Hematological values for adult eastern Hermann’s tortoise (Testudo hermanni boettgeri) in semi-natural conditions
Hermann’s tortoise (Testudo hermanni) is considered near threatened in the wild but, by contrast, it is one of the most popular pet tortoises in Europe. Scant data is reported in the veterinary literature on hematological values for T. hermanni and, to our knowledge, none focused on the subspecies b...
Gespeichert in:
Veröffentlicht in: | Journal of veterinary diagnostic investigation 2015-01, Vol.27 (1), p.68-73 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 73 |
---|---|
container_issue | 1 |
container_start_page | 68 |
container_title | Journal of veterinary diagnostic investigation |
container_volume | 27 |
creator | Bielli, Mattia Nardini, Giordano Di Girolamo, Nicola Savarino, Paolo |
description | Hermann’s tortoise (Testudo hermanni) is considered near threatened in the wild but, by contrast, it is one of the most popular pet tortoises in Europe. Scant data is reported in the veterinary literature on hematological values for T. hermanni and, to our knowledge, none focused on the subspecies boettgeri (eastern Hermann’s tortoise). Published reports are based on small sample populations, and confusion arises when comparing the sampling sites, the anticoagulants, and the counting methods used. The purpose of the current study was to establish the normal mean values and reference intervals for the main hematological parameters for captive adult T. hermanni boettgeri and to evaluate the reliability of a semiautomated blood analyzer for red blood cell count and hematocrit determination. Blood values were determined in 23 adult tortoises using a Neubauer chamber with Natt and Herrick solution; red blood cells and hematocrit were also measured using a semiautomated blood analyzer. Statistical analysis included descriptive statistics, differences between sexes, and agreement between the counting methods. Reference intervals were calculated with the robust method. Wilcoxon signed rank test with continuity correction was used to investigate differences between sexes, and Bland–Altman analysis was performed to compare manual versus semiautomated values. Red blood cells, hematocrit, and hemoglobin determinations were significantly higher in males than in females. White blood cell counts did not show any sex variability. The agreement of manual versus semiautomated determination was considered acceptable for clinical use. |
doi_str_mv | 10.1177/1040638714561251 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1639489582</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_1040638714561251</sage_id><sourcerecordid>1639489582</sourcerecordid><originalsourceid>FETCH-LOGICAL-c379t-1eeecf990b4b98813b48ab83d8b9ee3594b61a024dec29ab7020f651031d03c63</originalsourceid><addsrcrecordid>eNp1kL1KBDEUhYMorq72VpJSi9HcSeYnpYi6gmCz1kMyc2fNMpNokhHsfA1fzycxsmohWN0D5zsH7iHkCNgZQFWdAxOs5HUFoighL2CL7IEUPBOSl9tJJzv78mdkP4Q1Y0VeVLBLZnmRFAi2R8ICRxXd4FamVQN9UcOEgfbOU9VNQ6SoQkRv6QL9qKz9eHsPNDofnQlIT5YY4tQ5-rhxDdUOY1yhN6fUWBpwNJlVcfKpunW2M9E4Gw7ITq-GgIffd04erq-Wl4vs7v7m9vLiLmt5JWMGiNj2UjIttKxr4FrUSte8q7VE5IUUugTFctFhm0ulK5azviyAcegYb0s-Jyeb3ifvntNbsRlNaHEYlEU3hQZKLkUtizpPKNugrXcheOybJ29G5V8bYM3X1M3fqVPk-Lt90iN2v4GfbROQbYCgVtis3eRt-vb_wk8uXYiB</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1639489582</pqid></control><display><type>article</type><title>Hematological values for adult eastern Hermann’s tortoise (Testudo hermanni boettgeri) in semi-natural conditions</title><source>MEDLINE</source><source>SAGE Complete A-Z List</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Alma/SFX Local Collection</source><creator>Bielli, Mattia ; Nardini, Giordano ; Di Girolamo, Nicola ; Savarino, Paolo</creator><creatorcontrib>Bielli, Mattia ; Nardini, Giordano ; Di Girolamo, Nicola ; Savarino, Paolo</creatorcontrib><description>Hermann’s tortoise (Testudo hermanni) is considered near threatened in the wild but, by contrast, it is one of the most popular pet tortoises in Europe. Scant data is reported in the veterinary literature on hematological values for T. hermanni and, to our knowledge, none focused on the subspecies boettgeri (eastern Hermann’s tortoise). Published reports are based on small sample populations, and confusion arises when comparing the sampling sites, the anticoagulants, and the counting methods used. The purpose of the current study was to establish the normal mean values and reference intervals for the main hematological parameters for captive adult T. hermanni boettgeri and to evaluate the reliability of a semiautomated blood analyzer for red blood cell count and hematocrit determination. Blood values were determined in 23 adult tortoises using a Neubauer chamber with Natt and Herrick solution; red blood cells and hematocrit were also measured using a semiautomated blood analyzer. Statistical analysis included descriptive statistics, differences between sexes, and agreement between the counting methods. Reference intervals were calculated with the robust method. Wilcoxon signed rank test with continuity correction was used to investigate differences between sexes, and Bland–Altman analysis was performed to compare manual versus semiautomated values. Red blood cells, hematocrit, and hemoglobin determinations were significantly higher in males than in females. White blood cell counts did not show any sex variability. The agreement of manual versus semiautomated determination was considered acceptable for clinical use.