Deliverability of the Resolute Integrity stent and a post hoc comparison of radial and femoral access: The DELIVER study

Abstract Background/Purpose DELIVER (DELiverability of the Resolute Integrity Stent in All-Comer Vessels and Cross-OvER stenting) was a prospective, multicenter, all-comers registry to assess the deliverability of the Resolute Integrity™ zotarolimus-eluting stent (R-ZES). Methods/Materials Patients...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Cardiovascular revascularization medicine 2014-07, Vol.15 (5), p.289-294
Hauptverfasser: Polad, Jawed, Wöhrle, Jochen, Singh, Balbir, Chag, Milan, Rha, Seung-Woon, Malik, Fazila-Tun-Nesa, van Eck, Martijn, Rottbauer, Wolfgang
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Background/Purpose DELIVER (DELiverability of the Resolute Integrity Stent in All-Comer Vessels and Cross-OvER stenting) was a prospective, multicenter, all-comers registry to assess the deliverability of the Resolute Integrity™ zotarolimus-eluting stent (R-ZES). Methods/Materials Patients (n = 7740 patients, 10449 lesions) undergoing percutaneous coronary intervention and deemed suitable for R-ZES implantation were enrolled and treated according to standard practice of the participating centers in 30 countries. Outcomes included delivery success and in-hospital target lesion failure (TLF), major adverse cardiac event (MACE), and Academic Research Consortium definite/probable stent thrombosis. We performed a post hoc analysis comparing deliverability, in-hospital clinical outcomes and resource utilization with radial vs. femoral access. Results A high proportion of the population had complex disease (71%): mean lesion length was 26.7 ± 17.5 mm, 35% of lesions were moderately/severely calcified and 17% were bifurcated. Femoral and radial accesses were used in 53% and 46% of patients, respectively. Patients treated using femoral access had more complex coronary artery disease. Primary delivery success was 98.9% and did not differ by approach. Radial access was associated with lower stent and balloon utilization, but higher guide catheter utilization, lower procedure duration, and contrast administered compared with femoral access. In-hospital TLF and MACE occurred in 1.6% of patients; definite or probable stent thrombosis occurred in 0.2%. Clinical outcomes did not differ by vascular access. Conclusions R-ZES was found to be highly deliverable in a complex, all-comers, international population, regardless of whether radial or femoral access was used. In-hospital outcomes were excellent with very low risk of complications.
ISSN:1553-8389
1878-0938
DOI:10.1016/j.carrev.2014.07.002