Transient analysis of converter-fed adjustable-speed generator-motor for the pumped storage power plant

A converter‐fed adjustable‐speed generator‐motor for a pumped storage power plant has been developed in order to contribute to the automatic frequency control on an electric power system during pumping operations, as well as to improve the efficiency of turbines during generating operations together...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Electrical engineering in Japan 1996, Vol.116 (2), p.63-76
Hauptverfasser: Yanagisawa, Tadahiro, Kageyama, Takahisa, Okamura, Kazuhiko, Kusunoki, Kiyoshi, Taguchi, Tadashi, Abe, Michiyuki, Kaneko, Hirokazu
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 76
container_issue 2
container_start_page 63
container_title Electrical engineering in Japan
container_volume 116
creator Yanagisawa, Tadahiro
Kageyama, Takahisa
Okamura, Kazuhiko
Kusunoki, Kiyoshi
Taguchi, Tadashi
Abe, Michiyuki
Kaneko, Hirokazu
description A converter‐fed adjustable‐speed generator‐motor for a pumped storage power plant has been developed in order to contribute to the automatic frequency control on an electric power system during pumping operations, as well as to improve the efficiency of turbines during generating operations together with stability. This system consists of a reversible pump turbine, a generator motor, cycloconverter and control units. The rotor of the generator motor, which is coupled directly with the turbine runner, normally is operated at a rotating speed which is equal to the difference between the frequency of the electric power system and that of the rotor current. In the state that a fault has occurred in the primary circuit of the generator motor, the adjustable‐speed generator‐motor fault current differs from that of a conventional synchronous generator motor. This paper describes the fault current analysis results for the condition when a sudden short‐circuit is made on the primary side of the generator motor, and collates the results with the field test and EMTP simulation results.
doi_str_mv 10.1002/eej.4391160206
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_15718900</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>221796</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3666-bd37a96f30f7283dc9d8789d5a5b6aaff873030e77d746d6b839449ea1ba12dd3</originalsourceid><addsrcrecordid>eNqFUMFO3DAQtSqQukCvPedQcfMyjhM7Pha0LFSIFomKozWJx9tss0mws9D9e1wtouLUw8xoZt57M3qMfRYwFwD5GdF6XkgjhIIc1Ac2E2UOXBVCHbAZFHnBtVbwkR3FuAYALXQ1Y6v7gH1sqZ8y7LHbxTZmg8-aoX-iMFHgnlyGbr2NE9Yd8ThSGqyop4DTEPhmSDnzKaZflI3bzZjWMc1wldrhmUI2dthPJ-zQYxfp02s9Zj8vF_cXV_zm-_L64usNb6RSitdOajTKS_A6r6RrjKt0ZVyJZa0Qva-0BAmktdOFcqqupCkKQyhqFLlz8pid7nXHMDxuKU5208aGuvQDDdtoRalFZQAScL4HNmGIMZC3Y2g3GHZWgP3rp01-2n9-JsKXV2WMDXY--da08Y0lQRnQVYKZPey57Wj3H1G7WHx7d4LvuW2c6M8bF8Nvq7TUpX24XdofS3NXnj_c2Vv5At1Xlz8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>15718900</pqid></control><display><type>article</type><title>Transient analysis of converter-fed adjustable-speed generator-motor for the pumped storage power plant</title><source>Access via Wiley Online Library</source><creator>Yanagisawa, Tadahiro ; Kageyama, Takahisa ; Okamura, Kazuhiko ; Kusunoki, Kiyoshi ; Taguchi, Tadashi ; Abe, Michiyuki ; Kaneko, Hirokazu</creator><creatorcontrib>Yanagisawa, Tadahiro ; Kageyama, Takahisa ; Okamura, Kazuhiko ; Kusunoki, Kiyoshi ; Taguchi, Tadashi ; Abe, Michiyuki ; Kaneko, Hirokazu</creatorcontrib><description>A converter‐fed adjustable‐speed generator‐motor for a pumped storage power plant has been developed in order to contribute to the automatic frequency control on an electric power system during pumping operations, as well as to improve the efficiency of turbines during generating operations together with stability. This system consists of a reversible pump turbine, a generator motor, cycloconverter and control units. The rotor of the generator motor, which is coupled directly with the turbine runner, normally is operated at a rotating speed which is equal to the difference between the frequency of the electric power system and that of the rotor current. In the state that a fault has occurred in the primary circuit of the generator motor, the adjustable‐speed generator‐motor fault current differs from that of a conventional synchronous generator motor. This paper describes the fault current analysis results for the condition when a sudden short‐circuit is made on the primary side of the generator motor, and collates the results with the field test and EMTP simulation results.