High Precision Analog Data Acquisition System with Signal Transformer Isolation Technique

In the field of Factory Automation (FA), process control, and Supervisory Control and Data Acquisition (SCADA), an analog data acquisition system using isolation transformers is commonly used to measure and record analog signals through isolated inputs. In order to improve the input precision of the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEICE transactions on fundamentals of electronics, communications and computer sciences communications and computer sciences, 2014-05, Vol.E96.A (6), p.1421-1428
Hauptverfasser: Akeboshi, Yoshihiro, Saito, Seiichi, Ohashi, Hideyuki
Format: Artikel
Sprache:jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1428
container_issue 6
container_start_page 1421
container_title IEICE transactions on fundamentals of electronics, communications and computer sciences
container_volume E96.A
creator Akeboshi, Yoshihiro
Saito, Seiichi
Ohashi, Hideyuki
description In the field of Factory Automation (FA), process control, and Supervisory Control and Data Acquisition (SCADA), an analog data acquisition system using isolation transformers is commonly used to measure and record analog signals through isolated inputs. In order to improve the input precision of the acquisition system, circuit techniques and a design method of the analog frontend circuit with the signal transformers are proposed in this paper. A circuit technique to compensate for the droop of the pulse signal due to the characteristics of the signal transformer is employed. Also, a numerical analysis of a non-linear circuit equation, which represents a behavior of the core saturation of the signal transformer, is performed in order to determine the parameters of the circuit. Using a small signal transformer, dedicatedly developed for this acquisition system, the performance of the precision achieved for the linearity error is experimentally confirmed within +0.0204%/-0.0215%.
doi_str_mv 10.1587/transfun.E96.A.1421
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_1541426833</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1541426833</sourcerecordid><originalsourceid>FETCH-LOGICAL-j903-c9c561c21f3afc027f0b78579ea31096f09440cb3e8934c6439b29df0577520d3</originalsourceid><addsrcrecordid>eNotkEtLw0AYRQdRsNT-AjezdJP4Tea9DLXaQkGh2bgqk-lMMpKHzSSI_95YXV04XO6Bi9A9gZRwJR_HwXTRT1260SLNU8IycoUWRDKeEErlNVqAJiJRHNQtWsUYSiCCKyWBL9D7NlQ1fhucDTH0Hc470_QVfjKjwbk9TzMdf_nhO46uxV9hrPEhVHMLFxdvP7RuwLvYN-ZSLJytu3Ce3B268aaJbvWfS1Q8b4r1Ntm_vuzW-T750EATqy0XxGbEU-MtZNJDKRWX2hlKQAsPmjGwJXVKU2YFo7rM9MkDl5JncKJL9PA3-zn0szWOxzZE65rGdK6f4pFwNj8iFKX0B-ktWKg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1541426833</pqid></control><display><type>article</type><title>High Precision Analog Data Acquisition System with Signal Transformer Isolation Technique</title><source>J-STAGE Free</source><creator>Akeboshi, Yoshihiro ; Saito, Seiichi ; Ohashi, Hideyuki</creator><creatorcontrib>Akeboshi, Yoshihiro ; Saito, Seiichi ; Ohashi, Hideyuki</creatorcontrib><description>In the field of Factory Automation (FA), process control, and Supervisory Control and Data Acquisition (SCADA), an analog data acquisition system using isolation transformers is commonly used to measure and record analog signals through isolated inputs. In order to improve the input precision of the acquisition system, circuit techniques and a design method of the analog frontend circuit with the signal transformers are proposed in this paper. A circuit technique to compensate for the droop of the pulse signal due to the characteristics of the signal transformer is employed. Also, a numerical analysis of a non-linear circuit equation, which represents a behavior of the core saturation of the signal transformer, is performed in order to determine the parameters of the circuit. Using a small signal transformer, dedicatedly developed for this acquisition system, the performance of the precision achieved for the linearity error is experimentally confirmed within +0.0204%/-0.0215%.</description><identifier>ISSN: 0916-8508</identifier><identifier>EISSN: 1745-1337</identifier><identifier>DOI: 10.1587/transfun.E96.A.1421</identifier><language>jpn</language><subject>Analog data ; Circuit design ; Circuits ; Marketing ; Mathematical analysis ; Mathematical models ; Supervisory control and data acquisition ; Transformers</subject><ispartof>IEICE transactions on fundamentals of electronics, communications and computer sciences, 2014-05, Vol.E96.A (6), p.1421-1428</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Akeboshi, Yoshihiro</creatorcontrib><creatorcontrib>Saito, Seiichi</creatorcontrib><creatorcontrib>Ohashi, Hideyuki</creatorcontrib><title>High Precision Analog Data Acquisition System with Signal Transformer Isolation Technique</title><title>IEICE transactions on fundamentals of electronics, communications and computer sciences</title><description>In the field of Factory Automation (FA), process control, and Supervisory Control and Data Acquisition (SCADA), an analog data acquisition system using isolation transformers is commonly used to measure and record analog signals through isolated inputs. In order to improve the input precision of the acquisition system, circuit techniques and a design method of the analog frontend circuit with the signal transformers are proposed in this paper. A circuit technique to compensate for the droop of the pulse signal due to the characteristics of the signal transformer is employed. Also, a numerical analysis of a non-linear circuit equation, which represents a behavior of the core saturation of the signal transformer, is performed in order to determine the parameters of the circuit. Using a small signal transformer, dedicatedly developed for this acquisition system, the performance of the precision achieved for the linearity error is experimentally confirmed within +0.0204%/-0.0215%.