Analisis comparativo de las mediciones de material particulado PM sub( 10)/Comparative analysis of PM sub( 10) particulate matter

This paper presents the concentrations of PM10 in the urban area of Riohacha, Colombia. Two simultaneous sampling methods are compared. The high-volume sampler PM10, Graseby Andersen and a nephelometer DataRam 4 (Thermo Electron corporation). Data were collected over three months in two sites (Desal...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Revista Facultad de Ingeniería 2011-03 (58), p.27-27
Hauptverfasser: Alvarado, Roberto Rojano, Montiel, Jhonny Perez, Deluque, Jorge
Format: Artikel
Sprache:spa
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 27
container_issue 58
container_start_page 27
container_title Revista Facultad de Ingeniería
container_volume
creator Alvarado, Roberto Rojano
Montiel, Jhonny Perez
Deluque, Jorge
description This paper presents the concentrations of PM10 in the urban area of Riohacha, Colombia. Two simultaneous sampling methods are compared. The high-volume sampler PM10, Graseby Andersen and a nephelometer DataRam 4 (Thermo Electron corporation). Data were collected over three months in two sites (Desalud and Bienestar) of the urban area of Riohacha. The results show that the average PM10 concentration was 23.64 mu g/m super( 3) and 36.86 mu g/m super( 3) in the two stations using the DataRam 4 and 25.09 mgr; g/m super( 3) and 36.64 mu g/m super( 3) using the high-volume sampler PM10. The correlation analysis shows a positive consistency for all the pairs in these two monitoring methods: R2 = 0.5377 for the season Desalud and R2 = 0.7276 for the season Bienestar. The results showed that the photometric method (DataRam 4) can be used to determine concentrations of particulate matter PM10 at Riohacha environmental conditions.
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_1642288607</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1642288607</sourcerecordid><originalsourceid>FETCH-LOGICAL-p667-1cd117a0594704daf5422809eeaef85cad5d98fc0e977251d0119d71b69891663</originalsourceid><addsrcrecordid>eNqN0D1PwzAQgOEMIFEK_8FjGSLOTmzHYxXxJRXB0L262hfJyIlDnCAx8s9JARVGppNO7z3DnWQL4AJyJQo4y85TegGQlYJqkX2sOww--cRsbHsccPRvkTliARNryXnrY0fpsGlxpMFjYHM2ejsFdJE9P7I07VeMw9V1fRSI4cy-H9jY_G1-b8cvcBYvstMGQ6LLn7nMtrc32_o-3zzdPdTrTd4rpXNuHecaQZpSQ-mwkaUQFRgipKaSFp10pmoskNFaSO6Ac-M03ytTGa5UscxW32w_xNeJ0rhrfbIUAnYUp7Tj6gDOT9H_SIUpJFcgi0-qOGl2</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1629351605</pqid></control><display><type>article</type><title>Analisis comparativo de las mediciones de material particulado PM sub( 10)/Comparative analysis of PM sub( 10) particulate matter</title><source>EZB-FREE-00999 freely available EZB journals</source><creator>Alvarado, Roberto Rojano ; Montiel, Jhonny Perez ; Deluque, Jorge</creator><creatorcontrib>Alvarado, Roberto Rojano ; Montiel, Jhonny Perez ; Deluque, Jorge</creatorcontrib><description>This paper presents the concentrations of PM10 in the urban area of Riohacha, Colombia. Two simultaneous sampling methods are compared. The high-volume sampler PM10, Graseby Andersen and a nephelometer DataRam 4 (Thermo Electron corporation). Data were collected over three months in two sites (Desalud and Bienestar) of the urban area of Riohacha. The results show that the average PM10 concentration was 23.64 mu g/m super( 3) and 36.86 mu g/m super( 3) in the two stations using the DataRam 4 and 25.09 mgr; g/m super( 3) and 36.64 mu g/m super( 3) using the high-volume sampler PM10. The correlation analysis shows a positive consistency for all the pairs in these two monitoring methods: R2 = 0.5377 for the season Desalud and R2 = 0.7276 for the season Bienestar. The results showed that the photometric method (DataRam 4) can be used to determine concentrations of particulate matter PM10 at Riohacha environmental conditions.</description><identifier>ISSN: 0120-6230</identifier><language>spa</language><subject>Consistency ; Environmental monitoring ; Particulate emissions ; Photometry ; Samplers ; Seasons ; Stations ; Urban areas</subject><ispartof>Revista Facultad de Ingeniería, 2011-03 (58), p.27-27</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784</link.rule.ids></links><search><creatorcontrib>Alvarado, Roberto Rojano</creatorcontrib><creatorcontrib>Montiel, Jhonny Perez</creatorcontrib><creatorcontrib>Deluque, Jorge</creatorcontrib><title>Analisis comparativo de las mediciones de material particulado PM sub( 10)/Comparative analysis of PM sub( 10) particulate matter</title><title>Revista Facultad de Ingeniería</title><description>This paper presents the concentrations of PM10 in the urban area of Riohacha, Colombia. Two simultaneous sampling methods are compared. The high-volume sampler PM10, Graseby Andersen and a nephelometer DataRam 4 (Thermo Electron corporation). Data were collected over three months in two sites (Desalud and Bienestar) of the urban area of Riohacha. The results show that the average PM10 concentration was 23.64 mu g/m super( 3) and 36.86 mu g/m super( 3) in the two stations using the DataRam 4 and 25.09 mgr; g/m super( 3) and 36.64 mu g/m super( 3) using the high-volume sampler PM10. The correlation analysis shows a positive consistency for all the pairs in these two monitoring methods: R2 = 0.5377 for the season Desalud and R2 = 0.7276 for the season Bienestar. The results showed that the photometric method (DataRam 4) can be used to determine concentrations of particulate matter PM10 at Riohacha environmental conditions.