Survival and Long-term Outcomes Following Bioprosthetic vs Mechanical Aortic Valve Replacement in Patients Aged 50 to 69 Years
IMPORTANCE: The choice between bioprosthetic and mechanical aortic valve replacement in younger patients is controversial because long-term survival and major morbidity are poorly characterized. OBJECTIVE: To quantify survival and major morbidity in patients aged 50 to 69 years undergoing aortic val...
Gespeichert in:
Veröffentlicht in: | JAMA : the journal of the American Medical Association 2014-10, Vol.312 (13), p.1323-1329 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1329 |
---|---|
container_issue | 13 |
container_start_page | 1323 |
container_title | JAMA : the journal of the American Medical Association |
container_volume | 312 |
creator | Chiang, Yuting P Chikwe, Joanna Moskowitz, Alan J Itagaki, Shinobu Adams, David H Egorova, Natalia N |
description | IMPORTANCE: The choice between bioprosthetic and mechanical aortic valve replacement in younger patients is controversial because long-term survival and major morbidity are poorly characterized. OBJECTIVE: To quantify survival and major morbidity in patients aged 50 to 69 years undergoing aortic valve replacement. DESIGN, SETTING, AND PARTICIPANTS: Retrospective cohort analysis of 4253 patients aged 50 to 69 years who underwent primary isolated aortic valve replacement using bioprosthetic vs mechanical valves in New York State from 1997 through 2004, identified using the Statewide Planning and Research Cooperative System. Median follow-up time was 10.8 years (range, 0 to 16.9 years); the last follow-up date for mortality was November 30, 2013. Propensity matching yielded 1001 patient pairs. MAIN OUTCOMES AND MEASURES: Primary outcome was all-cause mortality; secondary outcomes were stroke, reoperation, and major bleeding. RESULTS: No differences in survival or stroke rates were observed in patients with bioprosthetic compared with mechanical valves. Actuarial 15-year survival was 60.6% (95% CI, 56.3%-64.9%) in the bioprosthesis group compared with 62.1% (95% CI, 58.2%-66.0%) in the mechanical prosthesis group (hazard ratio, 0.97 [95% CI, 0.83-1.14]). The 15-year cumulative incidence of stroke was 7.7% (95% CI, 5.7%-9.7%) in the bioprosthesis group and 8.6% (95% CI, 6.2%-11.0%) in the mechanical prosthesis group (hazard ratio, 1.04 [95% CI, 0.75-1.43). The 15-year cumulative incidence of reoperation was higher in the bioprosthesis group (12.1% [95% CI, 8.8%-15.4%] vs 6.9% [95% CI, 4.2%-9.6%]; hazard ratio, 0.52 [95% CI, 0.36-0.75]). The 15-year cumulative incidence of major bleeding was higher in the mechanical prosthesis group (13.0% [95% CI, 9.9%-16.1%] vs 6.6% [95% CI, 4.8%-8.4%]; hazard ratio, 1.75 [95% CI, 1.27-2.43]). The 30-day mortality rate was 18.7% after stroke, 9.0% after reoperation, and 13.2% after major bleeding. CONCLUSIONS AND RELEVANCE: Among propensity-matched patients aged 50 to 69 years who underwent aortic valve replacement with bioprosthetic compared with mechanical valves, there was no significant difference in 15-year survival or stroke. Patients in the bioprosthetic valve group had a greater likelihood of reoperation but a lower likelihood of major bleeding. These findings suggest that bioprosthetic valves may be a reasonable choice in patients aged 50 to 69 years. |
