Determination of Aliphatic Amines in Water Using Derivatization with Fluorescein Isothiocyanate and Capillary Electrophoresis/Laser-Induced Fluorescence Detection
Detection-oriented derivatization of aliphatic amines and amine functional groups in compounds of environmental interest was studied using fluorescein isothiocyanate (FITC) with separation/determination by capillary electrophoresis/laser-induced fluorescence. Determinative levels down to 10 ppb were...
Gespeichert in:
Veröffentlicht in: | Journal of liquid chromatography & related technologies 1997-01, Vol.20 (14), p.2193-2205 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 2205 |
---|---|
container_issue | 14 |
container_start_page | 2193 |
container_title | Journal of liquid chromatography & related technologies |
container_volume | 20 |
creator | Brumley, W. C. Kelliher, V. |
description | Detection-oriented derivatization of aliphatic amines and amine functional groups in compounds of environmental interest was studied using fluorescein isothiocyanate (FITC) with separation/determination by capillary electrophoresis/laser-induced fluorescence. Determinative levels down to 10 ppb were studied in deionized and environmental waters. Practical detection limits of 30 to 100 ppb or more were realized, depending on analyte and water source. Criteria were developed to compare results to desired performance in a derivatization method. FITC was judged to be a moderately successful reagent with drawbacks including extensive by-products, lack of specificity to analyte class, requirement to study each potential analyte carefully, and derivatization limits near 30 ppb. Advantages include low cost of reagent, ease in handling, and synthesis of an ionized derivative for free zone electrophoresis. |
doi_str_mv | 10.1080/10826079708006556 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_16032470</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>16032470</sourcerecordid><originalsourceid>FETCH-LOGICAL-c404t-b2a9b2419b536474b859f7a9f9b904d730ddb18b9f7bb5038b7f563cd37f661c3</originalsourceid><addsrcrecordid>eNqFkc1u3CAUha2okZImfYDuWFTduQHbgC11M5r8dKSRskmU7CzA0KFiwAUm08nj5ElzrUnbRRRlA9x7v3M4iKL4TPA3glt8BkvFMO84FJhRyg6KY0IrXFJe3X-AM8xLANhR8TGlXxgTTit6XDyd66zj2nqRbfAoGDRzdlxBpdAM2joh69GdAAjdJut_onMd7QPMH_eKrc0rdOk2IeqkNLCLFPLKBrUT4KmR8AOai9E6J-IOXTitcgzjasJtOluKpGO58MNG6eG_jVcaTcHUdMVpcWiES_rTy35S3F5e3Mx_lMvrq8V8tixVg5tcykp0smpIJ2nNGt7IlnaGi850ssPNwGs8DJK0EppSUly3khvKajXU3DBGVH1SfN37jjH83uiU-7WFLBDc67BJPWG4rhqOASR7UMWQUtSmH6Ndw_N6gvvpN_pXvwGaLy_mIinhTBRe2fRPWLUMMzJZ8z1mvQlxLbYhuqHPYudC_Kt5Zd7nPxmU399V1m_newYkLbL-</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>16032470</pqid></control><display><type>article</type><title>Determination of Aliphatic Amines in Water Using Derivatization with Fluorescein Isothiocyanate and Capillary Electrophoresis/Laser-Induced Fluorescence Detection</title><source>Taylor & Francis:Master (3349 titles)</source><creator>Brumley, W. C. ; Kelliher, V.</creator><creatorcontrib>Brumley, W. C. ; Kelliher, V.</creatorcontrib><description>Detection-oriented derivatization of aliphatic amines and amine functional groups in compounds of environmental interest was studied using fluorescein isothiocyanate (FITC) with separation/determination by capillary electrophoresis/laser-induced fluorescence. Determinative levels down to 10 ppb were studied in deionized and environmental waters. Practical detection limits of 30 to 100 ppb or more were realized, depending on analyte and water source. Criteria were developed to compare results to desired performance in a derivatization method. FITC was judged to be a moderately successful reagent with drawbacks including extensive by-products, lack of specificity to analyte class, requirement to study each potential analyte carefully, and derivatization limits near 30 ppb. Advantages include low cost of reagent, ease in handling, and synthesis of an ionized derivative for free zone electrophoresis.