TREATABILITY OF WASTEWATERS ORIGINATING FROM WATER-BASED PAINT PRODUCTION WITH LATEX BINDER
In the present study, the treatability of wastewaters originating from water-based paint production with latex binders was investigated. The results of characterization study indicated that the wastewaters can exhibit variable characters during the production depending on washing period, and their C...
Gespeichert in:
Veröffentlicht in: | Fresenius environmental bulletin 2012-01, Vol.21 (10a), p.3122-3126 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 3126 |
---|---|
container_issue | 10a |
container_start_page | 3122 |
container_title | Fresenius environmental bulletin |
container_volume | 21 |
creator | Kabdasli, I Tuenay, O Konuk, K Etcioglu, G Kocabas, E |
description | In the present study, the treatability of wastewaters originating from water-based paint production with latex binders was investigated. The results of characterization study indicated that the wastewaters can exhibit variable characters during the production depending on washing period, and their COD contents varied between 2800 and 15,990 mg/L. Coagulation-flocculation and acid cracking processes were tested as pretreatment applications for both diluted and high strength wastewaters. Acid cracking process proved to be a quite efficient method providing over 95% COD removal, even for the high strength wastewaters. While pretreatment is adequate for direct discharge of the diluted wastewater, high strength needs a further treatment. In the present study, non-biological methods were tested for COD reduction in pretreated high strength wastewaters to fulfill discharge standard. Chemical oxidation using Fenton's reagent proved to be a reliable treatment method for this purpose. Direct oxidation using H sub(2)O sub(2), although requiring long retention times, was also found to be a feasible alternative. |
format | Article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_1651380438</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1651380438</sourcerecordid><originalsourceid>FETCH-LOGICAL-p221t-f9af6d442c63e5e42c241e8f235bb6980fa0315ff3e16b414238c10ef10906203</originalsourceid><addsrcrecordid>eNqFj89LwzAAhXNQcMz9Dzl6KeRXs_SYtukW6JqRZlTxMNqagFLdNNv_b1HvvssHj48H7wYsMMIiYRxnd2AV4xuaw8macLoAz84q6WSua-2eoKlgJ1unOumUbaGxeqMb6XSzgZU1O_jTJ7lsVQn3UjcO7q0pD4XTpoGddltYz8YjzHVTKnsPbkM_Rb_64xIcKuWKbVKbjS5knZwJwZckZH3gL4yRkVOf-pmEYS8Coekw8Eyg0COK0xCox3xgmBEqRox8wCibfyC6BA-_u-ev0-fVx8vx_TWOfpr6D3-6xiPmKaYCMSr-V4mgnIn1rH4DG29VVw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1283648738</pqid></control><display><type>article</type><title>TREATABILITY OF WASTEWATERS ORIGINATING FROM WATER-BASED PAINT PRODUCTION WITH LATEX BINDER</title><source>EZB-FREE-00999 freely available EZB journals</source><creator>Kabdasli, I ; Tuenay, O ; Konuk, K ; Etcioglu, G ; Kocabas, E</creator><creatorcontrib>Kabdasli, I ; Tuenay, O ; Konuk, K ; Etcioglu, G ; Kocabas, E</creatorcontrib><description>In the present study, the treatability of wastewaters originating from water-based paint production with latex binders was investigated. The results of characterization study indicated that the wastewaters can exhibit variable characters during the production depending on washing period, and their COD contents varied between 2800 and 15,990 mg/L. Coagulation-flocculation and acid cracking processes were tested as pretreatment applications for both diluted and high strength wastewaters. Acid cracking process proved to be a quite efficient method providing over 95% COD removal, even for the high strength wastewaters. While pretreatment is adequate for direct discharge of the diluted wastewater, high strength needs a further treatment. In the present study, non-biological methods were tested for COD reduction in pretreated high strength wastewaters to fulfill discharge standard. Chemical oxidation using Fenton's reagent proved to be a reliable treatment method for this purpose. Direct oxidation using H sub(2)O sub(2), although requiring long retention times, was also found to be a feasible alternative.</description><identifier>ISSN: 1018-4619</identifier><language>eng</language><subject>Binders ; Crack opening displacement ; Cracking process ; Discharge ; High strength ; Oxidation ; Waste water</subject><ispartof>Fresenius environmental bulletin, 2012-01, Vol.21 (10a), p.3122-3126</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784</link.rule.ids></links><search><creatorcontrib>Kabdasli, I</creatorcontrib><creatorcontrib>Tuenay, O</creatorcontrib><creatorcontrib>Konuk, K</creatorcontrib><creatorcontrib>Etcioglu, G</creatorcontrib><creatorcontrib>Kocabas, E</creatorcontrib><title>TREATABILITY OF WASTEWATERS ORIGINATING FROM WATER-BASED PAINT PRODUCTION WITH LATEX BINDER</title><title>Fresenius environmental bulletin</title><description>In the present study, the treatability of wastewaters originating from water-based paint production with latex binders was investigated. The results of characterization study indicated that the wastewaters can exhibit variable characters during the production depending on washing period, and their COD contents varied between 2800 and 15,990 mg/L. Coagulation-flocculation and acid cracking processes were tested as pretreatment applications for both diluted and high strength wastewaters. Acid cracking process proved to be a quite efficient method providing over 95% COD removal, even for the high strength wastewaters. While pretreatment is adequate for direct discharge of the diluted wastewater, high strength needs a further treatment. In the present study, non-biological methods were tested for COD reduction in pretreated high strength wastewaters to fulfill discharge standard. Chemical oxidation using Fenton's reagent proved to be a reliable treatment method for this purpose. Direct oxidation using H sub(2)O sub(2), although requiring long retention times, was also found to be a feasible alternative.