Neuroendoscopic biopsy of brain lesions: accuracy and complications

The authors conducted a study to analyze the accuracy of neuroendoscopic biopsies of ventricular and periventricular lesions and record any difficulties or complications of the neuroendoscopic biopsy procedure. A total of 50 patients with different diseases consecutively underwent endoscopic biopsy...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of neurosurgery 2015-01, Vol.122 (1), p.34-39
Hauptverfasser: Giannetti, Alexandre Varella, Alvarenga, Alexandre Yugo Holayama, de Lima, Thiago Oliveira Lemos, Pedrosa, Hugo Abi-Sáber Rodrigues, Souweidane, Mark M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 39
container_issue 1
container_start_page 34
container_title Journal of neurosurgery
container_volume 122
creator Giannetti, Alexandre Varella
Alvarenga, Alexandre Yugo Holayama
de Lima, Thiago Oliveira Lemos
Pedrosa, Hugo Abi-Sáber Rodrigues
Souweidane, Mark M
description The authors conducted a study to analyze the accuracy of neuroendoscopic biopsies of ventricular and periventricular lesions and record any difficulties or complications of the neuroendoscopic biopsy procedure. A total of 50 patients with different diseases consecutively underwent endoscopic biopsy procedures. The biopsy result was considered diagnostic if the pathologist reported any specific finding on which clinicians could base decisions about treatment or observation. The biopsy result was referred to as accurate if the results matched results of a sample obtained later or if the treatment response and disease evolution were compatible with the diagnosis. The biopsy result was considered inaccurate if results showed any relevant differences from those of the later sample or if the patient's disease did not evolve as expected. Complications were recorded and compared with those found in a literature review. For 2 patients, the procedure had to be terminated. The biopsy diagnostic rate was 89.6%, and the accuracy rate was 86%. Complications associated with the procedure were 3 hemorrhages (6%), 2 infections (4%), and 1 death (2%); no reoperations were needed. Endoscopic biopsy seems to be an accurate procedure with acceptable morbidity and mortality rates.
doi_str_mv 10.3171/2014.9.JNS132648
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1641858452</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1641858452</sourcerecordid><originalsourceid>FETCH-LOGICAL-c407t-c902267574fa2f76c9421282d96a331fc941e22bbb04a1e7da856ad77a80abf53</originalsourceid><addsrcrecordid>eNo9kEtPwzAQhC0EoqVw54Ry5JLiV_zghiqeqsoBOFtrx5aCkjjYzaH_nlSFnlarnRntfAhdE7xkRJI7iglf6uXb5oMwKrg6QXOiGSux0OwUzTGmtGRYVTN0kfM3xkRwQc_RjFZMEK7kHK02fkzR93XMLg6NK2wTh7wrYihsgqYvWp-b2Of7ApwbE7hdAX1duNgNbeNgu79dorMAbfZXf3OBvp4eP1cv5fr9-XX1sC4dx3JbOj29I2QleQAapHCaU0IVrbUAxkiYduIptdZiDsTLGlQloJYSFAYbKrZAt4fcIcWf0eet6ZrsfNtC7-OYzdSOqErxik5SfJC6FHNOPpghNR2knSHY7NGZPTqjzRHdZLn5Sx9t5-uj4Z8V-wVsRmlE</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1641858452</pqid></control><display><type>article</type><title>Neuroendoscopic biopsy of brain lesions: accuracy and complications</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Giannetti, Alexandre Varella ; Alvarenga, Alexandre Yugo Holayama ; de Lima, Thiago Oliveira Lemos ; Pedrosa, Hugo Abi-Sáber Rodrigues ; Souweidane, Mark M</creator><creatorcontrib>Giannetti, Alexandre Varella ; Alvarenga, Alexandre Yugo Holayama ; de Lima, Thiago Oliveira Lemos ; Pedrosa, Hugo Abi-Sáber Rodrigues ; Souweidane, Mark M</creatorcontrib><description>The authors conducted a study to analyze the accuracy of neuroendoscopic biopsies of ventricular and periventricular lesions and record any difficulties or complications of the neuroendoscopic biopsy procedure. A total of 50 patients with different diseases consecutively underwent endoscopic biopsy procedures. The biopsy result was considered diagnostic if the pathologist reported any specific finding on which clinicians could base decisions about treatment or observation. The biopsy result was referred to as accurate if the results matched results of a sample obtained later or if the treatment response and disease evolution were compatible with the diagnosis. The biopsy result was considered inaccurate if results showed any relevant differences from those of the later sample or if the patient's disease did not evolve as expected. Complications were recorded and compared with those found in a literature review. For 2 patients, the procedure had to be terminated. The biopsy diagnostic rate was 89.6%, and the accuracy rate was 86%. Complications associated with the procedure were 3 hemorrhages (6%), 2 infections (4%), and 1 death (2%); no reoperations were needed. Endoscopic biopsy seems to be an accurate procedure with acceptable morbidity and mortality rates.