Development of a hygiene standard for raw milk based on the Lumac ATP-bioluminescence method
A practical and reliable ‘standard’ has been derived to enable the use of ATP-bioluminescence as a screening test for assessing the hygienic quality of raw cows' milk. A total of 712 ex-farm bulk tank milk samples were examined using both the Lumac ATP-bioluminescence method and the total micro...
Gespeichert in:
Veröffentlicht in: | International dairy journal 1996, Vol.6 (7), p.709-713 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 713 |
---|---|
container_issue | 7 |
container_start_page | 709 |
container_title | International dairy journal |
container_volume | 6 |
creator | Bell, C. Bowles, C.D. Toszeghy, M.J.K. Neaves, P. |
description | A practical and reliable ‘standard’ has been derived to enable the use of ATP-bioluminescence as a screening test for assessing the hygienic quality of raw cows' milk. A total of 712 ex-farm bulk tank milk samples were examined using both the Lumac ATP-bioluminescence method and the total microbial colony count method. No samples were treated in any way to create artificially high or low counts. Using the Lumac Raw Milk Microbial kit and the Lumac 2500 instrument, an ATP reading of 5700 can be used as a qualitative ‘cut-off value’ at a 95% confidence level to classify UK raw milks with total bacterial counts greater than or less than 10
5 cfu mL
−1. The measurement of ATP to reliably assess the hygienic quality of raw milk provides a powerful management tool for improving the use of this valuable raw material. |
doi_str_mv | 10.1016/0958-6946(96)00007-6 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_15788378</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0958694696000076</els_id><sourcerecordid>15788378</sourcerecordid><originalsourceid>FETCH-LOGICAL-c335t-6664d1b719f9e3994250b1b98ffe3699623b1a8f75d713568112fe8d8baae5253</originalsourceid><addsrcrecordid>eNp9kE9LxDAQxYMouK5-Aw85iR6qyaZJk4uw-B8W9LDehJA2EzfaNmvSruy3t2XFo3MZBt57zPshdErJJSVUXBHFZSZULs6VuCDDFJnYQxMqC5URmrN9NPmTHKKjlD4IoQVhaoLebmEDdVg30HY4OGzwavvuoQWcOtNaEy12IeJovnHj609cmgQWhxZ3K8CLvjEVni9fstKHum98C6mCtgLcQLcK9hgdOFMnOPndU_R6f7e8ecwWzw9PN_NFVjHGu0wIkVtaFlQ5BUypfMZJSUslnQMmlBIzVlIjXcFtQRkXktKZA2llaQzwGWdTdLbLXcfw1UPqdOOHR-ratBD6pCkvpGSFHIT5TljFkFIEp9fRNyZuNSV6RKlHTnrkpNVwjCi1GGzXOxsMJTYeok6VH3taH6HqtA3-_4Afg6Z6TA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>15788378</pqid></control><display><type>article</type><title>Development of a hygiene standard for raw milk based on the Lumac ATP-bioluminescence method</title><source>Elsevier ScienceDirect Journals</source><creator>Bell, C. ; Bowles, C.D. ; Toszeghy, M.J.K. ; Neaves, P.</creator><creatorcontrib>Bell, C. ; Bowles, C.D. ; Toszeghy, M.J.K. ; Neaves, P.</creatorcontrib><description>A practical and reliable ‘standard’ has been derived to enable the use of ATP-bioluminescence as a screening test for assessing the hygienic quality of raw cows' milk. A total of 712 ex-farm bulk tank milk samples were examined using both the Lumac ATP-bioluminescence method and the total microbial colony count method. No samples were treated in any way to create artificially high or low counts. Using the Lumac Raw Milk Microbial kit and the Lumac 2500 instrument, an ATP reading of 5700 can be used as a qualitative ‘cut-off value’ at a 95% confidence level to classify UK raw milks with total bacterial counts greater than or less than 10
5 cfu mL
−1. The measurement of ATP to reliably assess the hygienic quality of raw milk provides a powerful management tool for improving the use of this valuable raw material.</description><identifier>ISSN: 0958-6946</identifier><identifier>EISSN: 1879-0143</identifier><identifier>DOI: 10.1016/0958-6946(96)00007-6</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><ispartof>International dairy journal, 1996, Vol.6 (7), p.709-713</ispartof><rights>1996</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c335t-6664d1b719f9e3994250b1b98ffe3699623b1a8f75d713568112fe8d8baae5253</citedby><cites>FETCH-LOGICAL-c335t-6664d1b719f9e3994250b1b98ffe3699623b1a8f75d713568112fe8d8baae5253</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/0958694696000076$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,4010,27900,27901,27902,65306</link.rule.ids></links><search><creatorcontrib>Bell, C.</creatorcontrib><creatorcontrib>Bowles, C.D.</creatorcontrib><creatorcontrib>Toszeghy, M.J.K.</creatorcontrib><creatorcontrib>Neaves, P.</creatorcontrib><title>Development of a hygiene standard for raw milk based on the Lumac ATP-bioluminescence method</title><title>International dairy journal</title><description>A practical and reliable ‘standard’ has been derived to enable the use of ATP-bioluminescence as a screening test for assessing the hygienic quality of raw cows' milk. A total of 712 ex-farm bulk tank milk samples were examined using both the Lumac ATP-bioluminescence method and the total microbial colony count method. No samples were treated in any way to create artificially high or low counts. Using the Lumac Raw Milk Microbial kit and the Lumac 2500 instrument, an ATP reading of 5700 can be used as a qualitative ‘cut-off value’ at a 95% confidence level to classify UK raw milks with total bacterial counts greater than or less than 10
