In vitro comparison of four different electronic apex locators to determine the major foramen using the clearing technique

The aim of this study was to evaluate the accuracy of four electronic apex locators (EALs) (DentaPort ZX, Raypex 5, Endo Master and VDW Gold) in detecting the major foramen using the clearing technique. Forty-eight extracted single-rooted extracted teeth with mature apices were used for the study an...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nigerian journal of clinical practice 2014-11, Vol.17 (6), p.706-710
Hauptverfasser: Altunbas, D, Kustarci, A, Arslan, D, Er, K
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 710
container_issue 6
container_start_page 706
container_title Nigerian journal of clinical practice
container_volume 17
creator Altunbas, D
Kustarci, A
Arslan, D
Er, K
description The aim of this study was to evaluate the accuracy of four electronic apex locators (EALs) (DentaPort ZX, Raypex 5, Endo Master and VDW Gold) in detecting the major foramen using the clearing technique. Forty-eight extracted single-rooted extracted teeth with mature apices were used for the study and divided into four groups of 12 teeth each. All teeth were embedded in an alginate model. Electronic measurements were taken using a size 15 K-file attached to the holder. Then, the teeth were cleared and photographed under a stereomicroscope with a digital camera. The distance between the tip of the file and the major foramen was measured by using an image analysis software program. Positive and negative values were recorded when the file tip was beyond or short of the major foramen and zero value when the file tip and the major foramen coincided. Statistical analysis was performed using the Kruskal-Wallis and Chi-square tests at a significance level of 0.05. Mean distance from the file tip to the major foramen were 0.302 ± 0.202, 0.065 ± 0.293, 0.117 ± 0.475, and 0.258 ± 0.160 mm in the DentaPort ZX, Raype 5, Endo Master, and VDW Gold groups, respectively. There were no statistically significant differences among the devices (P > 0.05) . Under the experimental conditions, all EALs showed an acceptable determination of the major foramen.
doi_str_mv 10.4103/1119-3077.144382
format Article
fullrecord <record><control><sourceid>gale_proqu</sourceid><recordid>TN_cdi_proquest_miscellaneous_1624935240</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A392270367</galeid><sourcerecordid>A392270367</sourcerecordid><originalsourceid>FETCH-LOGICAL-c397t-cdf0bb5ad81af2babb2dcde750247657680505972268125d54e694354194a5c73</originalsourceid><addsrcrecordid>eNptkc1rFTEUxWeh2Np235UEBOnmveZzMlmW4keh4EbXIZPc9KVkkmeSEetf70xfLRbkLsI9_M65hNN15wRvOcHskhCiNgxLuSWcs4G-6o6fpaPuba33GPeKDeRNd0QFG4TC_XH3-yahn6GVjGye9qaEmhPKHvk8F-SC91AgNQQR7AKlYJHZwy8UszUtl4paRg4alCkkQG0HaDL3uSz2YiZIaK4h3T3qNsKSvi5gdyn8mOG0e-1NrHD29J503z99_Hb9ZXP79fPN9dXtxjIl28Y6j8dRGDcQ4-loxpE660AKTLnshewHLLBQktJ-IFQ4waFXnAlOFDfCSnbSXRxy9yUvZ2vTU6gWYjQJ8lw16SlXTFCOF_T9Ab0zEXRIPrdi7IrrK6YolZj1a-D2P9QyDqZgcwIfFv2F4cM_hh2Y2HY1x7mFnOpLEB9AW3KtBbzelzCZ8qAJ1mvLeq1Ur5XqQ8uL5d3T7-ZxAvds-Fsx-wOrm6Mq</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1624935240</pqid></control><display><type>article</type><title>In vitro comparison of four different electronic apex locators to determine the major foramen using the clearing technique</title><source>African Journals Online (Open Access)</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Altunbas, D ; Kustarci, A ; Arslan, D ; Er, K</creator><creatorcontrib>Altunbas, D ; Kustarci, A ; Arslan, D ; Er, K</creatorcontrib><description>The aim of this study was to evaluate the accuracy of four electronic apex locators (EALs) (DentaPort ZX, Raypex 5, Endo Master and VDW Gold) in detecting the major foramen using the clearing technique. Forty-eight extracted single-rooted extracted teeth with mature apices were used for the study and divided into four groups of 12 teeth each. All teeth were embedded in an alginate model. Electronic measurements were taken using a size 15 K-file attached to the holder. Then, the teeth were cleared and photographed under a stereomicroscope with a digital camera. The