Biological activated carbon in fluidized bed reactors for the treatment of groundwater contaminated with volatile aromatic hydrocarbons

A comparison of fluidized bed reactor systems with (1) adsorptive removal capacity only using granular activated carbon (GAC) without microbial growth, (2) combined biological and adsorptive removal mechanisms using GAC with microbial growth and (3) biological removal only using nonactivated carbon...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Water research (Oxford) 1992, Vol.26 (10), p.1389-1401
Hauptverfasser: Voice, Thomas C., Pak, Daewon, Zhao, Xianda, Shi, Jing, Hickey, Robert F.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1401
container_issue 10
container_start_page 1389
container_title Water research (Oxford)
container_volume 26
creator Voice, Thomas C.
Pak, Daewon
Zhao, Xianda
Shi, Jing
Hickey, Robert F.
description A comparison of fluidized bed reactor systems with (1) adsorptive removal capacity only using granular activated carbon (GAC) without microbial growth, (2) combined biological and adsorptive removal mechanisms using GAC with microbial growth and (3) biological removal only using nonactivated carbon with microbial growth was performed. These three systems were fed groundwater contaminated with benzene, toluene and xylene (BTX). The breakthrough profiles, steady-state removal of BTX and system responses to step increases in applied organic loading rates were investigated. During start-up, even though the same amount of inoculum was added to the two biological systems, the time required until effective biodegradation commenced in the system employing GAC as a biomass carrier was less than that observed for the system using non-activated carbon (200 vs 500 h). Significantly less BTX was released during this period by the system with combined removal mechanisms and the development of a contiguous biofilm was more rapid. Under constant, steady state, organic loading conditions (3 and 6 kg-COD/m 3-day), BTX removals were similar for the two biological systems, although the system employing the GAC carrier had lower effluent concentrations at the lower loading rate. More than 90% of the BTX were removed in both systems. During step increases in organic loading, however, the combination of biological and adsorptive removal capacity resulted in enhanced BTX removal and more stable operation. Scanning electron microscopy was used to examine the extent of surface coverage of the GAC and non-activated carbon by the biofilm. Particles from both systems were observed to be completely covered by a contiguous, thick biofilm.
doi_str_mv 10.1016/0043-1354(92)90132-N
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_16326423</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>004313549290132N</els_id><sourcerecordid>16326423</sourcerecordid><originalsourceid>FETCH-LOGICAL-a418t-2f0a5dbf5144cf6622eb729b32544a8406080ff70b60c81e809a31256e19e9dc3</originalsourceid><addsrcrecordid>eNqFkc9OHDEMxqOqSN1C36CHHCpUDtM6f2Z2cqlUUKFICC5wjjIZh001k0CSXURfgNdulkUcy8GyZf38Wf5MyGcG3xiw7juAFA0Trfyq-JECJnhz-Y4sWL9UDZeyf08Wr8gH8jHnPwDAuVAL8nTs4xRvvTUTNbb4jSk4UmvSEAP1gbpp7Uf_t_aGGgkrE1OmLiZaVkhL7ZQZQ6HR0dsU12F8qAqJ2hiKmX14lnvwZUU3cTLFT0hNinOtLF09jinuVuUDsufMlPHTS94nN6e_rk9-NxdXZ-cnPy8aI1lfGu7AtOPgWialdV3HOQ5LrgbBWylNL6GDHpxbwtCB7Rn2oIxgvO2QKVSjFfvkcKd7l-L9GnPRs88Wp8kEjOusWSd4J7l4GxRLUIz3FZQ70KaYc0Kn75KfTXrUDPT2PXrrvd56rxXXz-_Rl3Xsy4u-ydV8l0ywPr_Otq2Q9aSK_dhhWE3ZeEw6W4_B4ugT2qLH6P-_5x9iNaYY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>13709128</pqid></control><display><type>article</type><title>Biological activated carbon in fluidized bed reactors for the treatment of groundwater contaminated with volatile aromatic hydrocarbons</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>Voice, Thomas C. ; Pak, Daewon ; Zhao, Xianda ; Shi, Jing ; Hickey, Robert F.</creator><creatorcontrib>Voice, Thomas C. ; Pak, Daewon ; Zhao, Xianda ; Shi, Jing ; Hickey, Robert F.