Buffy coat volume reduction for optimization of leucapheresis harvests produced by the autoMNC program

Background and Objectives Buffy coat (BC) volume reduction was evaluated in leucapheresis (LA) harvests due to the target monocyte yield and the red blood cell (RBC) content. A packed erythrocyte volume (PEV) of 7·5 ml should not be exceeded to avoid RBC debulking with loss of leucocytes (WBCs) and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Vox sanguinis 2015-01, Vol.108 (1), p.89-95
Hauptverfasser: Burk, S., Erdmann, M., Weiss, D., Eckstein, R., Strasser, E. F.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 95
container_issue 1
container_start_page 89
container_title Vox sanguinis
container_volume 108
creator Burk, S.
Erdmann, M.
Weiss, D.
Eckstein, R.
Strasser, E. F.
description Background and Objectives Buffy coat (BC) volume reduction was evaluated in leucapheresis (LA) harvests due to the target monocyte yield and the red blood cell (RBC) content. A packed erythrocyte volume (PEV) of 7·5 ml should not be exceeded to avoid RBC debulking with loss of leucocytes (WBCs) and the monocyte fraction during monocyte counterflow elutriation, a next step of monocyte enrichment prior to cell culture. Materials and Methods Two hundred and fifty‐three 5‐l leucaphereses (autoMNC program) performed in 102 healthy blood donors (24 female and 78 male donors) were retrospectively analysed. Different categories of BC volumes were compared due to the quality of the LA products measured by blood counts and flow cytometry. Results Collection of maximum BC volume of 10 ml and more each collection cycle (product volume: 169 ± 21 ml) resulted in 1·58 ± 0·41 × 10e9 CD14+ monocytes and high volume of packed erythrocyte (18·4 ± 8·8 ml). Low BC volume collection below 6 ml each collection cycle produced only 1·07 ± 0·40 × 10e9 CD14+ monocytes but reduced PEV significantly by 64% (6·7 ± 4·1 ml). Conclusion By reduction of the BC volume, the PEV in LA products could be reduced, which is a precondition for counterflow elutriation of monocytes. A BC volume between 7 and 8 ml per collection cycle should be adjusted to reduce PEV to 7·5 ml without relevant monocyte loss.
doi_str_mv 10.1111/vox.12202
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1639496166</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3532670441</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3912-1a1849b48dc3e0c1675458f1e80fdd960680f5acff928a8f02bb1fe556808c653</originalsourceid><addsrcrecordid>eNp1kEtv1DAUhS0EotPCgj-ALLGhi7TXzzhLGKA8SishHhUby3FsJiUZD3Y8dPj1eDptF0jcja-OvnN8dRB6QuCIlDleh6sjQinQe2hGOGUVcAL30QyA06oBqPfQfkqXAKCoEg_RHhWMcQA6Q_5l9n6DbTATXochjw5H12U79WGJfYg4rKZ-7P-YayF4PLhszWrhokt9wgsT1y5NCa9iKC7X4XaDp4XDJk_h49l8q_-IZnyEHngzJPf45j1AX968_jx_W52en7ybvzitLGsIrYghijctV51lDiyRteBCeeIU-K5rJMiyCGO9b6gyygNtW-KdEEVXVgp2gJ7vcsu_v3K5TI99sm4YzNKFnDSRrOGNJFIW9Nk_6GXIcVmu21KqJjVptoGHO8rGkFJ0Xq9iP5q40QT0tnxdytfX5Rf26U1ibkfX3ZG3bRfgeAf87ge3-X-S_np-cRtZ7Rx9mtzVncPEn1rWrBb629mJZuL9q--fLj5ozv4ChiOdlQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1638717195</pqid></control><display><type>article</type><title>Buffy coat volume reduction for optimization of leucapheresis harvests produced by the autoMNC program</title><source>MEDLINE</source><source>Wiley Online Library All Journals</source><creator>Burk, S. ; Erdmann, M. ; Weiss, D. ; Eckstein, R. ; Strasser, E. F.</creator><creatorcontrib>Burk, S. ; Erdmann, M. ; Weiss, D. ; Eckstein, R. ; Strasser, E. F.