</description><subject>Binders</subject><subject>Crack opening displacement</subject><subject>Cracking process</subject><subject>Discharge</subject><subject>High strength</subject><subject>Oxidation</subject><subject>Waste water</subject><issn>1018-4619</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNqFj89LwzAAhXNQcMz9Dzl6KeRXs_SYtukW6JqRZlTxMNqagFLdNNv_b1HvvssHj48H7wYsMMIiYRxnd2AV4xuaw8macLoAz84q6WSua-2eoKlgJ1unOumUbaGxeqMb6XSzgZU1O_jTJ7lsVQn3UjcO7q0pD4XTpoGddltYz8YjzHVTKnsPbkM_Rb_64xIcKuWKbVKbjS5knZwJwZckZH3gL4yRkVOf-pmEYS8Coekw8Eyg0COK0xCox3xgmBEqRox8wCibfyC6BA-_u-ev0-fVx8vx_TWOfpr6D3-6xiPmKaYCMSr-V4mgnIn1rH4DG29VVw</recordid><startdate>20120101</startdate><enddate>20120101</enddate><creator>Kabdasli, I</creator><creator>Tuenay, O</creator><creator>Konuk, K</creator><creator>Etcioglu, G</creator><creator>Kocabas, E</creator><scope>7QH</scope><scope>7ST</scope><scope>7UA</scope><scope>C1K</scope><scope>SOI</scope><scope>7SU</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope></search><sort><creationdate>20120101</creationdate><title>TREATABILITY OF WASTEWATERS ORIGINATING FROM WATER-BASED PAINT PRODUCTION WITH LATEX BINDER</title><author>Kabdasli, I ; Tuenay, O ; Konuk, K ; Etcioglu, G ; Kocabas, E</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p221t-f9af6d442c63e5e42c241e8f235bb6980fa0315ff3e16b414238c10ef10906203</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Binders</topic><topic>Crack opening displacement</topic><topic>Cracking process</topic><topic>Discharge</topic><topic>High strength</topic><topic>Oxidation</topic><topic>Waste water</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kabdasli, I</creatorcontrib><creatorcontrib>Tuenay, O</creatorcontrib><creatorcontrib>Konuk, K</creatorcontrib><creatorcontrib>Etcioglu, G</creatorcontrib><creatorcontrib>Kocabas, E</creatorcontrib><collection>Aqualine</collection><collection>Environment Abstracts</collection><collection>Water Resources Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><collection>Environmental Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Fresenius environmental bulletin</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kabdasli, I</au><au>Tuenay, O</au><au>Konuk, K</au><au>Etcioglu, G</au><au>Kocabas, E</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>TREATABILITY OF WASTEWATERS ORIGINATING FROM WATER-BASED PAINT PRODUCTION WITH LATEX BINDER</atitle><jtitle>Fresenius environmental bulletin</jtitle><date>2012-01-01</date><risdate>2012</risdate><volume>21</volume><issue>10a</issue><spage>3122</spage><epage>3126</epage><pages>3122-3126</pages><issn>1018-4619</issn><abstract>In the present study, the treatability of wastewaters originating from water-based paint production with latex binders was investigated. The results of characterization study indicated that the wastewaters can exhibit variable characters during the production depending on washing period, and their COD contents varied between 2800 and 15,990 mg/L. Coagulation-flocculation and acid cracking processes were tested as pretreatment applications for both diluted and high strength wastewaters. Acid cracking process proved to be a quite efficient method providing over 95% COD removal, even for the high strength wastewaters. While pretreatment is adequate for direct discharge of the diluted wastewater, high strength needs a further treatment. In the present study, non-biological methods were tested for COD reduction in pretreated high strength wastewaters to fulfill discharge standard. Chemical oxidation using Fenton's reagent proved to be a reliable treatment method for this purpose. Direct oxidation using H sub(2)O sub(2), although requiring long retention times, was also found to be a feasible alternative.</abstract><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1018-4619 |
ispartof | Fresenius environmental bulletin, 2012-01, Vol.21 (10a), p.3122-3126 |
issn | 1018-4619 |
language | eng |
recordid | cdi_proquest_miscellaneous_1651380438 |
source | EZB-FREE-00999 freely available EZB journals |
subjects | Binders Crack opening displacement Cracking process Discharge High strength Oxidation Waste water |
title | TREATABILITY OF WASTEWATERS ORIGINATING FROM WATER-BASED PAINT PRODUCTION WITH LATEX BINDER |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T07%3A22%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=TREATABILITY%20OF%20WASTEWATERS%20ORIGINATING%20FROM%20WATER-BASED%20PAINT%20PRODUCTION%20WITH%20LATEX%20BINDER&rft.jtitle=Fresenius%20environmental%20bulletin&rft.au=Kabdasli,%20I&rft.date=2012-01-01&rft.volume=21&rft.issue=10a&rft.spage=3122&rft.epage=3126&rft.pages=3122-3126&rft.issn=1018-4619&rft_id=info:doi/&rft_dat=%3Cproquest%3E1651380438%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1283648738&rft_id=info:pmid/&rfr_iscdi=true |