Interlaboratory Comparison of the Co−C Eutectic Point with Small-Size Cell for Thermocouples
SUMMARY Using a small‐size crucible, interlaboratory comparison of the realization of the Co−C eutectic point was performed in the industrial field in Japan, with the aim of verifying the possibility of thermocouple calibration at the eutectic point with an existing furnace of less‐than‐ideal temper...
Gespeichert in:
Veröffentlicht in: | Electronics and communications in Japan 2014-07, Vol.97 (7), p.48-54 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 54 |
---|---|
container_issue | 7 |
container_start_page | 48 |
container_title | Electronics and communications in Japan |
container_volume | 97 |
creator | Numajiri, Haruhiko Sasaki, Masashi Aikawa, Takao Sato, Hiroyasu Kimura, Kazuhiro Yamasaki, Haruki Ishii, Juntaro Yamada, Yoshiro |
description | SUMMARY
Using a small‐size crucible, interlaboratory comparison of the realization of the Co−C eutectic point was performed in the industrial field in Japan, with the aim of verifying the possibility of thermocouple calibration at the eutectic point with an existing furnace of less‐than‐ideal temperature distribution, namely, the palladium‐point wire‐bridge method furnace for thermocouple calibration. A small‐size crucible for thermocouples was made by the National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (NMIJ/AIST). The interlaboratory comparison was piloted by the Tokyo Metropolitan Industrial Technology Research Institute (TIRI), a public test and research organization in Tokyo, and was conducted among five calibration laboratories including the pilot. One of the five laboratories is a designated calibration laboratory in Japan, and the other three are private laboratories. Four laboratories including TIRI used an existing palladium‐point furnace, and one laboratory made a new furnace for this interlaboratory comparison. |
doi_str_mv | 10.1002/ecj.11583 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1629363753</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1629363753</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3003-e3c4f392f58b5ab45acff3c60989e54bbf9296dfbe59e972a8e1daca6bda4df83</originalsourceid><addsrcrecordid>eNp1kMFOAjEQhhujiYgefIMe9bDQbneX7dGsiBCiJmC82XTLNBR3KbYliE_g2Uf0SVxFvXmayeT7ZyYfQqeUdCghcRfUokNpmrM91KI8iSOeJnT_r2fsEB15vyAkS9KEtdDjcBnAVbK0Tgbrtriw9Uo64-0SW43DHJrJx9t7gfvrACoYhe-sWQa8MWGOJ7WsqmhiXhsKqgpr6_B0Dq62yq5XFfhjdKBl5eHkp7bR_VV_WlxH49vBsLgYR4oRwiJgKtGMxzrNy1SWSSqV1kxlhOcc0qQsNY95NtMlpBx4L5Y50JlUMitnMpnpnLXR2W7vytnnNfggauNV85Jcgl17QbOYs4z1GgFtdL5DlbPeO9Bi5Uwt3VZQIr4cisah-HbYsN0duzEVbP8HRb8Y_SaiXcL4AC9_CemeRNZr7ouHm4EY53RUXJKRyNknDQCEXw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1629363753</pqid></control><display><type>article</type><title>Interlaboratory Comparison of the Co−C Eutectic Point with Small-Size Cell for Thermocouples</title><source>Wiley Online Library Journals Frontfile Complete</source><source>Business Source Complete</source><creator>Numajiri, Haruhiko ; Sasaki, Masashi ; Aikawa, Takao ; Sato, Hiroyasu ; Kimura, Kazuhiro ; Yamasaki, Haruki ; Ishii, Juntaro ; Yamada, Yoshiro</creator><creatorcontrib>Numajiri, Haruhiko ; Sasaki, Masashi ; Aikawa, Takao ; Sato, Hiroyasu ; Kimura, Kazuhiro ; Yamasaki, Haruki ; Ishii, Juntaro ; Yamada, Yoshiro</creatorcontrib><description>SUMMARY
Using a small‐size crucible, interlaboratory comparison of the realization of the Co−C eutectic point was performed in the industrial field in Japan, with the aim of verifying the possibility of thermocouple calibration at the eutectic point with an existing furnace of less‐than‐ideal temperature distribution, namely, the palladium‐point wire‐bridge method furnace for thermocouple calibration. A small‐size crucible for thermocouples was made by the National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (NMIJ/AIST). The interlaboratory comparison was piloted by the Tokyo Metropolitan Industrial Technology Research Institute (TIRI), a public test and research organization in Tokyo, and was conducted among five calibration laboratories including the pilot. One of the five laboratories is a designated calibration laboratory in Japan, and the other three are private laboratories. Four laboratories including TIRI used an existing palladium‐point furnace, and one laboratory made a new furnace for this interlaboratory comparison.