An improved LC-MS/MS method for quantitation of indapamide in whole blood: application for a bioequivalence study

ABSTRACT An improved LC‐MS/MS method for the quantitation of indapamide in human whole blood was developed and validated. Indapamide‐d3 was used as internal standard (IS) and liquid–liquid extraction was employed for sample preparation. LC separation was performed on Synergi Polar RP‐column (50 × 4....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biomedical chromatography 2014-09, Vol.28 (9), p.1212-1218
Hauptverfasser: Pinto, Guilherme Araújo, Pastre, Kátia Isabel Fercondini, Bellorio, Karini Bruno, de Souza Teixeira, Leonardo, de Souza, Weidson Carlo, de Abreu, Fernanda Crunivel, de Santana e Silva Cardoso, Fabiana Fernandes, Pianetti, Gerson Antônio, César, Isabela Costa
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1218
container_issue 9
container_start_page 1212
container_title Biomedical chromatography
container_volume 28
creator Pinto, Guilherme Araújo
Pastre, Kátia Isabel Fercondini
Bellorio, Karini Bruno
de Souza Teixeira, Leonardo
de Souza, Weidson Carlo
de Abreu, Fernanda Crunivel
de Santana e Silva Cardoso, Fabiana Fernandes
Pianetti, Gerson Antônio
César, Isabela Costa
description ABSTRACT An improved LC‐MS/MS method for the quantitation of indapamide in human whole blood was developed and validated. Indapamide‐d3 was used as internal standard (IS) and liquid–liquid extraction was employed for sample preparation. LC separation was performed on Synergi Polar RP‐column (50 × 4.6 mm i.d.; 4 µm) and mobile phase composed of methanol and 5 mm aqueous ammonium acetate containing 1 mm formic acid (60:40), at flow rate of 1 mL/min. The run time was 3.0 min and the injection volume was 20 μL. Mass spectrometric detection was performed using electrospray ion source in negative ionization mode, using the transitions m/z 364.0 → m/z 188.9 and m/z 367.0 → m/z 188.9 for indapamide and IS, respectively. Calibration curve was constructed over the range 0.25–50 ng/mL. The method was precise and accurate, and provided recovery rates >80% for indapamide and IS. The method was applied to determine blood concentrations of indapamide in a bioequivalence study with two sustained release tablet formulations. The 90% confidence interval for the geometric mean ratios for maximum concentration was 95.78% and for the area under the concentration–time curve it was 97.91%. The tested indapamide tablets (Eurofarma Laboratórios S.A.) were bioequivalent to Natrilix®, according to the rate and extent of absorption. Copyright © 2014 John Wiley & Sons, Ltd.
doi_str_mv 10.1002/bmc.3148
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1552368707</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1552368707</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4298-25f2fc1db418277c8108b6496fa3c034fce433d6ab4f6caf36598a97488e16cc3</originalsourceid><addsrcrecordid>eNp1kMtO3DAUQK2qVZnSSnxB5WU3Ab_iBzsatRRpBlpBy9Jy_BAuSZyJE2D-noxmSles7l2ce6R7ADjC6BgjRE7q1h5TzOQbsMBIqQJJhN-CBSJcFVQKdQA-5PwXIaQ4Ee_BAWGiJFLhBVifdTC2_ZAevIPLqlhdn6yuYevHu-RgSANcT6Yb42jGmDqYAoydM71po_PzCh_vUuNh3aTkTqHp-ybaHbk9NbCOya-n-GAa31kP8zi5zUfwLpgm-0_7eQh-f_92U_0ollfnF9XZsrCMKFmQMpBgsasZlkQIKzGSNWeKB0MtoixYzyh13NQscGsC5aWSRgkmpcfcWnoIvuy883PryedRtzFb3zSm82nKGpcloVwKJP6jdkg5Dz7ofoitGTYaI70NrOfAeht4Rj_vrVPdevcC_is6A8UOeIyN37wq0l9X1V6452Me_dMLb4Z7zQUVpb69PNdqefPzzy9eaU6fASajk7k</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1552368707</pqid></control><display><type>article</type><title>An improved LC-MS/MS method for quantitation of indapamide in whole blood: application for a bioequivalence study</title><source>MEDLINE</source><source>Wiley Online Library Journals Frontfile Complete</source><creator>Pinto, Guilherme Araújo ; Pastre, Kátia Isabel Fercondini ; Bellorio, Karini Bruno ; de Souza Teixeira, Leonardo ; de Souza, Weidson Carlo ; de Abreu, Fernanda Crunivel ; de Santana e Silva Cardoso, Fabiana Fernandes ; Pianetti, Gerson Antônio ; César, Isabela Costa</creator><creatorcontrib>Pinto, Guilherme Araújo ; Pastre, Kátia Isabel Fercondini ; Bellorio, Karini Bruno ; de Souza Teixeira, Leonardo ; de Souza, Weidson Carlo ; de Abreu, Fernanda Crunivel ; de Santana e Silva Cardoso, Fabiana Fernandes ; Pianetti, Gerson Antônio ; César, Isabela Costa</creatorcontrib><description>ABSTRACT An improved LC‐MS/MS method for the quantitation of indapamide in human whole blood was developed and validated. Indapamide‐d3 was used as internal standard (IS) and liquid–liquid extraction was employed for sample preparation. LC separation was performed on Synergi Polar RP‐column (50 × 4.6 mm i.d.; 4 µm) and mobile phase composed of methanol and 5 mm aqueous ammonium acetate containing 1 mm formic acid (60:40), at flow rate of 1 mL/min. The run time was 3.0 min and the injection volume was 20 μL. Mass spectrometric detection was performed using electrospray ion source in negative ionization mode, using the transitions m/z 364.0 → m/z 188.9 and m/z 367.0 → m/z 188.9 for indapamide and IS, respectively. Calibration curve was constructed over the range 0.25–50 ng/mL. The method was precise and accurate, and provided recovery rates &gt;80% for indapamide and IS. The method was applied to determine blood concentrations of indapamide in a bioequivalence study with two sustained release tablet formulations. The 90% confidence interval for the geometric mean ratios for maximum concentration was 95.78% and for the area under the concentration–time curve it was 97.91%. The tested indapamide tablets (Eurofarma Laboratórios S.A.) were bioequivalent to Natrilix®, according to the rate and extent of absorption. Copyright © 2014 John Wiley &amp; Sons, Ltd.</description><identifier>ISSN: 0269-3879</identifier><identifier>EISSN: 1099-0801</identifier><identifier>DOI: 10.1002/bmc.3148</identifier><identifier>PMID: 24752891</identifier><language>eng</language><publisher>England: Blackwell Publishing Ltd</publisher><subject>Adolescent ; Adult ; bioequivalence ; Chromatography, Liquid - methods ; Humans ; indapamide ; Indapamide - blood ; Indapamide - chemistry ; Indapamide - pharmacokinetics ; LC-MS/MS ; Male ; Middle Aged ; Reproducibility of Results ; Sensitivity and Specificity ; Spectrometry, Mass, Electrospray Ionization ; Tandem Mass Spectrometry - methods ; Therapeutic Equivalency ; whole blood ; Young Adult</subject><ispartof>Biomedical chromatography, 2014-09, Vol.28 (9), p.1212-1218</ispartof><rights>Copyright © 2014 John Wiley &amp; Sons, Ltd.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4298-25f2fc1db418277c8108b6496fa3c034fce433d6ab4f6caf36598a97488e16cc3</citedby><cites>FETCH-LOGICAL-c4298-25f2fc1db418277c8108b6496fa3c034fce433d6ab4f6caf36598a97488e16cc3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fbmc.3148$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fbmc.3148$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,27903,27904,45553,45554</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24752891$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Pinto, Guilherme Araújo</creatorcontrib><creatorcontrib>Pastre, Kátia Isabel Fercondini</creatorcontrib><creatorcontrib>Bellorio, Karini Bruno</creatorcontrib><creatorcontrib>de Souza Teixeira, Leonardo</creatorcontrib><creatorcontrib>de Souza, Weidson Carlo</creatorcontrib><creatorcontrib>de Abreu, Fernanda Crunivel</creatorcontrib><creatorcontrib>de Santana e Silva Cardoso, Fabiana Fernandes</creatorcontrib><creatorcontrib>Pianetti, Gerson Antônio</creatorcontrib><creatorcontrib>César, Isabela Costa</creatorcontrib><title>An improved LC-MS/MS method for quantitation of indapamide in whole blood: application for a bioequivalence study</title><title>Biomedical chromatography</title><addtitle>Biomed. Chromatogr</addtitle><description>ABSTRACT An improved LC‐MS/MS method for the quantitation of indapamide in human whole blood was developed and validated. Indapamide‐d3 was used as internal standard (IS) and liquid–liquid extraction was employed for sample preparation. LC separation was performed on Synergi Polar RP‐column (50 × 4.6 mm i.d.; 4 µm) and mobile phase composed of methanol and 5 mm aqueous ammonium acetate containing 1 mm formic acid (60:40), at flow rate of 1 mL/min. The run time was 3.0 min and the injection