Noncontact Proximity Vital Sign Sensor Based on PLL for Sensitivity Enhancement

In this paper, a noncontact proximity vital sign sensor, using a phase locked loop (PLL) incorporated with voltage controlled oscillator (VCO) built-in planar type circular resonator, is proposed to enhance sensitivity in severe environments. The planar type circular resonator acts as a series feedb...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on biomedical circuits and systems 2014-08, Vol.8 (4), p.584-593
Hauptverfasser: Hong, Yunseog, Kim, Sang-Gyu, Kim, Byung-Hyun, Ha, Sung-Jae, Lee, Hee-Jo, Yun, Gi-Ho, Yook, Jong-Gwan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 593
container_issue 4
container_start_page 584
container_title IEEE transactions on biomedical circuits and systems
container_volume 8
creator Hong, Yunseog
Kim, Sang-Gyu
Kim, Byung-Hyun
Ha, Sung-Jae
Lee, Hee-Jo
Yun, Gi-Ho
Yook, Jong-Gwan
description In this paper, a noncontact proximity vital sign sensor, using a phase locked loop (PLL) incorporated with voltage controlled oscillator (VCO) built-in planar type circular resonator, is proposed to enhance sensitivity in severe environments. The planar type circular resonator acts as a series feedback element of the VCO as well as a near-field receiving antenna. The frequency deviation of the VCO related to the body proximity effect ranges from 0.07 MHz/mm to 1.8 MHz/mm (6.8 mV/mm to 205 mV/mm in sensitivity) up to a distance of 50 mm, while the amount of VCO drift is about 21 MHz in the condition of 60 ° C temperature range and discrete component tolerance of ±5%. Total frequency variation occurs in the capture range of the PLL which is 60 MHz. Thus, its loop control voltage converts the amount of frequency deviation into a difference of direct current (DC) voltage, which is utilized to extract vital signs regardless of the ambient temperature. The experimental results reveal that the proposed sensor placed 50 mm away from a subject can reliably detect respiration and heartbeat signals without the ambiguity of harmonic signals caused by respiration signal at an operating frequency of 2.4 GHz.
doi_str_mv 10.1109/TBCAS.2013.2280913
format Article
fullrecord <record><control><sourceid>proquest_RIE</sourceid><recordid>TN_cdi_proquest_miscellaneous_1555017784</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>6654290</ieee_id><sourcerecordid>1550077872</sourcerecordid><originalsourceid>FETCH-LOGICAL-c454t-4b73151ebf8f3534235e91d464e83366d6eede4f86db5fd906f79c160f1a1d263</originalsourceid><addsrcrecordid>eNqNkctOwzAQRS0E4v0DIKFIbNikePxKvKQVL6miSAW2UZqMwaixIU4R_XscWliwYmVrfGZ0x4eQI6ADAKrPH4aji-mAUeADxnKqgW-QXdCCplprutnfOUuFFHKH7IXwSqlUTLNtssME45ID7JLJnXeVd11Zdcl96z9tY7tl8mS7cp5M7bNLpuiCb5NhGbBOvEvux-PExEJft5396PFL91K6Cht03QHZMuU84OH63CePV5cPo5t0PLm-HV2M0yrm6VIxyzhIwJnJTUzSx0ENtVACc86VqhVijcLkqp5JU2uqTKYrUNRACTVTfJ-crea-tf59gaErGhsqnM9Lh34RCpBSUsiyXPwHpTSSGYvo6R_01S9aFxeJlNBA48flkWIrqmp9CC2a4q21TdkuC6BFb6b4NlP0Zoq1mdh0sh69mDVY_7b8qIjA8QqwiPj7rJQUTFP-BQYGj_8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1549102428</pqid></control><display><type>article</type><title>Noncontact Proximity Vital Sign Sensor Based on PLL for Sensitivity Enhancement</title><source>IEEE Electronic Library (IEL)</source><creator>Hong, Yunseog ; Kim, Sang-Gyu ; Kim, Byung-Hyun ; Ha, Sung-Jae ; Lee, Hee-Jo ; Yun, Gi-Ho ; Yook, Jong-Gwan</creator><creatorcontrib>Hong, Yunseog ; Kim, Sang-Gyu ; Kim, Byung-Hyun ; Ha, Sung-Jae ; Lee, Hee-Jo ; Yun, Gi-Ho ; Yook, Jong-Gwan</creatorcontrib><description>In this paper, a noncontact proximity vital sign sensor, using a phase locked loop (PLL) incorporated with voltage controlled oscillator (VCO) built-in planar type circular resonator, is proposed to enhance sensitivity in severe environments. The planar type circular resonator acts as a series feedback element of the VCO as well as a near-field receiving antenna. The frequency deviation of the VCO related to the body proximity effect ranges from 0.07 MHz/mm to 1.8 MHz/mm (6.8 mV/mm to 205 mV/mm in sensitivity) up to a distance of 50 mm, while the amount of VCO drift is about 21 MHz in the condition of 60 ° C temperature range and discrete component tolerance of ±5%. Total frequency variation occurs in the capture range of the PLL which is 60 MHz. Thus, its loop control voltage converts the amount of frequency deviation into a difference of direct current (DC) voltage, which is utilized to extract vital signs regardless of the ambient temperature. The experimental results reveal that the proposed sensor placed 50 mm away from a subject can reliably detect respiration and heartbeat signals without the ambiguity of harmonic signals caused by respiration signal at an operating frequency of 2.4 GHz.</description><identifier>ISSN: 1932-4545</identifier><identifier>EISSN: 1940-9990</identifier><identifier>DOI: 10.1109/TBCAS.2013.2280913</identifier><identifier>PMID: 24235311</identifier><identifier>CODEN: ITBCCW</identifier><language>eng</language><publisher>United States: IEEE</publisher><subject>Biomedicine ; Breath Tests - instrumentation ; Equipment Design ; feedback circuit ; Heart Rate - physiology ; Humans ; Impedance ; input impedance variation ; near-field receiving antenna ; noncontact ; phase locked loop (PLL) ; Phase locked loops ; remote sensing ; Resonant frequency ; Sensitivity ; Signal Processing, Computer-Assisted ; Temperature sensors ; vital sign sensor ; Voltage-controlled oscillators</subject><ispartof>IEEE transactions on biomedical circuits and systems, 2014-08, Vol.8 (4), p.584-593</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) Aug 2014</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c454t-4b73151ebf8f3534235e91d464e83366d6eede4f86db5fd906f79c160f1a1d263</citedby><cites>FETCH-LOGICAL-c454t-4b73151ebf8f3534235e91d464e83366d6eede4f86db5fd906f79c160f1a1d263</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/6654290$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,776,780,792,27901,27902,54733</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/6654290$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24235311$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hong, Yunseog</creatorcontrib><creatorcontrib>Kim, Sang-Gyu</creatorcontrib><creatorcontrib>Kim, Byung-Hyun</creatorcontrib><creatorcontrib>Ha, Sung-Jae</creatorcontrib><creatorcontrib>Lee, Hee-Jo</creatorcontrib><creatorcontrib>Yun, Gi-Ho</creatorcontrib><creatorcontrib>Yook, Jong-Gwan</creatorcontrib><title>Noncontact Proximity Vital Sign Sensor Based on PLL for Sensitivity Enhancement</title><title>IEEE transactions on biomedical circuits and systems</title><addtitle>TBCAS</addtitle><addtitle>IEEE Trans Biomed Circuits Syst</addtitle><description>In this paper, a noncontact proximity vital sign sensor, using a phase locked loop (PLL) incorporated with voltage controlled oscillator (VCO) built-in planar type circular resonator, is proposed to enhance sensitivity in severe environments. The planar type circular resonator acts as a series feedback element of the VCO as well as a near-field receiving antenna. The frequency deviation of the VCO related to the body proximity effect ranges from 0.07 MHz/mm to 1.8 MHz/mm (6.8 mV/mm to 205 mV/mm in sensitivity) up to a distance of 50 mm, while the amount of VCO drift is about 21 MHz in the