Optimizing scan protocol in whole-brain vessel one-stop examination with 640-multislice computed tomography
To explore the feasibility of optimized scan protocol in whole-brain vessel one-stop examination with 640-multislice computed tomography (640-MSCT) scanner. A total of 28 patients undergoing whole-brain vessel examination but showing no obvious cerebral disease with 640-MSCT scanner between Septembe...
Gespeichert in:
Veröffentlicht in: | Zhong hua yi xue za zhi 2014-06, Vol.94 (21), p.1609-1612 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | chi |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1612 |
---|---|
container_issue | 21 |
container_start_page | 1609 |
container_title | Zhong hua yi xue za zhi |
container_volume | 94 |
creator | Cao, Guoquan Zhou, Xiaojun Xu, Huazhi Pan, Kehua Chen, Weijian Li, Rui |
description | To explore the feasibility of optimized scan protocol in whole-brain vessel one-stop examination with 640-multislice computed tomography (640-MSCT) scanner.
A total of 28 patients undergoing whole-brain vessel examination but showing no obvious cerebral disease with 640-MSCT scanner between September 2012 and May 2013 were collected and divided into two groups of A (n = 14) and B (n = 14) . The recommended scan protocol (protocol 1: collecting 19 volumes) was applied in A group while the optimized scan protocol (protocol 2: collecting 15 volumes) formulated by reducing scanning phases reasonably and changing collection intervals in B group. The dose length product (DLP) was recorded automatically and effective dose (E) measured. The CT perfusion (CTP) values and computed tomographic angiography (CTA) images were analyzed for both groups. The regions of interest (ROI) of CTP images with area (20 ± 2) mm² were located in bilateral frontal white matter, parietal white matter, centrum semiovate, basal ganglia, oc |
doi_str_mv | 10.3760/cma.j.issn.0376-2491.2014.21.003 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_1556290377</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1556290377</sourcerecordid><originalsourceid>FETCH-LOGICAL-p196t-771c2d11b14741260813bc9bcd4e47661b66d753527e50213ae39f5c83b5e73d3</originalsourceid><addsrcrecordid>eNo9kD1PwzAYhD2AaAX9C8hjlwR_uxlRxZdUqQvMke28bQ1xHGIHKL-eSBSmO50enXSH0JKSkmtFblww5WvpU-pKMgUFExUtGaGiZLQkhJ-h-X8-Q4uUvCVC84oRRi_QjEkqGVuROXrb9tkH_-27PU7OdLgfYo4utth3-PMQWyjsYCb_ASlBi2MHRcqxx_Blgu9M9nHifD5gJUgRxjb71HoH2MXQjxkanGOI-8H0h-MVOt-ZNsHipJfo5f7uef1YbLYPT-vbTdHTSuVCa-pYQ6mlQgvKFFlRbl1lXSNAaKWoVarRkkumQU57uAFe7aRbcStB84ZfouVv77TlfYSU6-CTg7Y1HcQx1VRKxarpHz2h1yd0tAGauh98MMOx_juI_wBtNGwl</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1556290377</pqid></control><display><type>article</type><title>Optimizing scan protocol in whole-brain vessel one-stop examination with 640-multislice computed tomography</title><source>MEDLINE</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Cao, Guoquan ; Zhou, Xiaojun ; Xu, Huazhi ; Pan, Kehua ; Chen, Weijian ; Li, Rui</creator><creatorcontrib>Cao, Guoquan ; Zhou, Xiaojun ; Xu, Huazhi ; Pan, Kehua ; Chen, Weijian ; Li, Rui</creatorcontrib><description>To explore the feasibility of optimized scan protocol in whole-brain vessel one-stop examination with 640-multislice computed tomography (640-MSCT) scanner.
