Balloon aortic valvuloplasty as a bridge to aortic valve surgery for severe aortic stenosis
A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was, in patients with severe aortic stenosis, can balloon valvuloplasty be used as a bridge to aortic valve replacement? Altogether 463 papers were found using the reported search, of whic...
Gespeichert in:
Veröffentlicht in: | Interactive cardiovascular and thoracic surgery 2015-03, Vol.20 (3), p.429-435 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 435 |
---|---|
container_issue | 3 |
container_start_page | 429 |
container_title | Interactive cardiovascular and thoracic surgery |
container_volume | 20 |
creator | Nwaejike, Nnamdi Mills, Keith Stables, Rod Field, Mark |
description | A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was, in patients with severe aortic stenosis, can balloon valvuloplasty be used as a bridge to aortic valve replacement? Altogether 463 papers were found using the reported search, of which 11 papers represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. We conclude that balloon aortic valvuloplasty is recommended as a bridge to aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI) in patients with severe symptomatic aortic stenosis. Institutional practices, local and logistic factors can affect patient selection and management approaches to severe aortic stenosis, but having the facility to offer balloon aortic valvuloplasty (especially in the TAVI era) provides another management option for patients who would otherwise have been considered unacceptably high risk for aortic valve surgery. The increased incidence of balloon aortic valvuloplasty mirrors the increase in the use of TAVI with a sharp increase in activity from 2006. Success rates for bridging from balloon aortic valvuloplasty to definite surgical intervention are in the range 26.3–74%, with AVR or TAVI occurring within 8 weeks to 7 months. Complications from balloon aortic valvuloplasty such as aortic regurgitation (AR) can be managed successfully. Up to 40% of patients selected by balloon aortic valvuloplasty to have TAVI or AVR do not have these procedures within 2 years. While most of these patients are excluded for objective clinical reasons such as terminal disease/malignancy or other persistent contraindication, some patients refuse definitive treatment and others die while on the waiting list. Outcomes in patients bridged to AVR/TAVI are better than in patients treated with balloon aortic valvuloplasty only. Owing to the high mortality of patients in this cohort without destination therapy, delays to progression to TAVI or AVR should be avoided in selected patients. A discussion with the patient about expectations, mortality and morbidity risks with all management options will aid decision-making. |
doi_str_mv | 10.1093/icvts/ivu398 |
format | Article |
fullrecord | <record><control><sourceid>proquest_TOX</sourceid><recordid>TN_cdi_proquest_miscellaneous_1655522060</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><oup_id>10.1093/icvts/ivu398</oup_id><sourcerecordid>1655522060</sourcerecordid><originalsourceid>FETCH-LOGICAL-c427t-4e1607b19d79c29d649ed272af02f24f164f5c987f373b1295bfed4d6ada870b3</originalsourceid><addsrcrecordid>eNp90DtPwzAUhmELgWgpbMzIGwyE-hLH8QgVN6kSC0wMkRMfV0FpXXySSP33FFIqJiYfyY--4SXknLMbzoyc1lXf4rTuO2nyAzLmKjOJEbk63N9GjsgJ4gdj3DDJjslIqDTXQvIxeb-zTRPCitoQ27qivW36rgnrxmK7oRappWWs3QJoG_4aoNjFBcQN9SFShB4i_P5jC6uANZ6SI28bhLPdOyFvD_evs6dk_vL4PLudJ1UqdJukwDOmS26cNpUwLksNOKGF9Ux4kXqepV5VJtdeallyYVTpwaUus87mmpVyQq6G3XUMnx1gWyxrrKBp7ApChwXPlFJCsIxt6fVAqxgQI_hiHeuljZuCs-I7Z_GTsxhybvnFbrkrl-D2-LffFlwOIHTr_6e-AKtMgXk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1655522060</pqid></control><display><type>article</type><title>Balloon aortic valvuloplasty as a bridge to aortic valve surgery for severe aortic stenosis</title><source>Oxford Journals Open Access Collection</source><creator>Nwaejike, Nnamdi ; Mills, Keith ; Stables, Rod ; Field, Mark</creator><creatorcontrib>Nwaejike, Nnamdi ; Mills, Keith ; Stables, Rod ; Field, Mark</creatorcontrib><description>A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was, in patients with severe aortic stenosis, can balloon valvuloplasty be used as a bridge to aortic valve replacement? Altogether 463 papers were found using the reported search, of which 11 papers represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. We conclude that balloon aortic valvuloplasty is recommended as a bridge to aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI) in patients with severe symptomatic aortic stenosis. Institutional practices, local and logistic factors can affect patient selection and management approaches to severe aortic stenosis, but having the facility to offer balloon aortic valvuloplasty (especially in the TAVI era) provides another management option for patients who would otherwise have been considered unacceptably high risk for aortic valve surgery. The increased incidence of balloon aortic valvuloplasty mirrors the increase in the use of TAVI with a sharp increase in activity from 2006. Success rates for bridging from balloon aortic valvuloplasty to definite surgical intervention are in the range 26.3–74%, with AVR or TAVI occurring within 8 weeks to 7 months. Complications