</description><identifier>ISSN: 0022-3085</identifier><identifier>EISSN: 1933-0693</identifier><identifier>DOI: 10.3171/2014.9.JNS132648</identifier><identifier>PMID: 25361487</identifier><language>eng</language><publisher>United States</publisher><subject>Adolescent ; Adult ; Aged ; Biopsy - adverse effects ; Biopsy - methods ; Biopsy - statistics &amp; numerical data ; Brain Neoplasms - pathology ; Cerebral Ventricle Neoplasms - pathology ; Child ; Endoscopy - methods ; Female ; Humans ; Male ; Middle Aged ; Neuroendoscopy - methods ; Neurosecretory Systems - pathology ; Reproducibility of Results ; Retrospective Studies ; Young Adult</subject><ispartof>Journal of neurosurgery, 2015-01, Vol.122 (1), p.34-39</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c407t-c902267574fa2f76c9421282d96a331fc941e22bbb04a1e7da856ad77a80abf53</citedby><cites>FETCH-LOGICAL-c407t-c902267574fa2f76c9421282d96a331fc941e22bbb04a1e7da856ad77a80abf53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25361487$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Giannetti, Alexandre Varella</creatorcontrib><creatorcontrib>Alvarenga, Alexandre Yugo Holayama</creatorcontrib><creatorcontrib>de Lima, Thiago Oliveira Lemos</creatorcontrib><creatorcontrib>Pedrosa, Hugo Abi-Sáber Rodrigues</creatorcontrib><creatorcontrib>Souweidane, Mark M</creatorcontrib><title>Neuroendoscopic biopsy of brain lesions: accuracy and complications</title><title>Journal of neurosurgery</title><addtitle>J Neurosurg</addtitle><description>The authors conducted a study to analyze the accuracy of neuroendoscopic biopsies of ventricular and periventricular lesions and record any difficulties or complications of the neuroendoscopic biopsy procedure. A total of 50 patients with different diseases consecutively underwent endoscopic biopsy procedures. The biopsy result was considered diagnostic if the pathologist reported any specific finding on which clinicians could base decisions about treatment or observation. The biopsy result was referred to as accurate if the results matched results of a sample obtained later or if the treatment response and disease evolution were compatible with the diagnosis. The biopsy result was considered inaccurate if results showed any relevant differences from those of the later sample or if the patient's disease did not evolve as expected. Complications were recorded and compared with those found in a literature review. For 2 patients, the procedure had to be terminated. The biopsy diagnostic rate was 89.6%, and the accuracy rate was 86%. Complications associated with the procedure were 3 hemorrhages (6%), 2 infections (4%), and 1 death (2%); no reoperations were needed. Endoscopic biopsy seems to be an accurate procedure with acceptable morbidity and mortality rates.</description><subject>Adolescent</subject><subject>Adult</subject><subject>Aged</subject><subject>Biopsy - adverse effects</subject><subject>Biopsy - methods</subject><subject>Biopsy - statistics &amp; numerical data</subject><subject>Brain Neoplasms - pathology</subject><subject>Cerebral Ventricle Neoplasms - pathology</subject><subject>Child</subject><subject>Endoscopy - methods</subject><subject>Female</subject><subject>Humans</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Neuroendoscopy - methods</subject><subject>Neurosecretory Systems - pathology</subject><subject>Reproducibility of Results</subject><subject>Retrospective Studies</subject><subject>Young Adult</subject><issn>0022-3085</issn><issn>1933-0693</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kEtPwzAQhC0EoqVw54Ry5JLiV_zghiqeqsoBOFtrx5aCkjjYzaH_nlSFnlarnRntfAhdE7xkRJI7iglf6uXb5oMwKrg6QXOiGSux0OwUzTGmtGRYVTN0kfM3xkRwQc_RjFZMEK7kHK02fkzR93XMLg6NK2wTh7wrYihsgqYvWp-b2Of7ApwbE7hdAX1duNgNbeNgu79dorMAbfZXf3OBvp4eP1cv5fr9-XX1sC4dx3JbOj29I2QleQAapHCaU0IVrbUAxkiYduIptdZiDsTLGlQloJYSFAYbKrZAt4fcIcWf0eet6ZrsfNtC7-OYzdSOqErxik5SfJC6FHNOPpghNR2knSHY7NGZPTqjzRHdZLn5Sx9t5-uj4Z8V-wVsRmlE</recordid><startdate>201501</startdate><enddate>201501</enddate><creator>Giannetti, Alexandre Varella</creator><creator>Alvarenga, Alexandre Yugo Holayama</creator><creator>de Lima, Thiago Oliveira Lemos</creator><creator>Pedrosa, Hugo Abi-Sáber Rodrigues</creator><creator>Souweidane, Mark M</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201501</creationdate><title>Neuroendoscopic biopsy of brain lesions: accuracy and