Gas chromatography coupled to mass spectrometry analysis of volatiles, sugars, organic acids and aminoacids in Valencia Late orange juice and reliability of the Automated Mass Spectral Deconvolution and Identification System for their automatic identification and quantification

► Volatile and polar compounds of orange juices were analyzed by GC–MS. ► AMDIS settings and MS operational parameters were appropriately optimized. ► Accuracy of automated AMDIS analysis was corroborated by manual data processing. ► AMDIS analysis is valid to perform multiple metabolite determinati...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Chromatography A 2012-06, Vol.1241, p.84-95
Hauptverfasser: Cerdán-Calero, Manuela, Sendra, José María, Sentandreu, Enrique
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 95
container_issue
container_start_page 84
container_title Journal of Chromatography A
container_volume 1241
creator Cerdán-Calero, Manuela
Sendra, José María
Sentandreu, Enrique
description ► Volatile and polar compounds of orange juices were analyzed by GC–MS. ► AMDIS settings and MS operational parameters were appropriately optimized. ► Accuracy of automated AMDIS analysis was corroborated by manual data processing. ► AMDIS analysis is valid to perform multiple metabolite determinations. Neutral volatiles and non-volatile polar compounds (sugars, organics acids and aminoacids) present in Valencia Late orange juice have been analysed by Gas Chromatography coupled to Mass Spectrometry (GC–MS). Before analysis, the neutral volatiles have been extracted by Headspace-Solid Phase Microextraction (HS-SPME), and the non-volatile polar compounds have been transformed to their corresponding volatile trimethylsilyl (TMS) derivatives. From the resulting raw GC–MS data files, the reliability of the Automated Mass Spectral Deconvolution and Identification System (AMDIS) to perform accurate identification and quantification of the compounds present in the sample has been tested. Hence, both raw GC–MS data files have been processed automatically by using AMDIS and manually by using Xcalibur™, the manufacturer's data processing software for the GC–MS platform used. Results indicate that the reliability of AMDIS for accurate identification and quantification of the compounds present in the sample strongly depends on a number of operational settings, for both the MS and AMDIS, which must be optimized for the particular type of assayed sample. After optimization of these settings, AMDIS and Xcalibur™ yield practically the same results. A total of 85 volatiles and 22 polar compounds have been identified and quantified in Valencia Late orange juice.
doi_str_mv 10.1016/j.chroma.2012.04.014
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1635019309</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0021967312005560</els_id><sourcerecordid>1635019309</sourcerecordid><originalsourceid>FETCH-LOGICAL-c419t-b7e2be4c51b0ad58e6807001c089faffa1de1932dc4a53b20960da4b24ff1573</originalsourceid><addsrcrecordid>eNp9kkFv1DAQhQMC0aVw5YTAxx7YxXaSTXJBqgotlRZx2MLVmtiT3Vkl8dZ2KuXf42wKggunkUffvHmemSR5K_hKcLH-eFjpvbMdrCQXcsWzFRfZ02QhyiJdpkVRPksWnEuxrNZFepa89P7AuSh4IV8kZ1LmaVrxYvHkzQ14NgsFu3Nw3I9M2-HYomHBsg68Z_6IOkQCgxsZ9NCOnjyzDXuwLQRq0X9gftiBi9G6HfSkGWgyPsKGQUe9nZ_Us5_QYq8J2AYCRhr6HbLDQBpPsMOWoKaWwjg1CHtkl0OYzEU_3yYz25MZaNln1LaPDoZAtj8V3xrsAzWk4ZTajj5gxxrrJh1yDGal6I7-Jafi-wH-Sr1KnjfQenz9GM-Tu-svd1dfl5vvN7dXl5ulzkQVlnWBssZM56LmYPIS1yUv4pg1L6sGmgaEQVGl0ugM8rSWvFpzA1kts6YReZGeJxez7NHZ-wF9UB15jW0LPdrBK7FOcx4FeBXRbEa1s947bNTRUQduVIKr6SDUQc17VNNBKJ6peBCx7N1jh6Hu0Pwp-n0BEXg_Aw1YBTtHXv3YRoU8fqOsZMYj8WkmMA7igdAprykuEQ25uAtlLP3fwy9lj9pr</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1635019309</pqid></control><display><type>article</type><title>Gas chromatography coupled to mass spectrometry analysis of volatiles, sugars, organic acids and aminoacids in Valencia Late orange juice and reliability of the Automated Mass Spectral Deconvolution and Identification System for their automatic identification and quantification</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Cerdán-Calero, Manuela ; Sendra, José María ; Sentandreu, Enrique</creator><creatorcontrib>Cerdán-Calero, Manuela ; Sendra, José María ; Sentandreu, Enrique</creatorcontrib><description>► Volatile and polar compounds of orange juices were analyzed by GC–MS. ► AMDIS settings and MS operational parameters were appropriately optimized. ► Accuracy of automated AMDIS analysis was corroborated