A total of 28 patients undergoing whole-brain vessel examination but showing no obvious cerebral disease with 640-MSCT scanner between September 2012 and May 2013 were collected and divided into two groups of A (n = 14) and B (n = 14) . The recommended scan protocol (protocol 1: collecting 19 volumes) was applied in A group while the optimized scan protocol (protocol 2: collecting 15 volumes) formulated by reducing scanning phases reasonably and changing collection intervals in B group. The dose length product (DLP) was recorded automatically and effective dose (E) measured. The CT perfusion (CTP) values and computed tomographic angiography (CTA) images were analyzed for both groups. The regions of interest (ROI) of CTP images with area (20 ± 2) mm² were located in bilateral frontal white matter, parietal white matter, centrum semiovate, basal ganglia, oc</description><identifier>ISSN: 0376-2491</identifier><identifier>DOI: 10.3760/cma.j.issn.0376-2491.2014.21.003</identifier><identifier>PMID: 25152280</identifier><language>chi</language><publisher>China</publisher><subject>Angiography ; Brain - blood supply ; Brain - diagnostic imaging ; Double-Blind Method ; Humans ; Multidetector Computed Tomography - methods ; Radiation Dosage</subject><ispartof>Zhong hua yi xue za zhi, 2014-06, Vol.94 (21), p.1609-1612</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25152280$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Cao, Guoquan</creatorcontrib><creatorcontrib>Zhou, Xiaojun</creatorcontrib><creatorcontrib>Xu, Huazhi</creatorcontrib><creatorcontrib>Pan, Kehua</creatorcontrib><creatorcontrib>Chen, Weijian</creatorcontrib><creatorcontrib>Li, Rui</creatorcontrib><title>Optimizing scan protocol in whole-brain vessel one-stop examination with 640-multislice computed tomography</title><title>Zhong hua yi xue za zhi</title><addtitle>Zhonghua Yi Xue Za Zhi</addtitle><description>To explore the feasibility of optimized scan protocol in whole-brain vessel one-stop examination with 640-multislice computed tomography (640-MSCT) scanner.
A total of 28 patients undergoing whole-brain vessel examination but showing no obvious cerebral disease with 640-MSCT scanner between September 2012 and May 2013 were collected and divided into two groups of A (n = 14) and B (n = 14) . The recommended scan protocol (protocol 1: collecting 19 volumes) was applied in A group while the optimized scan protocol (protocol 2: collecting 15 volumes) formulated by reducing scanning phases reasonably and changing collection intervals in B group. The dose length product (DLP) was recorded automatically and effective dose (E) measured. The CT perfusion (CTP) values and computed tomographic angiography (CTA) images were analyzed for both groups. The regions of interest (ROI) of CTP images with area (20 ± 2) mm² were located in bilateral frontal white matter, parietal white matter, centrum semiovate, basal ganglia, oc</description><subject>Angiography</subject><subject>Brain - blood supply</subject><subject>Brain - diagnostic imaging</subject><subject>Double-Blind Method</subject><subject>Humans</subject><subject>Multidetector Computed Tomography - methods</subject><subject>Radiation Dosage</subject><issn>0376-2491</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kD1PwzAYhD2AaAX9C8hjlwR_uxlRxZdUqQvMke28bQ1xHGIHKL-eSBSmO50enXSH0JKSkmtFblww5WvpU-pKMgUFExUtGaGiZLQkhJ-h-X8-Q4uUvCVC84oRRi_QjEkqGVuROXrb9tkH_-27PU7OdLgfYo4utth3-PMQWyjsYCb_ASlBi2MHRcqxx_Blgu9M9nHifD5gJUgRxjb71HoH2MXQjxkanGOI-8H0h-MVOt-ZNsHipJfo5f7uef1YbLYPT-vbTdHTSuVCa-pYQ6mlQgvKFFlRbl1lXSNAaKWoVarRkkumQU57uAFe7aRbcStB84ZfouVv77TlfYSU6-CTg7Y1HcQx1VRKxarpHz2h1yd0tAGauh98MMOx_juI_wBtNGwl</recordid><startdate>20140603</startdate><enddate>20140603</enddate><creator>Cao, Guoquan</creator><creator>Zhou, Xiaojun</creator><creator>Xu, Huazhi</creator><creator>Pan, Kehua</creator><creator>Chen, Weijian</creator><creator>Li, Rui</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>20140603</creationdate><title>Optimizing