</creatorcontrib><description>Background and Objectives Buffy coat (BC) volume reduction was evaluated in leucapheresis (LA) harvests due to the target monocyte yield and the red blood cell (RBC) content. A packed erythrocyte volume (PEV) of 7·5 ml should not be exceeded to avoid RBC debulking with loss of leucocytes (WBCs) and the monocyte fraction during monocyte counterflow elutriation, a next step of monocyte enrichment prior to cell culture. Materials and Methods Two hundred and fifty‐three 5‐l leucaphereses (autoMNC program) performed in 102 healthy blood donors (24 female and 78 male donors) were retrospectively analysed. Different categories of BC volumes were compared due to the quality of the LA products measured by blood counts and flow cytometry. Results Collection of maximum BC volume of 10 ml and more each collection cycle (product volume: 169 ± 21 ml) resulted in 1·58 ± 0·41 × 10e9 CD14+ monocytes and high volume of packed erythrocyte (18·4 ± 8·8 ml). Low BC volume collection below 6 ml each collection cycle produced only 1·07 ± 0·40 × 10e9 CD14+ monocytes but reduced PEV significantly by 64% (6·7 ± 4·1 ml). Conclusion By reduction of the BC volume, the PEV in LA products could be reduced, which is a precondition for counterflow elutriation of monocytes. A BC volume between 7 and 8 ml per collection cycle should be adjusted to reduce PEV to 7·5 ml without relevant monocyte loss.</description><identifier>ISSN: 0042-9007</identifier><identifier>EISSN: 1423-0410</identifier><identifier>DOI: 10.1111/vox.12202</identifier><identifier>PMID: 25334002</identifier><identifier>CODEN: VOSAAD</identifier><language>eng</language><publisher>England: Blackwell Publishing Ltd</publisher><subject>apheresis ; Blood Buffy Coat - cytology ; Blood Buffy Coat - immunology ; Blood diseases ; cellular therapy ; component production ; Erythrocytes ; Female ; Hematocrit ; Hematology ; Humans ; Leukapheresis - methods ; Leukapheresis - standards ; Leukocytes ; Male</subject><ispartof>Vox sanguinis, 2015-01, Vol.108 (1), p.89-95</ispartof><rights>2014 International Society of Blood Transfusion</rights><rights>2014 International Society of Blood Transfusion.</rights><rights>Copyright Vox Sanguinis © 2015 International Society of Blood Transfusion</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3912-1a1849b48dc3e0c1675458f1e80fdd960680f5acff928a8f02bb1fe556808c653</citedby><cites>FETCH-LOGICAL-c3912-1a1849b48dc3e0c1675458f1e80fdd960680f5acff928a8f02bb1fe556808c653</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1111%2Fvox.12202$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1111%2Fvox.12202$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,27924,27925,45574,45575</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25334002$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Burk, S.</creatorcontrib><creatorcontrib>Erdmann, M.</creatorcontrib><creatorcontrib>Weiss, D.</creatorcontrib><creatorcontrib>Eckstein, R.</creatorcontrib><creatorcontrib>Strasser, E. F.</creatorcontrib><title>Buffy coat volume reduction for optimization of leucapheresis harvests produced by the autoMNC program</title><title>Vox sanguinis</title><addtitle>Vox Sang</addtitle><description>Background and Objectives Buffy coat (BC) volume reduction was evaluated in leucapheresis (LA) harvests due to the target monocyte yield and the red blood cell (RBC) content. A packed erythrocyte volume (PEV) of 7·5 ml should not be exceeded to avoid RBC debulking with loss of leucocytes (WBCs) and the monocyte fraction during monocyte counterflow elutriation, a next step of monocyte enrichment prior to cell culture. Materials and Methods Two hundred and fifty‐three 5‐l leucaphereses (autoMNC program) performed in 102 healthy blood donors (24 female and 78 male donors) were retrospectively analysed. Different categories of BC volumes were compared due to the quality of the LA products measured by blood counts and flow cytometry. Results Collection of maximum BC volume of 10 ml and more each collection cycle (product volume: 169 ± 21 ml) resulted in 1·58 ± 0·41 × 10e9 CD14+ monocytes and high volume of packed erythrocyte (18·4 ± 8·8 ml). Low BC volume collection below 6 ml each collection cycle produced only 1·07 ± 0·40 × 10e9 CD14+ monocytes but reduced PEV significantly by 64% (6·7 ± 4·1 ml). Conclusion By reduction of the BC volume, the PEV in LA products could be reduced, which is a precondition for counterflow elutriation of monocytes. A BC volume between 7 and 8 ml per collection cycle should be adjusted to reduce PEV to 7·5 ml without relevant monocyte loss.</description><subject>apheresis</subject><subject>Blood Buffy Coat - cytology</subject><subject>Blood Buffy Coat - immunology</subject><subject>Blood diseases</subject><subject>cellular therapy</subject><subject>component production</subject><subject>Erythrocytes</subject><subject>Female</subject><subject>Hematocrit</subject><subject>Hematology</subject><subject>Humans</subject><subject>Leukapheresis - methods</subject><subject>Leukapheresis - standards</subject><subject>Leukocytes</subject><subject>Male</subject><issn>0042-9007</issn><issn>1423-0410</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kEtv1DAUhS0EotPCgj-ALLGhi7TXzzhLGKA8SishHhUby3FsJiUZD3Y8dPj1eDptF0jcja-OvnN8dRB6QuCIlDleh6sjQinQe2hGOGUVcAL30QyA06oBqPfQfkqXAKCoEg_RHhWMcQA6Q_5l9n6DbTATXochjw5H12U79WGJfYg4rKZ-7P-YayF4PLhszWrhokt9wgsT1y5NCa9iKC7X4XaDp4XDJk_h49l8q_-IZnyEHngzJPf45j1AX968_jx_W52en7ybvzitLGsIrYghijctV51lDiyRteBCeeIU-K5rJMiyCGO9b6gyygNtW-KdEEVXVgp2gJ7vcsu_v3K5TI99sm4YzNKFnDSRrOGNJFIW9Nk_6GXIcVmu21KqJjVptoGHO8rGkFJ0Xq9iP5q40QT0tnxdytfX5Rf26U1ibkfX3ZG3bRfgeAf87ge3-X-S_np-cRtZ7Rx9mtzVncPEn1rWrBb629mJZuL9q--fLj5ozv4ChiOdlQ</recordid><startdate>201501</startdate><enddate>201501</enddate><creator>Burk, S.</creator><creator>Erdmann, M.</creator><creator>Weiss, D.</creator><creator>Eckstein, R.</creator><creator>Strasser, E. F.</creator><general>Blackwell Publishing Ltd</general><general>S. Karger AG</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QL</scope><scope>7T5</scope><scope>7TM</scope><scope>7U9</scope><scope>C1K</scope><scope>H94</scope><scope>K9.</scope><scope>M7N</scope><scope>7X8</scope></search><sort><creationdate>201501</creationdate><title>Buffy coat volume reduction for optimization of leucapheresis harvests produced by the autoMNC program</title><author>Burk, S. ; Erdmann, M. ; Weiss, D. ; Eckstein, R. ; Strasser, E. F.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3912-1a1849b48dc3e0c1675458f1e80fdd960680f5acff928a8f02bb1fe556808c653</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>apheresis</topic><topic>Blood Buffy Coat - cytology</topic><topic>Blood Buffy Coat - immunology</topic><topic>Blood diseases</topic><topic>cellular therapy</topic><topic>component production</topic><topic>Erythrocytes</topic><topic>Female</topic><topic>Hematocrit</topic><topic>Hematology</topic><topic>Humans</topic><topic>Leukapheresis - methods</topic><topic>Leukapheresis - standards</topic><topic>Leukocytes</topic><topic>Male</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Burk, S.</creatorcontrib><creatorcontrib>Erdmann, M.</creatorcontrib><creatorcontrib>Weiss, D.</creatorcontrib><creatorcontrib>Eckstein, R.</creatorcontrib><creatorcontrib>Strasser, E. F.