volume was 20 μL. Mass spectrometric detection was performed using electrospray ion source in negative ionization mode, using the transitions m/z 364.0 → m/z 188.9 and m/z 367.0 → m/z 188.9 for indapamide and IS, respectively. Calibration curve was constructed over the range 0.25–50 ng/mL. The method was precise and accurate, and provided recovery rates &gt;80% for indapamide and IS. The method was applied to determine blood concentrations of indapamide in a bioequivalence study with two sustained release tablet formulations. The 90% confidence interval for the geometric mean ratios for maximum concentration was 95.78% and for the area under the concentration–time curve it was 97.91%. The tested indapamide tablets (Eurofarma Laboratórios S.A.) were bioequivalent to Natrilix®, according to the rate and extent of absorption. Copyright © 2014 John Wiley &amp; Sons, Ltd.</description><subject>Adolescent</subject><subject>Adult</subject><subject>bioequivalence</subject><subject>Chromatography, Liquid - methods</subject><subject>Humans</subject><subject>indapamide</subject><subject>Indapamide - blood</subject><subject>Indapamide - chemistry</subject><subject>Indapamide - pharmacokinetics</subject><subject>LC-MS/MS</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Reproducibility of Results</subject><subject>Sensitivity and Specificity</subject><subject>Spectrometry, Mass, Electrospray Ionization</subject><subject>Tandem Mass Spectrometry - methods</subject><subject>Therapeutic Equivalency</subject><subject>whole blood</subject><subject>Young Adult</subject><issn>0269-3879</issn><issn>1099-0801</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kMtO3DAUQK2qVZnSSnxB5WU3Ab_iBzsatRRpBlpBy9Jy_BAuSZyJE2D-noxmSles7l2ce6R7ADjC6BgjRE7q1h5TzOQbsMBIqQJJhN-CBSJcFVQKdQA-5PwXIaQ4Ee_BAWGiJFLhBVifdTC2_ZAevIPLqlhdn6yuYevHu-RgSANcT6Yb42jGmDqYAoydM71po_PzCh_vUuNh3aTkTqHp-ybaHbk9NbCOya-n-GAa31kP8zi5zUfwLpgm-0_7eQh-f_92U_0ollfnF9XZsrCMKFmQMpBgsasZlkQIKzGSNWeKB0MtoixYzyh13NQscGsC5aWSRgkmpcfcWnoIvuy883PryedRtzFb3zSm82nKGpcloVwKJP6jdkg5Dz7ofoitGTYaI70NrOfAeht4Rj_vrVPdevcC_is6A8UOeIyN37wq0l9X1V6452Me_dMLb4Z7zQUVpb69PNdqefPzzy9eaU6fASajk7k</recordid><startdate>201409</startdate><enddate>201409</enddate><creator>Pinto, Guilherme Araújo</creator><creator>Pastre, Kátia Isabel Fercondini</creator><creator>Bellorio, Karini Bruno</creator><creator>de Souza Teixeira, Leonardo</creator><creator>de Souza, Weidson Carlo</creator><creator>de Abreu, Fernanda Crunivel</creator><creator>de Santana e Silva Cardoso, Fabiana Fernandes</creator><creator>Pianetti, Gerson Antônio</creator><creator>César, Isabela Costa</creator><general>Blackwell Publishing Ltd</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201409</creationdate><title>An improved LC-MS/MS method for quantitation of indapamide in whole blood: application for a bioequivalence study</title><author>Pinto, Guilherme Araújo ; Pastre, Kátia Isabel Fercondini ; Bellorio, Karini Bruno ; de Souza Teixeira, Leonardo ; de Souza, Weidson Carlo ; de Abreu, Fernanda Crunivel ; de Santana e Silva Cardoso, Fabiana Fernandes ; Pianetti, Gerson Antônio ; César, Isabela Costa</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4298-25f2fc1db418277c8108b6496fa3c034fce433d6ab4f6caf36598a97488e16cc3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Adolescent</topic><topic>Adult</topic><topic>bioequivalence</topic><topic>Chromatography, Liquid - methods</topic><topic>Humans</topic><topic>indapamide</topic><topic>Indapamide - blood</topic><topic>Indapamide - chemistry</topic><topic>Indapamide - pharmacokinetics</topic><topic>LC-MS/MS</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Reproducibility of Results</topic><topic>Sensitivity and Specificity</topic><topic>Spectrometry, Mass, Electrospray Ionization</topic><topic>Tandem Mass Spectrometry - methods</topic><topic>Therapeutic Equivalency</topic><topic>whole blood</topic><topic>Young Adult</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Pinto, Guilherme Araújo</creatorcontrib><creatorcontrib>Pastre, Kátia Isabel Fercondini</creatorcontrib><creatorcontrib>Bellorio, Karini Bruno</creatorcontrib><creatorcontrib>de