New reliable methods for the diagnose of protein-energy wasting in hemodialysis patients

Protein-energy wasting (PEW), defined as the body loss of muscle mass and fat, is an important cardiovascular risk factor in dialysis patients. Diagnosing this condition requires the presence of three characteristics: biochemical (low albumine, prealbumine or cholesterol), body mass reduction (body...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nutrición hospitalaria : organo oficial de la Sociedad Española de Nutrición Parenteral y Enteral 2014-10, Vol.30 (4), p.905-910
Hauptverfasser: Castellano-Gasch, Sandra, Palomares-Sancho, Inés, Molina-Núñez, Manuel, Ramos-Sánchez, Rosa, Merello-Godino, José I, Maduell, Francisco
Format: Artikel
Sprache:spa
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 910
container_issue 4
container_start_page 905
container_title Nutrición hospitalaria : organo oficial de la Sociedad Española de Nutrición Parenteral y Enteral
container_volume 30
creator Castellano-Gasch, Sandra
Palomares-Sancho, Inés
Molina-Núñez, Manuel
Ramos-Sánchez, Rosa
Merello-Godino, José I
Maduell, Francisco
description Protein-energy wasting (PEW), defined as the body loss of muscle mass and fat, is an important cardiovascular risk factor in dialysis patients. Diagnosing this condition requires the presence of three characteristics: biochemical (low albumine, prealbumine or cholesterol), body mass reduction (body mass index, weight loss or fat loss) and muscle mass reduction (measured by means of creatinine or arm muscle area). This study aimed at demonstrating that the lean tissue index (LTI) calculated by spectroscopic bioimpedance (SBI) is a valid parameter for the diagnostic of protein-energy wasting. Cross-sectional study including 1369 patients with two BCM measurements on a six-month delay, analyzing analytic and spectroscopic bioimpedance parameters. The lean tissue index from the BCM (Body Composition Monitor) quantifies the patient's lean mass and it is matched against traditional parameters (plasma albumine) and non-traditional parameters (IRE and PCR) for protein-energy wasting with no alterations from the patient's hydration level. LTI is an easy to obtain parameter of lean mass which can be followed and monitored in order to diagnose risk situations of our patients as it is the protein- energy wasting.
doi_str_mv 10.3305/nh.2014.30.4.7730
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_1615745810</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1615745810</sourcerecordid><originalsourceid>FETCH-LOGICAL-p141t-d6ce26a32b52c986d54f614df333fea58b2311eb06d6d8bc9f422ded6f5077053</originalsourceid><addsrcrecordid>eNo10E1LwzAcBvAgiJvTD-BFcvTSmvemRxm-wdCLgreSNv-skTapTcbYt3fgPD2XHw8PD0I3lJScE3kf-pIRKkpOSlFWFSdnaElVXReS1nqBLlP6JoTVRKsLtGCSc6k0WaKvN9jjGQZv2gHwCLmPNmEXZ5x7wNabbYgJcHR4mmMGHwoIMG8PeG9S9mGLfcA9jPEoh0PyCU8mewg5XaFzZ4YE16dcoc-nx4_1S7F5f35dP2yKiQqaC6s6YMpw1krW1VpZKZyiwjrOuQMjdcs4pdASZZXVbVc7wZgFq5wkVUUkX6G7v97jvp8dpNyMPnUwDCZA3KWGKiorITUlR3p7ort2BNtMsx_NfGj-3-C_CQdg-Q</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1615745810</pqid></control><display><type>article</type><title>New reliable methods for the diagnose of protein-energy wasting in hemodialysis patients</title><source>MEDLINE</source><source>DOAJ Directory of Open Access Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Alma/SFX Local Collection</source><creator>Castellano-Gasch, Sandra ; Palomares-Sancho, Inés ; Molina-Núñez, Manuel ; Ramos-Sánchez, Rosa ; Merello-Godino, José I ; Maduell, Francisco</creator><creatorcontrib>Castellano-Gasch, Sandra ; Palomares-Sancho, Inés ; Molina-Núñez, Manuel ; Ramos-Sánchez, Rosa ; Merello-Godino, José I ; Maduell, Francisco</creatorcontrib><description>Protein-energy wasting (PEW), defined as the body loss of muscle mass and fat, is an important cardiovascular risk factor in dialysis patients. Diagnosing this condition requires the presence of three characteristics: biochemical (low albumine, prealbumine or cholesterol), body mass reduction (body mass index, weight loss or fat loss) and muscle mass reduction (measured by means of creatinine or arm muscle area). This study aimed at demonstrating that the lean tissue index (LTI) calculated by spectroscopic bioimpedance (SBI) is a valid parameter for the diagnostic of protein-energy wasting. Cross-sectional study including 1369 patients with two BCM measurements on a six-month delay, analyzing analytic and spectroscopic bioimpedance parameters. The lean tissue index from the BCM (Body Composition Monitor) quantifies the patient's lean mass and it is matched against traditional parameters (plasma albumine) and non-traditional parameters (IRE and PCR) for protein-energy wasting with no alterations from the patient's hydration level. LTI is an easy to obtain parameter of lean mass which can be followed and monitored in order to diagnose risk situations of our patients as it is the protein- energy wasting.