Investigations on the emissions of biocides and PCBs under low volume conditions

•Dynamic conditions are essential for a quantitative SVOC analysis in air-tight showcases.•Diffusive sampling in air-tight showcases allows the detection of more SVOCs than active sampling.•By increasing the air sampling volume the amount of detectable higher boiling SVOCs is increased.•Increasing t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chemosphere (Oxford) 2015-01, Vol.118, p.65-71
Hauptverfasser: Mull, Birte, Horn, Wolfgang, Jann, Oliver
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 71
container_issue
container_start_page 65
container_title Chemosphere (Oxford)
container_volume 118
creator Mull, Birte
Horn, Wolfgang
Jann, Oliver
description •Dynamic conditions are essential for a quantitative SVOC analysis in air-tight showcases.•Diffusive sampling in air-tight showcases allows the detection of more SVOCs than active sampling.•By increasing the air sampling volume the amount of detectable higher boiling SVOCs is increased.•Increasing temperatures decrease the emission time above the corresponding limits of quantification. The aim of this study was the development of a low volume air sampling strategy for biocides and polychlorinated biphenyls (PCB) at low air change rates in modern, air-tight showcases as they are present in museums. Lindane, pentachlorophenol, dichlofluanid, tolyfluanid, isodrin, p,p-dichlorodiphenyl trichloroethane and permethrin were the biocides and PCB28 and PCB153 were the PCBs studied, all of which are semi volatile organic compounds (SVOC). Their occurrences in the museum environment originate from various sources e.g. preventive treatment of organic exhibits or organic building materials. Exhibits are long-term exposed to these pollutants due to storing in showcases or other storage equipment at low air change rates. To achieve air sampling under the aforementioned conditions the influences of temperature, air circulation, air change rate and relative humidity on the emission behavior of the selected biocides and PCBs had to be determined. This was carried out with pre-soaked wood samples in low volume air sampling experiments using 27L test showcases and 23L and 24L emission test chambers and also diffusive sampling with glass as the sampling material.
doi_str_mv 10.1016/j.chemosphere.2014.06.021
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1660086046</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0045653514007577</els_id><sourcerecordid>1654683229</sourcerecordid><originalsourceid>FETCH-LOGICAL-c443t-82a7b4a672131a0835212e4f791aad83cfe205dbb4c0bb00c0c4e8beb3f850963</originalsourceid><addsrcrecordid>eNqNkU2P0zAQhi0EYsvCX0DmxiVh7Niuc4RqgZVWYg9wtvwxoa6SuNhJEf8eL10Qx548sp53xp6HkDcMWgZMvTu0fo9TKsc9Zmw5MNGCaoGzJ2TD9LZvGO_1U7IBELJRspNX5EUpB4Aalv1zcsVlrQVjG3J_O5-wLPG7XWKaC00zXfZIcYqlnC8G6mLyMWChdg70fveh0HUOmOmYftJTGtcJqU9ziH86vCTPBjsWfPV4XpNvH2--7j43d18-3e7e3zVeiG5pNLdbJ6zactYxC7qTnHEUw7Zn1gbd-QE5yOCc8OAcgAcvUDt03aAl9Kq7Jm_PfY85_VjrF0x9ssdxtDOmtRimFIBWIC5BpVC647y_AOW91JKDqGh_Rn1OpWQczDHHyeZfhoF50GQO5j9N5kGTAWWqppp9_ThmdROGf8m_XiqwOwNYV3iKmE3xEWePIWb0iwkpXjDmN8UFqOA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1629585204</pqid></control><display><type>article</type><title>Investigations on the emissions of biocides and PCBs under low volume conditions</title><source>MEDLINE</source><source>ScienceDirect Freedom Collection (Elsevier)</source><creator>Mull, Birte ; Horn, Wolfgang ; Jann, Oliver</creator><creatorcontrib>Mull, Birte ; Horn, Wolfgang ; Jann, Oliver</creatorcontrib><description>•Dynamic conditions are essential for a quantitative SVOC analysis in air-tight showcases.•Diffusive sampling in air-tight showcases allows the detection of more SVOCs than active sampling.•By increasing the air sampling volume the amount of detectable higher boiling SVOCs is increased.•Increasing temperatures decrease the emission time above the corresponding limits of quantification. The aim of this study was the development of a low volume air sampling strategy for biocides and polychlorinated biphenyls (PCB) at low air change rates in modern, air-tight showcases as they are present in museums. Lindane, pentachlorophenol, dichlofluanid, tolyfluanid, isodrin, p,p-dichlorodiphenyl trichloroethane and permethrin were the biocides and PCB28 and PCB153 were the PCBs studied, all of which are semi volatile organic compounds (SVOC). Their occurrences in the museum environment originate from various sources e.g. preventive treatment of organic exhibits or organic building materials. Exhibits are long-term exposed to these pollutants due to storing in showcases or other storage equipment at low air change rates. To achieve air sampling under the aforementioned conditions the influences of temperature, air circulation, air change rate and relative humidity on the emission behavior of the selected biocides and PCBs had to be determined. This was carried out with pre-soaked wood samples in low volume air sampling experiments using 27L test showcases and 23L and 24L emission test chambers and also diffusive sampling with glass as the sampling material.