Effect of moisture swelling on MEMS packaging and integrated sensors
In MEMS packaging moisture uptake of packaging materials may lead to severe changes in sensor behavior and package reliability. Knowledge and understanding of the effect of moisture swelling on the overall package deformation and on the sensor system is therefore inevitable for a successful MEMS des...
Gespeichert in:
Veröffentlicht in: | Microelectronics and reliability 2013-09, Vol.53 (9-11), p.1648-1654 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1654 |
---|---|
container_issue | 9-11 |
container_start_page | 1648 |
container_title | Microelectronics and reliability |
container_volume | 53 |
creator | Keller, J. Mrossko, R. Dobrinski, H. Stürmann, J. Döring, R. Dudek, R. Rzepka, S. Michel, B. |
description | In MEMS packaging moisture uptake of packaging materials may lead to severe changes in sensor behavior and package reliability. Knowledge and understanding of the effect of moisture swelling on the overall package deformation and on the sensor system is therefore inevitable for a successful MEMS design and packaging solution. The paper shows a design optimization of a pressure sensor packaging towards minimization of sensor drift due to stresses induced by moisture uptake. The work was done in a combined experimental and simulative approach. Experimental data clearly shows the sensor sensitivity to moisture uptake of polymer based packaging material. Based on the experimental findings the complete sensor package was modeled by means of finite element analysis. In a second step a new packaging geometry was defined to reduce the effect of moisture swelling to sensor signal. Additionally sensitivity of the sensor output signal to viscoelastic properties of three different moulding compounds was simulated. In the result of the work an optimized package design was achieved. |
doi_str_mv | 10.1016/j.microrel.2013.07.107 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1531002172</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0026271413002837</els_id><sourcerecordid>1531002172</sourcerecordid><originalsourceid>FETCH-LOGICAL-c375t-44855de51f71ddcaee100829a24d2859c93c2c43fac426ae6f86eecc8dc427783</originalsourceid><addsrcrecordid>eNqFkE1LAzEQhoMoWKt_QXIRvOyaZD-ye1Nq_YAWDyp4CyGZlNTdpCZbxX9vllavnoZ5eeedmQehc0pySmh9tc57q4IP0OWM0CInPOn8AE1ow1nWlvTtEE0IYXXGOC2P0UmMa0IIJ5RO0O3cGFAD9gb33sZhGwDHL-g661bYO7ycL5_xRqp3uRoV6TS2boBVkANoHMFFH-IpOjKyi3C2r1P0ejd_mT1ki6f7x9nNIlMFr4asLJuq0lBRw6nWSgJQQhrWSlZq1lStagvFVFkYqUpWS6hNUwMo1ejUc94UU3S5y90E_7GFOIjeRpWOlQ78NgpaFSmRUc6Std5ZE5kYAxixCbaX4VtQIkZsYi1-sYkRmyA86TwNXux3yKhkZ4J0ysa_acbblE_HW653PkgPf1oIIioLToG2IQEV2tv_Vv0AZVWGsw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1531002172</pqid></control><display><type>article</type><title>Effect of moisture swelling on MEMS packaging and integrated sensors</title><source>Elsevier ScienceDirect Journals</source><creator>Keller, J. ; Mrossko, R. ; Dobrinski, H. ; Stürmann, J. ; Döring, R. ; Dudek, R. ; Rzepka, S. ; Michel, B.</creator><creatorcontrib>Keller, J. ; Mrossko, R. ; Dobrinski, H. ; Stürmann, J. ; Döring, R. ; Dudek, R. ; Rzepka, S. ; Michel, B.</creatorcontrib><description>In MEMS packaging moisture uptake of packaging materials may lead to severe changes in sensor behavior and package reliability. Knowledge and understanding of the effect of moisture swelling on the overall package deformation and on the sensor system is therefore inevitable for a successful MEMS design and packaging solution. The paper shows a design optimization of a pressure sensor packaging towards minimization of sensor drift due to stresses induced by moisture uptake. The work was done in a combined experimental and simulative approach. Experimental data clearly shows the sensor sensitivity to moisture uptake of polymer based packaging material. Based on the experimental findings the complete sensor package was modeled by means of finite element analysis. In a second step a new packaging geometry was defined to reduce the effect of moisture swelling to sensor signal. Additionally sensitivity of the sensor output signal to viscoelastic properties of three different moulding compounds was simulated. In the result of the work an optimized package design was achieved.