</description><identifier>ISSN: 1082-6076</identifier><identifier>EISSN: 1520-572X</identifier><identifier>DOI: 10.1080/10826079708006556</identifier><identifier>CODEN: JLCTFC</identifier><language>eng</language><publisher>Colchester: Taylor & Francis Group</publisher><subject>Analysis methods ; Analytical chemistry ; Applied sciences ; Chemistry ; Chromatographic methods and physical methods associated with chromatography ; Exact sciences and technology ; Freshwater ; Natural water pollution ; Other chromatographic methods ; Pollution ; Water treatment and pollution</subject><ispartof>Journal of liquid chromatography & related technologies, 1997-01, Vol.20 (14), p.2193-2205</ispartof><rights>Copyright Taylor & Francis Group, LLC 1997</rights><rights>1997 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c404t-b2a9b2419b536474b859f7a9f9b904d730ddb18b9f7bb5038b7f563cd37f661c3</citedby><cites>FETCH-LOGICAL-c404t-b2a9b2419b536474b859f7a9f9b904d730ddb18b9f7bb5038b7f563cd37f661c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.tandfonline.com/doi/pdf/10.1080/10826079708006556$$EPDF$$P50$$Ginformaworld$$H</linktopdf><linktohtml>$$Uhttps://www.tandfonline.com/doi/full/10.1080/10826079708006556$$EHTML$$P50$$Ginformaworld$$H</linktohtml><link.rule.ids>314,776,780,27901,27902,59620,60409</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=2860610$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Brumley, W. C.</creatorcontrib><creatorcontrib>Kelliher, V.</creatorcontrib><title>Determination of Aliphatic Amines in Water Using Derivatization with Fluorescein Isothiocyanate and Capillary Electrophoresis/Laser-Induced Fluorescence Detection</title><title>Journal of liquid chromatography & related technologies</title><description>Detection-oriented derivatization of aliphatic amines and amine functional groups in compounds of environmental interest was studied using fluorescein isothiocyanate (FITC) with separation/determination by capillary electrophoresis/laser-induced fluorescence. Determinative levels down to 10 ppb were studied in deionized and environmental waters. Practical detection limits of 30 to 100 ppb or more were realized, depending on analyte and water source. Criteria were developed to compare results to desired performance in a derivatization method. FITC was judged to be a moderately successful reagent with drawbacks including extensive by-products, lack of specificity to analyte class, requirement to study each potential analyte carefully, and derivatization limits near 30 ppb. Advantages include low cost of reagent, ease in handling, and synthesis of an ionized derivative for free zone electrophoresis.</description><subject>Analysis methods</subject><subject>Analytical chemistry</subject><subject>Applied sciences</subject><subject>Chemistry</subject><subject>Chromatographic methods and physical methods associated with chromatography</subject><subject>Exact sciences and technology</subject><subject>Freshwater</subject><subject>Natural water pollution</subject><subject>Other chromatographic methods</subject><subject>Pollution</subject><subject>Water treatment and pollution</subject><issn>1082-6076</issn><issn>1520-572X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1997</creationdate><recordtype>article</recordtype><recordid>eNqFkc1u3CAUha2okZImfYDuWFTduQHbgC11M5r8dKSRskmU7CzA0KFiwAUm08nj5ElzrUnbRRRlA9x7v3M4iKL4TPA3glt8BkvFMO84FJhRyg6KY0IrXFJe3X-AM8xLANhR8TGlXxgTTit6XDyd66zj2nqRbfAoGDRzdlxBpdAM2joh69GdAAjdJut_onMd7QPMH_eKrc0rdOk2IeqkNLCLFPLKBrUT4KmR8AOai9E6J-IOXTitcgzjasJtOluKpGO58MNG6eG_jVcaTcHUdMVpcWiES_rTy35S3F5e3Mx_lMvrq8V8tixVg5tcykp0smpIJ2nNGt7IlnaGi850ssPNwGs8DJK0EppSUly3khvKajXU3DBGVH1SfN37jjH83uiU-7WFLBDc67BJPWG4rhqOASR7UMWQUtSmH6Ndw_N6gvvpN_pXvwGaLy_mIinhTBRe2fRPWLUMMzJZ8z1mvQlxLbYhuqHPYudC_Kt5Zd7nPxmU399V1m_newYkLbL-</recordid><startdate>19970101</startdate><enddate>19970101</enddate><creator>Brumley, W. C.</creator><creator>Kelliher, V.</creator><general>Taylor & Francis Group</general><general>Taylor & Francis</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7TV</scope><scope>7UA</scope><scope>C1K</scope><scope>F1W</scope><scope>H97</scope><scope>L.G</scope></search><sort><creationdate>19970101</creationdate><title>Determination of Aliphatic Amines in Water Using Derivatization with Fluorescein Isothiocyanate and Capillary Electrophoresis/Laser-Induced Fluorescence Detection</title><author>Brumley, W. C. ; Kelliher, V.