Souza Teixeira, Leonardo</creatorcontrib><creatorcontrib>de Souza, Weidson Carlo</creatorcontrib><creatorcontrib>de Abreu, Fernanda Crunivel</creatorcontrib><creatorcontrib>de Santana e Silva Cardoso, Fabiana Fernandes</creatorcontrib><creatorcontrib>Pianetti, Gerson Antônio</creatorcontrib><creatorcontrib>César, Isabela Costa</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Biomedical chromatography</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Pinto, Guilherme Araújo</au><au>Pastre, Kátia Isabel Fercondini</au><au>Bellorio, Karini Bruno</au><au>de Souza Teixeira, Leonardo</au><au>de Souza, Weidson Carlo</au><au>de Abreu, Fernanda Crunivel</au><au>de Santana e Silva Cardoso, Fabiana Fernandes</au><au>Pianetti, Gerson Antônio</au><au>César, Isabela Costa</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>An improved LC-MS/MS method for quantitation of indapamide in whole blood: application for a bioequivalence study</atitle><jtitle>Biomedical chromatography</jtitle><addtitle>Biomed. Chromatogr</addtitle><date>2014-09</date><risdate>2014</risdate><volume>28</volume><issue>9</issue><spage>1212</spage><epage>1218</epage><pages>1212-1218</pages><issn>0269-3879</issn><eissn>1099-0801</eissn><abstract>ABSTRACT An improved LC‐MS/MS method for the quantitation of indapamide in human whole blood was developed and validated. Indapamide‐d3 was used as internal standard (IS) and liquid–liquid extraction was employed for sample preparation. LC separation was performed on Synergi Polar RP‐column (50 × 4.6 mm i.d.; 4 µm) and mobile phase composed of methanol and 5 mm aqueous ammonium acetate containing 1 mm formic acid (60:40), at flow rate of 1 mL/min. The run time was 3.0 min and the injection volume was 20 μL. Mass spectrometric detection was performed using electrospray ion source in negative ionization mode, using the transitions m/z 364.0 → m/z 188.9 and m/z 367.0 → m/z 188.9 for indapamide and IS, respectively. Calibration curve was constructed over the range 0.25–50 ng/mL. The method was precise and accurate, and provided recovery rates &gt;80% for indapamide and IS. The method was applied to determine blood concentrations of indapamide in a bioequivalence study with two sustained release tablet formulations. The 90% confidence interval for the geometric mean ratios for maximum concentration was 95.78% and for the area under the concentration–time curve it was 97.91%. The tested indapamide tablets (Eurofarma Laboratórios S.A.) were bioequivalent to Natrilix®, according to the rate and extent of absorption. Copyright © 2014 John Wiley &amp; Sons, Ltd.</abstract><cop>England</cop><pub>Blackwell Publishing Ltd</pub><pmid>24752891</pmid><doi>10.1002/bmc.3148</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0269-3879
ispartof Biomedical chromatography, 2014-09, Vol.28 (9), p.1212-1218
issn 0269-3879
1099-0801
language eng
recordid cdi_proquest_miscellaneous_1552368707
source MEDLINE; Wiley Online Library Journals Frontfile Complete
subjects Adolescent
Adult
bioequivalence
Chromatography, Liquid - methods
Humans
indapamide
Indapamide - blood
Indapamide - chemistry
Indapamide - pharmacokinetics
LC-MS/MS
Male
Middle Aged
Reproducibility of Results
Sensitivity and Specificity
Spectrometry, Mass, Electrospray Ionization
Tandem Mass Spectrometry - methods
Therapeutic Equivalency
whole blood
Young Adult
title An improved LC-MS/MS method for quantitation of indapamide in whole blood: application for a bioequivalence study
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-23T05%3A29%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=An%20improved%20LC-MS/MS%20method%20for%20quantitation%20of%20indapamide%20in%20whole%20blood:%20application%20for%20a%20bioequivalence%20study&rft.jtitle=Biomedical%20chromatography&rft.au=Pinto,%20Guilherme%20Ara%C3%BAjo&rft.date=2014-09&rft.volume=28&rft.issue=9&rft.spage=1212&rft.epage=1218&rft.pages=1212-1218&rft.issn=0269-3879&rft.eissn=1099-0801&rft_id=info:doi/10.1002/bmc.3148&rft_dat=%3Cproquest_cross%3E1552368707%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1552368707&rft_id=info:pmid/24752891&rfr_iscdi=true