</description><identifier>ISSN: 1040-6387</identifier><identifier>EISSN: 1943-4936</identifier><identifier>DOI: 10.1177/1040638714561251</identifier><identifier>PMID: 25525140</identifier><language>eng</language><publisher>Los Angeles, CA: SAGE Publications</publisher><subject>Animals ; Blood Cell Count - veterinary ; Female ; Hematologic Tests - veterinary ; Italy ; Male ; Reference Values ; Turtles - blood</subject><ispartof>Journal of veterinary diagnostic investigation, 2015-01, Vol.27 (1), p.68-73</ispartof><rights>2014 The Author(s)</rights><rights>2014 The Author(s).</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c379t-1eeecf990b4b98813b48ab83d8b9ee3594b61a024dec29ab7020f651031d03c63</citedby><cites>FETCH-LOGICAL-c379t-1eeecf990b4b98813b48ab83d8b9ee3594b61a024dec29ab7020f651031d03c63</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/1040638714561251$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/1040638714561251$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,777,781,21800,27905,27906,43602,43603</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25525140$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Bielli, Mattia</creatorcontrib><creatorcontrib>Nardini, Giordano</creatorcontrib><creatorcontrib>Di Girolamo, Nicola</creatorcontrib><creatorcontrib>Savarino, Paolo</creatorcontrib><title>Hematological values for adult eastern Hermann’s tortoise (Testudo hermanni boettgeri) in semi-natural conditions</title><title>Journal of veterinary diagnostic investigation</title><addtitle>J Vet Diagn Invest</addtitle><description>Hermann’s tortoise (Testudo hermanni) is considered near threatened in the wild but, by contrast, it is one of the most popular pet tortoises in Europe. Scant data is reported in the veterinary literature on hematological values for T. hermanni and, to our knowledge, none focused on the subspecies boettgeri (eastern Hermann’s tortoise). Published reports are based on small sample populations, and confusion arises when comparing the sampling sites, the anticoagulants, and the counting methods used. The purpose of the current study was to establish the normal mean values and reference intervals for the main hematological parameters for captive adult T. hermanni boettgeri and to evaluate the reliability of a semiautomated blood analyzer for red blood cell count and hematocrit determination. Blood values were determined in 23 adult tortoises using a Neubauer chamber with Natt and Herrick solution; red blood cells and hematocrit were also measured using a semiautomated blood analyzer. Statistical analysis included descriptive statistics, differences between sexes, and agreement between the counting methods. Reference intervals were calculated with the robust method. Wilcoxon signed rank test with continuity correction was used to investigate differences between sexes, and Bland–Altman analysis was performed to compare manual versus semiautomated values. Red blood cells, hematocrit, and hemoglobin determinations were significantly higher in males than in females. White blood cell counts did not show any sex variability. The agreement of manual versus semiautomated determination was considered acceptable for clinical use.</description><subject>Animals</subject><subject>Blood Cell Count - veterinary</subject><subject>Female</subject><subject>Hematologic Tests - veterinary</subject><subject>Italy</subject><subject>Male</subject><subject>Reference Values</subject><subject>Turtles - blood</subject><issn>1040-6387</issn><issn>1943-4936</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kL1KBDEUhYMorq72VpJSi9HcSeYnpYi6gmCz1kMyc2fNMpNokhHsfA1fzycxsmohWN0D5zsH7iHkCNgZQFWdAxOs5HUFoighL2CL7IEUPBOSl9tJJzv78mdkP4Q1Y0VeVLBLZnmRFAi2R8ICRxXd4FamVQN9UcOEgfbOU9VNQ6SoQkRv6QL9qKz9eHsPNDofnQlIT5YY4tQ5-rhxDdUOY1yhN6fUWBpwNJlVcfKpunW2M9E4Gw7ITq-GgIffd04erq-Wl4vs7v7m9vLiLmt5JWMGiNj2UjIttKxr4FrUSte8q7VE5IUUugTFctFhm0ulK5azviyAcegYb0s-Jyeb3ifvntNbsRlNaHEYlEU3hQZKLkUtizpPKNugrXcheOybJ29G5V8bYM3X1M3fqVPk-Lt90iN2v4GfbROQbYCgVtis3eRt-vb_wk8uXYiB</recordid><startdate>20150101</startdate><enddate>20150101</enddate><creator>Bielli, Mattia</creator><creator>Nardini, Giordano</creator><creator>Di