</description><identifier>ISSN: 0045-6535</identifier><identifier>EISSN: 1879-1298</identifier><identifier>DOI: 10.1016/j.chemosphere.2014.06.021</identifier><identifier>PMID: 25000411</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>Air Pollutants - analysis ; Air sampling ; Biocides ; Disinfectants - analysis ; Emission analysis ; Emission test chamber ; Environmental Monitoring - methods ; Gas Chromatography-Mass Spectrometry ; Museums ; Polychlorinated biphenyls ; Polychlorinated Biphenyls - analysis ; Sampling ; SDVB-polymer ; Showcase ; Showcases ; SVOC ; Tandem Mass Spectrometry ; Volatile Organic Compounds - analysis ; Wood</subject><ispartof>Chemosphere (Oxford), 2015-01, Vol.118, p.65-71</ispartof><rights>2014 Elsevier Ltd</rights><rights>Copyright © 2014 Elsevier Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c443t-82a7b4a672131a0835212e4f791aad83cfe205dbb4c0bb00c0c4e8beb3f850963</citedby><cites>FETCH-LOGICAL-c443t-82a7b4a672131a0835212e4f791aad83cfe205dbb4c0bb00c0c4e8beb3f850963</cites><orcidid>0000-0002-4936-9605 ; 0000-0003-3926-4081</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.chemosphere.2014.06.021$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3548,27923,27924,45994</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25000411$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Mull, Birte</creatorcontrib><creatorcontrib>Horn, Wolfgang</creatorcontrib><creatorcontrib>Jann, Oliver</creatorcontrib><title>Investigations on the emissions of biocides and PCBs under low volume conditions</title><title>Chemosphere (Oxford)</title><addtitle>Chemosphere</addtitle><description>•Dynamic conditions are essential for a quantitative SVOC analysis in air-tight showcases.•Diffusive sampling in air-tight showcases allows the detection of more SVOCs than active sampling.•By increasing the air sampling volume the amount of detectable higher boiling SVOCs is increased.•Increasing temperatures decrease the emission time above the corresponding limits of quantification. The aim of this study was the development of a low volume air sampling strategy for biocides and polychlorinated biphenyls (PCB) at low air change rates in modern, air-tight showcases as they are present in museums. Lindane, pentachlorophenol, dichlofluanid, tolyfluanid, isodrin, p,p-dichlorodiphenyl trichloroethane and permethrin were the biocides and PCB28 and PCB153 were the PCBs studied, all of which are semi volatile organic compounds (SVOC). Their occurrences in the museum environment originate from various sources e.g. preventive treatment of organic exhibits or organic building materials. Exhibits are long-term exposed to these pollutants due to storing in showcases or other storage equipment at low air change rates. To achieve air sampling under the aforementioned conditions the influences of temperature, air circulation, air change rate and relative humidity on the emission behavior of the selected biocides and PCBs had to be determined. This was carried out with pre-soaked wood samples in low volume air sampling experiments using 27L test showcases and 23L and 24L emission test chambers and also diffusive sampling with glass as the sampling material.</description><subject>Air Pollutants - analysis</subject><subject>Air sampling</subject><subject>Biocides</subject><subject>Disinfectants - analysis</subject><subject>Emission analysis</subject><subject>Emission test chamber</subject><subject>Environmental Monitoring - methods</subject><subject>Gas Chromatography-Mass Spectrometry</subject><subject>Museums</subject><subject>Polychlorinated biphenyls</subject><subject>Polychlorinated Biphenyls - analysis</subject><subject>Sampling</subject><subject>SDVB-polymer</subject><subject>Showcase</subject><subject>Showcases</subject><subject>SVOC</subject><subject>Tandem Mass Spectrometry</subject><subject>Volatile Organic Compounds - analysis</subject><subject>Wood</subject><issn>0045-6535</issn><issn>1879-1298</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqNkU2P0zAQhi0EYsvCX0DmxiVh7Niuc4RqgZVWYg9wtvwxoa6SuNhJEf8eL10Qx548sp53xp6HkDcMWgZMvTu0fo9TKsc9Zmw5MNGCaoGzJ2TD9LZvGO_1U7IBELJRspNX5EUpB4Aalv1zcsVlrQVjG3J_O5-wLPG7XWKaC00zXfZIcYqlnC8G6mLyMWChdg70fveh0HUOmOmYftJTGtcJqU9ziH86vCTPBjsWfPV4XpNvH2--7j43d18-3e7e3zVeiG5pNLdbJ6zactYxC7qTnHEUw7Zn1gbd-QE5yOCc8OAcgAcvUDt03aAl9Kq7Jm_PfY85_VjrF0x9ssdxtDOmtRimFIBWIC5BpVC647y_AOW91JKDqGh_Rn1OpWQczDHHyeZfhoF50GQO5j9N5kGTAWWqppp9_ThmdROGf8m_XiqwOwNYV3iKmE3xEWePIWb0iwkpXjDmN8UFqOA</recordid><startdate>201501</startdate><enddate>201501</enddate><creator>Mull, Birte</creator><creator>Horn, Wolfgang</creator><creator>Jann, Oliver</creator><general>Elsevier Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>7TV</scope><scope>C1K</scope><scope>7SC</scope><scope>8FD</scope><scope>FR3</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><orcidid>https://orcid.org/0000-0002-4936-9605</orcidid><orcidid>https://orcid.org/0000-0003-3926-4081</orcidid></search><sort><creationdate>201501</creationdate><title>Investigations