5 cfu mL
−1. The measurement of ATP to reliably assess the hygienic quality of raw milk provides a powerful management tool for improving the use of this valuable raw material.</description><issn>0958-6946</issn><issn>1879-0143</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1996</creationdate><recordtype>article</recordtype><recordid>eNp9kE9LxDAQxYMouK5-Aw85iR6qyaZJk4uw-B8W9LDehJA2EzfaNmvSruy3t2XFo3MZBt57zPshdErJJSVUXBHFZSZULs6VuCDDFJnYQxMqC5URmrN9NPmTHKKjlD4IoQVhaoLebmEDdVg30HY4OGzwavvuoQWcOtNaEy12IeJovnHj609cmgQWhxZ3K8CLvjEVni9fstKHum98C6mCtgLcQLcK9hgdOFMnOPndU_R6f7e8ecwWzw9PN_NFVjHGu0wIkVtaFlQ5BUypfMZJSUslnQMmlBIzVlIjXcFtQRkXktKZA2llaQzwGWdTdLbLXcfw1UPqdOOHR-ratBD6pCkvpGSFHIT5TljFkFIEp9fRNyZuNSV6RKlHTnrkpNVwjCi1GGzXOxsMJTYeok6VH3taH6HqtA3-_4Afg6Z6TA</recordid><startdate>1996</startdate><enddate>1996</enddate><creator>Bell, C.</creator><creator>Bowles, C.D.</creator><creator>Toszeghy, M.J.K.</creator><creator>Neaves, P.</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7T7</scope><scope>8FD</scope><scope>C1K</scope><scope>FR3</scope><scope>P64</scope></search><sort><creationdate>1996</creationdate><title>Development of a hygiene standard for raw milk based on the Lumac ATP-bioluminescence method</title><author>Bell, C. ; Bowles, C.D. ; Toszeghy, M.J.K. ; Neaves, P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c335t-6664d1b719f9e3994250b1b98ffe3699623b1a8f75d713568112fe8d8baae5253</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1996</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bell, C.</creatorcontrib><creatorcontrib>Bowles, C.D.</creatorcontrib><creatorcontrib>Toszeghy, M.J.K.</creatorcontrib><creatorcontrib>Neaves, P.</creatorcontrib><collection>CrossRef</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>International dairy journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bell, C.</au><au>Bowles, C.D.</au><au>Toszeghy, M.J.K.</au><au>Neaves, P.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of a hygiene standard for raw milk based on the Lumac ATP-bioluminescence method</atitle><jtitle>International dairy journal</jtitle><date>1996</date><risdate>1996</risdate><volume>6</volume><issue>7</issue><spage>709</spage><epage>713</epage><pages>709-713</pages><issn>0958-6946</issn><eissn>1879-0143</eissn><abstract>A practical and reliable ‘standard’ has been derived to enable the use of ATP-bioluminescence as a screening test for assessing the hygienic quality of raw cows' milk. A total of 712 ex-farm bulk tank milk samples were examined using both the Lumac ATP-bioluminescence method and the total microbial colony count method. No samples were treated in any way to create artificially high or low counts. Using the Lumac Raw Milk Microbial kit and the Lumac 2500 instrument, an ATP reading of 5700 can be used as a qualitative ‘cut-off value’ at a 95% confidence level to classify UK raw milks with total bacterial counts greater than or less than 10
5 cfu mL
−1. The measurement of ATP to reliably assess the hygienic quality of raw milk provides a powerful management tool for improving the use of this valuable raw material.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/0958-6946(96)00007-6</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0958-6946 |
ispartof | International dairy journal, 1996, Vol.6 (7), p.709-713 |
issn | 0958-6946 1879-0143 |
language | eng |
recordid | cdi_proquest_miscellaneous_15788378 |
source | Elsevier ScienceDirect Journals |
title | Development of a hygiene standard for raw milk based on the Lumac ATP-bioluminescence method |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T08%3A45%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20a%20hygiene%20standard%20for%20raw%20milk%20based%20on%20the%20Lumac%20ATP-bioluminescence%20method&rft.jtitle=International%20dairy%20journal&rft.au=Bell,%20C.&rft.date=1996&rft.volume=6&rft.issue=7&rft.spage=709&rft.epage=713&rft.pages=709-713&rft.issn=0958-6946&rft.eissn=1879-0143&rft_id=info:doi/10.1016/0958-6946(96)00007-6&rft_dat=%3Cproquest_cross%3E15788378%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=15788378&rft_id=info:pmid/&rft_els_id=0958694696000076&rfr_iscdi=true |