Aerogel RICH for the Belle II forward PID
The Belle II spectrometer, a follow up of the very successful Belle experiment, is under construction at the SuperKEKB electron-positron collider at KEK in Japan. For the PID system in the forward region of the spectrometer, a proximity focusing ring-imaging Cherenkov (RICH) counter with an aerogel...
Gespeichert in:
Veröffentlicht in: | Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Accelerators, spectrometers, detectors and associated equipment, 2014-12, Vol.766, p.28-31 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 31 |
---|---|
container_issue | |
container_start_page | 28 |
container_title | Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment |
container_volume | 766 |
creator | Nishida, S. Adachi, I. Hamada, N. Hara, K. Iijima, T. Iwata, S. Kakuno, H. Kawai, H. Korpar, S. Kriz^an, P. Ogawa, S. Pestotnik, R. Ŝantelj, L. Seljak, A. Sumiyoshi, T. Tabata, M. Tahirovic, E. Yoshida, K. Yusa, Y. |
description | The Belle II spectrometer, a follow up of the very successful Belle experiment, is under construction at the SuperKEKB electron-positron collider at KEK in Japan. For the PID system in the forward region of the spectrometer, a proximity focusing ring-imaging Cherenkov (RICH) counter with an aerogel radiator is being developed. The counter will provide a 4 sigma separation of pions and kaons up to momenta of 4 GeV/c. For the position sensitive photon sensor, a 144-channel Hybrid Avalanche Photo-Detector (HAPD) has been developed with Hamamatsu Photonics K.K. The readout electronics is based on the custom developed ASIC. The design of the components is currently being finalized and part of their mass production have already started. Herein, we report the final design of the counter and a prototype test conducted with test beams at DESY. |
doi_str_mv | 10.1016/j.nima.2014.06.061 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1651377607</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1651377607</sourcerecordid><originalsourceid>FETCH-LOGICAL-c394t-4aff8c18224999f7b312a104395f1beb52077665e83bd58c6784c091958043d3</originalsourceid><addsrcrecordid>eNotkE1LAzEQhnNQsFb_gKcc9bDrTLL5OtbV2oWCIr2H_Ui0y7Zbkxbx35ulDi8MzLy8zDyE3CHkCCgf-3y_3dU5AyxykEl4QWZpoTMDwK7IdYw9pDJKz8jDwoXx0w30oypX1I-BHr8cfXLD4GhVTYOfOnT0vXq-IZe-HqK7_e9zslm-bMpVtn57rcrFOmu5KY5ZUXuvW9SMFcYYrxqOrEYouBEeG9cIBkpJKZzmTSd0K5UuWjBohE6mjs_J_Tn2EMbvk4tHu9vGNt1T7914ihalQJ4SQCUrO1vbMMYYnLeHkD4PvxbBTihsbycUdkJhQSYh_wNIBlD5</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1651377607</pqid></control><display><type>article</type><title>Aerogel RICH for the Belle II forward PID</title><source>Elsevier ScienceDirect Journals</source><creator>Nishida, S. ; Adachi, I. ; Hamada, N. ; Hara, K. ; Iijima, T. ; Iwata, S. ; Kakuno, H. ; Kawai, H. ; Korpar, S. ; Kriz^an, P. ; Ogawa, S. ; Pestotnik, R. ; Ŝantelj, L. ; Seljak, A. ; Sumiyoshi, T. ; Tabata, M. ; Tahirovic, E. ; Yoshida, K. ; Yusa, Y.</creator><creatorcontrib>Nishida, S. ; Adachi, I. ; Hamada, N. ; Hara, K. ; Iijima, T. ; Iwata, S. ; Kakuno, H. ; Kawai, H. ; Korpar, S. ; Kriz^an, P. ; Ogawa, S. ; Pestotnik, R. ; Ŝantelj, L. ; Seljak, A. ; Sumiyoshi, T. ; Tabata, M. ; Tahirovic, E. ; Yoshida, K. ; Yusa, Y.</creatorcontrib><description>The Belle II spectrometer, a follow up of the very successful Belle experiment, is under construction at the SuperKEKB electron-positron collider at KEK in Japan. For the PID system in the forward region of the spectrometer, a proximity focusing ring-imaging Cherenkov (RICH) counter with an aerogel radiator is being developed. The counter will provide a 4 sigma separation of pions and kaons up to momenta of 4 GeV/c. For the position sensitive photon sensor, a 144-channel Hybrid Avalanche Photo-Detector (HAPD) has been developed with Hamamatsu Photonics K.K. The readout electronics is based on the custom developed ASIC. The design of the components is currently being finalized and part of their mass production have already started. Herein, we report the final design of the counter and a prototype test conducted with test beams at DESY.