on the emissions of biocides and PCBs under low volume conditions</title><author>Mull, Birte ; Horn, Wolfgang ; Jann, Oliver</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c443t-82a7b4a672131a0835212e4f791aad83cfe205dbb4c0bb00c0c4e8beb3f850963</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Air Pollutants - analysis</topic><topic>Air sampling</topic><topic>Biocides</topic><topic>Disinfectants - analysis</topic><topic>Emission analysis</topic><topic>Emission test chamber</topic><topic>Environmental Monitoring - methods</topic><topic>Gas Chromatography-Mass Spectrometry</topic><topic>Museums</topic><topic>Polychlorinated biphenyls</topic><topic>Polychlorinated Biphenyls - analysis</topic><topic>Sampling</topic><topic>SDVB-polymer</topic><topic>Showcase</topic><topic>Showcases</topic><topic>SVOC</topic><topic>Tandem Mass Spectrometry</topic><topic>Volatile Organic Compounds - analysis</topic><topic>Wood</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mull, Birte</creatorcontrib><creatorcontrib>Horn, Wolfgang</creatorcontrib><creatorcontrib>Jann, Oliver</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Pollution Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Computer and Information Systems Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><jtitle>Chemosphere (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mull, Birte</au><au>Horn, Wolfgang</au><au>Jann, Oliver</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Investigations on the emissions of biocides and PCBs under low volume conditions</atitle><jtitle>Chemosphere (Oxford)</jtitle><addtitle>Chemosphere</addtitle><date>2015-01</date><risdate>2015</risdate><volume>118</volume><spage>65</spage><epage>71</epage><pages>65-71</pages><issn>0045-6535</issn><eissn>1879-1298</eissn><abstract>•Dynamic conditions are essential for a quantitative SVOC analysis in air-tight showcases.•Diffusive sampling in air-tight showcases allows the detection of more SVOCs than active sampling.•By increasing the air sampling volume the amount of detectable higher boiling SVOCs is increased.•Increasing temperatures decrease the emission time above the corresponding limits of quantification. The aim of this study was the development of a low volume air sampling strategy for biocides and polychlorinated biphenyls (PCB) at low air change rates in modern, air-tight showcases as they are present in museums. Lindane, pentachlorophenol, dichlofluanid, tolyfluanid, isodrin, p,p-dichlorodiphenyl trichloroethane and permethrin were the biocides and PCB28 and PCB153 were the PCBs studied, all of which are semi volatile organic compounds (SVOC). Their occurrences in the museum environment originate from various sources e.g. preventive treatment of organic exhibits or organic building materials. Exhibits are long-term exposed to these pollutants due to storing in showcases or other storage equipment at low air change rates. To achieve air sampling under the aforementioned conditions the influences of temperature, air circulation, air change rate and relative humidity on the emission behavior of the selected biocides and PCBs had to be determined. This was carried out with pre-soaked wood samples in low volume air sampling experiments using 27L test showcases and 23L and 24L emission test chambers and also diffusive sampling with glass as the sampling material.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>25000411</pmid><doi>10.1016/j.chemosphere.2014.06.021</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0002-4936-9605</orcidid><orcidid>https://orcid.org/0000-0003-3926-4081</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0045-6535
ispartof Chemosphere (Oxford), 2015-01, Vol.118, p.65-71
issn 0045-6535
1879-1298
language eng
recordid cdi_proquest_miscellaneous_1660086046
source MEDLINE; ScienceDirect Freedom Collection (Elsevier)
subjects Air Pollutants - analysis
Air sampling
Biocides
Disinfectants - analysis
Emission analysis
Emission test chamber
Environmental Monitoring - methods
Gas Chromatography-Mass Spectrometry
Museums
Polychlorinated biphenyls
Polychlorinated Biphenyls - analysis
Sampling
SDVB-polymer
Showcase
Showcases
SVOC
Tandem Mass Spectrometry
Volatile Organic Compounds - analysis
Wood
title Investigations on the emissions of biocides and PCBs under low volume conditions
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-10T19%3A19%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Investigations%20on%20the%20emissions%20of%20biocides%20and%20PCBs%20under%20low%20volume%20conditions&rft.jtitle=Chemosphere%20(Oxford)&rft.au=Mull,%20Birte&rft.date=2015-01&rft.volume=118&rft.spage=65&rft.epage=71&rft.pages=65-71&rft.issn=0045-6535&rft.eissn=1879-1298&rft_id=info:doi/10.1016/j.chemosphere.2014.06.021&rft_dat=%3Cproquest_cross%3E1654683229%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1629585204&rft_id=info:pmid/25000411&rft_els_id=S0045653514007577&rfr_iscdi=true