A source-independent empirical correction procedure for the fast mobility and engine exhaust particle sizers
The TSI Fast Mobility Particle Sizer (FMPS) and Engine Exhaust Particle Sizer (EEPS) provide size distributions for 6–560 nm particles with a time resolution suitable for characterizing transient particle sources; however, the accuracy of these instruments can be source dependent, due to influences...
Gespeichert in:
Veröffentlicht in: | Atmospheric environment (1994) 2015-01, Vol.100, p.178-184 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 184 |
---|---|
container_issue | |
container_start_page | 178 |
container_title | Atmospheric environment (1994) |
container_volume | 100 |
creator | Zimmerman, Naomi Jeong, Cheol-Heon Wang, Jonathan M. Ramos, Manuel Wallace, James S. Evans, Greg J. |
description | The TSI Fast Mobility Particle Sizer (FMPS) and Engine Exhaust Particle Sizer (EEPS) provide size distributions for 6–560 nm particles with a time resolution suitable for characterizing transient particle sources; however, the accuracy of these instruments can be source dependent, due to influences of particle morphology. The aim of this study was to develop a source-independent correction protocol for the FMPS and EEPS. The correction protocol consists of: (1) broadening the >80 nm size range of the distribution to account for under-sizing by the FMPS and EEPS; (2) applying an existing correction protocol in the 8–93 nm size range; and (3) dividing each size bin by the ratio of total concentration measured by the FMPS or EEPS and a water-based Condensation Particle Counter (CPC) as a surrogate scaling factor to account for particle morphology. Efficacy of the correction protocol was assessed for three sources: urban ambient air, diluted gasoline direct injection engine exhaust, and diluted diesel engine exhaust. Linear regression against a reference instrument, the Scanning Mobility Particle Sizer (SMPS), before and after applying the correction protocol demonstrated that the correction ensured agreement within 20%.
•Accuracy of high time resolution particle sizers is affected by particle morphology.•These instruments also under-size particles larger than 80 nm.•We provide a source-independent correction protocol to address this issue.•The correction protocol ensures agreement within 20% of a reference instrument. |
doi_str_mv | 10.1016/j.atmosenv.2014.10.054 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1660092298</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1352231014008516</els_id><sourcerecordid>1647003625</sourcerecordid><originalsourceid>FETCH-LOGICAL-c426t-da4aba2534530b73a5ec78b5aaa389e7a52f483ae474b2f249a2a279902c05d63</originalsourceid><addsrcrecordid>eNqNUU1P3DAQtRBIwJa_gHzsJVvHduLk1tWKj0pIvbRna-JMwKvEDrazYvn1eLVwbi_zRm8-NPMeIbclW5esrH_s1pAmH9Ht15yVMpNrVskzclU2ShS8kfI856LiBRcluyTXMe4YY0K16oqMGxr9EgwW1vU4Yw4uUZxmG6yBkRofAppkvaNz8Ab7JSAdfKDpJSPERCff2dGmAwXXU3TP1iHFtxdYcm2GkKwZkUb7jiF-IxcDjBFvPnFF_t7f_dk-Fk-_H35tN0-FkbxORQ8SOuCVkJVgnRJQoVFNVwGAaFpUUPFBNgJQKtnxgcsWOHDVtowbVvW1WJHvp7355NcFY9KTjQbHERz6JeqyrhlrOW-b_2iVKmtV52tWpD61muBjDDjoOdgJwkGXTB-d0Dv95YQ-OnHksxN58OdpEPPPe4tBR2PRZTHtUVvde_uvFR8QMJdc</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1647003625</pqid></control><display><type>article</type><title>A source-independent empirical correction procedure for the fast mobility and engine exhaust particle sizers</title><source>Elsevier ScienceDirect Journals</source><creator>Zimmerman, Naomi ; Jeong, Cheol-Heon ; Wang, Jonathan M. ; Ramos, Manuel ; Wallace, James S. ; Evans, Greg J.</creator><creatorcontrib>Zimmerman, Naomi ; Jeong, Cheol-Heon ; Wang, Jonathan M. ; Ramos, Manuel ; Wallace, James S. ; Evans, Greg J.</creatorcontrib><description>The TSI Fast Mobility Particle Sizer (FMPS) and Engine Exhaust Particle Sizer (EEPS) provide size distributions for 6–560 nm particles with a time resolution suitable for characterizing transient particle sources; however, the accuracy of these instruments can be source dependent, due to influences of particle morphology. The aim of this study was to develop a source-independent correction protocol for the FMPS and EEPS. The correction protocol consists of: (1) broadening the >80 nm size range of the distribution to account for under-sizing by the FMPS and EEPS; (2) applying an existing correction protocol in the 8–93 nm size range; and (3) dividing each size bin by the ratio of total concentration measured by the FMPS or EEPS and a water-based Condensation Particle Counter (CPC) as a surrogate scaling factor to account for particle morphology. Efficacy of the correction protocol was assessed for three sources: urban ambient air, diluted gasoline direct injection engine exhaust, and diluted diesel engine exhaust. Linear regression against a reference instrument, the Scanning Mobility Particle Sizer (SMPS), before and after applying the correction protocol demonstrated that the correction ensured agreement within 20%.