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c404t-b2a9b2419b536474b859f7a9f9b904d730ddb18b9f7bb5038b7f563cd37f661c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1997</creationdate><topic>Analysis methods</topic><topic>Analytical chemistry</topic><topic>Applied sciences</topic><topic>Chemistry</topic><topic>Chromatographic methods and physical methods associated with chromatography</topic><topic>Exact sciences and technology</topic><topic>Freshwater</topic><topic>Natural water pollution</topic><topic>Other chromatographic methods</topic><topic>Pollution</topic><topic>Water treatment and pollution</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Brumley, W. C.</creatorcontrib><creatorcontrib>Kelliher, V.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Pollution Abstracts</collection><collection>Water Resources Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ASFA: Aquatic Sciences and Fisheries Abstracts</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) 3: Aquatic Pollution & Environmental Quality</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) Professional</collection><jtitle>Journal of liquid chromatography & related technologies</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Brumley, W. C.</au><au>Kelliher, V.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of Aliphatic Amines in Water Using Derivatization with Fluorescein Isothiocyanate and Capillary Electrophoresis/Laser-Induced Fluorescence Detection</atitle><jtitle>Journal of liquid chromatography & related technologies</jtitle><date>1997-01-01</date><risdate>1997</risdate><volume>20</volume><issue>14</issue><spage>2193</spage><epage>2205</epage><pages>2193-2205</pages><issn>1082-6076</issn><eissn>1520-572X</eissn><coden>JLCTFC</coden><abstract>Detection-oriented derivatization of aliphatic amines and amine functional groups in compounds of environmental interest was studied using fluorescein isothiocyanate (FITC) with separation/determination by capillary electrophoresis/laser-induced fluorescence. Determinative levels down to 10 ppb were studied in deionized and environmental waters. Practical detection limits of 30 to 100 ppb or more were realized, depending on analyte and water source. Criteria were developed to compare results to desired performance in a derivatization method. FITC was judged to be a moderately successful reagent with drawbacks including extensive by-products, lack of specificity to analyte class, requirement to study each potential analyte carefully, and derivatization limits near 30 ppb. Advantages include low cost of reagent, ease in handling, and synthesis of an ionized derivative for free zone electrophoresis.</abstract><cop>Colchester</cop><pub>Taylor & Francis Group</pub><doi>10.1080/10826079708006556</doi><tpages>13</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1082-6076 |
ispartof | Journal of liquid chromatography & related technologies, 1997-01, Vol.20 (14), p.2193-2205 |
issn | 1082-6076 1520-572X |
language | eng |
recordid | cdi_proquest_miscellaneous_16032470 |
source | Taylor & Francis:Master (3349 titles) |
subjects | Analysis methods Analytical chemistry Applied sciences Chemistry Chromatographic methods and physical methods associated with chromatography Exact sciences and technology Freshwater Natural water pollution Other chromatographic methods Pollution Water treatment and pollution |
title | Determination of Aliphatic Amines in Water Using Derivatization with Fluorescein Isothiocyanate and Capillary Electrophoresis/Laser-Induced Fluorescence Detection |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-15T02%3A02%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%20Aliphatic%20Amines%20in%20Water%20Using%20Derivatization%20with%20Fluorescein%20Isothiocyanate%20and%20Capillary%20Electrophoresis/Laser-Induced%20Fluorescence%20Detection&rft.jtitle=Journal%20of%20liquid%20chromatography%20&%20related%20technologies&rft.au=Brumley,%20W.%20C.&rft.date=1997-01-01&rft.volume=20&rft.issue=14&rft.spage=2193&rft.epage=2205&rft.pages=2193-2205&rft.issn=1082-6076&rft.eissn=1520-572X&rft.coden=JLCTFC&rft_id=info:doi/10.1080/10826079708006556&rft_dat=%3Cproquest_cross%3E16032470%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=16032470&rft_id=info:pmid/&rfr_iscdi=true |