Practical Aspects of Volume Control in Chronic Kidney Disease Using Whole Body Bioimpedance

Background: Fluid status is an independent predictor of mortality in dialysis patients. Current methods of fluid assessment have several limitations. Summary: An ideal method should be cheap, portable, easy to perform without extensive training, reproducible and determines patients' excess or d...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Blood purification 2015-01, Vol.39 (1-3), p.32-36
Hauptverfasser: Oei, Elizabeth L., Fan, Stanley L.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 36
container_issue 1-3
container_start_page 32
container_title Blood purification
container_volume 39
creator Oei, Elizabeth L.
Fan, Stanley L.
description Background: Fluid status is an independent predictor of mortality in dialysis patients. Current methods of fluid assessment have several limitations. Summary: An ideal method should be cheap, portable, easy to perform without extensive training, reproducible and determines patients' excess or deficit of total body water. Bioimpedance analysis (BIA) fulfils many of these criteria and can give additional information on fat and lean tissue composition. The accuracy and precision of BIA has been shown to be equivalent to the ‘gold standard' direct estimation techniques. Key Messages: Although there remains some concern about its validity in dialysis patients, fluid overload determined by BIA has been shown to predict mortality. BIA-guided fluid management appears superior to conventional fluid management in achieving clinically important outcomes such as reduction in blood pressure, left ventricular mass index, and arterial stiffness. Accurate setting of dry weight might also help preserve residual renal function by limiting episodes of dehydration. Nevertheless, as with all new technologies, there are issues that still need to be resolved. This will be achieved only with larger prospective interventional studies to explore its specific roles in dialysis cohorts.
doi_str_mv 10.1159/000368953
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1653129993</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1653129993</sourcerecordid><originalsourceid>FETCH-LOGICAL-c407t-3b262b9465b0e970ad21a6010dd80c9473657baf25d7645667d8c69957e01eb43</originalsourceid><addsrcrecordid>eNo90L1PwzAQBXALgWgpDOwIeYQhcI5jpx5p-RSVYKAwMESOfW0NSVzsdOh_T1BLp1t-9_T0CDllcMWYUNcAwOVQCb5H-ixLWaJyLvZJH1LBEwFy2CNHMX4BsEwKdUh6qZASMiX75PM1aNM6oyt6E5do2kj9jL77alUjHfumDb6irqHjRfCNM_TZ2QbX9NZF1BHpNLpmTj8WvkI68nZNR867eolWNwaPycFMVxFPtndApvd3b-PHZPLy8DS-mSQmg7xNeJnKtFRdtRJQ5aBtyrQEBtYOwags51LkpZ6lwuYy65rndmikUiJHYFhmfEAuNrnL4H9WGNuidtFgVekG_SoWTArOUqUU7-jlhprgYww4K5bB1TqsCwbF35bFbsvOnm9jV2WNdif_x-vA2QZ86zDHsAPb_1_p9nXl</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1653129993</pqid></control><display><type>article</type><title>Practical Aspects of Volume Control in Chronic Kidney Disease Using Whole Body Bioimpedance</title><source>MEDLINE</source><source>Karger Journals</source><creator>Oei, Elizabeth L. ; Fan, Stanley L.</creator><creatorcontrib>Oei, Elizabeth L. ; Fan, Stanley L.</creatorcontrib><description>Background: Fluid status is an independent predictor of mortality in dialysis patients. Current methods of fluid assessment have several limitations. Summary: An ideal method should be cheap, portable, easy to perform without extensive training, reproducible and determines patients' excess or deficit of total body water. Bioimpedance analysis (BIA) fulfils many of these criteria and can give additional information on fat and lean tissue composition. The accuracy and precision of BIA has been shown to be equivalent to the ‘gold standard' direct estimation techniques. Key Messages: Although there remains some concern about its validity in dialysis patients, fluid overload determined by BIA has been shown to predict mortality. BIA-guided fluid management appears superior to conventional fluid management in achieving clinically important outcomes such as reduction in blood pressure, left ventricular mass index, and arterial stiffness. Accurate setting of dry weight might also help preserve residual renal function by limiting episodes of dehydration. Nevertheless, as with all new technologies, there are issues that still need to be resolved. This will be achieved only with larger prospective interventional studies to explore its specific roles in dialysis cohorts.