Comparison of Pulp Stump Wounds Created by ProFile Rotary Root Canal Instruments and Small-diameter Fine Diamond Burs
Abstract Introduction The aim of this investigation was to evaluate and compare the pulp stump wounds created by the following root canal instruments: ProFile rotary files and small-diameter fine diamond burs. Methods Extracted mandibular premolars from adult patients with vital pulps and fully form...
Gespeichert in:
Veröffentlicht in: | Journal of endodontics 2014-07, Vol.40 (7), p.949-952 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 952 |
---|---|
container_issue | 7 |
container_start_page | 949 |
container_title | Journal of endodontics |
container_volume | 40 |
creator | Nelson, Taylor T., DMD Eleazer, Paul D., DDS, MS Ramp, Lance C., DMD, MSBE, PhD |
description | Abstract Introduction The aim of this investigation was to evaluate and compare the pulp stump wounds created by the following root canal instruments: ProFile rotary files and small-diameter fine diamond burs. Methods Extracted mandibular premolars from adult patients with vital pulps and fully formed root canals were collected and stored in formalin. Within 48 hours of extraction, the periapical tissue was fixated to the root with a double coating of ethyl cyanoacrylate, and the pulp chambers were accessed with a #4 round carbide bur and high-speed handpiece in a traditional fashion. The pulp tissue of 10 specimens per group was extirpated at a level approximately 5 mm from the apex by using standard endodontic techniques. The specimens were then examined at ×100 magnification under a digital microscope. Grading criteria were developed, and the wounds were scored. Results Wounds created by diamond burs were significantly smoother that those created by ProFile rotary files; the mean wound score for diamond burs was 1.4 versus a mean wound score of 3 for ProFiles. After the author's scoring of the wounds, 2 endodontist graders were shown photos of each specimen in a double-blind fashion and instructed to score each specimen as being smooth or rough. To validate the developed scoring system and remove potential observer bias of the author, the data from the double-blind observations were used to complete a cross-tabulation for a Cohen kappa test. Conclusions Kappa values demonstrated substantial inter-rater agreement for both groups. |
doi_str_mv | 10.1016/j.joen.2013.11.003 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1537184922</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>1_s2_0_S0099239913010224</els_id><sourcerecordid>1537184922</sourcerecordid><originalsourceid>FETCH-LOGICAL-c277t-4d1c3af2b6e634ffc844fffc5e6523509e9e57bf88bcf85eb0caefc1a5037f473</originalsourceid><addsrcrecordid>eNp9kc2r1DAUxYMovvHpP-BCsnTTmo922oIIWh198MCHo7gMaXoDGdOk5kOY_96Uebpw4SaXcM85cH4XoeeU1JTQ_atTffLgakYorymtCeEP0I72XV_xtm0eoh0hw1AxPgxX6EmMJ0Jox3n3GF2xZtgkdIfy6JdVBhO9w17ju2xXfEx5WfF3n90c8RhAJpjxdMZ3wR-MBfzFJxnOZfiER-mkxTcuppAXcCli6WZ8XKS11WzkAgkCPhgH-H35-bJ7l0N8ih5paSM8u5_X6Nvhw9fxU3X7-ePN-Pa2UqzrUtXMVHGp2bSHPW-0Vn1TXq1a2LeMt2SAAdpu0n0_Kd23MBElQSsqW8I73XT8Gr285K7B_8wQk1hMVGCtdOBzFLTlHe2bgbEiZRepCj7GAFqswSylp6BEbLjFSWy4xYZbUCoK7mJ6cZ-fpwXmv5Y_fIvg9UUApeUvA0FEZcApmE0AlcTszf_z3_xjV9Y4o6T9AWeIJ59DwV96iMgEEcft4Nu9KSeUMNbw39jyp1U</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1537184922</pqid></control><display><type>article</type><title>Comparison of Pulp Stump Wounds Created by ProFile Rotary Root Canal Instruments and Small-diameter Fine Diamond Burs</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>Nelson, Taylor T., DMD ; Eleazer, Paul D., DDS, MS ; Ramp, Lance C., DMD, MSBE, PhD</creator><creatorcontrib>Nelson, Taylor T., DMD ; Eleazer, Paul D., DDS, MS ; Ramp, Lance C., DMD, MSBE, PhD</creatorcontrib><description>Abstract Introduction The aim of this investigation was to evaluate and compare the pulp stump wounds created