from balloon aortic valvuloplasty such as aortic regurgitation (AR) can be managed successfully. Up to 40% of patients selected by balloon aortic valvuloplasty to have TAVI or AVR do not have these procedures within 2 years. While most of these patients are excluded for objective clinical reasons such as terminal disease/malignancy or other persistent contraindication, some patients refuse definitive treatment and others die while on the waiting list. Outcomes in patients bridged to AVR/TAVI are better than in patients treated with balloon aortic valvuloplasty only. Owing to the high mortality of patients in this cohort without destination therapy, delays to progression to TAVI or AVR should be avoided in selected patients. A discussion with the patient about expectations, mortality and morbidity risks with all management options will aid decision-making.</description><identifier>ISSN: 1569-9293</identifier><identifier>EISSN: 1569-9285</identifier><identifier>DOI: 10.1093/icvts/ivu398</identifier><identifier>PMID: 25487231</identifier><language>eng</language><publisher>England: Oxford University Press</publisher><subject>Aortic Valve Stenosis - diagnosis ; Aortic Valve Stenosis - surgery ; Balloon Valvuloplasty - methods ; Heart Valve Prosthesis ; Humans ; Severity of Illness Index</subject><ispartof>Interactive cardiovascular and thoracic surgery, 2015-03, Vol.20 (3), p.429-435</ispartof><rights>The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved. 2014</rights><rights>The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c427t-4e1607b19d79c29d649ed272af02f24f164f5c987f373b1295bfed4d6ada870b3</citedby><cites>FETCH-LOGICAL-c427t-4e1607b19d79c29d649ed272af02f24f164f5c987f373b1295bfed4d6ada870b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,1604,27924,27925</link.rule.ids><linktorsrc>$$Uhttps://dx.doi.org/10.1093/icvts/ivu398$$EView_record_in_Oxford_University_Press$$FView_record_in_$$GOxford_University_Press</linktorsrc><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25487231$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Nwaejike, Nnamdi</creatorcontrib><creatorcontrib>Mills, Keith</creatorcontrib><creatorcontrib>Stables, Rod</creatorcontrib><creatorcontrib>Field, Mark</creatorcontrib><title>Balloon aortic valvuloplasty as a bridge to aortic valve surgery for severe aortic stenosis</title><title>Interactive cardiovascular and thoracic surgery</title><addtitle>Interact Cardiovasc Thorac Surg</addtitle><description>A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was, in patients with severe aortic stenosis, can balloon valvuloplasty be used as a bridge to aortic valve replacement? Altogether 463 papers were found using the reported search, of which 11 papers represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. We conclude that balloon aortic valvuloplasty is recommended as a bridge to aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI) in patients with severe symptomatic aortic stenosis. Institutional practices, local and logistic factors can affect patient selection and management approaches to severe aortic stenosis, but having the facility to offer balloon aortic valvuloplasty (especially in the TAVI era) provides another management option for patients who would otherwise have been considered unacceptably high risk for aortic valve surgery. The increased incidence of balloon aortic valvuloplasty mirrors the increase in the use of TAVI with a sharp increase in activity from 2006. Success rates for bridging from balloon aortic valvuloplasty to definite surgical intervention are in the range 26.3–74%, with AVR or TAVI occurring within 8 weeks to 7 months. Complications from balloon aortic valvuloplasty such as aortic regurgitation (AR) can be managed successfully. Up to 40% of patients selected by balloon aortic valvuloplasty to have TAVI or AVR do not have these procedures within 2 years. While most of these patients are excluded for objective clinical reasons such as terminal disease/malignancy or other persistent contraindication, some patients refuse definitive treatment and others die while on the waiting list. Outcomes in patients bridged to AVR/TAVI are better than in patients treated with balloon aortic valvuloplasty only. Owing to the high mortality of patients in this cohort without destination therapy, delays to progression to TAVI or AVR should be avoided in selected patients. A discussion with the patient about expectations, mortality and morbidity risks with all management options will aid decision-making.