</creatorcontrib><description>A comparison of fluidized bed reactor systems with (1) adsorptive removal capacity only using granular activated carbon (GAC) without microbial growth, (2) combined biological and adsorptive removal mechanisms using GAC with microbial growth and (3) biological removal only using nonactivated carbon with microbial growth was performed. These three systems were fed groundwater contaminated with benzene, toluene and xylene (BTX). The breakthrough profiles, steady-state removal of BTX and system responses to step increases in applied organic loading rates were investigated. During start-up, even though the same amount of inoculum was added to the two biological systems, the time required until effective biodegradation commenced in the system employing GAC as a biomass carrier was less than that observed for the system using non-activated carbon (200 vs 500 h). Significantly less BTX was released during this period by the system with combined removal mechanisms and the development of a contiguous biofilm was more rapid. Under constant, steady state, organic loading conditions (3 and 6 kg-COD/m 3-day), BTX removals were similar for the two biological systems, although the system employing the GAC carrier had lower effluent concentrations at the lower loading rate. More than 90% of the BTX were removed in both systems. During step increases in organic loading, however, the combination of biological and adsorptive removal capacity resulted in enhanced BTX removal and more stable operation. Scanning electron microscopy was used to examine the extent of surface coverage of the GAC and non-activated carbon by the biofilm. Particles from both systems were observed to be completely covered by a contiguous, thick biofilm.</description><identifier>ISSN: 0043-1354</identifier><identifier>EISSN: 1879-2448</identifier><identifier>DOI: 10.1016/0043-1354(92)90132-N</identifier><identifier>CODEN: WATRAG</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>adsorption ; Applied sciences ; benzene ; biodegradation ; biofilm ; biological activated carbon ; BTX ; Exact sciences and technology ; fluidized bed reactor ; groundwater treatment ; Groundwaters ; Natural water pollution ; Pollution ; scanning electron microscopy ; toluene ; Water treatment and pollution ; xylene</subject><ispartof>Water research (Oxford), 1992, Vol.26 (10), p.1389-1401</ispartof><rights>1992</rights><rights>1992 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a418t-2f0a5dbf5144cf6622eb729b32544a8406080ff70b60c81e809a31256e19e9dc3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/0043-1354(92)90132-N$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,778,782,3539,4012,27906,27907,27908,45978</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=5534544$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Voice, Thomas C.</creatorcontrib><creatorcontrib>Pak, Daewon</creatorcontrib><creatorcontrib>Zhao, Xianda</creatorcontrib><creatorcontrib>Shi, Jing</creatorcontrib><creatorcontrib>Hickey, Robert F.</creatorcontrib><title>Biological activated carbon in fluidized bed reactors for the treatment of groundwater contaminated with volatile aromatic hydrocarbons</title><title>Water research (Oxford)</title><description>A comparison of fluidized bed reactor systems with (1) adsorptive removal capacity only using granular activated carbon (GAC) without microbial growth, (2) combined biological and adsorptive removal mechanisms using GAC with microbial growth and (3) biological removal only using nonactivated carbon with microbial growth was performed. These three systems were fed groundwater contaminated with benzene, toluene and xylene (BTX). The breakthrough profiles, steady-state removal of BTX and system responses to step increases in applied organic loading rates were investigated. During start-up, even though the same amount of inoculum was added to the two biological systems, the time required until effective biodegradation commenced in the system employing GAC as a biomass carrier was less than that observed for the system using non-activated