Quantification of alachlor in water by a novel magnetic particle-based ELISA

An enzyme-linked immunosorbent assay (ELISA) was developed for determination of the weedkiller, alachlor, in water, using a magnetic-particle solid phase. The water sample and alachlor labelled with horseradish peroxidase (HRP) were incubated for 30 minutes with the antibody-coupled solid phase, and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Bulletin of environmental contamination and toxicology 1992-05, Vol.48 (5), p.643-650
Hauptverfasser: Lawruk, T.S. (Ohmicron Corporation, Newtown, PA), Hottenstein, C.S, Herzog, D.P, Rubio, F.M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 650
container_issue 5
container_start_page 643
container_title Bulletin of environmental contamination and toxicology
container_volume 48
creator Lawruk, T.S. (Ohmicron Corporation, Newtown, PA)
Hottenstein, C.S
Herzog, D.P
Rubio, F.M
description An enzyme-linked immunosorbent assay (ELISA) was developed for determination of the weedkiller, alachlor, in water, using a magnetic-particle solid phase. The water sample and alachlor labelled with horseradish peroxidase (HRP) were incubated for 30 minutes with the antibody-coupled solid phase, and a magnetic field was then applied to the solid phase to remove unbound HRP-alachlor and any interfering substances. The enzyme substrate (hydrogen peroxide) and a chromogen (3,3',5,5'-tetramethylbenzidine) were then added and incubated for 20 minutes. Acid was added to stop the reaction, and the coloured product was measured with a specially-designed, microprocessor-controlled photometer. Results from validation of the method on samples of groundwater are presented.
doi_str_mv 10.1007/BF00195982
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_16629591</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>16629591</sourcerecordid><originalsourceid>FETCH-LOGICAL-c392t-19c590cbf24c2dd4871728ca98ea519ee8403b30d5c8b3ab3d213a0df17adf843</originalsourceid><addsrcrecordid>eNqF0EtLxDAUBeAgio6PjUtByEJcCNV7k6ZNliq-YEBEXZfbNNFKpx2TjuK_NzKDLl2dxfk4i8PYPsIpApRnF9cAaJTRYo1NMJciAw2wziaQ2izXBW6x7RjfklJaiE22iQpyhTBh04cF9WPrW0tjO_R88Jw6sq_dEHjb808aXeD1FyfeDx-u4zN66d3YWj6nkKJzWU3RNfxqevd4vss2PHXR7a1yhz1fXz1d3mbT-5u7y_NpZqURY4bGKgO29iK3omlyXWIptCWjHSk0zukcZC2hUVbXkmrZCJQEjceSGq9zucOOl7vzMLwvXByrWRut6zrq3bCIFRaFSHfg_1CWqJQxCZ4soQ1DjMH5ah7aGYWvCqH6-bj6-zjhw9Xqop655o8uT0390aqnaKnzgXrbxl-mRFlAoRM7WDJPQ0UvIZHnR4NaFbKU3-LbibA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>13715599</pqid></control><display><type>article</type><title>Quantification of alachlor in water by a novel magnetic particle-based ELISA</title><source>MEDLINE</source><source>SpringerLink Journals</source><creator>Lawruk, T.S. (Ohmicron Corporation, Newtown, PA) ; Hottenstein, C.S ; Herzog, D.P ; Rubio, F.M</creator><creatorcontrib>Lawruk, T.S. (Ohmicron Corporation, Newtown, PA) ; Hottenstein, C.S ; Herzog, D.P ; Rubio, F.M</creatorcontrib><description>An enzyme-linked immunosorbent assay (ELISA) was developed for determination of the weedkiller, alachlor, in water, using a magnetic-particle solid phase. The water sample and alachlor labelled with horseradish peroxidase (HRP) were incubated for 30 minutes with the antibody-coupled solid phase, and a magnetic field was then applied to the solid phase to remove unbound HRP-alachlor and any interfering substances. The enzyme substrate (hydrogen peroxide) and a chromogen (3,3',5,5'-tetramethylbenzidine) were then added and incubated for 20 minutes. Acid was added to stop the reaction, and the coloured product was measured with a specially-designed, microprocessor-controlled photometer. Results from validation of the method on samples of groundwater are presented.