doi_str_mv | 10.1001/jama.2014.12679 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1567051387</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ama_id>1910112</ama_id><sourcerecordid>3462329161</sourcerecordid><originalsourceid>FETCH-LOGICAL-a497t-d5b8dded9805b6b0f9fde8e80b675a380a8d3f882a4ad44c7538fa5893ad3fe43</originalsourceid><addsrcrecordid>eNpdkc1v1DAQxS0EokvhjMQBWeLCJVs7tmP7uFQUkBYV8SVxsibxZOtVEm_jZBEX_nYctvTAXDwa_d6zPY-Q55ytOWP8Yg89rEvG5ZqXlbYPyIorYQqhrHlIVoxZU2hp5Bl5ktKe5eJCPyZnpSorI4Vdkd9f5vEYjtBRGDzdxmFXTDj29Hqemthjolex6-LPMOzomxAPY0zTDU6hocdEP2JzA0NosngTx2X4Hboj0s946KDBHoeJhoF-ginkNtHNDj1VjE6RVpb-QBjTU_KohS7hs7vznHy7evv18n2xvX734XKzLUBaPRVe1cZ79NYwVVc1a23r0aBhdaUVCMPAeNEaU4IEL2Wj8xJaUMYKyHOU4py8PvnmH9zOmCbXh9Rg18GAcU6Oq0ozxYXRGX31H7qP8zjk1zle8VJwqznP1MWJavJK0oitO4yhh_GX48wt0bglGrdE4_5GkxUv73znukd_z__LIgMvTsAivHeznPF86x_JQpLL</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1612319711</pqid></control><display><type>article</type><title>Survival and Long-term Outcomes Following Bioprosthetic vs Mechanical Aortic Valve Replacement in Patients Aged 50 to 69 Years</title><source>MEDLINE</source><source>American Medical Association Journals</source><creator>Chiang, Yuting P ; Chikwe, Joanna ; Moskowitz, Alan J ; Itagaki, Shinobu ; Adams, David H ; Egorova, Natalia N</creator><creatorcontrib>Chiang, Yuting P ; Chikwe, Joanna ; Moskowitz, Alan J ; Itagaki, Shinobu ; Adams, David H ; Egorova, Natalia N</creatorcontrib><description>IMPORTANCE: The choice between bioprosthetic and mechanical aortic valve replacement in younger patients is controversial because long-term survival and major morbidity are poorly characterized. OBJECTIVE: To quantify survival and major morbidity in patients aged 50 to 69 years undergoing aortic valve replacement. DESIGN, SETTING, AND PARTICIPANTS: Retrospective cohort analysis of 4253 patients aged 50 to 69 years who underwent primary isolated aortic valve replacement using bioprosthetic vs mechanical valves in New York State from 1997 through 2004, identified using the Statewide Planning and Research Cooperative System. Median follow-up time was 10.8 years (range, 0 to 16.9 years); the last follow-up date for mortality was November 30, 2013. Propensity matching yielded 1001 patient pairs. MAIN OUTCOMES AND MEASURES: Primary outcome was all-cause mortality; secondary outcomes were stroke, reoperation, and major bleeding. RESULTS: No differences in survival or stroke rates were observed in patients with bioprosthetic compared with mechanical valves. Actuarial 15-year survival was 60.6% (95% CI, 56.3%-64.9%) in the bioprosthesis group compared with 62.1% (95% CI, 58.2%-66.0%) in the mechanical prosthesis group (hazard ratio, 0.97 [95% CI, 0.83-1.14]). The 15-year cumulative incidence of stroke was 7.7% (95% CI, 5.7%-9.7%) in the bioprosthesis group and 8.6% (95% CI, 6.2%-11.0%) in the mechanical prosthesis group (hazard ratio, 1.04 [95% CI, 0.75-1.43). The 15-year cumulative incidence of reoperation was higher in the bioprosthesis group (12.1% [95% CI, 8.8%-15.4%] vs 6.9% [95% CI, 4.2%-9.6%]; hazard ratio, 0.52 [95% CI, 0.36-0.75]). The 15-year cumulative incidence of major bleeding was higher in the mechanical prosthesis group (13.0% [95% CI, 9.9%-16.1%] vs 6.6% [95% CI, 4.8%-8.4%]; hazard ratio, 1.75 [95% CI, 1.27-2.43]). The 30-day mortality rate was 18.7% after stroke, 9.0% after reoperation, and 13.2% after major bleeding. CONCLUSIONS AND RELEVANCE: Among propensity-matched patients aged 50 to 69 years who underwent aortic valve replacement with bioprosthetic compared with mechanical valves, there was no significant difference in 15-year survival or stroke. Patients in the bioprosthetic valve group had a greater likelihood of reoperation but a lower likelihood of major bleeding. These findings suggest that bioprosthetic valves may be a reasonable choice in patients aged 50 to 69 years.