complications</title><author>Giannetti, Alexandre Varella ; Alvarenga, Alexandre Yugo Holayama ; de Lima, Thiago Oliveira Lemos ; Pedrosa, Hugo Abi-Sáber Rodrigues ; Souweidane, Mark M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c407t-c902267574fa2f76c9421282d96a331fc941e22bbb04a1e7da856ad77a80abf53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Adolescent</topic><topic>Adult</topic><topic>Aged</topic><topic>Biopsy - adverse effects</topic><topic>Biopsy - methods</topic><topic>Biopsy - statistics &amp; numerical data</topic><topic>Brain Neoplasms - pathology</topic><topic>Cerebral Ventricle Neoplasms - pathology</topic><topic>Child</topic><topic>Endoscopy - methods</topic><topic>Female</topic><topic>Humans</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Neuroendoscopy - methods</topic><topic>Neurosecretory Systems - pathology</topic><topic>Reproducibility of Results</topic><topic>Retrospective Studies</topic><topic>Young Adult</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Giannetti, Alexandre Varella</creatorcontrib><creatorcontrib>Alvarenga, Alexandre Yugo Holayama</creatorcontrib><creatorcontrib>de Lima, Thiago Oliveira Lemos</creatorcontrib><creatorcontrib>Pedrosa, Hugo Abi-Sáber Rodrigues</creatorcontrib><creatorcontrib>Souweidane, Mark M</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of neurosurgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Giannetti, Alexandre Varella</au><au>Alvarenga, Alexandre Yugo Holayama</au><au>de Lima, Thiago Oliveira Lemos</au><au>Pedrosa, Hugo Abi-Sáber Rodrigues</au><au>Souweidane, Mark M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Neuroendoscopic biopsy of brain lesions: accuracy and complications</atitle><jtitle>Journal of neurosurgery</jtitle><addtitle>J Neurosurg</addtitle><date>2015-01</date><risdate>2015</risdate><volume>122</volume><issue>1</issue><spage>34</spage><epage>39</epage><pages>34-39</pages><issn>0022-3085</issn><eissn>1933-0693</eissn><abstract>The authors conducted a study to analyze the accuracy of neuroendoscopic biopsies of ventricular and periventricular lesions and record any difficulties or complications of the neuroendoscopic biopsy procedure. A total of 50 patients with different diseases consecutively underwent endoscopic biopsy procedures. The biopsy result was considered diagnostic if the pathologist reported any specific finding on which clinicians could base decisions about treatment or observation. The biopsy result was referred to as accurate if the results matched results of a sample obtained later or if the treatment response and disease evolution were compatible with the diagnosis. The biopsy result was considered inaccurate if results showed any relevant differences from those of the later sample or if the patient's disease did not evolve as expected. Complications were recorded and compared with those found in a literature review. For 2 patients, the procedure had to be terminated. The biopsy diagnostic rate was 89.6%, and the accuracy rate was 86%. Complications associated with the procedure were 3 hemorrhages (6%), 2 infections (4%), and 1 death (2%); no reoperations were needed. Endoscopic biopsy seems to be an accurate procedure with acceptable morbidity and mortality rates.</abstract><cop>United States</cop><pmid>25361487</pmid><doi>10.3171/2014.9.JNS132648</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0022-3085
ispartof Journal of neurosurgery, 2015-01, Vol.122 (1), p.34-39
issn 0022-3085
1933-0693
language eng
recordid cdi_proquest_miscellaneous_1641858452
source MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects Adolescent
Adult
Aged
Biopsy - adverse effects
Biopsy - methods
Biopsy - statistics & numerical data
Brain Neoplasms - pathology
Cerebral Ventricle Neoplasms - pathology
Child
Endoscopy - methods
Female
Humans
Male
Middle Aged
Neuroendoscopy - methods
Neurosecretory Systems - pathology
Reproducibility of Results
Retrospective Studies
Young Adult
title Neuroendoscopic biopsy of brain lesions: accuracy and complications
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-11T14%3A32%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Neuroendoscopic%20biopsy%20of%20brain%20lesions:%20accuracy%20and%20complications&rft.jtitle=Journal%20of%20neurosurgery&rft.au=Giannetti,%20Alexandre%20Varella&rft.date=2015-01&rft.volume=122&rft.issue=1&rft.spage=34&rft.epage=39&rft.pages=34-39&rft.issn=0022-3085&rft.eissn=1933-0693&rft_id=info:doi/10.3171/2014.9.JNS132648&rft_dat=%3Cproquest_cross%3E1641858452%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1641858452&rft_id=info:pmid/25361487&rfr_iscdi=true