by manual data processing. ► AMDIS analysis is valid to perform multiple metabolite determinations. Neutral volatiles and non-volatile polar compounds (sugars, organics acids and aminoacids) present in Valencia Late orange juice have been analysed by Gas Chromatography coupled to Mass Spectrometry (GC–MS). Before analysis, the neutral volatiles have been extracted by Headspace-Solid Phase Microextraction (HS-SPME), and the non-volatile polar compounds have been transformed to their corresponding volatile trimethylsilyl (TMS) derivatives. From the resulting raw GC–MS data files, the reliability of the Automated Mass Spectral Deconvolution and Identification System (AMDIS) to perform accurate identification and quantification of the compounds present in the sample has been tested. Hence, both raw GC–MS data files have been processed automatically by using AMDIS and manually by using Xcalibur™, the manufacturer's data processing software for the GC–MS platform used. Results indicate that the reliability of AMDIS for accurate identification and quantification of the compounds present in the sample strongly depends on a number of operational settings, for both the MS and AMDIS, which must be optimized for the particular type of assayed sample. After optimization of these settings, AMDIS and Xcalibur™ yield practically the same results. A total of 85 volatiles and 22 polar compounds have been identified and quantified in Valencia Late orange juice.</description><identifier>ISSN: 0021-9673</identifier><identifier>EISSN: 1873-3778</identifier><identifier>DOI: 10.1016/j.chroma.2012.04.014</identifier><identifier>PMID: 22533907</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>AMDIS ; Amino Acids - analysis ; Beverages - analysis ; Carbohydrates - analysis ; Citrus sinensis - chemistry ; computer software ; gas chromatography ; Gas Chromatography-Mass Spectrometry - methods ; Gas Chromatography-Mass Spectrometry - standards ; GC–MS ; headspace analysis ; mass spectrometry ; Metabolite profiling ; Odorants - analysis ; Orange juice ; organic acids and salts ; Organic Chemicals - analysis ; polar compounds ; Reproducibility of Results ; Solid Phase Microextraction ; sugars ; TMS derivatives ; Volatile compounds</subject><ispartof>Journal of Chromatography A, 2012-06, Vol.1241, p.84-95</ispartof><rights>2012 Elsevier B.V.</rights><rights>Copyright © 2012 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c419t-b7e2be4c51b0ad58e6807001c089faffa1de1932dc4a53b20960da4b24ff1573</citedby><cites>FETCH-LOGICAL-c419t-b7e2be4c51b0ad58e6807001c089faffa1de1932dc4a53b20960da4b24ff1573</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0021967312005560$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/22533907$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Cerdán-Calero, Manuela</creatorcontrib><creatorcontrib>Sendra, José María</creatorcontrib><creatorcontrib>Sentandreu, Enrique</creatorcontrib><title>Gas chromatography coupled to mass spectrometry analysis of volatiles, sugars, organic acids and aminoacids in Valencia Late orange juice and reliability of the Automated Mass Spectral Deconvolution and Identification System for their automatic identification and quantification</title><title>Journal of Chromatography A</title><addtitle>J Chromatogr A</addtitle><description>► Volatile and polar compounds of orange juices were analyzed by GC–MS. ► AMDIS settings and MS operational parameters were appropriately optimized. ► Accuracy of automated AMDIS analysis was corroborated by manual data processing. ► AMDIS analysis is valid to perform multiple metabolite determinations. Neutral volatiles and non-volatile polar compounds (sugars, organics acids and aminoacids) present in Valencia Late orange juice have been analysed by Gas Chromatography coupled to Mass Spectrometry (GC–MS). Before analysis, the neutral volatiles have been extracted by Headspace-Solid Phase Microextraction (HS-SPME), and the non-volatile polar compounds have been transformed to their corresponding volatile trimethylsilyl (TMS) derivatives. From the resulting raw GC–MS data files, the reliability of the Automated Mass Spectral Deconvolution and Identification System (AMDIS) to perform accurate identification and quantification of the compounds present in the sample has been tested. Hence, both raw GC–MS data files have been processed automatically by using AMDIS and manually by using Xcalibur™, the manufacturer's data processing software for the GC–MS platform used. Results indicate that the reliability of AMDIS for accurate identification and quantification of the compounds present in the sample strongly depends on a number of operational settings, for both the MS and AMDIS, which must be optimized for the particular type of assayed sample. After optimization of these settings, AMDIS and Xcalibur™ yield practically the same results. A total of 85 volatiles and 22 polar compounds have been identified and quantified in Valencia Late orange juice.