scan protocol in whole-brain vessel one-stop examination with 640-multislice computed tomography</title><author>Cao, Guoquan ; Zhou, Xiaojun ; Xu, Huazhi ; Pan, Kehua ; Chen, Weijian ; Li, Rui</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p196t-771c2d11b14741260813bc9bcd4e47661b66d753527e50213ae39f5c83b5e73d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>chi</language><creationdate>2014</creationdate><topic>Angiography</topic><topic>Brain - blood supply</topic><topic>Brain - diagnostic imaging</topic><topic>Double-Blind Method</topic><topic>Humans</topic><topic>Multidetector Computed Tomography - methods</topic><topic>Radiation Dosage</topic><toplevel>online_resources</toplevel><creatorcontrib>Cao, Guoquan</creatorcontrib><creatorcontrib>Zhou, Xiaojun</creatorcontrib><creatorcontrib>Xu, Huazhi</creatorcontrib><creatorcontrib>Pan, Kehua</creatorcontrib><creatorcontrib>Chen, Weijian</creatorcontrib><creatorcontrib>Li, Rui</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Zhong hua yi xue za zhi</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cao, Guoquan</au><au>Zhou, Xiaojun</au><au>Xu, Huazhi</au><au>Pan, Kehua</au><au>Chen, Weijian</au><au>Li, Rui</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Optimizing scan protocol in whole-brain vessel one-stop examination with 640-multislice computed tomography</atitle><jtitle>Zhong hua yi xue za zhi</jtitle><addtitle>Zhonghua Yi Xue Za Zhi</addtitle><date>2014-06-03</date><risdate>2014</risdate><volume>94</volume><issue>21</issue><spage>1609</spage><epage>1612</epage><pages>1609-1612</pages><issn>0376-2491</issn><abstract>To explore the feasibility of optimized scan protocol in whole-brain vessel one-stop examination with 640-multislice computed tomography (640-MSCT) scanner.
A total of 28 patients undergoing whole-brain vessel examination but showing no obvious cerebral disease with 640-MSCT scanner between September 2012 and May 2013 were collected and divided into two groups of A (n = 14) and B (n = 14) . The recommended scan protocol (protocol 1: collecting 19 volumes) was applied in A group while the optimized scan protocol (protocol 2: collecting 15 volumes) formulated by reducing scanning phases reasonably and changing collection intervals in B group. The dose length product (DLP) was recorded automatically and effective dose (E) measured. The CT perfusion (CTP) values and computed tomographic angiography (CTA) images were analyzed for both groups. The regions of interest (ROI) of CTP images with area (20 ± 2) mm² were located in bilateral frontal white matter, parietal white matter, centrum semiovate, basal ganglia, oc</abstract><cop>China</cop><pmid>25152280</pmid><doi>10.3760/cma.j.issn.0376-2491.2014.21.003</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0376-2491 |
ispartof | Zhong hua yi xue za zhi, 2014-06, Vol.94 (21), p.1609-1612 |
issn | 0376-2491 |
language | chi |
recordid | cdi_proquest_miscellaneous_1556290377 |
source | MEDLINE; EZB-FREE-00999 freely available EZB journals |
subjects | Angiography Brain - blood supply Brain - diagnostic imaging Double-Blind Method Humans Multidetector Computed Tomography - methods Radiation Dosage |
title | Optimizing scan protocol in whole-brain vessel one-stop examination with 640-multislice computed tomography |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T12%3A15%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Optimizing%20scan%20protocol%20in%20whole-brain%20vessel%20one-stop%20examination%20with%20640-multislice%20computed%20tomography&rft.jtitle=Zhong%20hua%20yi%20xue%20za%20zhi&rft.au=Cao,%20Guoquan&rft.date=2014-06-03&rft.volume=94&rft.issue=21&rft.spage=1609&rft.epage=1612&rft.pages=1609-1612&rft.issn=0376-2491&rft_id=info:doi/10.3760/cma.j.issn.0376-2491.2014.21.003&rft_dat=%3Cproquest_pubme%3E1556290377%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1556290377&rft_id=info:pmid/25152280&rfr_iscdi=true |