</description><identifier>ISSN: 0007-4861</identifier><identifier>EISSN: 1432-0800</identifier><identifier>DOI: 10.1007/BF00195982</identifier><identifier>PMID: 1504510</identifier><identifier>CODEN: BECTA6</identifier><language>eng</language><publisher>New York, NY: Springer-Verlag</publisher><subject>Acetamides - analysis ; AGUAS SUBTERRANEAS ; ALACHLOR ; ALACHLORE ; ALACLORO ; ANALISIS CUANTITATIVO ; ANALYSE QUANTITATIVE ; Benzidines ; Biological and medical sciences ; Calibration ; CALIDAD DEL AGUA ; Chromogenic Compounds ; CLASIFICACION DE PRODUCTOS ; CLASSEMENT ; Cross Reactions ; EAU SOUTERRAINE ; ELISA ; ENSAYO ; Environmental pollutants toxicology ; Enzyme-Linked Immunosorbent Assay - methods ; Evaluation Studies as Topic ; Freshwater ; GRADING ; GROUNDWATER ; HERBICIDAS ; HERBICIDE ; HERBICIDES ; Herbicides - analysis ; Horseradish Peroxidase ; Hydrogen Peroxide ; MAGNETIC SEPARATION ; Magnetics ; Medical sciences ; QUALITE DE L'EAU ; QUANTITATIVE ANALYSIS ; RESIDU ; RESIDUES ; RESIDUOS ; TEST ELISA ; TESTAGE ; TESTING ; Toxicology ; Water ; Water Pollutants, Chemical - analysis ; WATER QUALITY</subject><ispartof>Bulletin of environmental contamination and toxicology, 1992-05, Vol.48 (5), p.643-650</ispartof><rights>1992 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c392t-19c590cbf24c2dd4871728ca98ea519ee8403b30d5c8b3ab3d213a0df17adf843</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=5276068$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/1504510$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lawruk, T.S. (Ohmicron Corporation, Newtown, PA)</creatorcontrib><creatorcontrib>Hottenstein, C.S</creatorcontrib><creatorcontrib>Herzog, D.P</creatorcontrib><creatorcontrib>Rubio, F.M</creatorcontrib><title>Quantification of alachlor in water by a novel magnetic particle-based ELISA</title><title>Bulletin of environmental contamination and toxicology</title><addtitle>Bull Environ Contam Toxicol</addtitle><description>An enzyme-linked immunosorbent assay (ELISA) was developed for determination of the weedkiller, alachlor, in water, using a magnetic-particle solid phase. The water sample and alachlor labelled with horseradish peroxidase (HRP) were incubated for 30 minutes with the antibody-coupled solid phase, and a magnetic field was then applied to the solid phase to remove unbound HRP-alachlor and any interfering substances. The enzyme substrate (hydrogen peroxide) and a chromogen (3,3',5,5'-tetramethylbenzidine) were then added and incubated for 20 minutes. Acid was added to stop the reaction, and the coloured product was measured with a specially-designed, microprocessor-controlled photometer. Results from validation of the method on samples of groundwater are presented.</description><subject>Acetamides - analysis</subject><subject>AGUAS SUBTERRANEAS</subject><subject>ALACHLOR</subject><subject>ALACHLORE</subject><subject>ALACLORO</subject><subject>ANALISIS CUANTITATIVO</subject><subject>ANALYSE QUANTITATIVE</subject><subject>Benzidines</subject><subject>Biological and medical sciences</subject><subject>Calibration</subject><subject>CALIDAD DEL AGUA</subject><subject>Chromogenic Compounds</subject><subject>CLASIFICACION DE PRODUCTOS</subject><subject>CLASSEMENT</subject><subject>Cross Reactions</subject><subject>EAU SOUTERRAINE</subject><subject>ELISA</subject><subject>ENSAYO</subject><subject>Environmental pollutants toxicology</subject><subject>Enzyme-Linked Immunosorbent Assay - methods</subject><subject>Evaluation Studies as Topic</subject><subject>Freshwater</subject><subject>GRADING</subject><subject>GROUNDWATER</subject><subject>HERBICIDAS</subject><subject>HERBICIDE</subject><subject>HERBICIDES</subject><subject>Herbicides - analysis</subject><subject>Horseradish Peroxidase</subject><subject>Hydrogen Peroxide</subject><subject>MAGNETIC