</description><subject>Aortic Valve Stenosis - diagnosis</subject><subject>Aortic Valve Stenosis - surgery</subject><subject>Balloon Valvuloplasty - methods</subject><subject>Heart Valve Prosthesis</subject><subject>Humans</subject><subject>Severity of Illness Index</subject><issn>1569-9293</issn><issn>1569-9285</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp90DtPwzAUhmELgWgpbMzIGwyE-hLH8QgVN6kSC0wMkRMfV0FpXXySSP33FFIqJiYfyY--4SXknLMbzoyc1lXf4rTuO2nyAzLmKjOJEbk63N9GjsgJ4gdj3DDJjslIqDTXQvIxeb-zTRPCitoQ27qivW36rgnrxmK7oRappWWs3QJoG_4aoNjFBcQN9SFShB4i_P5jC6uANZ6SI28bhLPdOyFvD_evs6dk_vL4PLudJ1UqdJukwDOmS26cNpUwLksNOKGF9Ux4kXqepV5VJtdeallyYVTpwaUus87mmpVyQq6G3XUMnx1gWyxrrKBp7ApChwXPlFJCsIxt6fVAqxgQI_hiHeuljZuCs-I7Z_GTsxhybvnFbrkrl-D2-LffFlwOIHTr_6e-AKtMgXk</recordid><startdate>20150301</startdate><enddate>20150301</enddate><creator>Nwaejike, Nnamdi</creator><creator>Mills, Keith</creator><creator>Stables, Rod</creator><creator>Field, Mark</creator><general>Oxford University Press</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20150301</creationdate><title>Balloon aortic valvuloplasty as a bridge to aortic valve surgery for severe aortic stenosis</title><author>Nwaejike, Nnamdi ; Mills, Keith ; Stables, Rod ; Field, Mark</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c427t-4e1607b19d79c29d649ed272af02f24f164f5c987f373b1295bfed4d6ada870b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Aortic Valve Stenosis - diagnosis</topic><topic>Aortic Valve Stenosis - surgery</topic><topic>Balloon Valvuloplasty - methods</topic><topic>Heart Valve Prosthesis</topic><topic>Humans</topic><topic>Severity of Illness Index</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Nwaejike, Nnamdi</creatorcontrib><creatorcontrib>Mills, Keith</creatorcontrib><creatorcontrib>Stables, Rod</creatorcontrib><creatorcontrib>Field, Mark</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Interactive cardiovascular and thoracic surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Nwaejike, Nnamdi</au><au>Mills, Keith</au><au>Stables, Rod</au><au>Field, Mark</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Balloon aortic valvuloplasty as a bridge to aortic valve surgery for severe aortic stenosis</atitle><jtitle>Interactive cardiovascular and thoracic surgery</jtitle><addtitle>Interact Cardiovasc Thorac Surg</addtitle><date>2015-03-01</date><risdate>2015</risdate><volume>20</volume><issue>3</issue><spage>429</spage><epage>435</epage><pages>429-435</pages><issn>1569-9293</issn><eissn>1569-9285</eissn><abstract>A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was, in patients with severe aortic stenosis, can balloon valvuloplasty be used as a bridge to aortic valve replacement? Altogether 463 papers were found using the reported search, of which 11 papers represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. We conclude that balloon aortic valvuloplasty is recommended as a bridge to aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI) in patients with severe symptomatic aortic stenosis. Institutional practices, local and logistic factors can affect patient selection and management approaches to severe aortic stenosis, but having the facility to offer balloon aortic valvuloplasty (especially in the TAVI era) provides another management option for patients who would otherwise have been considered unacceptably high risk for aortic valve surgery. The increased incidence of balloon aortic valvuloplasty mirrors the increase in the use of TAVI with a sharp increase in activity from 2006. Success rates for bridging from balloon aortic valvuloplasty to definite surgical intervention are in the range 26.3–74%, with AVR or TAVI occurring within 8 weeks to 7 months. Complications from balloon aortic valvuloplasty such as aortic regurgitation (AR) can be managed successfully. Up to 40% of patients selected by balloon aortic valvuloplasty to have TAVI or AVR do not have these procedures within 2 years. While most of these patients are excluded for objective clinical reasons such as terminal disease/malignancy or other persistent contraindication, some patients refuse definitive treatment and others die while on the waiting list. Outcomes in patients bridged to AVR/TAVI are better than in patients treated with balloon aortic valvuloplasty only. Owing to the high mortality of patients in this cohort without destination therapy, delays to progression to TAVI or AVR should be avoided in selected patients. A discussion with the patient about expectations, mortality and morbidity risks with all management options will aid decision-making.</abstract><cop>England</cop><pub>Oxford University Press</pub><pmid>25487231</pmid><doi>10.1093/icvts/ivu398</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 1569-9293 |
ispartof | Interactive cardiovascular and thoracic surgery, 2015-03, Vol.20 (3), p.429-435 |
issn | 1569-9293 1569-9285 |
language | eng |
recordid | cdi_proquest_miscellaneous_1655522060 |
source | Oxford Journals Open Access Collection |
subjects | Aortic Valve Stenosis - diagnosis Aortic Valve Stenosis - surgery Balloon Valvuloplasty - methods Heart Valve Prosthesis Humans Severity of Illness Index |
title | Balloon aortic valvuloplasty as a bridge to aortic valve surgery for severe aortic stenosis |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T17%3A34%3A15IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_TOX&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Balloon%20aortic%20valvuloplasty%20as%20a%20bridge%20to%20aortic%20valve%20surgery%20for%20severe%20aortic%20stenosis&rft.jtitle=Interactive%20cardiovascular%20and%20thoracic%20surgery&rft.au=Nwaejike,%20Nnamdi&rft.date=2015-03-01&rft.volume=20&rft.issue=3&rft.spage=429&rft.epage=435&rft.pages=429-435&rft.issn=1569-9293&rft.eissn=1569-9285&rft_id=info:doi/10.1093/icvts/ivu398&rft_dat=%3Cproquest_TOX%3E1655522060%3C/proquest_TOX%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1655522060&rft_id=info:pmid/25487231&rft_oup_id=10.1093/icvts/ivu398&rfr_iscdi=true |