The Research of 10 kV Feeder Automation Based on the Upper PC System

As the basis of power distribution network automation, the feeder automation plays an important role in the distribution network. The traditional feeder automation system has a long fault isolation time, the frequent switching and outgoing and then overlap power filter troubleshooting repeatedly. 10...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied Mechanics and Materials 2014-03, Vol.543-547 (Vehicle, Mechatronics and Information Technologies II), p.834-837
Hauptverfasser: Du, Yu He, Piao, Zai Lin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 837
container_issue Vehicle, Mechatronics and Information Technologies II
container_start_page 834
container_title Applied Mechanics and Materials
container_volume 543-547
creator Du, Yu He
Piao, Zai Lin
description As the basis of power distribution network automation, the feeder automation plays an important role in the distribution network. The traditional feeder automation system has a long fault isolation time, the frequent switching and outgoing and then overlap power filter troubleshooting repeatedly. 10 kv feeder automation system in the thesis is controlled by the upper PC computer system and the lower machine system, and the lower machine system's intelligent controller collects the operation information of the voltage and current of the line being monitored in real time with AC-sampling technology, and through the GPRS wireless communication network will field data is passed to the remote control center. When the short circuit faults occur, the controller will immediately disconnect the switch, and the incorrect information will be sent to the remote control center, the remote control center to collect incorrect information from all the controllers, then provide the fault judgment and control strategy through relevant logic. Practices have proved that the system could improve the level and reliability of power distribution network effectively.
doi_str_mv 10.4028/www.scientific.net/AMM.543-547.834
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1531014060</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1531014060</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2994-bc5f21ab2f474bfe74cb2e64d291b8f1cecde6805fd3dde4c8414b1aafb191d03</originalsourceid><addsrcrecordid>eNqNkE1LxDAQhoMfoLv6HwJeRGhNmrRNj-v6CYqiq9eQphO2um3XpGXZf-_oCoonDyGBefLOzEPICWexZIk6Xa1WcbA1tH3tahu30J9O7u7iVIoolXmshNwi-zzLkiiXKtkmI8GEEinLWLrzVWBRIUS2R0YhvDKWSS7VPjmfzYE-QgDj7Zx2jnJG317oJUAFnk6GvmtMX3ctPTMBKoqPHj88L5dYfZjSp3XooTkgu84sAhx-32PyfHkxm15Ht_dXN9PJbWSTopBRaVOXcFMmTuaydJBLWyaQySopeKkct2AryBRLXSWqCqRVOGPJjXElL3jFxJgcb3KXvnsfIPS6qYOFxcK00A1B81RwxiWujOjRH_S1G3yL0yHFOUvzXCmkzjaU9V0IHpxe-roxfq0505_WNVrXP9Y1WtdoXaN1PLlG6xhyvgnpvWlRh53_6vX_mA9KOpFe</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1511057788</pqid></control><display><type>article</type><title>The Research of 10 kV Feeder Automation Based on the Upper PC System</title><source>Scientific.net Journals</source><creator>Du, Yu He ; Piao, Zai Lin</creator><creatorcontrib>Du, Yu He ; Piao, Zai Lin</creatorcontrib><description>As the basis of power distribution network automation, the feeder automation plays an important role in the distribution network. The traditional feeder automation system has a long fault isolation time, the frequent switching and outgoing and then overlap power filter troubleshooting repeatedly. 10 kv feeder automation system in the thesis is controlled by the upper PC computer system and the lower machine system, and the lower machine system's intelligent controller collects the operation information of the voltage and current of the line being monitored in real time with AC-sampling technology, and through the GPRS wireless communication network will field data is passed to the remote control center. When the short circuit faults occur, the controller will immediately disconnect the switch, and the incorrect information will be sent to the remote control center, the remote control center to collect incorrect information from all the controllers, then provide the fault judgment and control strategy through relevant logic. Practices have proved that the system could improve the level and reliability of power distribution network effectively.</description><identifier>ISSN: 1660-9336</identifier><identifier>ISSN: 1662-7482</identifier><identifier>ISBN: 3038350605</identifier><identifier>ISBN: 9783038350606</identifier><identifier>EISSN: 1662-7482</identifier><identifier>DOI: 10.4028/www.scientific.net/AMM.543-547.834</identifier><language>eng</language><publisher>Zurich: Trans Tech Publications Ltd</publisher><subject>Automation ; Faults ; Feeders ; Logic ; Networks ; Power distribution ; Remote control ; Switching theory</subject><ispartof>Applied Mechanics and Materials, 2014-03, Vol.543-547 (Vehicle, Mechatronics and Information Technologies II), p.834-837</ispartof><rights>2014 Trans Tech Publications Ltd</rights><rights>Copyright Trans Tech Publications Ltd. Mar 2014</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://www.scientific.net/Image/TitleCover/3082?width=600</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Du, Yu He</creatorcontrib><creatorcontrib>Piao, Zai Lin</creatorcontrib><title>The Research of 10 kV Feeder Automation Based on the Upper PC System</title><title>Applied Mechanics and Materials</title><description>As the basis of power distribution network automation, the feeder automation plays an important role in the distribution network. The traditional feeder automation system has a long fault isolation time, the frequent switching and outgoing and then overlap power filter troubleshooting repeatedly. 