</description><identifier>ISSN: 0424-7760</identifier><identifier>EISSN: 1520-6416</identifier><identifier>DOI: 10.1002/eej.4391160206</identifier><identifier>CODEN: EENJAU</identifier><language>eng</language><publisher>New York: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>Adjustable-speed pumped storage system ; Applied sciences ; cycloconverter ; Electrical engineering. Electrical power engineering ; Electrical machines ; Energy ; Energy. Thermal use of fuels ; Exact sciences and technology ; generator motor ; Hydroelectric power plants ; Installations for energy generation and conversion: thermal and electrical energy ; Regulation and control ; symmetrical component ; transient characteristics</subject><ispartof>Electrical engineering in Japan, 1996, Vol.116 (2), p.63-76</ispartof><rights>Copyright © 1996 Wiley Periodicals, Inc., A Wiley Company</rights><rights>1996 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3666-bd37a96f30f7283dc9d8789d5a5b6aaff873030e77d746d6b839449ea1ba12dd3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Feej.4391160206$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Feej.4391160206$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,4024,27923,27924,27925,45574,45575</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=3069078$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Yanagisawa, Tadahiro</creatorcontrib><creatorcontrib>Kageyama, Takahisa</creatorcontrib><creatorcontrib>Okamura, Kazuhiko</creatorcontrib><creatorcontrib>Kusunoki, Kiyoshi</creatorcontrib><creatorcontrib>Taguchi, Tadashi</creatorcontrib><creatorcontrib>Abe, Michiyuki</creatorcontrib><creatorcontrib>Kaneko, Hirokazu</creatorcontrib><title>Transient analysis of converter-fed adjustable-speed generator-motor for the pumped storage power plant</title><title>Electrical engineering in Japan</title><addtitle>Elect. Eng. Jpn</addtitle><description>A converter‐fed adjustable‐speed generator‐motor for a pumped storage power plant has been developed in order to contribute to the automatic frequency control on an electric power system during pumping operations, as well as to improve the efficiency of turbines during generating operations together with stability. This system consists of a reversible pump turbine, a generator motor, cycloconverter and control units. The rotor of the generator motor, which is coupled directly with the turbine runner, normally is operated at a rotating speed which is equal to the difference between the frequency of the electric power system and that of the rotor current. In the state that a fault has occurred in the primary circuit of the generator motor, the adjustable‐speed generator‐motor fault current differs from that of a conventional synchronous generator motor. This paper describes the fault current analysis results for the condition when a sudden short‐circuit is made on the primary side of the generator motor, and collates the results with the field test and EMTP simulation results.</description><subject>Adjustable-speed pumped storage system</subject><subject>Applied sciences</subject><subject>cycloconverter</subject><subject>Electrical engineering. Electrical power engineering</subject><subject>Electrical machines</subject><subject>Energy</subject><subject>Energy. Thermal use of fuels</subject><subject>Exact sciences and technology</subject><subject>generator motor</subject><subject>Hydroelectric power plants</subject><subject>Installations for energy generation and conversion: thermal and electrical energy</subject><subject>Regulation and control</subject><subject>symmetrical component</subject><subject>transient characteristics</subject><issn>0424-7760</issn><issn>1520-6416</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1996</creationdate><recordtype>article</recordtype><recordid>eNqFUMFO3DAQtSqQukCvPedQcfMyjhM7Pha0LFSIFomKozWJx9tss0mws9D9e1wtouLUw8xoZt57M3qMfRYwFwD5GdF6XkgjhIIc1Ac2E2UOXBVCHbAZFHnBtVbwkR3FuAYALXQ1Y6v7gH1sqZ8y7LHbxTZmg8-aoX-iMFHgnlyGbr2NE9Yd8ThSGqyop4DTEPhmSDnzKaZflI3bzZjWMc1wldrhmUI2dthPJ-zQYxfp02s9Zj8vF_cXV_zm-_L64usNb6RSitdOajTKS_A6r6RrjKt0ZVyJZa0Qva-0BAmktdOFcqqupCkKQyhqFLlz8pid7nXHMDxuKU5208aGuvQDDdtoRalFZQAScL4HNmGIMZC3Y2g3GHZWgP3rp01-2n9-JsKXV2WMDXY--da08Y0lQRnQVYKZPey57Wj3H1G7WHx7d4LvuW2c6M8bF8Nvq7TUpX24XdofS3NXnj_c2Vv5At1Xlz8</recordid><startdate>1996</startdate><enddate>1996</enddate><creator>Yanagisawa, Tadahiro</creator><creator>Kageyama, Takahisa</creator><creator>Okamura, Kazuhiko</creator><creator>Kusunoki, Kiyoshi</creator><creator>Taguchi, Tadashi</creator><creator>Abe, Michiyuki</creator><creator>Kaneko, Hirokazu</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><general>John Wiley &amp; Sons</general><scope>BSCLL</scope><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>1996</creationdate><title>Transient analysis of converter-fed adjustable-speed generator-motor for the pumped storage power