</description><identifier>ISSN: 0098-7484</identifier><identifier>EISSN: 1538-3598</identifier><identifier>DOI: 10.1001/jama.2014.12679</identifier><identifier>PMID: 25268439</identifier><identifier>CODEN: JAMAAP</identifier><language>eng</language><publisher>United States: American Medical Association</publisher><subject>Aged ; Aortic Valve - surgery ; Bioprosthesis - adverse effects ; Female ; Follow-Up Studies ; Heart surgery ; Heart Valve Prosthesis - adverse effects ; Heart Valve Prosthesis Implantation - mortality ; Hemorrhage - epidemiology ; Hemorrhage - etiology ; Humans ; Incidence ; Male ; Medical research ; Middle Aged ; Older people ; Patient safety ; Propensity Score ; Prosthesis Design ; Reoperation - mortality ; Retrospective Studies ; Stroke - epidemiology ; Stroke - etiology ; Surgical outcomes ; Survival Analysis</subject><ispartof>JAMA : the journal of the American Medical Association, 2014-10, Vol.312 (13), p.1323-1329</ispartof><rights>Copyright American Medical Association Oct 1, 2014</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a497t-d5b8dded9805b6b0f9fde8e80b675a380a8d3f882a4ad44c7538fa5893ad3fe43</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://jamanetwork.com/journals/jama/articlepdf/10.1001/jama.2014.12679$$EPDF$$P50$$Gama$$H</linktopdf><linktohtml>$$Uhttps://jamanetwork.com/journals/jama/fullarticle/10.1001/jama.2014.12679$$EHTML$$P50$$Gama$$H</linktohtml><link.rule.ids>64,314,776,780,3327,27901,27902,76232,76235</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25268439$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Chiang, Yuting P</creatorcontrib><creatorcontrib>Chikwe, Joanna</creatorcontrib><creatorcontrib>Moskowitz, Alan J</creatorcontrib><creatorcontrib>Itagaki, Shinobu</creatorcontrib><creatorcontrib>Adams, David H</creatorcontrib><creatorcontrib>Egorova, Natalia N</creatorcontrib><title>Survival and Long-term Outcomes Following Bioprosthetic vs Mechanical Aortic Valve Replacement in Patients Aged 50 to 69 Years</title><title>JAMA : the journal of the American Medical Association</title><addtitle>JAMA</addtitle><description>IMPORTANCE: The choice between bioprosthetic and mechanical aortic valve replacement in younger patients is controversial because long-term survival and major morbidity are poorly characterized. OBJECTIVE: To quantify survival and major morbidity in patients aged 50 to 69 years undergoing aortic valve replacement. DESIGN, SETTING, AND PARTICIPANTS: Retrospective cohort analysis of 4253 patients aged 50 to 69 years who underwent primary isolated aortic valve replacement using bioprosthetic vs mechanical valves in New York State from 1997 through 2004, identified using the Statewide Planning and Research Cooperative System. Median follow-up time was 10.8 years (range, 0 to 16.9 years); the last follow-up date for mortality was November 30, 2013. Propensity matching yielded 1001 patient pairs. MAIN OUTCOMES AND MEASURES: Primary outcome was all-cause mortality; secondary outcomes were stroke, reoperation, and major bleeding. RESULTS: No differences in survival or stroke rates were observed in patients with bioprosthetic compared with mechanical valves. Actuarial 15-year survival was 60.6% (95% CI, 56.3%-64.9%) in the bioprosthesis group compared with 62.1% (95% CI, 58.2%-66.0%) in the mechanical prosthesis group (hazard