•Accuracy of high time resolution particle sizers is affected by particle morphology.•These instruments also under-size particles larger than 80 nm.•We provide a source-independent correction protocol to address this issue.•The correction protocol ensures agreement within 20% of a reference instrument.</description><identifier>ISSN: 1352-2310</identifier><identifier>EISSN: 1873-2844</identifier><identifier>DOI: 10.1016/j.atmosenv.2014.10.054</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Diesel engines ; Dilution ; EEPS ; Effectiveness ; Engines ; Exhaust ; FMPS ; Morphology ; Particle size distributions ; Regression ; Scanning ; SMPS ; Vehicle emissions</subject><ispartof>Atmospheric environment (1994), 2015-01, Vol.100, p.178-184</ispartof><rights>2014 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c426t-da4aba2534530b73a5ec78b5aaa389e7a52f483ae474b2f249a2a279902c05d63</citedby><cites>FETCH-LOGICAL-c426t-da4aba2534530b73a5ec78b5aaa389e7a52f483ae474b2f249a2a279902c05d63</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S1352231014008516$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids></links><search><creatorcontrib>Zimmerman, Naomi</creatorcontrib><creatorcontrib>Jeong, Cheol-Heon</creatorcontrib><creatorcontrib>Wang, Jonathan M.</creatorcontrib><creatorcontrib>Ramos, Manuel</creatorcontrib><creatorcontrib>Wallace, James S.</creatorcontrib><creatorcontrib>Evans, Greg J.</creatorcontrib><title>A source-independent empirical correction procedure for the fast mobility and engine exhaust particle sizers</title><title>Atmospheric environment (1994)</title><description>The TSI Fast Mobility Particle Sizer (FMPS) and Engine Exhaust Particle Sizer (EEPS) provide size distributions for 6–560 nm particles with a time resolution suitable for characterizing transient particle sources; however, the accuracy of these instruments can be source dependent, due to influences of particle morphology. The aim of this study was to develop a source-independent correction protocol for the FMPS and EEPS. The correction protocol consists of: (1) broadening the >80 nm size range of the distribution to account for under-sizing by the FMPS and EEPS; (2) applying an existing correction protocol in the 8–93 nm size range; and (3) dividing each size bin by the ratio of total concentration measured by the FMPS or EEPS and a water-based Condensation Particle Counter (CPC) as a surrogate scaling factor to account for particle morphology. Efficacy of the correction protocol was assessed for three sources: urban ambient air, diluted gasoline direct injection engine exhaust, and diluted diesel engine exhaust. Linear regression against a reference instrument, the Scanning Mobility Particle Sizer (SMPS), before and after applying the correction protocol demonstrated that the correction ensured agreement within 20%.
•Accuracy of high time resolution particle sizers is affected by particle morphology.•These instruments also under-size particles larger than 80 nm.•We provide a source-independent correction protocol to address this issue.•The correction protocol ensures agreement within 20% of a reference instrument.</description><subject>Diesel engines</subject><subject>Dilution</subject><subject>EEPS</subject><subject>Effectiveness</subject><subject>Engines</subject><subject>Exhaust</subject><subject>FMPS</subject><subject>Morphology</subject><subject>Particle size distributions</subject><subject>Regression</subject><subject>Scanning</subject><subject>SMPS</subject><subject>Vehicle emissions</subject><issn>1352-2310</issn><issn>1873-2844</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNqNUU1P3DAQtRBIwJa_gHzsJVvHduLk1tWKj0pIvbRna-JMwKvEDrazYvn1eLVwbi_zRm8-NPMeIbclW5esrH_s1pAmH9Ht15yVMpNrVskzclU2ShS8kfI856LiBRcluyTXMe4YY0K16oqMGxr9EgwW1vU4Yw4uUZxmG6yBkRofAppkvaNz8Ab7JSAdfKDpJSPERCff2dGmAwXXU3TP1iHFtxdYcm2GkKwZkUb7jiF-IxcDjBFvPnFF_t7f_dk-Fk-_H35tN0-FkbxORQ8SOuCVkJVgnRJQoVFNVwGAaFpUUPFBNgJQKtnxgcsWOHDVtowbVvW1WJHvp7355NcFY9KTjQbHERz6JeqyrhlrOW-b_2iVKmtV52tWpD61muBjDDjoOdgJwkGXTB-d0Dv95YQ-OnHksxN58OdpEPPPe4tBR2PRZTHtUVvde_uvFR8QMJdc</recordid><startdate>201501</startdate><enddate>201501</enddate><creator>Zimmerman, Naomi</creator><creator>Jeong, Cheol-Heon</creator><creator>Wang, Jonathan M.</creator><creator>Ramos, Manuel</creator><creator>Wallace, James S.</creator><creator>Evans, Greg J.</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>7TG</scope><scope>7TV</scope><scope>7UA</scope><scope>C1K</scope><scope>F1W</scope><scope>H96</scope><scope>KL.