condition of 60 ° C temperature range and discrete component tolerance of ±5%. Total frequency variation occurs in the capture range of the PLL which is 60 MHz. Thus, its loop control voltage converts the amount of frequency deviation into a difference of direct current (DC) voltage, which is utilized to extract vital signs regardless of the ambient temperature. The experimental results reveal that the proposed sensor placed 50 mm away from a subject can reliably detect respiration and heartbeat signals without the ambiguity of harmonic signals caused by respiration signal at an operating frequency of 2.4 GHz.</description><subject>Biomedicine</subject><subject>Breath Tests - instrumentation</subject><subject>Equipment Design</subject><subject>feedback circuit</subject><subject>Heart Rate - physiology</subject><subject>Humans</subject><subject>Impedance</subject><subject>input impedance variation</subject><subject>near-field receiving antenna</subject><subject>noncontact</subject><subject>phase locked loop (PLL)</subject><subject>Phase locked loops</subject><subject>remote sensing</subject><subject>Resonant frequency</subject><subject>Sensitivity</subject><subject>Signal Processing, Computer-Assisted</subject><subject>Temperature sensors</subject><subject>vital sign sensor</subject><subject>Voltage-controlled oscillators</subject><issn>1932-4545</issn><issn>1940-9990</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>RIE</sourceid><sourceid>EIF</sourceid><recordid>eNqNkctOwzAQRS0E4v0DIKFIbNikePxKvKQVL6miSAW2UZqMwaixIU4R_XscWliwYmVrfGZ0x4eQI6ADAKrPH4aji-mAUeADxnKqgW-QXdCCplprutnfOUuFFHKH7IXwSqlUTLNtssME45ID7JLJnXeVd11Zdcl96z9tY7tl8mS7cp5M7bNLpuiCb5NhGbBOvEvux-PExEJft5396PFL91K6Cht03QHZMuU84OH63CePV5cPo5t0PLm-HV2M0yrm6VIxyzhIwJnJTUzSx0ENtVACc86VqhVijcLkqp5JU2uqTKYrUNRACTVTfJ-crea-tf59gaErGhsqnM9Lh34RCpBSUsiyXPwHpTSSGYvo6R_01S9aFxeJlNBA48flkWIrqmp9CC2a4q21TdkuC6BFb6b4NlP0Zoq1mdh0sh69mDVY_7b8qIjA8QqwiPj7rJQUTFP-BQYGj_8</recordid><startdate>20140801</startdate><enddate>20140801</enddate><creator>Hong, Yunseog</creator><creator>Kim, Sang-Gyu</creator><creator>Kim, Byung-Hyun</creator><creator>Ha, Sung-Jae</creator><creator>Lee, Hee-Jo</creator><creator>Yun, Gi-Ho</creator><creator>Yook, Jong-Gwan</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>7SP</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>L7M</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>20140801</creationdate><title>Noncontact Proximity Vital Sign Sensor Based on PLL for Sensitivity Enhancement</title><author>Hong, Yunseog ; Kim, Sang-Gyu ; Kim, Byung-Hyun ; Ha, Sung-Jae ; Lee, Hee-Jo ; Yun, Gi-Ho ; Yook, Jong-Gwan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c454t-4b73151ebf8f3534235e91d464e83366d6eede4f86db5fd906f79c160f1a1d263</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Biomedicine</topic><topic>Breath Tests - instrumentation</topic><topic>Equipment Design</topic><topic>feedback circuit</topic><topic>Heart Rate - physiology</topic><topic>Humans</topic><topic>Impedance</topic><topic>input impedance variation</topic><topic>near-field receiving antenna</topic><topic>noncontact</topic><topic>phase locked loop (PLL)</topic><topic>Phase locked loops</topic><topic>remote sensing</topic><topic>Resonant frequency</topic><topic>Sensitivity</topic><topic>Signal Processing, Computer-Assisted</topic><topic>Temperature sensors</topic><topic>vital sign sensor</topic><topic>Voltage-controlled oscillators</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hong, Yunseog</creatorcontrib><creatorcontrib>Kim, Sang-Gyu</creatorcontrib><creatorcontrib>Kim, Byung-Hyun</creatorcontrib><creatorcontrib>Ha, Sung-Jae</creatorcontrib><creatorcontrib>Lee, Hee-Jo</creatorcontrib><creatorcontrib>Yun, Gi-Ho</creatorcontrib><creatorcontrib>Yook, Jong-Gwan</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>IEEE