</description><subject>AMDIS</subject><subject>Amino Acids - analysis</subject><subject>Beverages - analysis</subject><subject>Carbohydrates - analysis</subject><subject>Citrus sinensis - chemistry</subject><subject>computer software</subject><subject>gas chromatography</subject><subject>Gas Chromatography-Mass Spectrometry - methods</subject><subject>Gas Chromatography-Mass Spectrometry - standards</subject><subject>GC–MS</subject><subject>headspace analysis</subject><subject>mass spectrometry</subject><subject>Metabolite profiling</subject><subject>Odorants - analysis</subject><subject>Orange juice</subject><subject>organic acids and salts</subject><subject>Organic Chemicals - analysis</subject><subject>polar compounds</subject><subject>Reproducibility of Results</subject><subject>Solid Phase Microextraction</subject><subject>sugars</subject><subject>TMS derivatives</subject><subject>Volatile compounds</subject><issn>0021-9673</issn><issn>1873-3778</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kkFv1DAQhQMC0aVw5YTAxx7YxXaSTXJBqgotlRZx2MLVmtiT3Vkl8dZ2KuXf42wKggunkUffvHmemSR5K_hKcLH-eFjpvbMdrCQXcsWzFRfZ02QhyiJdpkVRPksWnEuxrNZFepa89P7AuSh4IV8kZ1LmaVrxYvHkzQ14NgsFu3Nw3I9M2-HYomHBsg68Z_6IOkQCgxsZ9NCOnjyzDXuwLQRq0X9gftiBi9G6HfSkGWgyPsKGQUe9nZ_Us5_QYq8J2AYCRhr6HbLDQBpPsMOWoKaWwjg1CHtkl0OYzEU_3yYz25MZaNln1LaPDoZAtj8V3xrsAzWk4ZTajj5gxxrrJh1yDGal6I7-Jafi-wH-Sr1KnjfQenz9GM-Tu-svd1dfl5vvN7dXl5ulzkQVlnWBssZM56LmYPIS1yUv4pg1L6sGmgaEQVGl0ugM8rSWvFpzA1kts6YReZGeJxez7NHZ-wF9UB15jW0LPdrBK7FOcx4FeBXRbEa1s947bNTRUQduVIKr6SDUQc17VNNBKJ6peBCx7N1jh6Hu0Pwp-n0BEXg_Aw1YBTtHXv3YRoU8fqOsZMYj8WkmMA7igdAprykuEQ25uAtlLP3fwy9lj9pr</recordid><startdate>20120608</startdate><enddate>20120608</enddate><creator>Cerdán-Calero, Manuela</creator><creator>Sendra, José María</creator><creator>Sentandreu, Enrique</creator><general>Elsevier B.V</general><scope>FBQ</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QH</scope><scope>7UA</scope><scope>C1K</scope><scope>F1W</scope><scope>H97</scope><scope>L.G</scope></search><sort><creationdate>20120608</creationdate><title>Gas chromatography coupled to mass spectrometry analysis of volatiles, sugars, organic acids and aminoacids in Valencia Late orange juice and reliability of the Automated Mass Spectral Deconvolution and Identification System for their automatic identification and quantification</title><author>Cerdán-Calero, Manuela ; Sendra, José María ; Sentandreu, Enrique</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c419t-b7e2be4c51b0ad58e6807001c089faffa1de1932dc4a53b20960da4b24ff1573</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>AMDIS</topic><topic>Amino Acids - analysis</topic><topic>Beverages - analysis</topic><topic>Carbohydrates - analysis</topic><topic>Citrus sinensis - chemistry</topic><topic>computer software</topic><topic>gas chromatography</topic><topic>Gas Chromatography-Mass Spectrometry - methods</topic><topic>Gas Chromatography-Mass Spectrometry - standards</topic><topic>GC–MS</topic><topic>headspace analysis</topic><topic>mass spectrometry</topic><topic>Metabolite profiling</topic><topic>Odorants - analysis</topic><topic>Orange juice</topic><topic>organic acids and salts</topic><topic>Organic Chemicals - analysis</topic><topic>polar compounds</topic><topic>Reproducibility of Results</topic><topic>Solid Phase Microextraction</topic><topic>sugars</topic><topic>TMS derivatives</topic><topic>Volatile compounds</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cerdán-Calero, Manuela</creatorcontrib><creatorcontrib>Sendra, José María</creatorcontrib><creatorcontrib>Sentandreu, Enrique</creatorcontrib><collection>AGRIS</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Aqualine</collection><collection>Water Resources Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ASFA: Aquatic Sciences and Fisheries Abstracts</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) 3: Aquatic Pollution &amp; Environmental Quality</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) Professional</collection><jtitle>Journal