Accuracy of fluoroscopically-assisted pedicle screw placement: analysis of 1,218 screws in 198 patients
Abstract Background context We retrospectively analyzed a total of 1,218 pedicle screws for accuracy, with postoperative computed tomography (CT), in 198 patients who were operated on between March 2004 and September 2012. Purpose To determine the incidence of screw misplacement in patients who rece...
Gespeichert in:
Veröffentlicht in: | The spine journal 2014-08, Vol.14 (8), p.1702-1708 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract Background context We retrospectively analyzed a total of 1,218 pedicle screws for accuracy, with postoperative computed tomography (CT), in 198 patients who were operated on between March 2004 and September 2012. Purpose To determine the incidence of screw misplacement in patients who received a transpedicular screw fixation, with intraoperative fluoroscopy in the lateral and lateral with anteroposterior (AP) positions. The results are compared between the two groups. Study design Retrospective comparative study of accuracy of pedicle screw placement in thoracic and lumbar spine. Patient sample The sample consists of 198 consecutive patients who underwent transpedicular screw fixation. Outcome measures Accuracy of screw placement was evaluated by postoperative CT scan. Misplacement was defined in cases where more than 25% of the screw size was residing outside the pedicle. Methods The indications for hardware placement, radiologic studies, patient demographics, and reoperation rates were recorded. Five hundred twenty-eight screws (Group A, n=81) were inserted into the vertebral body with the assistance of lateral fluoroscopy only, whereas 690 screws (Group B, n=117) were inserted with the assistance of lateral fluoroscopy, and the final positions of the screws were checked with AP fluoroscopy. Results A total of 1,218 screws were analyzed, with 962 screws placed at the lumbosacral region and 256 screws at the thoracic region. According to the postoperative CT scan, 27 screws (2.2%) were identified as breaching the pedicle. Nineteen of them (3.6%) were in Group A, whereas 8 (1.16%) were in Group B. The rate of pedicle breaches was significantly different between Group A and B (p=.0052). In Group A, the lateral violation of the pedicle was seen in 10 screws (1.9%), whereas medial violation was seen in 9 screws (1.7%). In Group B, the lateral violation of the pedicle was seen in six screws (0.87%), whereas medial violation was seen in two screws (0.29%). The medial and lateral penetration of screws were significantly different between Groups A and B (p |
---|---|
ISSN: | 1529-9430 1878-1632 |
DOI: | 10.1016/j.spinee.2014.03.044 |