those obtained with a size of 2.0 mm at the plateau region for a 160 MeV beam. Such high LET components are a consequence of proton steps in which the condensed-history algorithm determines an energy transfer to an electron of the material close to the maximum value, while the step length remains limited due to voxel boundary crossing. Two alternative methods were derived to overcome this problem. The second scores LET along the entire path described by each proton within the voxel. The third followed the same approach of the first method, but the LET was evaluated at each step from stopping power tables according to the proton kinetic energy value. We carried out microdosimetry calculations with the aim of deriving reference dose average LET values from microdosimetric quantities. Significant differences between the methods were reported either with pristine or spread-out Bragg peaks (SOBPs). The first method reported values systematically higher than the other two at depths proximal to SOBP by about 15% for a 5.9 cm wide SOBP and about 30% for a 11.0 cm one. At distal SOBP, the second method gave values about 15% lower than the others. Overall, we found that the third method gave the most consistent performance since it returned stable dose average LET values against simulation parameter changes and gave the best agreement with dose average LET estimations from microdosimetry calculations.</abstract><cop>England</cop><pub>IOP Publishing</pub><pmid>25768028</pmid><doi>10.1088/0031-9155/60/7/2645</doi><tpages>25</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0031-9155
ispartof Physics in medicine & biology, 2015-04, Vol.60 (7), p.2645-2669
issn 0031-9155
1361-6560
language eng
recordid cdi_proquest_miscellaneous_1666295863
source MEDLINE; IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link
subjects Algorithms
Geant4
LET
Linear Energy Transfer
Monte Carlo Method
Monte Carlo simulation
Proton Therapy
Radiometry - methods
title A critical study of different Monte Carlo scoring methods of dose average linear-energy-transfer maps calculated in voxelized geometries irradiated with clinical proton beams
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-12T00%3A46%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20critical%20study%20of%20different%20Monte%20Carlo%20scoring%20methods%20of%20dose%20average%20linear-energy-transfer%20maps%20calculated%20in%20voxelized%20geometries%20irradiated%20with%20clinical%20proton%20beams&rft.jtitle=Physics%20in%20medicine%20&%20biology&rft.au=Cort%C3%A9s-Giraldo,%20M%20A&rft.date=2015-04-07&rft.volume=60&rft.issue=7&rft.spage=2645&rft.epage=2669&rft.pages=2645-2669&rft.issn=0031-9155&rft.eissn=1361-6560&rft.coden=PHMBA7&rft_id=info:doi/10.1088/0031-9155/60/7/2645&rft_dat=%3Cproquest_cross%3E1666295863%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1666295863&rft_id=info:pmid/25768028&rfr_iscdi=true