10 kv feeder automation system in the thesis is controlled by the upper PC computer system and the lower machine system, and the lower machine system's intelligent controller collects the operation information of the voltage and current of the line being monitored in real time with AC-sampling technology, and through the GPRS wireless communication network will field data is passed to the remote control center. When the short circuit faults occur, the controller will immediately disconnect the switch, and the incorrect information will be sent to the remote control center, the remote control center to collect incorrect information from all the controllers, then provide the fault judgment and control strategy through relevant logic. Practices have proved that the system could improve the level and reliability of power distribution network effectively.</description><subject>Automation</subject><subject>Faults</subject><subject>Feeders</subject><subject>Logic</subject><subject>Networks</subject><subject>Power distribution</subject><subject>Remote control</subject><subject>Switching theory</subject><issn>1660-9336</issn><issn>1662-7482</issn><issn>1662-7482</issn><isbn>3038350605</isbn><isbn>9783038350606</isbn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><recordid>eNqNkE1LxDAQhoMfoLv6HwJeRGhNmrRNj-v6CYqiq9eQphO2um3XpGXZf-_oCoonDyGBefLOzEPICWexZIk6Xa1WcbA1tH3tahu30J9O7u7iVIoolXmshNwi-zzLkiiXKtkmI8GEEinLWLrzVWBRIUS2R0YhvDKWSS7VPjmfzYE-QgDj7Zx2jnJG317oJUAFnk6GvmtMX3ctPTMBKoqPHj88L5dYfZjSp3XooTkgu84sAhx-32PyfHkxm15Ht_dXN9PJbWSTopBRaVOXcFMmTuaydJBLWyaQySopeKkct2AryBRLXSWqCqRVOGPJjXElL3jFxJgcb3KXvnsfIPS6qYOFxcK00A1B81RwxiWujOjRH_S1G3yL0yHFOUvzXCmkzjaU9V0IHpxe-roxfq0505_WNVrXP9Y1WtdoXaN1PLlG6xhyvgnpvWlRh53_6vX_mA9KOpFe</recordid><startdate>20140301</startdate><enddate>20140301</enddate><creator>Du, Yu He</creator><creator>Piao, Zai Lin</creator><general>Trans Tech Publications Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7TB</scope><scope>8BQ</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>BFMQW</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>FR3</scope><scope>HCIFZ</scope><scope>JG9</scope><scope>KB.</scope><scope>KR7</scope><scope>L6V</scope><scope>M7S</scope><scope>PDBOC</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20140301</creationdate><title>The Research of 10 kV Feeder Automation Based on the Upper PC System</title><author>Du, Yu He ; Piao, Zai Lin</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2994-bc5f21ab2f474bfe74cb2e64d291b8f1cecde6805fd3dde4c8414b1aafb191d03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Automation</topic><topic>Faults</topic><topic>Feeders</topic><topic>Logic</topic><topic>Networks</topic><topic>Power distribution</topic><topic>Remote control</topic><topic>Switching theory</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Du, Yu He</creatorcontrib><creatorcontrib>Piao, Zai Lin</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central</collection><collection>Continental Europe Database</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>Engineering Research Database</collection><collection>SciTech Premium Collection</collection><collection>Materials Research Database</collection><collection>Materials Science Database</collection><collection>Civil Engineering Abstracts</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Materials Science Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><jtitle>Applied Mechanics and Materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Du, Yu He</au><au>Piao, Zai Lin</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The Research of 10 kV Feeder Automation Based on the Upper PC System</atitle><jtitle>Applied Mechanics and Materials</jtitle><date>2014-03-01</date><risdate>2014</risdate><volume>543-547</volume><issue>Vehicle, Mechatronics and Information Technologies II</issue><spage>834</spage><epage>837</epage><pages>834-837</pages><issn>1660-9336</issn><issn>1662-7482</issn><eissn>1662-7482</eissn><isbn>3038350605</isbn><isbn>9783038350606</isbn><abstract>As the basis of power distribution network automation, the feeder automation plays an important role in the distribution network. The traditional feeder automation system has a long fault isolation time, the frequent switching and outgoing and then overlap power filter troubleshooting repeatedly. 10 kv feeder automation system in the thesis is controlled by the upper PC computer system and the lower machine system, and the lower machine system's intelligent controller collects the operation information of the voltage and current of the line being monitored in real time with AC-sampling technology, and through the GPRS wireless communication network will field data is passed to the remote control center. When the short circuit faults occur, the controller will immediately disconnect the switch, and the incorrect information will be sent to the remote control center, the remote control center to collect incorrect information from all the controllers, then provide the fault judgment and control strategy through relevant logic. Practices have proved that the system could improve the level and reliability of power distribution network effectively.</abstract><cop>Zurich</cop><pub>Trans Tech Publications Ltd</pub><doi>10.4028/www.scientific.net/AMM.543-547.834</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1660-9336
ispartof Applied Mechanics and Materials, 2014-03, Vol.543-547 (Vehicle, Mechatronics and Information Technologies II), p.834-837
issn 1660-9336
1662-7482
1662-7482
language eng
recordid cdi_proquest_miscellaneous_1531014060
source Scientific.net Journals
subjects Automation
Faults
Feeders
Logic
Networks
Power distribution
Remote control
Switching theory
title The Research of 10 kV Feeder Automation Based on the Upper PC System
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T06%3A10%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20Research%20of%2010%20kV%20Feeder%20Automation%20Based%20on%20the%20Upper%20PC%20System&rft.jtitle=Applied%20Mechanics%20and%20Materials&rft.au=Du,%20Yu%20He&rft.date=2014-03-01&rft.volume=543-547&rft.issue=Vehicle,%20Mechatronics%20and%20Information%20Technologies%20II&rft.spage=834&rft.epage=837&rft.pages=834-837&rft.issn=1660-9336&rft.eissn=1662-7482&rft.isbn=3038350605&rft.isbn_list=9783038350606&rft_id=info:doi/10.4028/www.scientific.net/AMM.543-547.834&rft_dat=%3Cproquest_cross%3E1531014060%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1511057788&rft_id=info:pmid/&rfr_iscdi=true