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Bacteriology Abstracts (Microbiology B)</collection><collection>Immunology Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Algology Mycology and Protozoology Abstracts (Microbiology C)</collection><collection>MEDLINE - Academic</collection><jtitle>Vox sanguinis</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Burk, S.</au><au>Erdmann, M.</au><au>Weiss, D.</au><au>Eckstein, R.</au><au>Strasser, E. F.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Buffy coat volume reduction for optimization of leucapheresis harvests produced by the autoMNC program</atitle><jtitle>Vox sanguinis</jtitle><addtitle>Vox Sang</addtitle><date>2015-01</date><risdate>2015</risdate><volume>108</volume><issue>1</issue><spage>89</spage><epage>95</epage><pages>89-95</pages><issn>0042-9007</issn><eissn>1423-0410</eissn><coden>VOSAAD</coden><abstract>Background and Objectives Buffy coat (BC) volume reduction was evaluated in leucapheresis (LA) harvests due to the target monocyte yield and the red blood cell (RBC) content. A packed erythrocyte volume (PEV) of 7·5 ml should not be exceeded to avoid RBC debulking with loss of leucocytes (WBCs) and the monocyte fraction during monocyte counterflow elutriation, a next step of monocyte enrichment prior to cell culture. Materials and Methods Two hundred and fifty‐three 5‐l leucaphereses (autoMNC program) performed in 102 healthy blood donors (24 female and 78 male donors) were retrospectively analysed. Different categories of BC volumes were compared due to the quality of the LA products measured by blood counts and flow cytometry. Results Collection of maximum BC volume of 10 ml and more each collection cycle (product volume: 169 ± 21 ml) resulted in 1·58 ± 0·41 × 10e9 CD14+ monocytes and high volume of packed erythrocyte (18·4 ± 8·8 ml). Low BC volume collection below 6 ml each collection cycle produced only 1·07 ± 0·40 × 10e9 CD14+ monocytes but reduced PEV significantly by 64% (6·7 ± 4·1 ml). Conclusion By reduction of the BC volume, the PEV in LA products could be reduced, which is a precondition for counterflow elutriation of monocytes. A BC volume between 7 and 8 ml per collection cycle should be adjusted to reduce PEV to 7·5 ml without relevant monocyte loss.</abstract><cop>England</cop><pub>Blackwell Publishing Ltd</pub><pmid>25334002</pmid><doi>10.1111/vox.12202</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0042-9007
ispartof Vox sanguinis, 2015-01, Vol.108 (1), p.89-95
issn 0042-9007
1423-0410
language eng
recordid cdi_proquest_miscellaneous_1639496166
source MEDLINE; Wiley Online Library All Journals
subjects apheresis
Blood Buffy Coat - cytology
Blood Buffy Coat - immunology
Blood diseases
cellular therapy
component production
Erythrocytes
Female
Hematocrit
Hematology
Humans
Leukapheresis - methods
Leukapheresis - standards
Leukocytes
Male
title Buffy coat volume reduction for optimization of leucapheresis harvests produced by the autoMNC program
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T18%3A13%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Buffy%20coat%20volume%20reduction%20for%20optimization%20of%20leucapheresis%20harvests%20produced%20by%20the%20autoMNC%20program&rft.jtitle=Vox%20sanguinis&rft.au=Burk,%20S.&rft.date=2015-01&rft.volume=108&rft.issue=1&rft.spage=89&rft.epage=95&rft.pages=89-95&rft.issn=0042-9007&rft.eissn=1423-0410&rft.coden=VOSAAD&rft_id=info:doi/10.1111/vox.12202&rft_dat=%3Cproquest_cross%3E3532670441%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1638717195&rft_id=info:pmid/25334002&rfr_iscdi=true