</description><subject>Analog data</subject><subject>Circuit design</subject><subject>Circuits</subject><subject>Marketing</subject><subject>Mathematical analysis</subject><subject>Mathematical models</subject><subject>Supervisory control and data acquisition</subject><subject>Transformers</subject><issn>0916-8508</issn><issn>1745-1337</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNotkEtLw0AYRQdRsNT-AjezdJP4Tea9DLXaQkGh2bgqk-lMMpKHzSSI_95YXV04XO6Bi9A9gZRwJR_HwXTRT1260SLNU8IycoUWRDKeEErlNVqAJiJRHNQtWsUYSiCCKyWBL9D7NlQ1fhucDTH0Hc470_QVfjKjwbk9TzMdf_nhO46uxV9hrPEhVHMLFxdvP7RuwLvYN-ZSLJytu3Ce3B268aaJbvWfS1Q8b4r1Ntm_vuzW-T750EATqy0XxGbEU-MtZNJDKRWX2hlKQAsPmjGwJXVKU2YFo7rM9MkDl5JncKJL9PA3-zn0szWOxzZE65rGdK6f4pFwNj8iFKX0B-ktWKg</recordid><startdate>20140509</startdate><enddate>20140509</enddate><creator>Akeboshi, Yoshihiro</creator><creator>Saito, Seiichi</creator><creator>Ohashi, Hideyuki</creator><scope>7SC</scope><scope>7SP</scope><scope>8FD</scope><scope>JQ2</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope></search><sort><creationdate>20140509</creationdate><title>High Precision Analog Data Acquisition System with Signal Transformer Isolation Technique</title><author>Akeboshi, Yoshihiro ; Saito, Seiichi ; Ohashi, Hideyuki</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-j903-c9c561c21f3afc027f0b78579ea31096f09440cb3e8934c6439b29df0577520d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>jpn</language><creationdate>2014</creationdate><topic>Analog data</topic><topic>Circuit design</topic><topic>Circuits</topic><topic>Marketing</topic><topic>Mathematical analysis</topic><topic>Mathematical models</topic><topic>Supervisory control and data acquisition</topic><topic>Transformers</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Akeboshi, Yoshihiro</creatorcontrib><creatorcontrib>Saito, Seiichi</creatorcontrib><creatorcontrib>Ohashi, Hideyuki</creatorcontrib><collection>Computer and Information Systems Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Technology Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><jtitle>IEICE transactions on fundamentals of electronics, communications and computer sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Akeboshi, Yoshihiro</au><au>Saito, Seiichi</au><au>Ohashi, Hideyuki</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>High Precision Analog Data Acquisition System with Signal Transformer Isolation Technique</atitle><jtitle>IEICE transactions on fundamentals of electronics, communications and computer sciences</jtitle><date>2014-05-09</date><risdate>2014</risdate><volume>E96.A</volume><issue>6</issue><spage>1421</spage><epage>1428</epage><pages>1421-1428</pages><issn>0916-8508</issn><eissn>1745-1337</eissn><abstract>In the field of Factory Automation (FA), process control, and Supervisory Control and Data Acquisition (SCADA), an analog data acquisition system using isolation transformers is commonly used to measure and record analog signals through isolated inputs. In order to improve the input precision of the acquisition system, circuit techniques and a design method of the analog frontend circuit with the signal transformers are proposed in this paper. A circuit technique to compensate for the droop of the pulse signal due to the characteristics of the signal transformer is employed. Also, a numerical analysis of a non-linear circuit equation, which represents a behavior of the core saturation of the signal transformer, is performed in order to determine the parameters of the circuit. Using a small signal transformer, dedicatedly developed for this acquisition system, the performance of the precision achieved for the linearity error is experimentally confirmed within +0.0204%/-0.0215%.</abstract><doi>10.1587/transfun.E96.A.1421</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0916-8508
ispartof IEICE transactions on fundamentals of electronics, communications and computer sciences, 2014-05, Vol.E96.A (6), p.1421-1428
issn 0916-8508
1745-1337
language jpn
recordid cdi_proquest_miscellaneous_1541426833
source J-STAGE Free
subjects Analog data
Circuit design
Circuits
Marketing
Mathematical analysis
Mathematical models
Supervisory control and data acquisition
Transformers
title High Precision Analog Data Acquisition System with Signal Transformer Isolation Technique
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T11%3A48%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=High%20Precision%20Analog%20Data%20Acquisition%20System%20with%20Signal%20Transformer%20Isolation%20Technique&rft.jtitle=IEICE%20transactions%20on%20fundamentals%20of%20electronics,%20communications%20and%20computer%20sciences&rft.au=Akeboshi,%20Yoshihiro&rft.date=2014-05-09&rft.volume=E96.A&rft.issue=6&rft.spage=1421&rft.epage=1428&rft.pages=1421-1428&rft.issn=0916-8508&rft.eissn=1745-1337&rft_id=info:doi/10.1587/transfun.E96.A.1421&rft_dat=%3Cproquest%3E1541426833%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1541426833&rft_id=info:pmid/&rfr_iscdi=true