Evaluation of the performance of a passive–active vibration isolation system

The behavior of a feedforward active isolation system subjected to actuator output constraints is investigated. Distributed parameter models are developed to analyze the system response, and to produce a transfer matrix for the design of an integrated passive–active isolation system. Cost functions...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Mechanical systems and signal processing 2015-01, Vol.50-51, p.480-497
Hauptverfasser: Sun, L.L., Hansen, C.H., Doolan, C.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 497
container_issue
container_start_page 480
container_title Mechanical systems and signal processing
container_volume 50-51
creator Sun, L.L.
Hansen, C.H.
Doolan, C.
description The behavior of a feedforward active isolation system subjected to actuator output constraints is investigated. Distributed parameter models are developed to analyze the system response, and to produce a transfer matrix for the design of an integrated passive–active isolation system. Cost functions considered here comprise a combination of the vibration transmission energy and the sum of the squared control forces. The example system considered is a rigid body connected to a simply supported plate via two isolation mounts. The overall isolation performance is evaluated by numerical simulation. The results show that the control strategies which rely on unconstrained actuator outputs may give substantial power transmission reductions over a wide frequency range, but also require large control force amplitudes to control excited vibration modes of the system. Expected power transmission reductions for modified control strategies that incorporate constrained actuator outputs are considerably less than typical reductions with unconstrained actuator outputs. The active system with constrained control force outputs is shown to be more effective at the resonance frequencies of the supporting plate. However, in the frequency range in which rigid body modes are present, the control strategies employed using constrained actuator outputs can only achieve 5–10dB power transmission reduction, while at off-resonance frequencies, little or no power transmission reduction can be obtained with realistic control forces. Analysis of the wave effects in the passive mounts is also presented. •Effects of actuator output constraints on feed-forward active isolation systems.•Modified cost functions are proposed to limit control force magnitudes.•Maximum control force is required at frequency corresponding to rigid body mode.•Constrained control systems can only achieve 5-10 dB power flow reductions.
doi_str_mv 10.1016/j.ymssp.2014.05.008
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1642325302</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S088832701400137X</els_id><sourcerecordid>1642325302</sourcerecordid><originalsourceid>FETCH-LOGICAL-c406t-f203fb3134d5d97f45ef34bd432e9345ee838b63b3e0983133e77aa485f8b773</originalsourceid><addsrcrecordid>eNp9kLtOxDAQRS0EEsvjC2hS0iSMH0mcggKtloe0gmZ7y0nGwqtkHexspO34B_6QL8FLqKnmzujeGc0h5IZCRoEWd9vs0IcwZAyoyCDPAOQJWVCoipQyWpySBUgpU85KOCcXIWwBoBJQLMjratLdXo_W7RJnkvEdkwG9cb7XuwaPI50MOgQ74ffnl27GKJLJ1n6O2OC6WYVDGLG_ImdGdwGv_-ol2TyuNsvndP329LJ8WKdNvDqmhgE3NadctHlblUbkaLioW8EZVjx2KLmsC15zhEpGH8ey1FrI3Mi6LPkluZ3XDt597DGMqrehwa7TO3T7oGghGGc5BxatfLY23oXg0ajB2177g6KgjvDUVv3CU0d4CnIV4cXU_ZzC-MRk0avQWIxEWuuxGVXr7L_5HzR1eu0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1642325302</pqid></control><display><type>article</type><title>Evaluation of the performance of a passive–active vibration isolation system</title><source>Access via ScienceDirect (Elsevier)</source><creator>Sun, L.L. ; Hansen, C.H. ; Doolan, C.</creator><creatorcontrib>Sun, L.L. ; Hansen, C.H. ; Doolan, C.</creatorcontrib><description>The behavior of a feedforward active isolation system subjected to actuator output constraints is investigated. Distributed parameter models are developed to analyze the system response, and to produce a transfer matrix for the design of an integrated passive–active isolation system. Cost functions considered here comprise a combination of the vibration transmission energy and the sum of the squared control forces. The example system considered is a rigid body connected to a simply supported plate via two isolation mounts. The overall isolation performance is evaluated by numerical simulation. The results show that the control strategies which rely on unconstrained actuator outputs may give substantial power transmission reductions over a wide frequency range, but also require large control force amplitudes to control excited vibration modes of the system. Expected power transmission reductions for modified control strategies that incorporate constrained actuator outputs are considerably less than typical reductions with unconstrained actuator outputs. The active system with constrained control force outputs is shown to be more effective at the resonance frequencies of the supporting plate. However, in the frequency range in which rigid body modes are present, the control strategies employed using constrained actuator outputs can only achieve 5–10dB power transmission reduction, while at off-resonance frequencies, little or no power transmission reduction can be obtained with realistic control forces. Analysis of the wave effects in the passive mounts is also presented. •Effects of actuator output constraints on feed-forward active isolation systems.