Selective droplet sampling using a minimum number of horizontal pneumatic actuators in a high aspect ratio and highly flexible PDMS device

This paper presents a droplet sampling device driven by horizontal pneumatic actuators. A high aspect ratio and highly flexible PDMS (polydimethylsiloxane) structure was proposed for carrying out larger number of sampling than the number of actuators. Large deformation of the actuators caused domino...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:RSC advances 2015-01, Vol.5 (3), p.2070-2074
Hauptverfasser: Yoon, Dong Hyun, Wakui, Daisuke, Nakahara, Asahi, Sekiguchi, Tetsushi, Shoji, Shuichi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2074
container_issue 3
container_start_page 2070
container_title RSC advances
container_volume 5
creator Yoon, Dong Hyun
Wakui, Daisuke
Nakahara, Asahi
Sekiguchi, Tetsushi
Shoji, Shuichi
description This paper presents a droplet sampling device driven by horizontal pneumatic actuators. A high aspect ratio and highly flexible PDMS (polydimethylsiloxane) structure was proposed for carrying out larger number of sampling than the number of actuators. Large deformation of the actuators caused domino-deformation of parallel walls, and the deformations allowed for selective collection of target droplets. The dimensions of the PDMS structure and the ratio of resin to curing agent were optimized for efficient sampling under the low pressure applied to the actuators. Five sampling modes were achieved in the simple one-layer structure consisting of one inlet, four walls, one drain channel, and two pneumatic actuators, formed by single-step soft lithography process.
doi_str_mv 10.1039/C4RA11254G
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1660070018</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1660070018</sourcerecordid><originalsourceid>FETCH-LOGICAL-c330t-3c3765496e870b3592637be04facf94932ae9d00578ee5b0ac685abe42f55983</originalsourceid><addsrcrecordid>eNpNkFFLwzAUhYMoOHQv_oI8ilBNmiZdHsfUKUwUt_eSprdbJG1qkg7nT_BX2zlB78O5l8t3zsNB6IKSa0qYvJllr1NKU57Nj9AoJZlIUiLk8b_7FI1DeCPDCE5TQUfoawkWdDRbwJV3nYWIg2o6a9o17sNeFW5Ma5q-wW3flOCxq_HGefPp2qgs7lroGxWNxkrHXkXnAzbt4NqY9Qar0A3p2A-Aw6qtfr52h2sLH6a0gF9un5a4gq3RcI5OamUDjH_3GVrd361mD8nief44my4SzRiJCdMsFzyTAiY5KRmXqWB5CSSrla5lJlmqQFaE8HwCwEuitJhwVUKW1pzLCTtDl4fYzrv3HkIsGhM0WKtacH0oqBCE5ITQPXp1QLV3IXioi86bRvldQUmxr7z4q5x9AyubdPM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1660070018</pqid></control><display><type>article</type><title>Selective droplet sampling using a minimum number of horizontal pneumatic actuators in a high aspect ratio and highly flexible PDMS device</title><source>Royal Society Of Chemistry Journals 2008-</source><creator>Yoon, Dong Hyun ; Wakui, Daisuke ; Nakahara, Asahi ; Sekiguchi, Tetsushi ; Shoji, Shuichi</creator><creatorcontrib>Yoon, Dong Hyun ; Wakui, Daisuke ; Nakahara, Asahi ; Sekiguchi, Tetsushi ; Shoji, Shuichi</creatorcontrib><description>This paper presents a droplet sampling device driven by horizontal pneumatic actuators. A high aspect ratio and highly flexible PDMS (polydimethylsiloxane) structure was proposed for carrying out larger number of sampling than the number of actuators. Large deformation of the actuators caused domino-deformation of parallel walls, and the deformations allowed for selective collection of target droplets. The dimensions of the PDMS structure and the ratio of resin to curing agent were optimized for efficient sampling under the low pressure applied to the actuators. Five sampling modes were achieved in the simple one-layer structure consisting of one inlet, four walls, one drain channel, and two pneumatic actuators, formed by single-step soft lithography process.</description><identifier>ISSN: 2046-2069</identifier><identifier>EISSN: 2046-2069</identifier><identifier>DOI: 10.1039/C4RA11254G</identifier><language>eng</language><subject>Actuators ; Devices ; Droplets ; Horizontal ; Pneumatics ; Sampling ; Silicone resins ; Walls</subject><ispartof>RSC advances, 2015-01, Vol.5 (3), p.2070-2074</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c330t-3c3765496e870b3592637be04facf94932ae9d00578ee5b0ac685abe42f55983</citedby><cites>FETCH-LOGICAL-c330t-3c3765496e870b3592637be04facf94932ae9d00578ee5b0ac685abe42f55983</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Yoon, Dong Hyun</creatorcontrib><creatorcontrib>Wakui, Daisuke</creatorcontrib><creatorcontrib>Nakahara, Asahi</creatorcontrib><creatorcontrib>Sekiguchi, Tetsushi</creatorcontrib><creatorcontrib>Shoji, Shuichi</creatorcontrib><title>Selective droplet sampling using a minimum number of horizontal pneumatic actuators in a high aspect ratio and highly flexible PDMS device</title><title>RSC advances</title><description>This paper presents a droplet sampling device driven by horizontal pneumatic actuators. A high aspect ratio and highly flexible PDMS (polydimethylsiloxane) structure was proposed for carrying out larger number of sampling than the number of actuators. Large deformation of the actuators caused domino-deformation of parallel walls, and the deformations allowed for selective collection of target droplets. The dimensions of the PDMS structure and the ratio of resin to curing agent were optimized for efficient sampling under the low pressure applied to the actuators. Five sampling modes were achieved in the simple one-layer structure consisting of one inlet, four walls, one drain channel, and two pneumatic actuators, formed by single-step soft lithography process.