of Chromatography A</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cerdán-Calero, Manuela</au><au>Sendra, José María</au><au>Sentandreu, Enrique</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Gas chromatography coupled to mass spectrometry analysis of volatiles, sugars, organic acids and aminoacids in Valencia Late orange juice and reliability of the Automated Mass Spectral Deconvolution and Identification System for their automatic identification and quantification</atitle><jtitle>Journal of Chromatography A</jtitle><addtitle>J Chromatogr A</addtitle><date>2012-06-08</date><risdate>2012</risdate><volume>1241</volume><spage>84</spage><epage>95</epage><pages>84-95</pages><issn>0021-9673</issn><eissn>1873-3778</eissn><abstract>► Volatile and polar compounds of orange juices were analyzed by GC–MS. ► AMDIS settings and MS operational parameters were appropriately optimized. ► Accuracy of automated AMDIS analysis was corroborated by manual data processing. ► AMDIS analysis is valid to perform multiple metabolite determinations. Neutral volatiles and non-volatile polar compounds (sugars, organics acids and aminoacids) present in Valencia Late orange juice have been analysed by Gas Chromatography coupled to Mass Spectrometry (GC–MS). Before analysis, the neutral volatiles have been extracted by Headspace-Solid Phase Microextraction (HS-SPME), and the non-volatile polar compounds have been transformed to their corresponding volatile trimethylsilyl (TMS) derivatives. From the resulting raw GC–MS data files, the reliability of the Automated Mass Spectral Deconvolution and Identification System (AMDIS) to perform accurate identification and quantification of the compounds present in the sample has been tested. Hence, both raw GC–MS data files have been processed automatically by using AMDIS and manually by using Xcalibur™, the manufacturer's data processing software for the GC–MS platform used. Results indicate that the reliability of AMDIS for accurate identification and quantification of the compounds present in the sample strongly depends on a number of operational settings, for both the MS and AMDIS, which must be optimized for the particular type of assayed sample. After optimization of these settings, AMDIS and Xcalibur™ yield practically the same results. A total of 85 volatiles and 22 polar compounds have been identified and quantified in Valencia Late orange juice.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>22533907</pmid><doi>10.1016/j.chroma.2012.04.014</doi><tpages>12</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0021-9673
ispartof Journal of Chromatography A, 2012-06, Vol.1241, p.84-95
issn 0021-9673
1873-3778
language eng
recordid cdi_proquest_miscellaneous_1635019309
source MEDLINE; Elsevier ScienceDirect Journals
subjects AMDIS
Amino Acids - analysis
Beverages - analysis
Carbohydrates - analysis
Citrus sinensis - chemistry
computer software
gas chromatography
Gas Chromatography-Mass Spectrometry - methods
Gas Chromatography-Mass Spectrometry - standards
GC–MS
headspace analysis
mass spectrometry
Metabolite profiling
Odorants - analysis
Orange juice
organic acids and salts
Organic Chemicals - analysis
polar compounds
Reproducibility of Results
Solid Phase Microextraction
sugars
TMS derivatives
Volatile compounds
title Gas chromatography coupled to mass spectrometry analysis of volatiles, sugars, organic acids and aminoacids in Valencia Late orange juice and reliability of the Automated Mass Spectral Deconvolution and Identification System for their automatic identification and quantification
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T06%3A56%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Gas%20chromatography%20coupled%20to%20mass%20spectrometry%20analysis%20of%20volatiles,%20sugars,%20organic%20acids%20and%20aminoacids%20in%20Valencia%20Late%20orange%20juice%20and%20reliability%20of%20the%20Automated%20Mass%20Spectral%20Deconvolution%20and%20Identification%20System%20for%20their%20automatic%20identification%20and%20quantification&rft.jtitle=Journal%20of%20Chromatography%20A&rft.au=Cerd%C3%A1n-Calero,%20Manuela&rft.date=2012-06-08&rft.volume=1241&rft.spage=84&rft.epage=95&rft.pages=84-95&rft.issn=0021-9673&rft.eissn=1873-3778&rft_id=info:doi/10.1016/j.chroma.2012.04.014&rft_dat=%3Cproquest_cross%3E1635019309%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1635019309&rft_id=info:pmid/22533907&rft_els_id=S0021967312005560&rfr_iscdi=true