by the following root canal instruments: ProFile rotary files and small-diameter fine diamond burs. Methods Extracted mandibular premolars from adult patients with vital pulps and fully formed root canals were collected and stored in formalin. Within 48 hours of extraction, the periapical tissue was fixated to the root with a double coating of ethyl cyanoacrylate, and the pulp chambers were accessed with a #4 round carbide bur and high-speed handpiece in a traditional fashion. The pulp tissue of 10 specimens per group was extirpated at a level approximately 5 mm from the apex by using standard endodontic techniques. The specimens were then examined at ×100 magnification under a digital microscope. Grading criteria were developed, and the wounds were scored. Results Wounds created by diamond burs were significantly smoother that those created by ProFile rotary files; the mean wound score for diamond burs was 1.4 versus a mean wound score of 3 for ProFiles. After the author's scoring of the wounds, 2 endodontist graders were shown photos of each specimen in a double-blind fashion and instructed to score each specimen as being smooth or rough. To validate the developed scoring system and remove potential observer bias of the author, the data from the double-blind observations were used to complete a cross-tabulation for a Cohen kappa test. Conclusions Kappa values demonstrated substantial inter-rater agreement for both groups.</description><identifier>ISSN: 0099-2399</identifier><identifier>EISSN: 1878-3554</identifier><identifier>DOI: 10.1016/j.joen.2013.11.003</identifier><identifier>PMID: 24935541</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Adult ; Dental High-Speed Equipment ; Dental Pulp - pathology ; Dental Pulp Cavity - pathology ; Dentistry ; Diamond - chemistry ; Diamond bur ; Double-Blind Method ; Endocrinology & Metabolism ; Equipment Design ; Humans ; Image Processing, Computer-Assisted - methods ; Imaging, Three-Dimensional - methods ; inflammation ; Materials Testing ; Observer Variation ; Photography - methods ; pulp ; Pulpectomy - instrumentation ; Root Canal Preparation - instrumentation ; Rotation ; Tooth Apex - pathology ; wound</subject><ispartof>Journal of endodontics, 2014-07, Vol.40 (7), p.949-952</ispartof><rights>American Association of Endodontists</rights><rights>2014 American Association of Endodontists</rights><rights>Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c277t-4d1c3af2b6e634ffc844fffc5e6523509e9e57bf88bcf85eb0caefc1a5037f473</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.joen.2013.11.003$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24935541$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Nelson, Taylor T., DMD</creatorcontrib><creatorcontrib>Eleazer, Paul D., DDS, MS</creatorcontrib><creatorcontrib>Ramp, Lance C., DMD, MSBE, PhD</creatorcontrib><title>Comparison of Pulp Stump Wounds Created by ProFile Rotary Root Canal Instruments and Small-diameter Fine Diamond Burs</title><title>Journal of endodontics</title><addtitle>J Endod</addtitle><description>Abstract Introduction The aim of this investigation was to evaluate and compare the pulp stump wounds created by the following root canal instruments: ProFile rotary files and small-diameter fine diamond burs. Methods Extracted mandibular premolars from adult patients with vital pulps and fully formed root canals were collected and stored in formalin. Within 48 hours of extraction, the periapical tissue was fixated to the root with a double coating of ethyl cyanoacrylate, and the pulp chambers were accessed with a #4 round carbide bur and high-speed handpiece in a traditional fashion. The pulp tissue of 10 specimens per group was extirpated at a level approximately 5 mm from the apex by using standard endodontic techniques. The specimens were then examined at ×100 magnification under a digital