</description><subject>Actuators</subject><subject>Devices</subject><subject>Droplets</subject><subject>Horizontal</subject><subject>Pneumatics</subject><subject>Sampling</subject><subject>Silicone resins</subject><subject>Walls</subject><issn>2046-2069</issn><issn>2046-2069</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNpNkFFLwzAUhYMoOHQv_oI8ilBNmiZdHsfUKUwUt_eSprdbJG1qkg7nT_BX2zlB78O5l8t3zsNB6IKSa0qYvJllr1NKU57Nj9AoJZlIUiLk8b_7FI1DeCPDCE5TQUfoawkWdDRbwJV3nYWIg2o6a9o17sNeFW5Ma5q-wW3flOCxq_HGefPp2qgs7lroGxWNxkrHXkXnAzbt4NqY9Qar0A3p2A-Aw6qtfr52h2sLH6a0gF9un5a4gq3RcI5OamUDjH_3GVrd361mD8nief44my4SzRiJCdMsFzyTAiY5KRmXqWB5CSSrla5lJlmqQFaE8HwCwEuitJhwVUKW1pzLCTtDl4fYzrv3HkIsGhM0WKtacH0oqBCE5ITQPXp1QLV3IXioi86bRvldQUmxr7z4q5x9AyubdPM</recordid><startdate>20150101</startdate><enddate>20150101</enddate><creator>Yoon, Dong Hyun</creator><creator>Wakui, Daisuke</creator><creator>Nakahara, Asahi</creator><creator>Sekiguchi, Tetsushi</creator><creator>Shoji, Shuichi</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7SR</scope><scope>7TB</scope><scope>8BQ</scope><scope>8FD</scope><scope>FR3</scope><scope>JG9</scope><scope>L7M</scope></search><sort><creationdate>20150101</creationdate><title>Selective droplet sampling using a minimum number of horizontal pneumatic actuators in a high aspect ratio and highly flexible PDMS device</title><author>Yoon, Dong Hyun ; Wakui, Daisuke ; Nakahara, Asahi ; Sekiguchi, Tetsushi ; Shoji, Shuichi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c330t-3c3765496e870b3592637be04facf94932ae9d00578ee5b0ac685abe42f55983</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Actuators</topic><topic>Devices</topic><topic>Droplets</topic><topic>Horizontal</topic><topic>Pneumatics</topic><topic>Sampling</topic><topic>Silicone resins</topic><topic>Walls</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yoon, Dong Hyun</creatorcontrib><creatorcontrib>Wakui, Daisuke</creatorcontrib><creatorcontrib>Nakahara, Asahi</creatorcontrib><creatorcontrib>Sekiguchi, Tetsushi</creatorcontrib><creatorcontrib>Shoji, Shuichi</creatorcontrib><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>RSC advances</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yoon, Dong Hyun</au><au>Wakui, Daisuke</au><au>Nakahara, Asahi</au><au>Sekiguchi, Tetsushi</au><au>Shoji, Shuichi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Selective droplet sampling using a minimum number of horizontal pneumatic actuators in a high aspect ratio and highly flexible PDMS device</atitle><jtitle>RSC advances</jtitle><date>2015-01-01</date><risdate>2015</risdate><volume>5</volume><issue>3</issue><spage>2070</spage><epage>2074</epage><pages>2070-2074</pages><issn>2046-2069</issn><eissn>2046-2069</eissn><abstract>This paper presents a droplet sampling device driven by horizontal pneumatic actuators. A high aspect ratio and highly flexible PDMS (polydimethylsiloxane) structure was proposed for carrying out larger number of sampling than the number of actuators. Large deformation of the actuators caused domino-deformation of parallel walls, and the deformations allowed for selective collection of target droplets. The dimensions of the PDMS structure and the ratio of resin to curing agent were optimized for efficient sampling under the low pressure applied to the actuators. Five sampling modes were achieved in the simple one-layer structure consisting of one inlet, four walls, one drain channel, and two pneumatic actuators, formed by single-step soft lithography process.</abstract><doi>10.1039/C4RA11254G</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 2046-2069
ispartof RSC advances, 2015-01, Vol.5 (3), p.2070-2074
issn 2046-2069
2046-2069
language eng
recordid cdi_proquest_miscellaneous_1660070018
source Royal Society Of Chemistry Journals 2008-
subjects Actuators
Devices
Droplets
Horizontal
Pneumatics
Sampling
Silicone resins
Walls
title Selective droplet sampling using a minimum number of horizontal pneumatic actuators in a high aspect ratio and highly flexible PDMS device
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T07%3A42%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Selective%20droplet%20sampling%20using%20a%20minimum%20number%20of%20horizontal%20pneumatic%20actuators%20in%20a%20high%20aspect%20ratio%20and%20highly%20flexible%20PDMS%20device&rft.jtitle=RSC%20advances&rft.au=Yoon,%20Dong%20Hyun&rft.date=2015-01-01&rft.volume=5&rft.issue=3&rft.spage=2070&rft.epage=2074&rft.pages=2070-2074&rft.issn=2046-2069&rft.eissn=2046-2069&rft_id=info:doi/10.1039/C4RA11254G&rft_dat=%3Cproquest_cross%3E1660070018%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1660070018&rft_id=info:pmid/&rfr_iscdi=true