Evaluation of an application for intensity-based deformable image registration and dose accumulation in radiotherapy

Abstract Background. Methods to accurately accumulate doses in radiotherapy (RT) are important for tumour and normal tissues being influenced by geometric uncertainties. The purpose of this study was to investigate a pre-release deformable image registration (DIR)-based dose accumulation application...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Acta oncologica 2014-10, Vol.53 (10), p.1329-1336
Hauptverfasser: Thor, Maria, Andersen, Else S., Petersen, Jørgen B. B., Sørensen, Thomas S., Noe, Karsten Ø., Tanderup, Kari, Bentzen, Lise, Elstrøm, Ulrik V., Høyer, Morten, Muren, Ludvig P.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1336
container_issue 10
container_start_page 1329
container_title Acta oncologica
container_volume 53
creator Thor, Maria
Andersen, Else S.
Petersen, Jørgen B. B.
Sørensen, Thomas S.
Noe, Karsten Ø.
Tanderup, Kari
Bentzen, Lise
Elstrøm, Ulrik V.
Høyer, Morten
Muren, Ludvig P.
description Abstract Background. Methods to accurately accumulate doses in radiotherapy (RT) are important for tumour and normal tissues being influenced by geometric uncertainties. The purpose of this study was to investigate a pre-release deformable image registration (DIR)-based dose accumulation application, in the setting of prostate RT. Material and methods. Initially accumulated bladder and prostate doses were assessed (based on 8-9 repeat CT scans/patient) for nine prostate cancer patients using an intensity-based DIR and dose accumulation algorithm as provided by the Dynamic Adaptive Radiation Therapy (DART) software. The accumulated bladder and prostate dose-volume histograms (DVHs) were compared on a range of parameters (paired Wilcoxon signed-rank test, 5% significance level) to DVHs derived using an in-house developed dose accumulation method based on biomechanical, contour-driven DIR (SurfaceRegistration). Finally, both these accumulated dose distributions were compared to the 'static' DVH, assessed from the planning CT. Results. Over the population, doses accumulated with DART were overall lower than those from SurfaceRegistration (p < 0.05: D2%, gEUD and NTCP (bladder); Dmin (prostate)). The magnitude of these differences peaked for the bladder gEUD with a population median of 47 Gy for DART versus 57 Gy for SurfaceRegistration. Across the ten bladder dose/volume parameters investigated, the most pronounced individual differences were observed between the 'accumulated' DVHs and the 'static' DVHs, with deviations in mean dose up to 22 Gy. Conclusion. Substantial and significant differences were observed in the dose distributions between the two investigated DIR-based dose accumulation applications. The most pronounced individual differences were seen for the bladder and relative to the planned dose distribution, encouraging the use of repeat imaging data in RT planning and evaluation for this organ.