Girolamo, Nicola</creator><creator>Savarino, Paolo</creator><general>SAGE Publications</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20150101</creationdate><title>Hematological values for adult eastern Hermann’s tortoise (Testudo hermanni boettgeri) in semi-natural conditions</title><author>Bielli, Mattia ; Nardini, Giordano ; Di Girolamo, Nicola ; Savarino, Paolo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c379t-1eeecf990b4b98813b48ab83d8b9ee3594b61a024dec29ab7020f651031d03c63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Animals</topic><topic>Blood Cell Count - veterinary</topic><topic>Female</topic><topic>Hematologic Tests - veterinary</topic><topic>Italy</topic><topic>Male</topic><topic>Reference Values</topic><topic>Turtles - blood</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bielli, Mattia</creatorcontrib><creatorcontrib>Nardini, Giordano</creatorcontrib><creatorcontrib>Di Girolamo, Nicola</creatorcontrib><creatorcontrib>Savarino, Paolo</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of veterinary diagnostic investigation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bielli, Mattia</au><au>Nardini, Giordano</au><au>Di Girolamo, Nicola</au><au>Savarino, Paolo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Hematological values for adult eastern Hermann’s tortoise (Testudo hermanni boettgeri) in semi-natural conditions</atitle><jtitle>Journal of veterinary diagnostic investigation</jtitle><addtitle>J Vet Diagn Invest</addtitle><date>2015-01-01</date><risdate>2015</risdate><volume>27</volume><issue>1</issue><spage>68</spage><epage>73</epage><pages>68-73</pages><issn>1040-6387</issn><eissn>1943-4936</eissn><abstract>Hermann’s tortoise (Testudo hermanni) is considered near threatened in the wild but, by contrast, it is one of the most popular pet tortoises in Europe. Scant data is reported in the veterinary literature on hematological values for T. hermanni and, to our knowledge, none focused on the subspecies boettgeri (eastern Hermann’s tortoise). Published reports are based on small sample populations, and confusion arises when comparing the sampling sites, the anticoagulants, and the counting methods used. The purpose of the current study was to establish the normal mean values and reference intervals for the main hematological parameters for captive adult T. hermanni boettgeri and to evaluate the reliability of a semiautomated blood analyzer for red blood cell count and hematocrit determination. Blood values were determined in 23 adult tortoises using a Neubauer chamber with Natt and Herrick solution; red blood cells and hematocrit were also measured using a semiautomated blood analyzer. Statistical analysis included descriptive statistics, differences between sexes, and agreement between the counting methods. Reference intervals were calculated with the robust method. Wilcoxon signed rank test with continuity correction was used to investigate differences between sexes, and Bland–Altman analysis was performed to compare manual versus semiautomated values. Red blood cells, hematocrit, and hemoglobin determinations were significantly higher in males than in females. White blood cell counts did not show any sex variability. The agreement of manual versus semiautomated determination was considered acceptable for clinical use.</abstract><cop>Los Angeles, CA</cop><pub>SAGE Publications</pub><pmid>25525140</pmid><doi>10.1177/1040638714561251</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1040-6387 |
ispartof | Journal of veterinary diagnostic investigation, 2015-01, Vol.27 (1), p.68-73 |
issn | 1040-6387 1943-4936 |
language | eng |
recordid | cdi_proquest_miscellaneous_1639489582 |
source | MEDLINE; SAGE Complete A-Z List; EZB-FREE-00999 freely available EZB journals; Alma/SFX Local Collection |
subjects | Animals Blood Cell Count - veterinary Female Hematologic Tests - veterinary Italy Male Reference Values Turtles - blood |
title | Hematological values for adult eastern Hermann’s tortoise (Testudo hermanni boettgeri) in semi-natural conditions |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-21T05%3A13%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Hematological%20values%20for%20adult%20eastern%20Hermann%E2%80%99s%20tortoise%20(Testudo%20hermanni%20boettgeri)%20in%20semi-natural%20conditions&rft.jtitle=Journal%20of%20veterinary%20diagnostic%20investigation&rft.au=Bielli,%20Mattia&rft.date=2015-01-01&rft.volume=27&rft.issue=1&rft.spage=68&rft.epage=73&rft.pages=68-73&rft.issn=1040-6387&rft.eissn=1943-4936&rft_id=info:doi/10.1177/1040638714561251&rft_dat=%3Cproquest_cross%3E1639489582%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1639489582&rft_id=info:pmid/25525140&rft_sage_id=10.1177_1040638714561251&rfr_iscdi=true |