microscope. Grading criteria were developed, and the wounds were scored. Results Wounds created by diamond burs were significantly smoother that those created by ProFile rotary files; the mean wound score for diamond burs was 1.4 versus a mean wound score of 3 for ProFiles. After the author's scoring of the wounds, 2 endodontist graders were shown photos of each specimen in a double-blind fashion and instructed to score each specimen as being smooth or rough. To validate the developed scoring system and remove potential observer bias of the author, the data from the double-blind observations were used to complete a cross-tabulation for a Cohen kappa test. Conclusions Kappa values demonstrated substantial inter-rater agreement for both groups.</description><subject>Adult</subject><subject>Dental High-Speed Equipment</subject><subject>Dental Pulp - pathology</subject><subject>Dental Pulp Cavity - pathology</subject><subject>Dentistry</subject><subject>Diamond - chemistry</subject><subject>Diamond bur</subject><subject>Double-Blind Method</subject><subject>Endocrinology & Metabolism</subject><subject>Equipment Design</subject><subject>Humans</subject><subject>Image Processing, Computer-Assisted - methods</subject><subject>Imaging, Three-Dimensional - methods</subject><subject>inflammation</subject><subject>Materials Testing</subject><subject>Observer Variation</subject><subject>Photography - methods</subject><subject>pulp</subject><subject>Pulpectomy - instrumentation</subject><subject>Root Canal Preparation - instrumentation</subject><subject>Rotation</subject><subject>Tooth Apex - pathology</subject><subject>wound</subject><issn>0099-2399</issn><issn>1878-3554</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kc2r1DAUxYMovvHpP-BCsnTTmo922oIIWh198MCHo7gMaXoDGdOk5kOY_96Uebpw4SaXcM85cH4XoeeU1JTQ_atTffLgakYorymtCeEP0I72XV_xtm0eoh0hw1AxPgxX6EmMJ0Jox3n3GF2xZtgkdIfy6JdVBhO9w17ju2xXfEx5WfF3n90c8RhAJpjxdMZ3wR-MBfzFJxnOZfiER-mkxTcuppAXcCli6WZ8XKS11WzkAgkCPhgH-H35-bJ7l0N8ih5paSM8u5_X6Nvhw9fxU3X7-ePN-Pa2UqzrUtXMVHGp2bSHPW-0Vn1TXq1a2LeMt2SAAdpu0n0_Kd23MBElQSsqW8I73XT8Gr285K7B_8wQk1hMVGCtdOBzFLTlHe2bgbEiZRepCj7GAFqswSylp6BEbLjFSWy4xYZbUCoK7mJ6cZ-fpwXmv5Y_fIvg9UUApeUvA0FEZcApmE0AlcTszf_z3_xjV9Y4o6T9AWeIJ59DwV96iMgEEcft4Nu9KSeUMNbw39jyp1U</recordid><startdate>201407</startdate><enddate>201407</enddate><creator>Nelson, Taylor T., DMD</creator><creator>Eleazer, Paul D., DDS, MS</creator><creator>Ramp, Lance C., DMD, MSBE, PhD</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201407</creationdate><title>Comparison of Pulp Stump Wounds Created by ProFile Rotary Root Canal Instruments and Small-diameter Fine Diamond Burs</title><author>Nelson, Taylor T., DMD ; Eleazer, Paul D., DDS, MS ; Ramp, Lance C., DMD, MSBE, PhD</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c277t-4d1c3af2b6e634ffc844fffc5e6523509e9e57bf88bcf85eb0caefc1a5037f473</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Adult</topic><topic>Dental High-Speed Equipment</topic><topic>Dental Pulp - pathology</topic><topic>Dental Pulp Cavity - pathology</topic><topic>Dentistry</topic><topic>Diamond - chemistry</topic><topic>Diamond bur</topic><topic>Double-Blind Method</topic><topic>Endocrinology & Metabolism</topic><topic>Equipment Design</topic><topic>Humans</topic><topic>Image Processing, Computer-Assisted - methods</topic><topic>Imaging, Three-Dimensional - methods</topic><topic>inflammation</topic><topic>Materials Testing</topic><topic>Observer Variation</topic><topic>Photography - methods</topic><topic>pulp</topic><topic>Pulpectomy - instrumentation</topic><topic>Root Canal Preparation - instrumentation</topic><topic>Rotation</topic><topic>Tooth Apex - pathology</topic><topic>wound</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Nelson, Taylor T., DMD</creatorcontrib><creatorcontrib>Eleazer, Paul D., DDS, MS</creatorcontrib><creatorcontrib>Ramp, Lance