ratio, 0.97 [95% CI, 0.83-1.14]). The 15-year cumulative incidence of stroke was 7.7% (95% CI, 5.7%-9.7%) in the bioprosthesis group and 8.6% (95% CI, 6.2%-11.0%) in the mechanical prosthesis group (hazard ratio, 1.04 [95% CI, 0.75-1.43). The 15-year cumulative incidence of reoperation was higher in the bioprosthesis group (12.1% [95% CI, 8.8%-15.4%] vs 6.9% [95% CI, 4.2%-9.6%]; hazard ratio, 0.52 [95% CI, 0.36-0.75]). The 15-year cumulative incidence of major bleeding was higher in the mechanical prosthesis group (13.0% [95% CI, 9.9%-16.1%] vs 6.6% [95% CI, 4.8%-8.4%]; hazard ratio, 1.75 [95% CI, 1.27-2.43]). The 30-day mortality rate was 18.7% after stroke, 9.0% after reoperation, and 13.2% after major bleeding. CONCLUSIONS AND RELEVANCE: Among propensity-matched patients aged 50 to 69 years who underwent aortic valve replacement with bioprosthetic compared with mechanical valves, there was no significant difference in 15-year survival or stroke. Patients in the bioprosthetic valve group had a greater likelihood of reoperation but a lower likelihood of major bleeding. These findings suggest that bioprosthetic valves may be a reasonable choice in patients aged 50 to 69 years.</description><subject>Aged</subject><subject>Aortic Valve - surgery</subject><subject>Bioprosthesis - adverse effects</subject><subject>Female</subject><subject>Follow-Up Studies</subject><subject>Heart surgery</subject><subject>Heart Valve Prosthesis - adverse effects</subject><subject>Heart Valve Prosthesis Implantation - mortality</subject><subject>Hemorrhage - epidemiology</subject><subject>Hemorrhage - etiology</subject><subject>Humans</subject><subject>Incidence</subject><subject>Male</subject><subject>Medical research</subject><subject>Middle Aged</subject><subject>Older people</subject><subject>Patient safety</subject><subject>Propensity Score</subject><subject>Prosthesis Design</subject><subject>Reoperation - mortality</subject><subject>Retrospective Studies</subject><subject>Stroke - epidemiology</subject><subject>Stroke - etiology</subject><subject>Surgical outcomes</subject><subject>Survival Analysis</subject><issn>0098-7484</issn><issn>1538-3598</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpdkc1v1DAQxS0EokvhjMQBWeLCJVs7tmP7uFQUkBYV8SVxsibxZOtVEm_jZBEX_nYctvTAXDwa_d6zPY-Q55ytOWP8Yg89rEvG5ZqXlbYPyIorYQqhrHlIVoxZU2hp5Bl5ktKe5eJCPyZnpSorI4Vdkd9f5vEYjtBRGDzdxmFXTDj29Hqemthjolex6-LPMOzomxAPY0zTDU6hocdEP2JzA0NosngTx2X4Hboj0s946KDBHoeJhoF-ginkNtHNDj1VjE6RVpb-QBjTU_KohS7hs7vznHy7evv18n2xvX734XKzLUBaPRVe1cZ79NYwVVc1a23r0aBhdaUVCMPAeNEaU4IEL2Wj8xJaUMYKyHOU4py8PvnmH9zOmCbXh9Rg18GAcU6Oq0ozxYXRGX31H7qP8zjk1zle8VJwqznP1MWJavJK0oitO4yhh_GX48wt0bglGrdE4_5GkxUv73znukd_z__LIgMvTsAivHeznPF86x_JQpLL</recordid><startdate>20141001</startdate><enddate>20141001</enddate><creator>Chiang, Yuting P</creator><creator>Chikwe, Joanna</creator><creator>Moskowitz, Alan J</creator><creator>Itagaki, Shinobu</creator><creator>Adams, David H</creator><creator>Egorova, Natalia N</creator><general>American Medical Association</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QL</scope><scope>7QP</scope><scope>7TK</scope><scope>7TS</scope><scope>7U7</scope><scope>7U9</scope><scope>8FD</scope><scope>C1K</scope><scope>FR3</scope><scope>H94</scope><scope>K9.