carbon (200 vs 500 h). Significantly less BTX was released during this period by the system with combined removal mechanisms and the development of a contiguous biofilm was more rapid. Under constant, steady state, organic loading conditions (3 and 6 kg-COD/m 3-day), BTX removals were similar for the two biological systems, although the system employing the GAC carrier had lower effluent concentrations at the lower loading rate. More than 90% of the BTX were removed in both systems. During step increases in organic loading, however, the combination of biological and adsorptive removal capacity resulted in enhanced BTX removal and more stable operation. Scanning electron microscopy was used to examine the extent of surface coverage of the GAC and non-activated carbon by the biofilm. Particles from both systems were observed to be completely covered by a contiguous, thick biofilm.</description><subject>adsorption</subject><subject>Applied sciences</subject><subject>benzene</subject><subject>biodegradation</subject><subject>biofilm</subject><subject>biological activated carbon</subject><subject>BTX</subject><subject>Exact sciences and technology</subject><subject>fluidized bed reactor</subject><subject>groundwater treatment</subject><subject>Groundwaters</subject><subject>Natural water pollution</subject><subject>Pollution</subject><subject>scanning electron microscopy</subject><subject>toluene</subject><subject>Water treatment and pollution</subject><subject>xylene</subject><issn>0043-1354</issn><issn>1879-2448</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1992</creationdate><recordtype>article</recordtype><recordid>eNqFkc9OHDEMxqOqSN1C36CHHCpUDtM6f2Z2cqlUUKFICC5wjjIZh001k0CSXURfgNdulkUcy8GyZf38Wf5MyGcG3xiw7juAFA0Trfyq-JECJnhz-Y4sWL9UDZeyf08Wr8gH8jHnPwDAuVAL8nTs4xRvvTUTNbb4jSk4UmvSEAP1gbpp7Uf_t_aGGgkrE1OmLiZaVkhL7ZQZQ6HR0dsU12F8qAqJ2hiKmX14lnvwZUU3cTLFT0hNinOtLF09jinuVuUDsufMlPHTS94nN6e_rk9-NxdXZ-cnPy8aI1lfGu7AtOPgWialdV3HOQ5LrgbBWylNL6GDHpxbwtCB7Rn2oIxgvO2QKVSjFfvkcKd7l-L9GnPRs88Wp8kEjOusWSd4J7l4GxRLUIz3FZQ70KaYc0Kn75KfTXrUDPT2PXrrvd56rxXXz-_Rl3Xsy4u-ydV8l0ywPr_Otq2Q9aSK_dhhWE3ZeEw6W4_B4ugT2qLH6P-_5x9iNaYY</recordid><startdate>1992</startdate><enddate>1992</enddate><creator>Voice, Thomas C.</creator><creator>Pak, Daewon</creator><creator>Zhao, Xianda</creator><creator>Shi, Jing</creator><creator>Hickey, Robert F.</creator><general>Elsevier Ltd</general><general>Elsevier Science</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QH</scope><scope>7TV</scope><scope>C1K</scope><scope>F1W</scope><scope>H97</scope><scope>L.G</scope></search><sort><creationdate>1992</creationdate><title>Biological activated carbon in fluidized bed reactors for the treatment of groundwater contaminated with volatile aromatic hydrocarbons</title><author>Voice, Thomas C. ; Pak, Daewon ; Zhao, Xianda ; Shi, Jing ; Hickey, Robert F.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a418t-2f0a5dbf5144cf6622eb729b32544a8406080ff70b60c81e809a31256e19e9dc3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1992</creationdate><topic>adsorption</topic><topic>Applied sciences</topic><topic>benzene</topic><topic>biodegradation</topic><topic>biofilm</topic><topic>biological activated carbon</topic><topic>BTX</topic><topic>Exact sciences and technology</topic><topic>fluidized bed reactor</topic><topic>groundwater treatment</topic><topic>Groundwaters</topic><topic>Natural water pollution</topic><topic>Pollution</topic><topic>scanning electron microscopy</topic><topic>toluene</topic><topic>Water treatment and pollution</topic><topic>xylene</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Voice, Thomas C.</creatorcontrib><creatorcontrib>Pak, Daewon</creatorcontrib><creatorcontrib>Zhao, Xianda</creatorcontrib><creatorcontrib>Shi, Jing</creatorcontrib><creatorcontrib>Hickey, Robert F.