C., DMD, MSBE, PhD</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of endodontics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Nelson, Taylor T., DMD</au><au>Eleazer, Paul D., DDS, MS</au><au>Ramp, Lance C., DMD, MSBE, PhD</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of Pulp Stump Wounds Created by ProFile Rotary Root Canal Instruments and Small-diameter Fine Diamond Burs</atitle><jtitle>Journal of endodontics</jtitle><addtitle>J Endod</addtitle><date>2014-07</date><risdate>2014</risdate><volume>40</volume><issue>7</issue><spage>949</spage><epage>952</epage><pages>949-952</pages><issn>0099-2399</issn><eissn>1878-3554</eissn><abstract>Abstract Introduction The aim of this investigation was to evaluate and compare the pulp stump wounds created by the following root canal instruments: ProFile rotary files and small-diameter fine diamond burs. Methods Extracted mandibular premolars from adult patients with vital pulps and fully formed root canals were collected and stored in formalin. Within 48 hours of extraction, the periapical tissue was fixated to the root with a double coating of ethyl cyanoacrylate, and the pulp chambers were accessed with a #4 round carbide bur and high-speed handpiece in a traditional fashion. The pulp tissue of 10 specimens per group was extirpated at a level approximately 5 mm from the apex by using standard endodontic techniques. The specimens were then examined at ×100 magnification under a digital microscope. Grading criteria were developed, and the wounds were scored. Results Wounds created by diamond burs were significantly smoother that those created by ProFile rotary files; the mean wound score for diamond burs was 1.4 versus a mean wound score of 3 for ProFiles. After the author's scoring of the wounds, 2 endodontist graders were shown photos of each specimen in a double-blind fashion and instructed to score each specimen as being smooth or rough. To validate the developed scoring system and remove potential observer bias of the author, the data from the double-blind observations were used to complete a cross-tabulation for a Cohen kappa test. Conclusions Kappa values demonstrated substantial inter-rater agreement for both groups.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>24935541</pmid><doi>10.1016/j.joen.2013.11.003</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0099-2399 |
ispartof | Journal of endodontics, 2014-07, Vol.40 (7), p.949-952 |
issn | 0099-2399 1878-3554 |
language | eng |
recordid | cdi_proquest_miscellaneous_1537184922 |
source | MEDLINE; Access via ScienceDirect (Elsevier) |
subjects | Adult Dental High-Speed Equipment Dental Pulp - pathology Dental Pulp Cavity - pathology Dentistry Diamond - chemistry Diamond bur Double-Blind Method Endocrinology & Metabolism Equipment Design Humans Image Processing, Computer-Assisted - methods Imaging, Three-Dimensional - methods inflammation Materials Testing Observer Variation Photography - methods pulp Pulpectomy - instrumentation Root Canal Preparation - instrumentation Rotation Tooth Apex - pathology wound |
title | Comparison of Pulp Stump Wounds Created by ProFile Rotary Root Canal Instruments and Small-diameter Fine Diamond Burs |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-21T16%3A55%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20Pulp%20Stump%20Wounds%20Created%20by%20ProFile%20Rotary%20Root%20Canal%20Instruments%20and%20Small-diameter%20Fine%20Diamond%20Burs&rft.jtitle=Journal%20of%20endodontics&rft.au=Nelson,%20Taylor%20T.,%20DMD&rft.date=2014-07&rft.volume=40&rft.issue=7&rft.spage=949&rft.epage=952&rft.pages=949-952&rft.issn=0099-2399&rft.eissn=1878-3554&rft_id=info:doi/10.1016/j.joen.2013.11.003&rft_dat=%3Cproquest_cross%3E1537184922%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1537184922&rft_id=info:pmid/24935541&rft_els_id=1_s2_0_S0099239913010224&rfr_iscdi=true |