</description><identifier>ISSN: 0026-2714</identifier><identifier>EISSN: 1872-941X</identifier><identifier>DOI: 10.1016/j.microrel.2013.07.107</identifier><identifier>CODEN: MCRLAS</identifier><language>eng</language><publisher>Kidlington: Elsevier Ltd</publisher><subject>Applied sciences ; Computer simulation ; Design. Technologies. Operation analysis. Testing ; Electronics ; Exact sciences and technology ; General equipment and techniques ; Hygrometers ; Instruments, apparatus, components and techniques common to several branches of physics and astronomy ; Integrated circuits ; Mathematical models ; Micro- and nanoelectromechanical devices (mems/nems) ; Moisture ; Packages ; Packaging ; Physics ; Semiconductor electronics. Microelectronics. Optoelectronics. Solid state devices ; Sensors ; Sensors (chemical, optical, electrical, movement, gas, etc.); remote sensing ; Swelling ; Uptakes</subject><ispartof>Microelectronics and reliability, 2013-09, Vol.53 (9-11), p.1648-1654</ispartof><rights>2013 Elsevier Ltd</rights><rights>2014 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c375t-44855de51f71ddcaee100829a24d2859c93c2c43fac426ae6f86eecc8dc427783</citedby><cites>FETCH-LOGICAL-c375t-44855de51f71ddcaee100829a24d2859c93c2c43fac426ae6f86eecc8dc427783</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0026271413002837$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>309,310,314,776,780,785,786,3537,23909,23910,25118,27901,27902,65306</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=27921718$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Keller, J.</creatorcontrib><creatorcontrib>Mrossko, R.</creatorcontrib><creatorcontrib>Dobrinski, H.</creatorcontrib><creatorcontrib>Stürmann, J.</creatorcontrib><creatorcontrib>Döring, R.</creatorcontrib><creatorcontrib>Dudek, R.</creatorcontrib><creatorcontrib>Rzepka, S.</creatorcontrib><creatorcontrib>Michel, B.</creatorcontrib><title>Effect of moisture swelling on MEMS packaging and integrated sensors</title><title>Microelectronics and reliability</title><description>In MEMS packaging moisture uptake of packaging materials may lead to severe changes in sensor behavior and package reliability. Knowledge and understanding of the effect of moisture swelling on the overall package deformation and on the sensor system is therefore inevitable for a successful MEMS design and packaging solution. The paper shows a design optimization of a pressure sensor packaging towards minimization of sensor drift due to stresses induced by moisture uptake. The work was done in a combined experimental and simulative approach. Experimental data clearly shows the sensor sensitivity to moisture uptake of polymer based packaging material. Based on the experimental findings the complete sensor package was modeled by means of finite element analysis. In a second step a new packaging geometry was defined to reduce the effect of moisture swelling to sensor signal. Additionally sensitivity of the sensor output signal to viscoelastic properties of three different moulding compounds was simulated. In the result of the work an optimized package design was achieved.</description><subject>Applied sciences</subject><subject>Computer simulation</subject><subject>Design. Technologies. Operation analysis. Testing</subject><subject>Electronics</subject><subject>Exact sciences and technology</subject><subject>General equipment and techniques</subject><subject>Hygrometers</subject><subject>Instruments, apparatus, components and techniques common to several branches of physics and astronomy</subject><subject>Integrated circuits</subject><subject>Mathematical models</subject><subject>Micro- and nanoelectromechanical devices (mems/nems)</subject><subject>Moisture</subject><subject>Packages</subject><subject>Packaging</subject><subject>Physics</subject><subject>Semiconductor electronics. Microelectronics. Optoelectronics. Solid state devices</subject><subject>Sensors</subject><subject>Sensors (chemical, optical, electrical, movement, gas, etc.); remote sensing</subject><subject>Swelling</subject><subject>Uptakes</subject><issn>0026-2714</issn><issn>1872-941X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNqFkE1LAzEQhoMoWKt_QXIRvOyaZD-ye1Nq_YAWDyp4CyGZlNTdpCZbxX9vllavnoZ5eeedmQehc0pySmh9tc57q4IP0OWM0CInPOn8AE1ow1nWlvTtEE0IYXXGOC2P0UmMa0IIJ5RO0O3cGFAD9gb33sZhGwDHL-g661bYO7ycL5_xRqp3uRoV6TS2boBVkANoHMFFH-IpOjKyi3C2r1P0ejd_mT1ki6f7x9nNIlMFr4asLJuq0lBRw6nWSgJQQhrWSlZq1lStagvFVFkYqUpWS6hNUwMo1ejUc94UU3S5y90E_7GFOIjeRpWOlQ78NgpaFSmRUc6Std5ZE5kYAxixCbaX4VtQIkZsYi1-sYkRmyA86TwNXux3yKhkZ4J0ysa_acbblE_HW653PkgPf1oIIioLToG2IQEV2tv_Vv0AZVWGsw</recordid><startdate>20130901</startdate><enddate>20130901</enddate><creator>Keller, J.</creator><creator>Mrossko, R.</creator><creator>Dobrinski, H.</creator><creator>Stürmann, J.</creator><creator>Döring, R.</creator><creator>Dudek, R.</creator><creator>Rzepka, S.</creator><creator>Michel, B.</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>20130901</creationdate><title>Effect of moisture swelling on MEMS packaging and integrated sensors</title><author>Keller, J. ; Mrossko, R. ; Dobrinski, H. ; Stürmann, J. ; Döring, R. ; Dudek, R. ; Rzepka, S. ; Michel, B.