SEPARATION</subject><subject>Magnetics</subject><subject>Medical sciences</subject><subject>QUALITE DE L'EAU</subject><subject>QUANTITATIVE ANALYSIS</subject><subject>RESIDU</subject><subject>RESIDUES</subject><subject>RESIDUOS</subject><subject>TEST ELISA</subject><subject>TESTAGE</subject><subject>TESTING</subject><subject>Toxicology</subject><subject>Water</subject><subject>Water Pollutants, Chemical - analysis</subject><subject>WATER QUALITY</subject><issn>0007-4861</issn><issn>1432-0800</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1992</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqF0EtLxDAUBeAgio6PjUtByEJcCNV7k6ZNliq-YEBEXZfbNNFKpx2TjuK_NzKDLl2dxfk4i8PYPsIpApRnF9cAaJTRYo1NMJciAw2wziaQ2izXBW6x7RjfklJaiE22iQpyhTBh04cF9WPrW0tjO_R88Jw6sq_dEHjb808aXeD1FyfeDx-u4zN66d3YWj6nkKJzWU3RNfxqevd4vss2PHXR7a1yhz1fXz1d3mbT-5u7y_NpZqURY4bGKgO29iK3omlyXWIptCWjHSk0zukcZC2hUVbXkmrZCJQEjceSGq9zucOOl7vzMLwvXByrWRut6zrq3bCIFRaFSHfg_1CWqJQxCZ4soQ1DjMH5ah7aGYWvCqH6-bj6-zjhw9Xqop655o8uT0390aqnaKnzgXrbxl-mRFlAoRM7WDJPQ0UvIZHnR4NaFbKU3-LbibA</recordid><startdate>19920501</startdate><enddate>19920501</enddate><creator>Lawruk, T.S. (Ohmicron Corporation, Newtown, PA)</creator><creator>Hottenstein, C.S</creator><creator>Herzog, D.P</creator><creator>Rubio, F.M</creator><general>Springer-Verlag</general><scope>FBQ</scope><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QH</scope><scope>7TV</scope><scope>7UA</scope><scope>8FD</scope><scope>C1K</scope><scope>F1W</scope><scope>FR3</scope><scope>H97</scope><scope>H99</scope><scope>L.F</scope><scope>L.G</scope><scope>P64</scope></search><sort><creationdate>19920501</creationdate><title>Quantification of alachlor in water by a novel magnetic particle-based ELISA</title><author>Lawruk, T.S. (Ohmicron Corporation, Newtown, PA) ; Hottenstein, C.S ; Herzog, D.P ; Rubio, F.M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c392t-19c590cbf24c2dd4871728ca98ea519ee8403b30d5c8b3ab3d213a0df17adf843</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1992</creationdate><topic>Acetamides - analysis</topic><topic>AGUAS SUBTERRANEAS</topic><topic>ALACHLOR</topic><topic>ALACHLORE</topic><topic>ALACLORO</topic><topic>ANALISIS CUANTITATIVO</topic><topic>ANALYSE QUANTITATIVE</topic><topic>Benzidines</topic><topic>Biological and medical sciences</topic><topic>Calibration</topic><topic>CALIDAD DEL AGUA</topic><topic>Chromogenic Compounds</topic><topic>CLASIFICACION DE PRODUCTOS</topic><topic>CLASSEMENT</topic><topic>Cross Reactions</topic><topic>EAU SOUTERRAINE</topic><topic>ELISA</topic><topic>ENSAYO</topic><topic>Environmental pollutants toxicology</topic><topic>Enzyme-Linked Immunosorbent Assay - methods</topic><topic>Evaluation Studies as Topic</topic><topic>Freshwater</topic><topic>GRADING</topic><topic>GROUNDWATER</topic><topic>HERBICIDAS</topic><topic>HERBICIDE</topic><topic>HERBICIDES</topic><topic>Herbicides - analysis</topic><topic>Horseradish Peroxidase</topic><topic>Hydrogen Peroxide</topic><topic>MAGNETIC SEPARATION</topic><topic>Magnetics</topic><topic>Medical sciences</topic><topic>QUALITE DE L'EAU</topic><topic>QUANTITATIVE ANALYSIS</topic><topic>RESIDU</topic><topic>RESIDUES</topic><topic>RESIDUOS</topic><topic>TEST ELISA</topic><topic>TESTAGE</topic><topic>TESTING</topic><topic>Toxicology</topic><topic>Water</topic><topic>Water Pollutants, Chemical - analysis</topic><topic>WATER QUALITY</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lawruk, T.S. (Ohmicron Corporation, Newtown, PA)</creatorcontrib><creatorcontrib>Hottenstein, C.S</creatorcontrib><creatorcontrib>Herzog, D.P</creatorcontrib><creatorcontrib>Rubio, F.M</creatorcontrib><collection>AGRIS</collection><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Aqualine</collection><collection>Pollution Abstracts</collection><collection>Water