•Modified cost functions are proposed to limit control force magnitudes.•Maximum control force is required at frequency corresponding to rigid body mode.•Constrained control systems can only achieve 5-10 dB power flow reductions.</description><identifier>ISSN: 0888-3270</identifier><identifier>EISSN: 1096-1216</identifier><identifier>DOI: 10.1016/j.ymssp.2014.05.008</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Actuators ; Constraints ; Control force constraint ; Control systems ; Isolation systems ; Passive–active isolation ; Power transmission ; Reduction ; Rigid-body dynamics ; Strategy ; Transfer matrix</subject><ispartof>Mechanical systems and signal processing, 2015-01, Vol.50-51, p.480-497</ispartof><rights>2014 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c406t-f203fb3134d5d97f45ef34bd432e9345ee838b63b3e0983133e77aa485f8b773</citedby><cites>FETCH-LOGICAL-c406t-f203fb3134d5d97f45ef34bd432e9345ee838b63b3e0983133e77aa485f8b773</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.ymssp.2014.05.008$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids></links><search><creatorcontrib>Sun, L.L.</creatorcontrib><creatorcontrib>Hansen, C.H.</creatorcontrib><creatorcontrib>Doolan, C.</creatorcontrib><title>Evaluation of the performance of a passive–active vibration isolation system</title><title>Mechanical systems and signal processing</title><description>The behavior of a feedforward active isolation system subjected to actuator output constraints is investigated. Distributed parameter models are developed to analyze the system response, and to produce a transfer matrix for the design of an integrated passive–active isolation system. Cost functions considered here comprise a combination of the vibration transmission energy and the sum of the squared control forces. The example system considered is a rigid body connected to a simply supported plate via two isolation mounts. The overall isolation performance is evaluated by numerical simulation. The results show that the control strategies which rely on unconstrained actuator outputs may give substantial power transmission reductions over a wide frequency range, but also require large control force amplitudes to control excited vibration modes of the system. Expected power transmission reductions for modified control strategies that incorporate constrained actuator outputs are considerably less than typical reductions with unconstrained actuator outputs. The active system with constrained control force outputs is shown to be more effective at the resonance frequencies of the supporting plate. However, in the frequency range in which rigid body modes are present, the control strategies employed using constrained actuator outputs can only achieve 5–10dB power transmission reduction, while at off-resonance frequencies, little or no power transmission reduction can be obtained with realistic control forces. Analysis of the wave effects in the passive mounts is also presented. •Effects of actuator output constraints on feed-forward active isolation systems.•Modified cost functions are proposed to limit control force magnitudes.•Maximum control force is required at frequency corresponding to rigid body mode.•Constrained control systems can only achieve 5-10 dB power flow reductions.</description><subject>Actuators</subject><subject>Constraints</subject><subject>Control force constraint</subject><subject>Control systems</subject><subject>Isolation systems</subject><subject>Passive–active isolation</subject><subject>Power transmission</subject><subject>Reduction</subject><subject>Rigid-body dynamics</subject><subject>Strategy</subject><subject>Transfer matrix</subject><issn>0888-3270</issn><issn>1096-1216</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNp9kLtOxDAQRS0EEsvjC2hS0iSMH0mcggKtloe0gmZ7y0nGwqtkHexspO34B_6QL8FLqKnmzujeGc0h5IZCRoEWd9vs0IcwZAyoyCDPAOQJWVCoipQyWpySBUgpU85KOCcXIWwBoBJQLMjratLdXo_W7RJnkvEdkwG9cb7XuwaPI50MOgQ74ffnl27GKJLJ1n6O2OC6WYVDGLG_ImdGdwGv_-ol2TyuNsvndP329LJ8WKdNvDqmhgE3NadctHlblUbkaLioW8EZVjx2KLmsC15zhEpGH8ey1FrI3Mi6LPkluZ3XDt597DGMqrehwa7TO3T7oGghGGc5BxatfLY23oXg0ajB2177g6KgjvDUVv3CU0d4CnIV4cXU_ZzC-MRk0avQWIxEWuuxGVXr7L_5HzR1eu0</recordid><startdate>20150101</startdate><enddate>20150101</enddate><creator>Sun, L.L.