</description><identifier>ISSN: 0253-5068</identifier><identifier>EISSN: 1421-9735</identifier><identifier>DOI: 10.1159/000368953</identifier><identifier>PMID: 25660496</identifier><language>eng</language><publisher>Basel, Switzerland</publisher><subject>Blood Pressure ; Body Composition ; Body Fluids ; Body Water - metabolism ; Body Weight ; Electric Impedance ; Heart Ventricles - metabolism ; Heart Ventricles - physiopathology ; Humans ; Kidney Failure, Chronic - metabolism ; Kidney Failure, Chronic - mortality ; Kidney Failure, Chronic - pathology ; Kidney Failure, Chronic - therapy ; Monitoring, Physiologic - instrumentation ; Original Paper ; Renal Dialysis ; Survival Analysis ; Vascular Stiffness</subject><ispartof>Blood purification, 2015-01, Vol.39 (1-3), p.32-36</ispartof><rights>2015 S. Karger AG, Basel</rights><rights>2015 S. Karger AG, Basel.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c407t-3b262b9465b0e970ad21a6010dd80c9473657baf25d7645667d8c69957e01eb43</citedby><cites>FETCH-LOGICAL-c407t-3b262b9465b0e970ad21a6010dd80c9473657baf25d7645667d8c69957e01eb43</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,2427,27923,27924</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25660496$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Oei, Elizabeth L.</creatorcontrib><creatorcontrib>Fan, Stanley L.</creatorcontrib><title>Practical Aspects of Volume Control in Chronic Kidney Disease Using Whole Body Bioimpedance</title><title>Blood purification</title><addtitle>Blood Purif</addtitle><description>Background: Fluid status is an independent predictor of mortality in dialysis patients. Current methods of fluid assessment have several limitations. Summary: An ideal method should be cheap, portable, easy to perform without extensive training, reproducible and determines patients' excess or deficit of total body water. Bioimpedance analysis (BIA) fulfils many of these criteria and can give additional information on fat and lean tissue composition. The accuracy and precision of BIA has been shown to be equivalent to the ‘gold standard' direct estimation techniques. Key Messages: Although there remains some concern about its validity in dialysis patients, fluid overload determined by BIA has been shown to predict mortality. BIA-guided fluid management appears superior to conventional fluid management in achieving clinically important outcomes such as reduction in blood pressure, left ventricular mass index, and arterial stiffness. Accurate setting of dry weight might also help preserve residual renal function by limiting episodes of dehydration. Nevertheless, as with all new technologies, there are issues that still need to be resolved. This will be achieved only with larger prospective interventional studies to explore its specific roles in dialysis cohorts.</description><subject>Blood Pressure</subject><subject>Body Composition</subject><subject>Body Fluids</subject><subject>Body Water - metabolism</subject><subject>Body Weight</subject><subject>Electric Impedance</subject><subject>Heart Ventricles - metabolism</subject><subject>Heart Ventricles - physiopathology</subject><subject>Humans</subject><subject>Kidney Failure, Chronic - metabolism</subject><subject>Kidney Failure, Chronic - mortality</subject><subject>Kidney Failure, Chronic - pathology</subject><subject>Kidney Failure, Chronic - therapy</subject><subject>Monitoring, Physiologic - instrumentation</subject><subject>Original Paper</subject><subject>Renal Dialysis</subject><subject>Survival Analysis</subject><subject>Vascular Stiffness</subject><issn>0253-5068</issn><issn>1421-9735</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo90L1PwzAQBXALgWgpDOwIeYQhcI5jpx5p-RSVYKAwMESOfW0NSVzsdOh_T1BLp1t-9_T0CDllcMWYUNcAwOVQCb5H-ixLWaJyLvZJH1LBEwFy2CNHMX4BsEwKdUh6qZASMiX75PM1aNM6oyt6E5do2kj9jL77alUjHfumDb6irqHjRfCNM_TZ2QbX9NZF1BHpNLpmTj8WvkI68nZNR867eolWNwaPycFMVxFPtndApvd3b-PHZPLy8DS-mSQmg7xNeJnKtFRdtRJQ5aBtyrQEBtYOwags51LkpZ6lwuYy65rndmikUiJHYFhmfEAuNrnL4H9WGNuidtFgVekG_SoWTArOUqUU7-jlhprgYww4K5bB1TqsCwbF35bFbsvOnm9jV2WNdif_x-vA2QZ86zDHsAPb_1_p9nXl</recordid><startdate>20150101</startdate><enddate>20150101</enddate><creator>Oei, Elizabeth L.</creator><creator>Fan, Stanley L.