doi_str_mv 10.3109/0284186X.2014.928742
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1614694289</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1614694289</sourcerecordid><originalsourceid>FETCH-LOGICAL-c474t-41ea44b7351d8a3e583e035008037a0273f56427aa7bb6dc4951b6a4ff9b12ab3</originalsourceid><addsrcrecordid>eNp9kE1r3DAURUVpaCZp_0EpWnbjqT4te1MoIU0CgW5SyE482c8ZBVtyJbkw_76eOumyK8HlXD3uIeQjZ3vJWfuFiUbxpn7cC8bVvhWNUeIN2fFa80qI-vEt2Z2Q6sSck4ucnxljQhr9jpwL1WqjtdqRcv0bxgWKj4HGgUKgMM-j77ZkiIn6UDBkX46Vg4w97XFNJ3AjUj_BE9KETz6XtDUgrETMSKHrlmkZt9QHmqD3sRwwwXx8T84GGDN-eHkvyc_v1w9Xt9X9j5u7q2_3VaeMKpXiCEo5IzXvG5CoG4lMasYaJg0wYeSgayUMgHGu7rt1FHc1qGFoHRfg5CX5vP07p_hrwVzs5HOH4wgB45Itr7mqWyWadkXVhnYp5pxwsHNa56Wj5cyefNtX3_bk226-19qnlwuLm7D_V3oVvAJfN8CHv9oOCGM5dJDQPsclhXX-_y_8AZcTkS8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1614694289</pqid></control><display><type>article</type><title>Evaluation of an application for intensity-based deformable image registration and dose accumulation in radiotherapy</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Taylor &amp; Francis Journals Complete</source><source>Alma/SFX Local Collection</source><creator>Thor, Maria ; Andersen, Else S. ; Petersen, Jørgen B. B. ; Sørensen, Thomas S. ; Noe, Karsten Ø. ; Tanderup, Kari ; Bentzen, Lise ; Elstrøm, Ulrik V. ; Høyer, Morten ; Muren, Ludvig P.</creator><creatorcontrib>Thor, Maria ; Andersen, Else S. ; Petersen, Jørgen B. B. ; Sørensen, Thomas S. ; Noe, Karsten Ø. ; Tanderup, Kari ; Bentzen, Lise ; Elstrøm, Ulrik V. ; Høyer, Morten ; Muren, Ludvig P.</creatorcontrib><description>Abstract Background. Methods to accurately accumulate doses in radiotherapy (RT) are important for tumour and normal tissues being influenced by geometric uncertainties. The purpose of this study was to investigate a pre-release deformable image registration (DIR)-based dose accumulation application, in the setting of prostate RT. Material and methods. Initially accumulated bladder and prostate doses were assessed (based on 8-9 repeat CT scans/patient) for nine prostate cancer patients using an intensity-based DIR and dose accumulation algorithm as provided by the Dynamic Adaptive Radiation Therapy (DART) software. The accumulated bladder and prostate dose-volume histograms (DVHs) were compared on a range of parameters (paired Wilcoxon signed-rank test, 5% significance level) to DVHs derived using an in-house developed dose accumulation method based on biomechanical, contour-driven DIR (SurfaceRegistration). Finally, both these accumulated dose distributions were compared to the 'static' DVH, assessed from the planning CT. Results. Over the population, doses accumulated with DART were overall lower than those from SurfaceRegistration (p &lt; 0.05: D2%, gEUD and NTCP (bladder); Dmin (prostate)). The magnitude of these differences peaked for the bladder gEUD with a population median of 47 Gy for DART versus 57 Gy for SurfaceRegistration. Across the ten bladder dose/volume parameters investigated, the most pronounced individual differences were observed between the 'accumulated' DVHs and the 'static' DVHs, with deviations in mean dose up to 22 Gy. Conclusion. Substantial and significant differences were observed in the dose distributions between the two investigated DIR-based dose accumulation applications. The most pronounced individual differences were seen for the bladder and relative to the planned dose distribution, encouraging the use of repeat imaging data in RT planning and evaluation for this organ.