</description><identifier>EISSN: 1699-5198</identifier><identifier>DOI: 10.3305/nh.2014.30.4.7730</identifier><identifier>PMID: 25335680</identifier><language>spa</language><publisher>Spain</publisher><subject>Aged ; Cross-Sectional Studies ; Electric Impedance ; Female ; Humans ; Male ; Protein-Energy Malnutrition - diagnosis ; Renal Dialysis ; Reproducibility of Results</subject><ispartof>Nutrición hospitalaria : organo oficial de la Sociedad Española de Nutrición Parenteral y Enteral, 2014-10, Vol.30 (4), p.905-910</ispartof><rights>Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,860,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25335680$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Castellano-Gasch, Sandra</creatorcontrib><creatorcontrib>Palomares-Sancho, Inés</creatorcontrib><creatorcontrib>Molina-Núñez, Manuel</creatorcontrib><creatorcontrib>Ramos-Sánchez, Rosa</creatorcontrib><creatorcontrib>Merello-Godino, José I</creatorcontrib><creatorcontrib>Maduell, Francisco</creatorcontrib><title>New reliable methods for the diagnose of protein-energy wasting in hemodialysis patients</title><title>Nutrición hospitalaria : organo oficial de la Sociedad Española de Nutrición Parenteral y Enteral</title><addtitle>Nutr Hosp</addtitle><description>Protein-energy wasting (PEW), defined as the body loss of muscle mass and fat, is an important cardiovascular risk factor in dialysis patients. Diagnosing this condition requires the presence of three characteristics: biochemical (low albumine, prealbumine or cholesterol), body mass reduction (body mass index, weight loss or fat loss) and muscle mass reduction (measured by means of creatinine or arm muscle area). This study aimed at demonstrating that the lean tissue index (LTI) calculated by spectroscopic bioimpedance (SBI) is a valid parameter for the diagnostic of protein-energy wasting. Cross-sectional study including 1369 patients with two BCM measurements on a six-month delay, analyzing analytic and spectroscopic bioimpedance parameters. The lean tissue index from the BCM (Body Composition Monitor) quantifies the patient's lean mass and it is matched against traditional parameters (plasma albumine) and non-traditional parameters (IRE and PCR) for protein-energy wasting with no alterations from the patient's hydration level. LTI is an easy to obtain parameter of lean mass which can be followed and monitored in order to diagnose risk situations of our patients as it is the protein- energy wasting.</description><subject>Aged</subject><subject>Cross-Sectional Studies</subject><subject>Electric Impedance</subject><subject>Female</subject><subject>Humans</subject><subject>Male</subject><subject>Protein-Energy Malnutrition - diagnosis</subject><subject>Renal Dialysis</subject><subject>Reproducibility of Results</subject><issn>1699-5198</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo10E1LwzAcBvAgiJvTD-BFcvTSmvemRxm-wdCLgreSNv-skTapTcbYt3fgPD2XHw8PD0I3lJScE3kf-pIRKkpOSlFWFSdnaElVXReS1nqBLlP6JoTVRKsLtGCSc6k0WaKvN9jjGQZv2gHwCLmPNmEXZ5x7wNabbYgJcHR4mmMGHwoIMG8PeG9S9mGLfcA9jPEoh0PyCU8mewg5XaFzZ4YE16dcoc-nx4_1S7F5f35dP2yKiQqaC6s6YMpw1krW1VpZKZyiwjrOuQMjdcs4pdASZZXVbVc7wZgFq5wkVUUkX6G7v97jvp8dpNyMPnUwDCZA3KWGKiorITUlR3p7ort2BNtMsx_NfGj-3-C_CQdg-Q</recordid><startdate>20141001</startdate><enddate>20141001</enddate><creator>Castellano-Gasch, Sandra</creator><creator>Palomares-Sancho, Inés</creator><creator>Molina-Núñez, Manuel</creator><creator>Ramos-Sánchez, Rosa</creator><creator>Merello-Godino, José I</creator><creator>Maduell, Francisco</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>20141001</creationdate><title>New reliable methods for the diagnose of protein-energy wasting in hemodialysis patients</title><author>Castellano-Gasch, Sandra ; Palomares-Sancho, Inés ; Molina-Núñez, Manuel ; Ramos-Sánchez, Rosa ; Merello-Godino, José I ; Maduell, Francisco</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p141t-d6ce26a32b52c986d54f614df333fea58b2311eb06d6d8bc9f422ded6f5077053</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>spa</language><creationdate>2014</creationdate><topic>Aged</topic><topic>Cross-Sectional Studies</topic><topic>Electric Impedance</topic><topic>Female</topic><topic>Humans</topic><topic>Male</topic><topic>Protein-Energy Malnutrition - diagnosis</topic><topic>Renal Dialysis</topic><topic>Reproducibility of Results</topic><toplevel>online_resources</toplevel><creatorcontrib>Castellano-Gasch, Sandra</creatorcontrib><creatorcontrib>Palomares-Sancho, Inés</creatorcontrib><creatorcontrib>Molina-Núñez, Manuel</creatorcontrib><creatorcontrib>Ramos-Sánchez, Rosa</creatorcontrib><creatorcontrib>Merello-Godino, José I</creatorcontrib><creatorcontrib>Maduell, Francisco</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Nutrición hospitalaria : organo oficial de la Sociedad Española de Nutrición Parenteral y Enteral</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Castellano-Gasch, Sandra</au><au>Palomares-Sancho, Inés</au><au>Molina-Núñez, Manuel</au><au>Ramos-Sánchez, Rosa</au><au>Merello-Godino, José I</au><au>Maduell, Francisco</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>New reliable methods for the diagnose of protein-energy wasting in hemodialysis patients</atitle><jtitle>Nutrición hospitalaria : organo oficial de la Sociedad Española de Nutrición Parenteral y Enteral</jtitle><addtitle>Nutr Hosp</addtitle><date>2014-10-01</date><risdate>2014</risdate><volume>30</volume><issue>4</issue><spage>905</spage><epage>910</epage><pages>905-910</pages><eissn>1699-5198</eissn><abstract>Protein-energy wasting (PEW), defined as the body loss of muscle mass and fat, is an important cardiovascular risk factor in dialysis patients. Diagnosing this condition requires the presence of three characteristics: biochemical (low albumine, prealbumine or cholesterol), body mass reduction (body mass index, weight loss or fat loss) and muscle mass reduction (measured by means of creatinine or arm muscle area). This study aimed at demonstrating that the lean tissue index (LTI) calculated by spectroscopic bioimpedance (SBI) is a valid parameter for the diagnostic of protein-energy wasting. Cross-sectional study including 1369 patients with two BCM measurements on a six-month delay, analyzing analytic and spectroscopic bioimpedance parameters. The lean tissue index from the BCM (Body Composition Monitor) quantifies the patient's lean mass and it is matched against traditional parameters (plasma albumine) and non-traditional parameters (IRE and PCR) for protein-energy wasting with no alterations from the patient's hydration level. LTI is an easy to obtain parameter of lean mass which can be followed and monitored in order to diagnose risk situations of our patients as it is the protein- energy wasting.</abstract><cop>Spain</cop><pmid>25335680</pmid><doi>10.3305/nh.2014.30.4.7730</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier EISSN: 1699-5198
ispartof Nutrición hospitalaria : organo oficial de la Sociedad Española de Nutrición Parenteral y Enteral, 2014-10, Vol.30 (4), p.905-910
issn 1699-5198
language spa
recordid cdi_proquest_miscellaneous_1615745810
source MEDLINE; DOAJ Directory of Open Access Journals; EZB-FREE-00999 freely available EZB journals; Alma/SFX Local Collection
subjects Aged
Cross-Sectional Studies
Electric Impedance
Female
Humans
Male
Protein-Energy Malnutrition - diagnosis
Renal Dialysis
Reproducibility of Results
title New reliable methods for the diagnose of protein-energy wasting in hemodialysis patients
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-07T13%3A03%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=New%20reliable%20methods%20for%20the%20diagnose%20of%20protein-energy%20wasting%20in%20hemodialysis%20patients&rft.jtitle=Nutrici%C3%B3n%20hospitalaria%20:%20organo%20oficial%20de%20la%20Sociedad%20Espa%C3%B1ola%20de%20Nutrici%C3%B3n%20Parenteral%20y%20Enteral&rft.au=Castellano-Gasch,%20Sandra&rft.date=2014-10-01&rft.volume=30&rft.issue=4&rft.spage=905&rft.epage=910&rft.pages=905-910&rft.eissn=1699-5198&rft_id=info:doi/10.3305/nh.2014.30.4.7730&rft_dat=%3Cproquest_pubme%3E1615745810%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1615745810&rft_id=info:pmid/25335680&rfr_iscdi=true