Resources Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ASFA: Aquatic Sciences and Fisheries Abstracts</collection><collection>Engineering Research Database</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) 3: Aquatic Pollution &amp; Environmental Quality</collection><collection>ASFA: Marine Biotechnology Abstracts</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) Marine Biotechnology Abstracts</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Bulletin of environmental contamination and toxicology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lawruk, T.S. (Ohmicron Corporation, Newtown, PA)</au><au>Hottenstein, C.S</au><au>Herzog, D.P</au><au>Rubio, F.M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Quantification of alachlor in water by a novel magnetic particle-based ELISA</atitle><jtitle>Bulletin of environmental contamination and toxicology</jtitle><addtitle>Bull Environ Contam Toxicol</addtitle><date>1992-05-01</date><risdate>1992</risdate><volume>48</volume><issue>5</issue><spage>643</spage><epage>650</epage><pages>643-650</pages><issn>0007-4861</issn><eissn>1432-0800</eissn><coden>BECTA6</coden><abstract>An enzyme-linked immunosorbent assay (ELISA) was developed for determination of the weedkiller, alachlor, in water, using a magnetic-particle solid phase. The water sample and alachlor labelled with horseradish peroxidase (HRP) were incubated for 30 minutes with the antibody-coupled solid phase, and a magnetic field was then applied to the solid phase to remove unbound HRP-alachlor and any interfering substances. The enzyme substrate (hydrogen peroxide) and a chromogen (3,3',5,5'-tetramethylbenzidine) were then added and incubated for 20 minutes. Acid was added to stop the reaction, and the coloured product was measured with a specially-designed, microprocessor-controlled photometer. Results from validation of the method on samples of groundwater are presented.</abstract><cop>New York, NY</cop><pub>Springer-Verlag</pub><pmid>1504510</pmid><doi>10.1007/BF00195982</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0007-4861
ispartof Bulletin of environmental contamination and toxicology, 1992-05, Vol.48 (5), p.643-650
issn 0007-4861
1432-0800
language eng
recordid cdi_proquest_miscellaneous_16629591
source MEDLINE; SpringerLink Journals
subjects Acetamides - analysis
AGUAS SUBTERRANEAS
ALACHLOR
ALACHLORE
ALACLORO
ANALISIS CUANTITATIVO
ANALYSE QUANTITATIVE
Benzidines
Biological and medical sciences
Calibration
CALIDAD DEL AGUA
Chromogenic Compounds
CLASIFICACION DE PRODUCTOS
CLASSEMENT
Cross Reactions
EAU SOUTERRAINE
ELISA
ENSAYO
Environmental pollutants toxicology
Enzyme-Linked Immunosorbent Assay - methods
Evaluation Studies as Topic
Freshwater
GRADING
GROUNDWATER
HERBICIDAS
HERBICIDE
HERBICIDES
Herbicides - analysis
Horseradish Peroxidase
Hydrogen Peroxide
MAGNETIC SEPARATION
Magnetics
Medical sciences
QUALITE DE L'EAU
QUANTITATIVE ANALYSIS
RESIDU
RESIDUES
RESIDUOS
TEST ELISA
TESTAGE
TESTING
Toxicology
Water
Water Pollutants, Chemical - analysis
WATER QUALITY
title Quantification of alachlor in water by a novel magnetic particle-based ELISA
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-13T13%3A45%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Quantification%20of%20alachlor%20in%20water%20by%20a%20novel%20magnetic%20particle-based%20ELISA&rft.jtitle=Bulletin%20of%20environmental%20contamination%20and%20toxicology&rft.au=Lawruk,%20T.S.%20(Ohmicron%20Corporation,%20Newtown,%20PA)&rft.date=1992-05-01&rft.volume=48&rft.issue=5&rft.spage=643&rft.epage=650&rft.pages=643-650&rft.issn=0007-4861&rft.eissn=1432-0800&rft.coden=BECTA6&rft_id=info:doi/10.1007/BF00195982&rft_dat=%3Cproquest_cross%3E16629591%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=13715599&rft_id=info:pmid/1504510&rfr_iscdi=true