</description><identifier>ISSN: 0284-186X</identifier><identifier>EISSN: 1651-226X</identifier><identifier>DOI: 10.3109/0284186X.2014.928742</identifier><identifier>PMID: 24957554</identifier><language>eng</language><publisher>England: Informa Healthcare</publisher><subject>Dose-Response Relationship, Radiation ; Humans ; Male ; Organs at Risk - radiation effects ; Prostate - diagnostic imaging ; Prostate - radiation effects ; Prostatic Neoplasms - diagnostic imaging ; Prostatic Neoplasms - radiotherapy ; Radiotherapy Dosage ; Radiotherapy, Intensity-Modulated ; Statistics, Nonparametric ; Tomography, X-Ray Computed - methods ; Urinary Bladder - diagnostic imaging ; Urinary Bladder - radiation effects</subject><ispartof>Acta oncologica, 2014-10, Vol.53 (10), p.1329-1336</ispartof><rights>2014 Informa Healthcare 2014</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c474t-41ea44b7351d8a3e583e035008037a0273f56427aa7bb6dc4951b6a4ff9b12ab3</citedby><cites>FETCH-LOGICAL-c474t-41ea44b7351d8a3e583e035008037a0273f56427aa7bb6dc4951b6a4ff9b12ab3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.tandfonline.com/doi/pdf/10.3109/0284186X.2014.928742$$EPDF$$P50$$Ginformahealthcare$$H</linktopdf><linktohtml>$$Uhttps://www.tandfonline.com/doi/full/10.3109/0284186X.2014.928742$$EHTML$$P50$$Ginformahealthcare$$H</linktohtml><link.rule.ids>314,777,781,27905,27906,61200,61381</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24957554$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Thor, Maria</creatorcontrib><creatorcontrib>Andersen, Else S.</creatorcontrib><creatorcontrib>Petersen, Jørgen B. B.</creatorcontrib><creatorcontrib>Sørensen, Thomas S.</creatorcontrib><creatorcontrib>Noe, Karsten Ø.</creatorcontrib><creatorcontrib>Tanderup, Kari</creatorcontrib><creatorcontrib>Bentzen, Lise</creatorcontrib><creatorcontrib>Elstrøm, Ulrik V.</creatorcontrib><creatorcontrib>Høyer, Morten</creatorcontrib><creatorcontrib>Muren, Ludvig P.</creatorcontrib><title>Evaluation of an application for intensity-based deformable image registration and dose accumulation in radiotherapy</title><title>Acta oncologica</title><addtitle>Acta Oncol</addtitle><description>Abstract Background. Methods to accurately accumulate doses in radiotherapy (RT) are important for tumour and normal tissues being influenced by geometric uncertainties. The purpose of this study was to investigate a pre-release deformable image registration (DIR)-based dose accumulation application, in the setting of prostate RT. Material and methods. Initially accumulated bladder and prostate doses were assessed (based on 8-9 repeat CT scans/patient) for nine prostate cancer patients using an intensity-based DIR and dose accumulation algorithm as provided by the Dynamic Adaptive Radiation Therapy (DART) software. The accumulated bladder and prostate dose-volume histograms (DVHs) were compared on a range of parameters (paired Wilcoxon signed-rank test, 5% significance level) to DVHs derived using an in-house developed dose accumulation method based on biomechanical, contour-driven DIR (SurfaceRegistration). Finally, both these accumulated dose distributions were compared to the 'static' DVH, assessed from the planning CT. Results. Over the population, doses accumulated with DART were overall lower than those from SurfaceRegistration (p &lt; 0.05: D2%, gEUD and NTCP (bladder); Dmin (prostate)). The magnitude of these differences peaked for the bladder gEUD with a population median of 47 Gy for DART versus 57 Gy for SurfaceRegistration. Across the ten bladder dose/volume parameters investigated, the most pronounced individual differences were observed between the 'accumulated' DVHs and the 'static' DVHs, with deviations in mean dose up to 22 Gy. Conclusion. Substantial and significant differences were observed in the dose distributions between the two investigated DIR-based dose accumulation applications. The most pronounced individual differences were seen for the bladder and relative to the planned dose distribution, encouraging the use of repeat imaging data in RT planning and evaluation for this organ.