</creator><creator>Hansen, C.H.</creator><creator>Doolan, C.</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SC</scope><scope>7SP</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>JQ2</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope></search><sort><creationdate>20150101</creationdate><title>Evaluation of the performance of a passive–active vibration isolation system</title><author>Sun, L.L. ; Hansen, C.H. ; Doolan, C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c406t-f203fb3134d5d97f45ef34bd432e9345ee838b63b3e0983133e77aa485f8b773</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Actuators</topic><topic>Constraints</topic><topic>Control force constraint</topic><topic>Control systems</topic><topic>Isolation systems</topic><topic>Passive–active isolation</topic><topic>Power transmission</topic><topic>Reduction</topic><topic>Rigid-body dynamics</topic><topic>Strategy</topic><topic>Transfer matrix</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sun, L.L.</creatorcontrib><creatorcontrib>Hansen, C.H.</creatorcontrib><creatorcontrib>Doolan, C.</creatorcontrib><collection>CrossRef</collection><collection>Computer and Information Systems Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><jtitle>Mechanical systems and signal processing</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sun, L.L.</au><au>Hansen, C.H.</au><au>Doolan, C.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of the performance of a passive–active vibration isolation system</atitle><jtitle>Mechanical systems and signal processing</jtitle><date>2015-01-01</date><risdate>2015</risdate><volume>50-51</volume><spage>480</spage><epage>497</epage><pages>480-497</pages><issn>0888-3270</issn><eissn>1096-1216</eissn><abstract>The behavior of a feedforward active isolation system subjected to actuator output constraints is investigated. Distributed parameter models are developed to analyze the system response, and to produce a transfer matrix for the design of an integrated passive–active isolation system. Cost functions considered here comprise a combination of the vibration transmission energy and the sum of the squared control forces. The example system considered is a rigid body connected to a simply supported plate via two isolation mounts. The overall isolation performance is evaluated by numerical simulation. The results show that the control strategies which rely on unconstrained actuator outputs may give substantial power transmission reductions over a wide frequency range, but also require large control force amplitudes to control excited vibration modes of the system. Expected power transmission reductions for modified control strategies that incorporate constrained actuator outputs are considerably less than typical reductions with unconstrained actuator outputs. The active system with constrained control force outputs is shown to be more effective at the resonance frequencies of the supporting plate. However, in the frequency range in which rigid body modes are present, the control strategies employed using constrained actuator outputs can only achieve 5–10dB power transmission reduction, while at off-resonance frequencies, little or no power transmission reduction can be obtained with realistic control forces. Analysis of the wave effects in the passive mounts is also presented. •Effects of actuator output constraints on feed-forward active isolation systems.•Modified cost functions are proposed to limit control force magnitudes.•Maximum control force is required at frequency corresponding to rigid body mode.•Constrained control systems can only achieve 5-10 dB power flow reductions.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.ymssp.2014.05.008</doi><tpages>18</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0888-3270
ispartof Mechanical systems and signal processing, 2015-01, Vol.50-51, p.480-497
issn 0888-3270
1096-1216
language eng
recordid cdi_proquest_miscellaneous_1642325302
source Access via ScienceDirect (Elsevier)
subjects Actuators
Constraints
Control force constraint
Control systems
Isolation systems
Passive–active isolation
Power transmission
Reduction
Rigid-body dynamics
Strategy
Transfer matrix
title Evaluation of the performance of a passive–active vibration isolation system
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T11%3A01%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20the%20performance%20of%20a%20passive%E2%80%93active%20vibration%20isolation%20system&rft.jtitle=Mechanical%20systems%20and%20signal%20processing&rft.au=Sun,%20L.L.&rft.date=2015-01-01&rft.volume=50-51&rft.spage=480&rft.epage=497&rft.pages=480-497&rft.issn=0888-3270&rft.eissn=1096-1216&rft_id=info:doi/10.1016/j.ymssp.2014.05.008&rft_dat=%3Cproquest_cross%3E1642325302%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1642325302&rft_id=info:pmid/&rft_els_id=S088832701400137X&rfr_iscdi=true