transactions on biomedical circuits and systems</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Hong, Yunseog</au><au>Kim, Sang-Gyu</au><au>Kim, Byung-Hyun</au><au>Ha, Sung-Jae</au><au>Lee, Hee-Jo</au><au>Yun, Gi-Ho</au><au>Yook, Jong-Gwan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Noncontact Proximity Vital Sign Sensor Based on PLL for Sensitivity Enhancement</atitle><jtitle>IEEE transactions on biomedical circuits and systems</jtitle><stitle>TBCAS</stitle><addtitle>IEEE Trans Biomed Circuits Syst</addtitle><date>2014-08-01</date><risdate>2014</risdate><volume>8</volume><issue>4</issue><spage>584</spage><epage>593</epage><pages>584-593</pages><issn>1932-4545</issn><eissn>1940-9990</eissn><coden>ITBCCW</coden><abstract>In this paper, a noncontact proximity vital sign sensor, using a phase locked loop (PLL) incorporated with voltage controlled oscillator (VCO) built-in planar type circular resonator, is proposed to enhance sensitivity in severe environments. The planar type circular resonator acts as a series feedback element of the VCO as well as a near-field receiving antenna. The frequency deviation of the VCO related to the body proximity effect ranges from 0.07 MHz/mm to 1.8 MHz/mm (6.8 mV/mm to 205 mV/mm in sensitivity) up to a distance of 50 mm, while the amount of VCO drift is about 21 MHz in the condition of 60 ° C temperature range and discrete component tolerance of ±5%. Total frequency variation occurs in the capture range of the PLL which is 60 MHz. Thus, its loop control voltage converts the amount of frequency deviation into a difference of direct current (DC) voltage, which is utilized to extract vital signs regardless of the ambient temperature. The experimental results reveal that the proposed sensor placed 50 mm away from a subject can reliably detect respiration and heartbeat signals without the ambiguity of harmonic signals caused by respiration signal at an operating frequency of 2.4 GHz.</abstract><cop>United States</cop><pub>IEEE</pub><pmid>24235311</pmid><doi>10.1109/TBCAS.2013.2280913</doi><tpages>10</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1932-4545
ispartof IEEE transactions on biomedical circuits and systems, 2014-08, Vol.8 (4), p.584-593
issn 1932-4545
1940-9990
language eng
recordid cdi_proquest_miscellaneous_1555017784
source IEEE Electronic Library (IEL)
subjects Biomedicine
Breath Tests - instrumentation
Equipment Design
feedback circuit
Heart Rate - physiology
Humans
Impedance
input impedance variation
near-field receiving antenna
noncontact
phase locked loop (PLL)
Phase locked loops
remote sensing
Resonant frequency
Sensitivity
Signal Processing, Computer-Assisted
Temperature sensors
vital sign sensor
Voltage-controlled oscillators
title Noncontact Proximity Vital Sign Sensor Based on PLL for Sensitivity Enhancement
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T00%3A58%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Noncontact%20Proximity%20Vital%20Sign%20Sensor%20Based%20on%20PLL%20for%20Sensitivity%20Enhancement&rft.jtitle=IEEE%20transactions%20on%20biomedical%20circuits%20and%20systems&rft.au=Hong,%20Yunseog&rft.date=2014-08-01&rft.volume=8&rft.issue=4&rft.spage=584&rft.epage=593&rft.pages=584-593&rft.issn=1932-4545&rft.eissn=1940-9990&rft.coden=ITBCCW&rft_id=info:doi/10.1109/TBCAS.2013.2280913&rft_dat=%3Cproquest_RIE%3E1550077872%3C/proquest_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1549102428&rft_id=info:pmid/24235311&rft_ieee_id=6654290&rfr_iscdi=true