</scope><scope>L.G</scope><scope>SOI</scope><scope>7SU</scope><scope>8FD</scope><scope>FR3</scope><scope>H8D</scope><scope>KR7</scope><scope>L7M</scope></search><sort><creationdate>201501</creationdate><title>A source-independent empirical correction procedure for the fast mobility and engine exhaust particle sizers</title><author>Zimmerman, Naomi ; Jeong, Cheol-Heon ; Wang, Jonathan M. ; Ramos, Manuel ; Wallace, James S. ; Evans, Greg J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c426t-da4aba2534530b73a5ec78b5aaa389e7a52f483ae474b2f249a2a279902c05d63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Diesel engines</topic><topic>Dilution</topic><topic>EEPS</topic><topic>Effectiveness</topic><topic>Engines</topic><topic>Exhaust</topic><topic>FMPS</topic><topic>Morphology</topic><topic>Particle size distributions</topic><topic>Regression</topic><topic>Scanning</topic><topic>SMPS</topic><topic>Vehicle emissions</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zimmerman, Naomi</creatorcontrib><creatorcontrib>Jeong, Cheol-Heon</creatorcontrib><creatorcontrib>Wang, Jonathan M.</creatorcontrib><creatorcontrib>Ramos, Manuel</creatorcontrib><creatorcontrib>Wallace, James S.</creatorcontrib><creatorcontrib>Evans, Greg J.</creatorcontrib><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Meteorological & Geoastrophysical Abstracts</collection><collection>Pollution Abstracts</collection><collection>Water Resources Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ASFA: Aquatic Sciences and Fisheries Abstracts</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) 2: Ocean Technology, Policy & Non-Living Resources</collection><collection>Meteorological & Geoastrophysical Abstracts - Academic</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) Professional</collection><collection>Environment Abstracts</collection><collection>Environmental Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Atmospheric environment (1994)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zimmerman, Naomi</au><au>Jeong, Cheol-Heon</au><au>Wang, Jonathan M.</au><au>Ramos, Manuel</au><au>Wallace, James S.</au><au>Evans, Greg J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A source-independent empirical correction procedure for the fast mobility and engine exhaust particle sizers</atitle><jtitle>Atmospheric environment (1994)</jtitle><date>2015-01</date><risdate>2015</risdate><volume>100</volume><spage>178</spage><epage>184</epage><pages>178-184</pages><issn>1352-2310</issn><eissn>1873-2844</eissn><abstract>The TSI Fast Mobility Particle Sizer (FMPS) and Engine Exhaust Particle Sizer (EEPS) provide size distributions for 6–560 nm particles with a time resolution suitable for characterizing transient particle sources; however, the accuracy of these instruments can be source dependent, due to influences of particle morphology. The aim of this study was to develop a source-independent correction protocol for the FMPS and EEPS. The correction protocol consists of: (1) broadening the >80 nm size range of the distribution to account for under-sizing by the FMPS and EEPS; (2) applying an existing correction protocol in the 8–93 nm size range; and (3) dividing each size bin by the ratio of total concentration measured by the FMPS or EEPS and a water-based Condensation Particle Counter (CPC) as a surrogate scaling factor to account for particle morphology. Efficacy of the correction protocol was assessed for three sources: urban ambient air, diluted gasoline direct injection engine exhaust, and diluted diesel engine exhaust. Linear regression against a reference instrument, the Scanning Mobility Particle Sizer (SMPS), before and after applying the correction protocol demonstrated that the correction ensured agreement within 20%.
•Accuracy of high time resolution particle sizers is affected by particle morphology.•These instruments also under-size particles larger than 80 nm.•We provide a source-independent correction protocol to address this issue.•The correction protocol ensures agreement within 20% of a reference instrument.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.atmosenv.2014.10.054</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1352-2310 |
ispartof | Atmospheric environment (1994), 2015-01, Vol.100, p.178-184 |
issn | 1352-2310 1873-2844 |
language | eng |
recordid | cdi_proquest_miscellaneous_1660092298 |
source | Elsevier ScienceDirect Journals |
subjects | Diesel engines Dilution EEPS Effectiveness Engines Exhaust FMPS Morphology Particle size distributions Regression Scanning SMPS Vehicle emissions |
title | A source-independent empirical correction procedure for the fast mobility and engine exhaust particle sizers |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-11T14%3A20%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20source-independent%20empirical%20correction%20procedure%20for%20the%20fast%20mobility%20and%20engine%20exhaust%20particle%20sizers&rft.jtitle=Atmospheric%20environment%20(1994)&rft.au=Zimmerman,%20Naomi&rft.date=2015-01&rft.volume=100&rft.spage=178&rft.epage=184&rft.pages=178-184&rft.issn=1352-2310&rft.eissn=1873-2844&rft_id=info:doi/10.1016/j.atmosenv.2014.10.054&rft_dat=%3Cproquest_cross%3E1647003625%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1647003625&rft_id=info:pmid/&rft_els_id=S1352231014008516&rfr_iscdi=true |