</description><identifier>ISSN: 0168-9002</identifier><identifier>DOI: 10.1016/j.nima.2014.06.061</identifier><language>eng</language><subject>Aerogels ; Beams (radiation) ; Design engineering ; Detectors ; Electronics ; Mass production ; Proportional integral derivative ; Spectrometers</subject><ispartof>Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 2014-12, Vol.766, p.28-31</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c394t-4aff8c18224999f7b312a104395f1beb52077665e83bd58c6784c091958043d3</citedby><cites>FETCH-LOGICAL-c394t-4aff8c18224999f7b312a104395f1beb52077665e83bd58c6784c091958043d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids></links><search><creatorcontrib>Nishida, S.</creatorcontrib><creatorcontrib>Adachi, I.</creatorcontrib><creatorcontrib>Hamada, N.</creatorcontrib><creatorcontrib>Hara, K.</creatorcontrib><creatorcontrib>Iijima, T.</creatorcontrib><creatorcontrib>Iwata, S.</creatorcontrib><creatorcontrib>Kakuno, H.</creatorcontrib><creatorcontrib>Kawai, H.</creatorcontrib><creatorcontrib>Korpar, S.</creatorcontrib><creatorcontrib>Kriz^an, P.</creatorcontrib><creatorcontrib>Ogawa, S.</creatorcontrib><creatorcontrib>Pestotnik, R.</creatorcontrib><creatorcontrib>Ŝantelj, L.</creatorcontrib><creatorcontrib>Seljak, A.</creatorcontrib><creatorcontrib>Sumiyoshi, T.</creatorcontrib><creatorcontrib>Tabata, M.</creatorcontrib><creatorcontrib>Tahirovic, E.</creatorcontrib><creatorcontrib>Yoshida, K.</creatorcontrib><creatorcontrib>Yusa, Y.</creatorcontrib><title>Aerogel RICH for the Belle II forward PID</title><title>Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment</title><description>The Belle II spectrometer, a follow up of the very successful Belle experiment, is under construction at the SuperKEKB electron-positron collider at KEK in Japan. For the PID system in the forward region of the spectrometer, a proximity focusing ring-imaging Cherenkov (RICH) counter with an aerogel radiator is being developed. The counter will provide a 4 sigma separation of pions and kaons up to momenta of 4 GeV/c. For the position sensitive photon sensor, a 144-channel Hybrid Avalanche Photo-Detector (HAPD) has been developed with Hamamatsu Photonics K.K. The readout electronics is based on the custom developed ASIC. The design of the components is currently being finalized and part of their mass production have already started. Herein, we report the final design of the counter and a prototype test conducted with test beams at DESY.</description><subject>Aerogels</subject><subject>Beams (radiation)</subject><subject>Design engineering</subject><subject>Detectors</subject><subject>Electronics</subject><subject>Mass production</subject><subject>Proportional integral derivative</subject><subject>Spectrometers</subject><issn>0168-9002</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNotkE1LAzEQhnNQsFb_gKcc9bDrTLL5OtbV2oWCIr2H_Ui0y7Zbkxbx35ulDi8MzLy8zDyE3CHkCCgf-3y_3dU5AyxykEl4QWZpoTMDwK7IdYw9pDJKz8jDwoXx0w30oypX1I-BHr8cfXLD4GhVTYOfOnT0vXq-IZe-HqK7_e9zslm-bMpVtn57rcrFOmu5KY5ZUXuvW9SMFcYYrxqOrEYouBEeG9cIBkpJKZzmTSd0K5UuWjBohE6mjs_J_Tn2EMbvk4tHu9vGNt1T7914ihalQJ4SQCUrO1vbMMYYnLeHkD4PvxbBTihsbycUdkJhQSYh_wNIBlD5</recordid><startdate>20141201</startdate><enddate>20141201</enddate><creator>Nishida, S.</creator><creator>Adachi, I.</creator><creator>Hamada, N.</creator><creator>Hara, K.</creator><creator>Iijima, T.</creator><creator>Iwata, S.</creator><creator>Kakuno, H.</creator><creator>Kawai, H.</creator><creator>Korpar, S.</creator><creator>Kriz^an, P.</creator><creator>Ogawa, S.</creator><creator>Pestotnik, R.</creator><creator>Ŝantelj, L.</creator><creator>Seljak, A.</creator><creator>Sumiyoshi, T.</creator><creator>Tabata, M.</creator><creator>Tahirovic, E.</creator><creator>Yoshida, K.</creator><creator>Yusa, Y.</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20141201</creationdate><title>Aerogel RICH for the Belle II forward PID</title><author>Nishida, S. ; Adachi, I. ; Hamada, N. ; Hara, K. ; Iijima, T. ; Iwata, S. ; Kakuno, H. ; Kawai, H. ; Korpar, S. ; Kriz^an, P. ; Ogawa, S. ; Pestotnik, R. ; Ŝantelj, L. ; Seljak, A. ; Sumiyoshi, T. ; Tabata, M. ; Tahirovic, E. ; Yoshida, K. ; Yusa, Y.