</description><subject>Dose-Response Relationship, Radiation</subject><subject>Humans</subject><subject>Male</subject><subject>Organs at Risk - radiation effects</subject><subject>Prostate - diagnostic imaging</subject><subject>Prostate - radiation effects</subject><subject>Prostatic Neoplasms - diagnostic imaging</subject><subject>Prostatic Neoplasms - radiotherapy</subject><subject>Radiotherapy Dosage</subject><subject>Radiotherapy, Intensity-Modulated</subject><subject>Statistics, Nonparametric</subject><subject>Tomography, X-Ray Computed - methods</subject><subject>Urinary Bladder - diagnostic imaging</subject><subject>Urinary Bladder - radiation effects</subject><issn>0284-186X</issn><issn>1651-226X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kE1r3DAURUVpaCZp_0EpWnbjqT4te1MoIU0CgW5SyE482c8ZBVtyJbkw_76eOumyK8HlXD3uIeQjZ3vJWfuFiUbxpn7cC8bVvhWNUeIN2fFa80qI-vEt2Z2Q6sSck4ucnxljQhr9jpwL1WqjtdqRcv0bxgWKj4HGgUKgMM-j77ZkiIn6UDBkX46Vg4w97XFNJ3AjUj_BE9KETz6XtDUgrETMSKHrlmkZt9QHmqD3sRwwwXx8T84GGDN-eHkvyc_v1w9Xt9X9j5u7q2_3VaeMKpXiCEo5IzXvG5CoG4lMasYaJg0wYeSgayUMgHGu7rt1FHc1qGFoHRfg5CX5vP07p_hrwVzs5HOH4wgB45Itr7mqWyWadkXVhnYp5pxwsHNa56Wj5cyefNtX3_bk226-19qnlwuLm7D_V3oVvAJfN8CHv9oOCGM5dJDQPsclhXX-_y_8AZcTkS8</recordid><startdate>20141001</startdate><enddate>20141001</enddate><creator>Thor, Maria</creator><creator>Andersen, Else S.</creator><creator>Petersen, Jørgen B. B.</creator><creator>Sørensen, Thomas S.</creator><creator>Noe, Karsten Ø.</creator><creator>Tanderup, Kari</creator><creator>Bentzen, Lise</creator><creator>Elstrøm, Ulrik V.</creator><creator>Høyer, Morten</creator><creator>Muren, Ludvig P.</creator><general>Informa Healthcare</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20141001</creationdate><title>Evaluation of an application for intensity-based deformable image registration and dose accumulation in radiotherapy</title><author>Thor, Maria ; Andersen, Else S. ; Petersen, Jørgen B. B. ; Sørensen, Thomas S. ; Noe, Karsten Ø. ; Tanderup, Kari ; Bentzen, Lise ; Elstrøm, Ulrik V. ; Høyer, Morten ; Muren, Ludvig P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c474t-41ea44b7351d8a3e583e035008037a0273f56427aa7bb6dc4951b6a4ff9b12ab3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Dose-Response Relationship, Radiation</topic><topic>Humans</topic><topic>Male</topic><topic>Organs at Risk - radiation effects</topic><topic>Prostate - diagnostic imaging</topic><topic>Prostate - radiation effects</topic><topic>Prostatic Neoplasms - diagnostic imaging</topic><topic>Prostatic Neoplasms - radiotherapy</topic><topic>Radiotherapy Dosage</topic><topic>Radiotherapy, Intensity-Modulated</topic><topic>Statistics, Nonparametric</topic><topic>Tomography, X-Ray Computed - methods</topic><topic>Urinary Bladder - diagnostic imaging</topic><topic>Urinary Bladder - radiation effects</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Thor, Maria</creatorcontrib><creatorcontrib>Andersen, Else S.</creatorcontrib><creatorcontrib>Petersen, Jørgen B. B.</creatorcontrib><creatorcontrib>Sørensen, Thomas S.</creatorcontrib><creatorcontrib>Noe, Karsten Ø.</creatorcontrib><creatorcontrib>Tanderup, Kari</creatorcontrib><creatorcontrib>Bentzen, Lise</creatorcontrib><creatorcontrib>Elstrøm, Ulrik V.</creatorcontrib><creatorcontrib>Høyer, Morten</creatorcontrib><creatorcontrib>Muren, Ludvig P.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Acta oncologica</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Thor, Maria</au><au>Andersen, Else S.</au><au>Petersen, Jørgen B. B.</au><au>Sørensen, Thomas S.</au><au>Noe, Karsten Ø.</au><au>Tanderup, Kari</au><au>Bentzen, Lise</au><au>Elstrøm, Ulrik V.</au><au>Høyer, Morten</au><au>Muren, Ludvig P.