</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20150101</creationdate><title>Practical Aspects of Volume Control in Chronic Kidney Disease Using Whole Body Bioimpedance</title><author>Oei, Elizabeth L. ; Fan, Stanley L.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c407t-3b262b9465b0e970ad21a6010dd80c9473657baf25d7645667d8c69957e01eb43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Blood Pressure</topic><topic>Body Composition</topic><topic>Body Fluids</topic><topic>Body Water - metabolism</topic><topic>Body Weight</topic><topic>Electric Impedance</topic><topic>Heart Ventricles - metabolism</topic><topic>Heart Ventricles - physiopathology</topic><topic>Humans</topic><topic>Kidney Failure, Chronic - metabolism</topic><topic>Kidney Failure, Chronic - mortality</topic><topic>Kidney Failure, Chronic - pathology</topic><topic>Kidney Failure, Chronic - therapy</topic><topic>Monitoring, Physiologic - instrumentation</topic><topic>Original Paper</topic><topic>Renal Dialysis</topic><topic>Survival Analysis</topic><topic>Vascular Stiffness</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Oei, Elizabeth L.</creatorcontrib><creatorcontrib>Fan, Stanley L.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Blood purification</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Oei, Elizabeth L.</au><au>Fan, Stanley L.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Practical Aspects of Volume Control in Chronic Kidney Disease Using Whole Body Bioimpedance</atitle><jtitle>Blood purification</jtitle><addtitle>Blood Purif</addtitle><date>2015-01-01</date><risdate>2015</risdate><volume>39</volume><issue>1-3</issue><spage>32</spage><epage>36</epage><pages>32-36</pages><issn>0253-5068</issn><eissn>1421-9735</eissn><abstract>Background: Fluid status is an independent predictor of mortality in dialysis patients. Current methods of fluid assessment have several limitations. Summary: An ideal method should be cheap, portable, easy to perform without extensive training, reproducible and determines patients' excess or deficit of total body water. Bioimpedance analysis (BIA) fulfils many of these criteria and can give additional information on fat and lean tissue composition. The accuracy and precision of BIA has been shown to be equivalent to the ‘gold standard' direct estimation techniques. Key Messages: Although there remains some concern about its validity in dialysis patients, fluid overload determined by BIA has been shown to predict mortality. BIA-guided fluid management appears superior to conventional fluid management in achieving clinically important outcomes such as reduction in blood pressure, left ventricular mass index, and arterial stiffness. Accurate setting of dry weight might also help preserve residual renal function by limiting episodes of dehydration. Nevertheless, as with all new technologies, there are issues that still need to be resolved. This will be achieved only with larger prospective interventional studies to explore its specific roles in dialysis cohorts.</abstract><cop>Basel, Switzerland</cop><pmid>25660496</pmid><doi>10.1159/000368953</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0253-5068
ispartof Blood purification, 2015-01, Vol.39 (1-3), p.32-36
issn 0253-5068
1421-9735
language eng
recordid cdi_proquest_miscellaneous_1653129993
source MEDLINE; Karger Journals
subjects Blood Pressure
Body Composition
Body Fluids
Body Water - metabolism
Body Weight
Electric Impedance
Heart Ventricles - metabolism
Heart Ventricles - physiopathology
Humans
Kidney Failure, Chronic - metabolism
Kidney Failure, Chronic - mortality
Kidney Failure, Chronic - pathology
Kidney Failure, Chronic - therapy
Monitoring, Physiologic - instrumentation
Original Paper
Renal Dialysis
Survival Analysis
Vascular Stiffness
title Practical Aspects of Volume Control in Chronic Kidney Disease Using Whole Body Bioimpedance
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-12T05%3A49%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Practical%20Aspects%20of%20Volume%20Control%20in%20Chronic%20Kidney%20Disease%20Using%20Whole%20Body%20Bioimpedance&rft.jtitle=Blood%20purification&rft.au=Oei,%20Elizabeth%20L.&rft.date=2015-01-01&rft.volume=39&rft.issue=1-3&rft.spage=32&rft.epage=36&rft.pages=32-36&rft.issn=0253-5068&rft.eissn=1421-9735&rft_id=info:doi/10.1159/000368953&rft_dat=%3Cproquest_cross%3E1653129993%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1653129993&rft_id=info:pmid/25660496&rfr_iscdi=true