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Aqualine</collection><collection>Pollution Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ASFA: Aquatic Sciences and Fisheries Abstracts</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) 3: Aquatic Pollution &amp; Environmental Quality</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) Professional</collection><jtitle>Water research (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Voice, Thomas C.</au><au>Pak, Daewon</au><au>Zhao, Xianda</au><au>Shi, Jing</au><au>Hickey, Robert F.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Biological activated carbon in fluidized bed reactors for the treatment of groundwater contaminated with volatile aromatic hydrocarbons</atitle><jtitle>Water research (Oxford)</jtitle><date>1992</date><risdate>1992</risdate><volume>26</volume><issue>10</issue><spage>1389</spage><epage>1401</epage><pages>1389-1401</pages><issn>0043-1354</issn><eissn>1879-2448</eissn><coden>WATRAG</coden><abstract>A comparison of fluidized bed reactor systems with (1) adsorptive removal capacity only using granular activated carbon (GAC) without microbial growth, (2) combined biological and adsorptive removal mechanisms using GAC with microbial growth and (3) biological removal only using nonactivated carbon with microbial growth was performed. These three systems were fed groundwater contaminated with benzene, toluene and xylene (BTX). The breakthrough profiles, steady-state removal of BTX and system responses to step increases in applied organic loading rates were investigated. During start-up, even though the same amount of inoculum was added to the two biological systems, the time required until effective biodegradation commenced in the system employing GAC as a biomass carrier was less than that observed for the system using non-activated carbon (200 vs 500 h). Significantly less BTX was released during this period by the system with combined removal mechanisms and the development of a contiguous biofilm was more rapid. Under constant, steady state, organic loading conditions (3 and 6 kg-COD/m 3-day), BTX removals were similar for the two biological systems, although the system employing the GAC carrier had lower effluent concentrations at the lower loading rate. More than 90% of the BTX were removed in both systems. During step increases in organic loading, however, the combination of biological and adsorptive removal capacity resulted in enhanced BTX removal and more stable operation. Scanning electron microscopy was used to examine the extent of surface coverage of the GAC and non-activated carbon by the biofilm. Particles from both systems were observed to be completely covered by a contiguous, thick biofilm.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><doi>10.1016/0043-1354(92)90132-N</doi><tpages>13</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0043-1354
ispartof Water research (Oxford), 1992, Vol.26 (10), p.1389-1401
issn 0043-1354
1879-2448
language eng
recordid cdi_proquest_miscellaneous_16326423
source ScienceDirect Journals (5 years ago - present)
subjects adsorption
Applied sciences
benzene
biodegradation
biofilm
biological activated carbon
BTX
Exact sciences and technology
fluidized bed reactor
groundwater treatment
Groundwaters
Natural water pollution
Pollution
scanning electron microscopy
toluene
Water treatment and pollution
xylene
title Biological activated carbon in fluidized bed reactors for the treatment of groundwater contaminated with volatile aromatic hydrocarbons
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T15%3A49%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Biological%20activated%20carbon%20in%20fluidized%20bed%20reactors%20for%20the%20treatment%20of%20groundwater%20contaminated%20with%20volatile%20aromatic%20hydrocarbons&rft.jtitle=Water%20research%20(Oxford)&rft.au=Voice,%20Thomas%20C.&rft.date=1992&rft.volume=26&rft.issue=10&rft.spage=1389&rft.epage=1401&rft.pages=1389-1401&rft.issn=0043-1354&rft.eissn=1879-2448&rft.coden=WATRAG&rft_id=info:doi/10.1016/0043-1354(92)90132-N&rft_dat=%3Cproquest_cross%3E16326423%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=13709128&rft_id=info:pmid/&rft_els_id=004313549290132N&rfr_iscdi=true