</scope><scope>M7N</scope><scope>NAPCQ</scope><scope>P64</scope><scope>RC3</scope><scope>7X8</scope></search><sort><creationdate>20141001</creationdate><title>Survival and Long-term Outcomes Following Bioprosthetic vs Mechanical Aortic Valve Replacement in Patients Aged 50 to 69 Years</title><author>Chiang, Yuting P ; Chikwe, Joanna ; Moskowitz, Alan J ; Itagaki, Shinobu ; Adams, David H ; Egorova, Natalia N</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a497t-d5b8dded9805b6b0f9fde8e80b675a380a8d3f882a4ad44c7538fa5893ad3fe43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Aged</topic><topic>Aortic Valve - surgery</topic><topic>Bioprosthesis - adverse effects</topic><topic>Female</topic><topic>Follow-Up Studies</topic><topic>Heart surgery</topic><topic>Heart Valve Prosthesis - adverse effects</topic><topic>Heart Valve Prosthesis Implantation - mortality</topic><topic>Hemorrhage - epidemiology</topic><topic>Hemorrhage - etiology</topic><topic>Humans</topic><topic>Incidence</topic><topic>Male</topic><topic>Medical research</topic><topic>Middle Aged</topic><topic>Older people</topic><topic>Patient safety</topic><topic>Propensity Score</topic><topic>Prosthesis Design</topic><topic>Reoperation - mortality</topic><topic>Retrospective Studies</topic><topic>Stroke - epidemiology</topic><topic>Stroke - etiology</topic><topic>Surgical outcomes</topic><topic>Survival Analysis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chiang, Yuting P</creatorcontrib><creatorcontrib>Chikwe, Joanna</creatorcontrib><creatorcontrib>Moskowitz, Alan J</creatorcontrib><creatorcontrib>Itagaki, Shinobu</creatorcontrib><creatorcontrib>Adams, David H</creatorcontrib><creatorcontrib>Egorova, Natalia N</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Bacteriology Abstracts (Microbiology B)</collection><collection>Calcium & Calcified Tissue Abstracts</collection><collection>Neurosciences Abstracts</collection><collection>Physical Education Index</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Engineering Research Database</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Algology Mycology and Protozoology Abstracts (Microbiology C)</collection><collection>Nursing & Allied Health Premium</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Genetics Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>JAMA : the journal of the American Medical Association</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chiang, Yuting P</au><au>Chikwe, Joanna</au><au>Moskowitz, Alan J</au><au>Itagaki, Shinobu</au><au>Adams, David H</au><au>Egorova, Natalia N</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Survival and Long-term Outcomes Following Bioprosthetic vs Mechanical Aortic Valve Replacement in Patients Aged 50 to 69 Years</atitle><jtitle>JAMA : the journal of the American Medical Association</jtitle><addtitle>JAMA</addtitle><date>2014-10-01</date><risdate>2014</risdate><volume>312</volume><issue>13</issue><spage>1323</spage><epage>1329</epage><pages>1323-1329</pages><issn>0098-7484</issn><eissn>1538-3598</eissn><coden>JAMAAP</coden><abstract>IMPORTANCE: The choice between bioprosthetic and mechanical aortic valve replacement in younger patients is controversial because long-term survival and major morbidity are poorly characterized. OBJECTIVE: To quantify survival and major morbidity in patients aged 50 to 69 years undergoing aortic valve replacement. DESIGN, SETTING, AND PARTICIPANTS: Retrospective cohort analysis of 4253 patients aged 50 to 69 years who underwent primary isolated aortic valve replacement using bioprosthetic vs mechanical valves in New York State from 1997 through 2004, identified using the Statewide Planning and Research Cooperative System. Median follow-up time was 10.8 years (range, 0 to 16.9 years); the last follow-up