</description><identifier>ISSN: 1942-9533</identifier><identifier>EISSN: 1942-9541</identifier><identifier>DOI: 10.1002/ecj.11583</identifier><language>eng</language><publisher>Blackwell Publishing Ltd</publisher><subject>Calibration ; Eutectic temperature ; fixed-point calibration ; Furnaces ; Interlaboratory ; interlaboratory comparison ; metal-carbon eutectic point ; Metrology ; Pilots ; small-size cell ; Temperature distribution ; thermocouple ; Thermocouples</subject><ispartof>Electronics and communications in Japan, 2014-07, Vol.97 (7), p.48-54</ispartof><rights>2014 Wiley Periodicals, Inc.</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c3003-e3c4f392f58b5ab45acff3c60989e54bbf9296dfbe59e972a8e1daca6bda4df83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fecj.11583$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fecj.11583$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,777,781,1412,27905,27906,45555,45556</link.rule.ids></links><search><creatorcontrib>Numajiri, Haruhiko</creatorcontrib><creatorcontrib>Sasaki, Masashi</creatorcontrib><creatorcontrib>Aikawa, Takao</creatorcontrib><creatorcontrib>Sato, Hiroyasu</creatorcontrib><creatorcontrib>Kimura, Kazuhiro</creatorcontrib><creatorcontrib>Yamasaki, Haruki</creatorcontrib><creatorcontrib>Ishii, Juntaro</creatorcontrib><creatorcontrib>Yamada, Yoshiro</creatorcontrib><title>Interlaboratory Comparison of the Co−C Eutectic Point with Small-Size Cell for Thermocouples</title><title>Electronics and communications in Japan</title><addtitle>Electron Comm Jpn</addtitle><description>SUMMARY
Using a small‐size crucible, interlaboratory comparison of the realization of the Co−C eutectic point was performed in the industrial field in Japan, with the aim of verifying the possibility of thermocouple calibration at the eutectic point with an existing furnace of less‐than‐ideal temperature distribution, namely, the palladium‐point wire‐bridge method furnace for thermocouple calibration. A small‐size crucible for thermocouples was made by the National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (NMIJ/AIST). The interlaboratory comparison was piloted by the Tokyo Metropolitan Industrial Technology Research Institute (TIRI), a public test and research organization in Tokyo, and was conducted among five calibration laboratories including the pilot. One of the five laboratories is a designated calibration laboratory in Japan, and the other three are private laboratories. Four laboratories including TIRI used an existing palladium‐point furnace, and one laboratory made a new furnace for this interlaboratory comparison.</description><subject>Calibration</subject><subject>Eutectic temperature</subject><subject>fixed-point calibration</subject><subject>Furnaces</subject><subject>Interlaboratory</subject><subject>interlaboratory comparison</subject><subject>metal-carbon eutectic point</subject><subject>Metrology</subject><subject>Pilots</subject><subject>small-size cell</subject><subject>Temperature distribution</subject><subject>thermocouple</subject><subject>Thermocouples</subject><issn>1942-9533</issn><issn>1942-9541</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNp1kMFOAjEQhhujiYgefIMe9bDQbneX7dGsiBCiJmC82XTLNBR3KbYliE_g2Uf0SVxFvXmayeT7ZyYfQqeUdCghcRfUokNpmrM91KI8iSOeJnT_r2fsEB15vyAkS9KEtdDjcBnAVbK0Tgbrtriw9Uo64-0SW43DHJrJx9t7gfvrACoYhe-sWQa8MWGOJ7WsqmhiXhsKqgpr6_B0Dq62yq5XFfhjdKBl5eHkp7bR_VV_WlxH49vBsLgYR4oRwiJgKtGMxzrNy1SWSSqV1kxlhOcc0qQsNY95NtMlpBx4L5Y50JlUMitnMpnpnLXR2W7vytnnNfggauNV85Jcgl17QbOYs4z1GgFtdL5DlbPeO9Bi5Uwt3VZQIr4cisah-HbYsN0duzEVbP8HRb8Y_SaiXcL4AC9_CemeRNZr7ouHm4EY53RUXJKRyNknDQCEXw</recordid><startdate>201407</startdate><enddate>201407</enddate><creator>Numajiri, Haruhiko</creator><creator>Sasaki, Masashi</creator><creator>Aikawa, Takao</creator><creator>Sato, Hiroyasu</creator><creator>Kimura, Kazuhiro</creator><creator>Yamasaki, Haruki</creator><creator>Ishii, Juntaro</creator><creator>Yamada, Yoshiro</creator><general>Blackwell Publishing Ltd</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SC</scope><scope>7SP</scope><scope>8FD</scope><scope>JQ2</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope></search><sort><creationdate>201407</creationdate><title>Interlaboratory Comparison of the Co−C Eutectic Point with Small-Size Cell for Thermocouples</title><author>Numajiri, Haruhiko ; Sasaki, Masashi ; Aikawa, Takao ; Sato, Hiroyasu ; Kimura, Kazuhiro ; Yamasaki, Haruki ; Ishii, Juntaro ; Yamada, Yoshiro</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3003-e3c4f392f58b5ab45acff3c60989e54bbf9296dfbe59e972a8e1daca6bda4df83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Calibration</topic><topic>Eutectic temperature</topic><topic>fixed-point calibration</topic><topic>Furnaces</topic><topic>Interlaboratory</topic><topic>interlaboratory comparison</topic><topic>metal-carbon eutectic point</topic><topic>Metrology</topic><topic>Pilots</topic><topic>small-size cell</topic><topic>Temperature distribution</topic><topic>thermocouple</topic><topic>Thermocouples</topic><toplevel>online_resources</toplevel><creatorcontrib>Numajiri, Haruhiko</creatorcontrib><creatorcontrib>Sasaki, Masashi</creatorcontrib><creatorcontrib>Aikawa, Takao</creatorcontrib><creatorcontrib>Sato, Hiroyasu</creatorcontrib><creatorcontrib>Kimura, Kazuhiro</creatorcontrib><creatorcontrib>Yamasaki, Haruki</creatorcontrib><creatorcontrib>Ishii, Juntaro</creatorcontrib><creatorcontrib>Yamada, Yoshiro</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><collection>Computer and Information Systems Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Technology Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><jtitle>Electronics and communications in Japan</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Numajiri, Haruhiko</au><au>Sasaki, Masashi</au><au>Aikawa, Takao</au><au>Sato, Hiroyasu</au><au>Kimura, Kazuhiro</au><au>Yamasaki, Haruki</au><au>Ishii, Juntaro</au><au>Yamada, Yoshiro</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Interlaboratory Comparison of the Co−C Eutectic Point with Small-Size Cell for Thermocouples</atitle><jtitle>Electronics and communications in Japan</jtitle><addtitle>Electron Comm Jpn</addtitle><date>2014-07</date><risdate>2014</risdate><volume>97</volume><issue>7</issue><spage>48</spage><epage>54</epage><pages>48-54</pages><issn>1942-9533</issn><eissn>1942-9541</eissn><abstract>SUMMARY
Using a small‐size crucible, interlaboratory comparison of the realization of the Co−C eutectic point was performed in the industrial field in Japan, with the aim of verifying the possibility of thermocouple calibration at the eutectic point with an existing furnace of less‐than‐ideal temperature distribution, namely, the palladium‐point wire‐bridge method furnace for thermocouple calibration. A small‐size crucible for thermocouples was made by the National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (NMIJ/AIST). The interlaboratory comparison was piloted by the Tokyo Metropolitan Industrial Technology Research Institute (TIRI), a public test and research organization in Tokyo, and was conducted among five calibration laboratories including the pilot. One of the five laboratories is a designated calibration laboratory in Japan, and the other three are private laboratories. Four laboratories including TIRI used an existing palladium‐point furnace, and one laboratory made a new furnace for this interlaboratory comparison.</abstract><pub>Blackwell Publishing Ltd</pub><doi>10.1002/ecj.11583</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1942-9533 |
ispartof | Electronics and communications in Japan, 2014-07, Vol.97 (7), p.48-54 |
issn | 1942-9533 1942-9541 |
language | eng |
recordid | cdi_proquest_miscellaneous_1629363753 |
source | Wiley Online Library Journals Frontfile Complete; Business Source Complete |
subjects | Calibration Eutectic temperature fixed-point calibration Furnaces Interlaboratory interlaboratory comparison metal-carbon eutectic point Metrology Pilots small-size cell Temperature distribution thermocouple Thermocouples |
title | Interlaboratory Comparison of the Co−C Eutectic Point with Small-Size Cell for Thermocouples |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T13%3A37%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Interlaboratory%20Comparison%20of%20the%20Co%E2%88%92C%20Eutectic%20Point%20with%20Small-Size%20Cell%20for%20Thermocouples&rft.jtitle=Electronics%20and%20communications%20in%20Japan&rft.au=Numajiri,%20Haruhiko&rft.date=2014-07&rft.volume=97&rft.issue=7&rft.spage=48&rft.epage=54&rft.pages=48-54&rft.issn=1942-9533&rft.eissn=1942-9541&rft_id=info:doi/10.1002/ecj.11583&rft_dat=%3Cproquest_cross%3E1629363753%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1629363753&rft_id=info:pmid/&rfr_iscdi=true |