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c394t-4aff8c18224999f7b312a104395f1beb52077665e83bd58c6784c091958043d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Aerogels</topic><topic>Beams (radiation)</topic><topic>Design engineering</topic><topic>Detectors</topic><topic>Electronics</topic><topic>Mass production</topic><topic>Proportional integral derivative</topic><topic>Spectrometers</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Nishida, S.</creatorcontrib><creatorcontrib>Adachi, I.</creatorcontrib><creatorcontrib>Hamada, N.</creatorcontrib><creatorcontrib>Hara, K.</creatorcontrib><creatorcontrib>Iijima, T.</creatorcontrib><creatorcontrib>Iwata, S.</creatorcontrib><creatorcontrib>Kakuno, H.</creatorcontrib><creatorcontrib>Kawai, H.</creatorcontrib><creatorcontrib>Korpar, S.</creatorcontrib><creatorcontrib>Kriz^an, P.</creatorcontrib><creatorcontrib>Ogawa, S.</creatorcontrib><creatorcontrib>Pestotnik, R.</creatorcontrib><creatorcontrib>Ŝantelj, L.</creatorcontrib><creatorcontrib>Seljak, A.</creatorcontrib><creatorcontrib>Sumiyoshi, T.</creatorcontrib><creatorcontrib>Tabata, M.</creatorcontrib><creatorcontrib>Tahirovic, E.</creatorcontrib><creatorcontrib>Yoshida, K.</creatorcontrib><creatorcontrib>Yusa, Y.</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Nishida, S.</au><au>Adachi, I.</au><au>Hamada, N.</au><au>Hara, K.</au><au>Iijima, T.</au><au>Iwata, S.</au><au>Kakuno, H.</au><au>Kawai, H.</au><au>Korpar, S.</au><au>Kriz^an, P.</au><au>Ogawa, S.</au><au>Pestotnik, R.</au><au>Ŝantelj, L.</au><au>Seljak, A.</au><au>Sumiyoshi, T.</au><au>Tabata, M.</au><au>Tahirovic, E.</au><au>Yoshida, K.</au><au>Yusa, Y.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Aerogel RICH for the Belle II forward PID</atitle><jtitle>Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment</jtitle><date>2014-12-01</date><risdate>2014</risdate><volume>766</volume><spage>28</spage><epage>31</epage><pages>28-31</pages><issn>0168-9002</issn><abstract>The Belle II spectrometer, a follow up of the very successful Belle experiment, is under construction at the SuperKEKB electron-positron collider at KEK in Japan. For the PID system in the forward region of the spectrometer, a proximity focusing ring-imaging Cherenkov (RICH) counter with an aerogel radiator is being developed. The counter will provide a 4 sigma separation of pions and kaons up to momenta of 4 GeV/c. For the position sensitive photon sensor, a 144-channel Hybrid Avalanche Photo-Detector (HAPD) has been developed with Hamamatsu Photonics K.K. The readout electronics is based on the custom developed ASIC. The design of the components is currently being finalized and part of their mass production have already started. Herein, we report the final design of the counter and a prototype test conducted with test beams at DESY.</abstract><doi>10.1016/j.nima.2014.06.061</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0168-9002 |
ispartof | Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 2014-12, Vol.766, p.28-31 |
issn | 0168-9002 |
language | eng |
recordid | cdi_proquest_miscellaneous_1651377607 |
source | Elsevier ScienceDirect Journals |
subjects | Aerogels Beams (radiation) Design engineering Detectors Electronics Mass production Proportional integral derivative Spectrometers |
title | Aerogel RICH for the Belle II forward PID |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T15%3A46%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Aerogel%20RICH%20for%20the%20Belle%20II%20forward%20PID&rft.jtitle=Nuclear%20instruments%20&%20methods%20in%20physics%20research.%20Section%20A,%20Accelerators,%20spectrometers,%20detectors%20and%20associated%20equipment&rft.au=Nishida,%20S.&rft.date=2014-12-01&rft.volume=766&rft.spage=28&rft.epage=31&rft.pages=28-31&rft.issn=0168-9002&rft_id=info:doi/10.1016/j.nima.2014.06.061&rft_dat=%3Cproquest_cross%3E1651377607%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1651377607&rft_id=info:pmid/&rfr_iscdi=true |