date for mortality was November 30, 2013. Propensity matching yielded 1001 patient pairs. MAIN OUTCOMES AND MEASURES: Primary outcome was all-cause mortality; secondary outcomes were stroke, reoperation, and major bleeding. RESULTS: No differences in survival or stroke rates were observed in patients with bioprosthetic compared with mechanical valves. Actuarial 15-year survival was 60.6% (95% CI, 56.3%-64.9%) in the bioprosthesis group compared with 62.1% (95% CI, 58.2%-66.0%) in the mechanical prosthesis group (hazard ratio, 0.97 [95% CI, 0.83-1.14]). The 15-year cumulative incidence of stroke was 7.7% (95% CI, 5.7%-9.7%) in the bioprosthesis group and 8.6% (95% CI, 6.2%-11.0%) in the mechanical prosthesis group (hazard ratio, 1.04 [95% CI, 0.75-1.43). The 15-year cumulative incidence of reoperation was higher in the bioprosthesis group (12.1% [95% CI, 8.8%-15.4%] vs 6.9% [95% CI, 4.2%-9.6%]; hazard ratio, 0.52 [95% CI, 0.36-0.75]). The 15-year cumulative incidence of major bleeding was higher in the mechanical prosthesis group (13.0% [95% CI, 9.9%-16.1%] vs 6.6% [95% CI, 4.8%-8.4%]; hazard ratio, 1.75 [95% CI, 1.27-2.43]). The 30-day mortality rate was 18.7% after stroke, 9.0% after reoperation, and 13.2% after major bleeding. CONCLUSIONS AND RELEVANCE: Among propensity-matched patients aged 50 to 69 years who underwent aortic valve replacement with bioprosthetic compared with mechanical valves, there was no significant difference in 15-year survival or stroke. Patients in the bioprosthetic valve group had a greater likelihood of reoperation but a lower likelihood of major bleeding. These findings suggest that bioprosthetic valves may be a reasonable choice in patients aged 50 to 69 years.</abstract><cop>United States</cop><pub>American Medical Association</pub><pmid>25268439</pmid><doi>10.1001/jama.2014.12679</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0098-7484 |
ispartof | JAMA : the journal of the American Medical Association, 2014-10, Vol.312 (13), p.1323-1329 |
issn | 0098-7484 1538-3598 |
language | eng |
recordid | cdi_proquest_miscellaneous_1567051387 |
source | MEDLINE; American Medical Association Journals |
subjects | Aged Aortic Valve - surgery Bioprosthesis - adverse effects Female Follow-Up Studies Heart surgery Heart Valve Prosthesis - adverse effects Heart Valve Prosthesis Implantation - mortality Hemorrhage - epidemiology Hemorrhage - etiology Humans Incidence Male Medical research Middle Aged Older people Patient safety Propensity Score Prosthesis Design Reoperation - mortality Retrospective Studies Stroke - epidemiology Stroke - etiology Surgical outcomes Survival Analysis |
title | Survival and Long-term Outcomes Following Bioprosthetic vs Mechanical Aortic Valve Replacement in Patients Aged 50 to 69 Years |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T13%3A11%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Survival%20and%20Long-term%20Outcomes%20Following%20Bioprosthetic%20vs%20Mechanical%20Aortic%20Valve%20Replacement%20in%20Patients%20Aged%2050%20to%2069%20Years&rft.jtitle=JAMA%20:%20the%20journal%20of%20the%20American%20Medical%20Association&rft.au=Chiang,%20Yuting%20P&rft.date=2014-10-01&rft.volume=312&rft.issue=13&rft.spage=1323&rft.epage=1329&rft.pages=1323-1329&rft.issn=0098-7484&rft.eissn=1538-3598&rft.coden=JAMAAP&rft_id=info:doi/10.1001/jama.2014.12679&rft_dat=%3Cproquest_cross%3E3462329161%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1612319711&rft_id=info:pmid/25268439&rft_ama_id=1910112&rfr_iscdi=true |