</description><subject>Consistency</subject><subject>Environmental monitoring</subject><subject>Particulate emissions</subject><subject>Photometry</subject><subject>Samplers</subject><subject>Seasons</subject><subject>Stations</subject><subject>Urban areas</subject><issn>0120-6230</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNqN0D1PwzAQgOEMIFEK_8FjGSLOTmzHYxXxJRXB0L262hfJyIlDnCAx8s9JARVGppNO7z3DnWQL4AJyJQo4y85TegGQlYJqkX2sOww--cRsbHsccPRvkTliARNryXnrY0fpsGlxpMFjYHM2ejsFdJE9P7I07VeMw9V1fRSI4cy-H9jY_G1-b8cvcBYvstMGQ6LLn7nMtrc32_o-3zzdPdTrTd4rpXNuHecaQZpSQ-mwkaUQFRgipKaSFp10pmoskNFaSO6Ac-M03ytTGa5UscxW32w_xNeJ0rhrfbIUAnYUp7Tj6gDOT9H_SIUpJFcgi0-qOGl2</recordid><startdate>20110301</startdate><enddate>20110301</enddate><creator>Alvarado, Roberto Rojano</creator><creator>Montiel, Jhonny Perez</creator><creator>Deluque, Jorge</creator><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope></search><sort><creationdate>20110301</creationdate><title>Analisis comparativo de las mediciones de material particulado PM sub( 10)/Comparative analysis of PM sub( 10) particulate matter</title><author>Alvarado, Roberto Rojano ; Montiel, Jhonny Perez ; Deluque, Jorge</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p667-1cd117a0594704daf5422809eeaef85cad5d98fc0e977251d0119d71b69891663</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>spa</language><creationdate>2011</creationdate><topic>Consistency</topic><topic>Environmental monitoring</topic><topic>Particulate emissions</topic><topic>Photometry</topic><topic>Samplers</topic><topic>Seasons</topic><topic>Stations</topic><topic>Urban areas</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Alvarado, Roberto Rojano</creatorcontrib><creatorcontrib>Montiel, Jhonny Perez</creatorcontrib><creatorcontrib>Deluque, Jorge</creatorcontrib><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Revista Facultad de Ingeniería</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Alvarado, Roberto Rojano</au><au>Montiel, Jhonny Perez</au><au>Deluque, Jorge</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Analisis comparativo de las mediciones de material particulado PM sub( 10)/Comparative analysis of PM sub( 10) particulate matter</atitle><jtitle>Revista Facultad de Ingeniería</jtitle><date>2011-03-01</date><risdate>2011</risdate><issue>58</issue><spage>27</spage><epage>27</epage><pages>27-27</pages><issn>0120-6230</issn><abstract>This paper presents the concentrations of PM10 in the urban area of Riohacha, Colombia. Two simultaneous sampling methods are compared. The high-volume sampler PM10, Graseby Andersen and a nephelometer DataRam 4 (Thermo Electron corporation). Data were collected over three months in two sites (Desalud and Bienestar) of the urban area of Riohacha. The results show that the average PM10 concentration was 23.64 mu g/m super( 3) and 36.86 mu g/m super( 3) in the two stations using the DataRam 4 and 25.09 mgr; g/m super( 3) and 36.64 mu g/m super( 3) using the high-volume sampler PM10. The correlation analysis shows a positive consistency for all the pairs in these two monitoring methods: R2 = 0.5377 for the season Desalud and R2 = 0.7276 for the season Bienestar. The results showed that the photometric method (DataRam 4) can be used to determine concentrations of particulate matter PM10 at Riohacha environmental conditions.</abstract><tpages>1</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0120-6230
ispartof Revista Facultad de Ingeniería, 2011-03 (58), p.27-27
issn 0120-6230
language spa
recordid cdi_proquest_miscellaneous_1642288607
source EZB-FREE-00999 freely available EZB journals
subjects Consistency
Environmental monitoring
Particulate emissions
Photometry
Samplers
Seasons
Stations
Urban areas
title Analisis comparativo de las mediciones de material particulado PM sub( 10)/Comparative analysis of PM sub( 10) particulate matter
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T07%3A28%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Analisis%20comparativo%20de%20las%20mediciones%20de%20material%20particulado%20PM%20sub(%2010)/Comparative%20analysis%20of%20PM%20sub(%2010)%20particulate%20matter&rft.jtitle=Revista%20Facultad%20de%20Ingenier%C3%ADa&rft.au=Alvarado,%20Roberto%20Rojano&rft.date=2011-03-01&rft.issue=58&rft.spage=27&rft.epage=27&rft.pages=27-27&rft.issn=0120-6230&rft_id=info:doi/&rft_dat=%3Cproquest%3E1642288607%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1629351605&rft_id=info:pmid/&rfr_iscdi=true