distance between the tip of the file and the major foramen was measured by using an image analysis software program. Positive and negative values were recorded when the file tip was beyond or short of the major foramen and zero value when the file tip and the major foramen coincided. Statistical analysis was performed using the Kruskal-Wallis and Chi-square tests at a significance level of 0.05. Mean distance from the file tip to the major foramen were 0.302 ± 0.202, 0.065 ± 0.293, 0.117 ± 0.475, and 0.258 ± 0.160 mm in the DentaPort ZX, Raype 5, Endo Master, and VDW Gold groups, respectively. There were no statistically significant differences among the devices (P &gt; 0.05) . Under the experimental conditions, all EALs showed an acceptable determination of the major foramen.</description><identifier>ISSN: 1119-3077</identifier><identifier>DOI: 10.4103/1119-3077.144382</identifier><identifier>PMID: 25385906</identifier><language>eng</language><publisher>India: Medknow Publications and Media Pvt. Ltd</publisher><subject>Dental equipment and supplies ; Dental research ; Endodontics ; Technology application</subject><ispartof>Nigerian journal of clinical practice, 2014-11, Vol.17 (6), p.706-710</ispartof><rights>COPYRIGHT 2014 Medknow Publications and Media Pvt. Ltd.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c397t-cdf0bb5ad81af2babb2dcde750247657680505972268125d54e694354194a5c73</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25385906$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Altunbas, D</creatorcontrib><creatorcontrib>Kustarci, A</creatorcontrib><creatorcontrib>Arslan, D</creatorcontrib><creatorcontrib>Er, K</creatorcontrib><title>In vitro comparison of four different electronic apex locators to determine the major foramen using the clearing technique</title><title>Nigerian journal of clinical practice</title><addtitle>Niger J Clin Pract</addtitle><description>The aim of this study was to evaluate the accuracy of four electronic apex locators (EALs) (DentaPort ZX, Raypex 5, Endo Master and VDW Gold) in detecting the major foramen using the clearing technique. Forty-eight extracted single-rooted extracted teeth with mature apices were used for the study and divided into four groups of 12 teeth each. All teeth were embedded in an alginate model. Electronic measurements were taken using a size 15 K-file attached to the holder. Then, the teeth were cleared and photographed under a stereomicroscope with a digital camera. The distance between the tip of the file and the major foramen was measured by using an image analysis software program. Positive and negative values were recorded when the file tip was beyond or short of the major foramen and zero value when the file tip and the major foramen coincided. Statistical analysis was performed using the Kruskal-Wallis and Chi-square tests at a significance level of 0.05. Mean distance from the file tip to the major foramen were 0.302 ± 0.202, 0.065 ± 0.293, 0.117 ± 0.475, and 0.258 ± 0.160 mm in the DentaPort ZX, Raype 5, Endo Master, and VDW Gold groups, respectively. There were no statistically significant differences among the devices (P &gt; 0.05) . Under the experimental conditions, all EALs showed an acceptable determination of the major foramen.</description><subject>Dental equipment and supplies</subject><subject>Dental research</subject><subject>Endodontics</subject><subject>Technology application</subject><issn>1119-3077</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNptkc1rFTEUxWeh2Np235UEBOnmveZzMlmW4keh4EbXIZPc9KVkkmeSEetf70xfLRbkLsI9_M65hNN15wRvOcHskhCiNgxLuSWcs4G-6o6fpaPuba33GPeKDeRNd0QFG4TC_XH3-yahn6GVjGye9qaEmhPKHvk8F-SC91AgNQQR7AKlYJHZwy8UszUtl4paRg4alCkkQG0HaDL3uSz2YiZIaK4h3T3qNsKSvi5gdyn8mOG0e-1NrHD29J503z99_Hb9ZXP79fPN9dXtxjIl28Y6j8dRGDcQ4-loxpE660AKTLnshewHLLBQktJ-IFQ4waFXnAlOFDfCSnbSXRxy9yUvZ2vTU6gWYjQJ8lw16SlXTFCOF_T9Ab0zEXRIPrdi7IrrK6YolZj1a-D2P9QyDqZgcwIfFv2F4cM_hh2Y2HY1x7mFnOpLEB9AW3KtBbzelzCZ8qAJ1mvLeq1Ur5XqQ8uL5d3T7-ZxAvds-Fsx-wOrm6Mq</recordid><startdate>20141101</startdate><enddate>20141101</enddate><creator>Altunbas, D</creator><creator>Kustarci, A</creator><creator>Arslan, D</creator><creator>Er, K</creator><general>Medknow