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of an application for intensity-based deformable image registration and dose accumulation in radiotherapy</atitle><jtitle>Acta oncologica</jtitle><addtitle>Acta Oncol</addtitle><date>2014-10-01</date><risdate>2014</risdate><volume>53</volume><issue>10</issue><spage>1329</spage><epage>1336</epage><pages>1329-1336</pages><issn>0284-186X</issn><eissn>1651-226X</eissn><abstract>Abstract Background. Methods to accurately accumulate doses in radiotherapy (RT) are important for tumour and normal tissues being influenced by geometric uncertainties. The purpose of this study was to investigate a pre-release deformable image registration (DIR)-based dose accumulation application, in the setting of prostate RT. Material and methods. Initially accumulated bladder and prostate doses were assessed (based on 8-9 repeat CT scans/patient) for nine prostate cancer patients using an intensity-based DIR and dose accumulation algorithm as provided by the Dynamic Adaptive Radiation Therapy (DART) software. The accumulated bladder and prostate dose-volume histograms (DVHs) were compared on a range of parameters (paired Wilcoxon signed-rank test, 5% significance level) to DVHs derived using an in-house developed dose accumulation method based on biomechanical, contour-driven DIR (SurfaceRegistration). Finally, both these accumulated dose distributions were compared to the 'static' DVH, assessed from the planning CT. Results. Over the population, doses accumulated with DART were overall lower than those from SurfaceRegistration (p &lt; 0.05: D2%, gEUD and NTCP (bladder); Dmin (prostate)). The magnitude of these differences peaked for the bladder gEUD with a population median of 47 Gy for DART versus 57 Gy for SurfaceRegistration. Across the ten bladder dose/volume parameters investigated, the most pronounced individual differences were observed between the 'accumulated' DVHs and the 'static' DVHs, with deviations in mean dose up to 22 Gy. Conclusion. Substantial and significant differences were observed in the dose distributions between the two investigated DIR-based dose accumulation applications. The most pronounced individual differences were seen for the bladder and relative to the planned dose distribution, encouraging the use of repeat imaging data in RT planning and evaluation for this organ.</abstract><cop>England</cop><pub>Informa Healthcare</pub><pmid>24957554</pmid><doi>10.3109/0284186X.2014.928742</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0284-186X
ispartof Acta oncologica, 2014-10, Vol.53 (10), p.1329-1336
issn 0284-186X
1651-226X
language eng
recordid cdi_proquest_miscellaneous_1614694289
source MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Taylor & Francis Journals Complete; Alma/SFX Local Collection
subjects Dose-Response Relationship, Radiation
Humans
Male
Organs at Risk - radiation effects
Prostate - diagnostic imaging
Prostate - radiation effects
Prostatic Neoplasms - diagnostic imaging
Prostatic Neoplasms - radiotherapy
Radiotherapy Dosage
Radiotherapy, Intensity-Modulated
Statistics, Nonparametric
Tomography, X-Ray Computed - methods
Urinary Bladder - diagnostic imaging
Urinary Bladder - radiation effects
title Evaluation of an application for intensity-based deformable image registration and dose accumulation in radiotherapy
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T05%3A05%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20an%20application%20for%20intensity-based%20deformable%20image%20registration%20and%20dose%20accumulation%20in%20radiotherapy&rft.jtitle=Acta%20oncologica&rft.au=Thor,%20Maria&rft.date=2014-10-01&rft.volume=53&rft.issue=10&rft.spage=1329&rft.epage=1336&rft.pages=1329-1336&rft.issn=0284-186X&rft.eissn=1651-226X&rft_id=info:doi/10.3109/0284186X.2014.928742&rft_dat=%3Cproquest_cross%3E1614694289%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1614694289&rft_id=info:pmid/24957554&rfr_iscdi=true