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c375t-44855de51f71ddcaee100829a24d2859c93c2c43fac426ae6f86eecc8dc427783</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Applied sciences</topic><topic>Computer simulation</topic><topic>Design. Technologies. Operation analysis. Testing</topic><topic>Electronics</topic><topic>Exact sciences and technology</topic><topic>General equipment and techniques</topic><topic>Hygrometers</topic><topic>Instruments, apparatus, components and techniques common to several branches of physics and astronomy</topic><topic>Integrated circuits</topic><topic>Mathematical models</topic><topic>Micro- and nanoelectromechanical devices (mems/nems)</topic><topic>Moisture</topic><topic>Packages</topic><topic>Packaging</topic><topic>Physics</topic><topic>Semiconductor electronics. Microelectronics. Optoelectronics. Solid state devices</topic><topic>Sensors</topic><topic>Sensors (chemical, optical, electrical, movement, gas, etc.); remote sensing</topic><topic>Swelling</topic><topic>Uptakes</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Keller, J.</creatorcontrib><creatorcontrib>Mrossko, R.</creatorcontrib><creatorcontrib>Dobrinski, H.</creatorcontrib><creatorcontrib>Stürmann, J.</creatorcontrib><creatorcontrib>Döring, R.</creatorcontrib><creatorcontrib>Dudek, R.</creatorcontrib><creatorcontrib>Rzepka, S.</creatorcontrib><creatorcontrib>Michel, B.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Microelectronics and reliability</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Keller, J.</au><au>Mrossko, R.</au><au>Dobrinski, H.</au><au>Stürmann, J.</au><au>Döring, R.</au><au>Dudek, R.</au><au>Rzepka, S.</au><au>Michel, B.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of moisture swelling on MEMS packaging and integrated sensors</atitle><jtitle>Microelectronics and reliability</jtitle><date>2013-09-01</date><risdate>2013</risdate><volume>53</volume><issue>9-11</issue><spage>1648</spage><epage>1654</epage><pages>1648-1654</pages><issn>0026-2714</issn><eissn>1872-941X</eissn><coden>MCRLAS</coden><abstract>In MEMS packaging moisture uptake of packaging materials may lead to severe changes in sensor behavior and package reliability. Knowledge and understanding of the effect of moisture swelling on the overall package deformation and on the sensor system is therefore inevitable for a successful MEMS design and packaging solution. The paper shows a design optimization of a pressure sensor packaging towards minimization of sensor drift due to stresses induced by moisture uptake. The work was done in a combined experimental and simulative approach. Experimental data clearly shows the sensor sensitivity to moisture uptake of polymer based packaging material. Based on the experimental findings the complete sensor package was modeled by means of finite element analysis. In a second step a new packaging geometry was defined to reduce the effect of moisture swelling to sensor signal. Additionally sensitivity of the sensor output signal to viscoelastic properties of three different moulding compounds was simulated. In the result of the work an optimized package design was achieved.</abstract><cop>Kidlington</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.microrel.2013.07.107</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0026-2714 |
ispartof | Microelectronics and reliability, 2013-09, Vol.53 (9-11), p.1648-1654 |
issn | 0026-2714 1872-941X |
language | eng |
recordid | cdi_proquest_miscellaneous_1531002172 |
source | Elsevier ScienceDirect Journals |
subjects | Applied sciences Computer simulation Design. Technologies. Operation analysis. Testing Electronics Exact sciences and technology General equipment and techniques Hygrometers Instruments, apparatus, components and techniques common to several branches of physics and astronomy Integrated circuits Mathematical models Micro- and nanoelectromechanical devices (mems/nems) Moisture Packages Packaging Physics Semiconductor electronics. Microelectronics. Optoelectronics. Solid state devices Sensors Sensors (chemical, optical, electrical, movement, gas, etc.) remote sensing Swelling Uptakes |
title | Effect of moisture swelling on MEMS packaging and integrated sensors |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T12%3A08%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20moisture%20swelling%20on%20MEMS%20packaging%20and%20integrated%20sensors&rft.jtitle=Microelectronics%20and%20reliability&rft.au=Keller,%20J.&rft.date=2013-09-01&rft.volume=53&rft.issue=9-11&rft.spage=1648&rft.epage=1654&rft.pages=1648-1654&rft.issn=0026-2714&rft.eissn=1872-941X&rft.coden=MCRLAS&rft_id=info:doi/10.1016/j.microrel.2013.07.107&rft_dat=%3Cproquest_cross%3E1531002172%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1531002172&rft_id=info:pmid/&rft_els_id=S0026271413002837&rfr_iscdi=true |