Publications and Media Pvt. Ltd</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20141101</creationdate><title>In vitro comparison of four different electronic apex locators to determine the major foramen using the clearing technique</title><author>Altunbas, D ; Kustarci, A ; Arslan, D ; Er, K</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c397t-cdf0bb5ad81af2babb2dcde750247657680505972268125d54e694354194a5c73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Dental equipment and supplies</topic><topic>Dental research</topic><topic>Endodontics</topic><topic>Technology application</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Altunbas, D</creatorcontrib><creatorcontrib>Kustarci, A</creatorcontrib><creatorcontrib>Arslan, D</creatorcontrib><creatorcontrib>Er, K</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Nigerian journal of clinical practice</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Altunbas, D</au><au>Kustarci, A</au><au>Arslan, D</au><au>Er, K</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>In vitro comparison of four different electronic apex locators to determine the major foramen using the clearing technique</atitle><jtitle>Nigerian journal of clinical practice</jtitle><addtitle>Niger J Clin Pract</addtitle><date>2014-11-01</date><risdate>2014</risdate><volume>17</volume><issue>6</issue><spage>706</spage><epage>710</epage><pages>706-710</pages><issn>1119-3077</issn><abstract>The aim of this study was to evaluate the accuracy of four electronic apex locators (EALs) (DentaPort ZX, Raypex 5, Endo Master and VDW Gold) in detecting the major foramen using the clearing technique. Forty-eight extracted single-rooted extracted teeth with mature apices were used for the study and divided into four groups of 12 teeth each. All teeth were embedded in an alginate model. Electronic measurements were taken using a size 15 K-file attached to the holder. Then, the teeth were cleared and photographed under a stereomicroscope with a digital camera. The distance between the tip of the file and the major foramen was measured by using an image analysis software program. Positive and negative values were recorded when the file tip was beyond or short of the major foramen and zero value when the file tip and the major foramen coincided. Statistical analysis was performed using the Kruskal-Wallis and Chi-square tests at a significance level of 0.05. Mean distance from the file tip to the major foramen were 0.302 ± 0.202, 0.065 ± 0.293, 0.117 ± 0.475, and 0.258 ± 0.160 mm in the DentaPort ZX, Raype 5, Endo Master, and VDW Gold groups, respectively. There were no statistically significant differences among the devices (P &gt; 0.05) . Under the experimental conditions, all EALs showed an acceptable determination of the major foramen.</abstract><cop>India</cop><pub>Medknow Publications and Media Pvt. Ltd</pub><pmid>25385906</pmid><doi>10.4103/1119-3077.144382</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1119-3077
ispartof Nigerian journal of clinical practice, 2014-11, Vol.17 (6), p.706-710
issn 1119-3077
language eng
recordid cdi_proquest_miscellaneous_1624935240
source African Journals Online (Open Access); EZB-FREE-00999 freely available EZB journals
subjects Dental equipment and supplies
Dental research
Endodontics
Technology application
title In vitro comparison of four different electronic apex locators to determine the major foramen using the clearing technique
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T11%3A06%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=In%20vitro%20comparison%20of%20four%20different%20electronic%20apex%20locators%20to%20determine%20the%20major%20foramen%20using%20the%20clearing%20technique&rft.jtitle=Nigerian%20journal%20of%20clinical%20practice&rft.au=Altunbas,%20D&rft.date=2014-11-01&rft.volume=17&rft.issue=6&rft.spage=706&rft.epage=710&rft.pages=706-710&rft.issn=1119-3077&rft_id=info:doi/10.4103/1119-3077.144382&rft_dat=%3Cgale_proqu%3EA392270367%3C/gale_proqu%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1624935240&rft_id=info:pmid/25385906&rft_galeid=A392270367&rfr_iscdi=true