plant</title><author>Yanagisawa, Tadahiro ; Kageyama, Takahisa ; Okamura, Kazuhiko ; Kusunoki, Kiyoshi ; Taguchi, Tadashi ; Abe, Michiyuki ; Kaneko, Hirokazu</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3666-bd37a96f30f7283dc9d8789d5a5b6aaff873030e77d746d6b839449ea1ba12dd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1996</creationdate><topic>Adjustable-speed pumped storage system</topic><topic>Applied sciences</topic><topic>cycloconverter</topic><topic>Electrical engineering. Electrical power engineering</topic><topic>Electrical machines</topic><topic>Energy</topic><topic>Energy. Thermal use of fuels</topic><topic>Exact sciences and technology</topic><topic>generator motor</topic><topic>Hydroelectric power plants</topic><topic>Installations for energy generation and conversion: thermal and electrical energy</topic><topic>Regulation and control</topic><topic>symmetrical component</topic><topic>transient characteristics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yanagisawa, Tadahiro</creatorcontrib><creatorcontrib>Kageyama, Takahisa</creatorcontrib><creatorcontrib>Okamura, Kazuhiko</creatorcontrib><creatorcontrib>Kusunoki, Kiyoshi</creatorcontrib><creatorcontrib>Taguchi, Tadashi</creatorcontrib><creatorcontrib>Abe, Michiyuki</creatorcontrib><creatorcontrib>Kaneko, Hirokazu</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>CrossRef</collection><jtitle>Electrical engineering in Japan</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yanagisawa, Tadahiro</au><au>Kageyama, Takahisa</au><au>Okamura, Kazuhiko</au><au>Kusunoki, Kiyoshi</au><au>Taguchi, Tadashi</au><au>Abe, Michiyuki</au><au>Kaneko, Hirokazu</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Transient analysis of converter-fed adjustable-speed generator-motor for the pumped storage power plant</atitle><jtitle>Electrical engineering in Japan</jtitle><addtitle>Elect. Eng. Jpn</addtitle><date>1996</date><risdate>1996</risdate><volume>116</volume><issue>2</issue><spage>63</spage><epage>76</epage><pages>63-76</pages><issn>0424-7760</issn><eissn>1520-6416</eissn><coden>EENJAU</coden><abstract>A converter‐fed adjustable‐speed generator‐motor for a pumped storage power plant has been developed in order to contribute to the automatic frequency control on an electric power system during pumping operations, as well as to improve the efficiency of turbines during generating operations together with stability. This system consists of a reversible pump turbine, a generator motor, cycloconverter and control units. The rotor of the generator motor, which is coupled directly with the turbine runner, normally is operated at a rotating speed which is equal to the difference between the frequency of the electric power system and that of the rotor current. In the state that a fault has occurred in the primary circuit of the generator motor, the adjustable‐speed generator‐motor fault current differs from that of a conventional synchronous generator motor. This paper describes the fault current analysis results for the condition when a sudden short‐circuit is made on the primary side of the generator motor, and collates the results with the field test and EMTP simulation results.</abstract><cop>New York</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><doi>10.1002/eej.4391160206</doi><tpages>14</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0424-7760
ispartof Electrical engineering in Japan, 1996, Vol.116 (2), p.63-76
issn 0424-7760
1520-6416
language eng
recordid cdi_proquest_miscellaneous_15718900
source Access via Wiley Online Library
subjects Adjustable-speed pumped storage system
Applied sciences
cycloconverter
Electrical engineering. Electrical power engineering
Electrical machines
Energy
Energy. Thermal use of fuels
Exact sciences and technology
generator motor
Hydroelectric power plants
Installations for energy generation and conversion: thermal and electrical energy
Regulation and control
symmetrical component
transient characteristics
title Transient analysis of converter-fed adjustable-speed generator-motor for the pumped storage power plant
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-21T10%3A00%3A21IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Transient%20analysis%20of%20converter-fed%20adjustable-speed%20generator-motor%20for%20the%20pumped%20storage%20power%20plant&rft.jtitle=Electrical%20engineering%20in%20Japan&rft.au=Yanagisawa,%20Tadahiro&rft.date=1996&rft.volume=116&rft.issue=2&rft.spage=63&rft.epage=76&rft.pages=63-76&rft.issn=0424-7760&rft.eissn=1520-6416&rft.coden=EENJAU&rft_id=info:doi/10.1002/eej.4391160206&rft_dat=%3Cproquest_cross%3E221796%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=15718900&rft_id=info:pmid/&rfr_iscdi=true